By using our website you are accepting that we employ cookies to count the number of visitors and for advertising purposes, and that they may be shared with third parties, for instance by using web analysis services. Our data protection statement contains further information and options for cancelling cookie consent. Data protection statement
Cookie Consent plugin for the EU cookie lawBuilt-in calibration, potential separation, configurable by DIP-switches, easy installation on DIN mounting rails, optionally version with protection class IP65
Model | 9243 |
Measurement accuracy | < 0.05 % F.S. |
Type of sensor |
|
Interfaces |
|
Sensor excitation |
Strain gauge:
Potentiometer:
Transmitter or DC/DC:
|
Protection class | IP20 / IP65 |
Supply voltage |
20 ... 36 VDC |
Specific characteristics |
|
The amplifier module model 9243 is used wherever measurement signals from strain gauges, potentiometric sensors or DC/DC sensors have to be converted into standard signals. Simply by mounting on conventional DIN-mount rails, it is possible to position the amplifier module on location, in the proximity of the sensor. Especially for rough environments a IP65 version is available.
The broad auxiliary power range and the choice between AC or DC permits operation on standard power supplies used in switch gear cabinets. A highly precise reference voltage source is built-in for calibration purposes. A calibrating shunt can also be connected via two separate terminals. This permits deliberate detuning of a strain gauge sensor for calibration or merely to check the measuring chain.
A highly accurate precision amplifier performs the amplification of the sensor signal being applied. The necessary gain factor is adjusted coarsely with DIP switches while fine-tuning is carried out by using a potentiometer. Current and voltage outputs are available simultaneously. The sensor excitation is performed by the amplifier module itself so that no additional voltage source is required. It can also be set in steps of 2.5 V, 5 V, 10 V using DIP switches. The maximum feed current of 35 mA permits parallel connection of several strain gages, e.g. for the addition of measurement variables. Measurement errors brought about by varying line lengths or due to temperature fluctuations effecting the sensor cable are avoided by having probe lines measuring the actual feed voltage directly on site at the sensor itself (6 wire technology). Fluctuations are immediately corrected electronically. The cut-off frequency of the amplifier can be switched between 10 Hz and 1 kHz. The DIP switches for configuring the entire device are found easily accessible, under a cover.
Talstr. 1-5
76593 Gernsbach
Germany
Fon: +49 7224645-0
Fax: +49 7224645-88
infoburster.com
www.burster.com
Motek
08.10. -
11.10.18 -
Stuttgart,
76593,
Germany
Please notice that there is a limit of 5 products for the product comparison.
Your latest selection was canceled.
×Visit us!
Motek Stuttgart
8th -11th October 2018
Hall 3, Booth 3222
Discover our new products!
burster gmbh & co kg
sensors & precision measurement
Talstr. 1-5
76593 Gernsbach
GERMANY
Contact:
Phone: (+49) 07224-6450
Fax: (+49) 07224-64588
E-Mail:
infoburster.de
The measurement solution.
It‘s with this ambition and for over half a century burster,
a global player in the precision measurement technology industry,
supplies some of the world’s most recognizable brands with sensors,
precision measuring devices and measuring systems for sensor signaling
processing. This is all done through our research, development and
production headquarters in Germany.
Where quality assurance and production control play a significant role, burster is on board.