Manual · Adtran
Total Access 850 Bank Controller Unit Installation and Operation
Manual10 pagesPDF 244 KB
Installation and operation practice for the ADTRAN Total Access 850 Bank Controller Unit (BCU), the TA 850's T1 control module.
What this file really is
The old site listed this file as a manual for the Adtran BCU 1200373L2. The document covers the TA 850 BCU part number 1200373L1 (List 1); it does not mention 1200373L2.
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
ADTRAN installation and operation practice for the TA 850 Bank Controller Unit (BCU), part number 1200373L1, the common plug-in module that controls every access module in a Total Access 850 and terminates the network T1 with a built-in CSU. It covers installing the card, DIP switch and menu provisioning through the VT 100 craft port, time slot assignment, connections, the faceplate LED and bantam jacks, T1 loopbacks and self test, flash firmware upload, specifications, warranty and FCC and Canadian regulatory information.
Its parts
- General
- Installation/Operation
- Options
- Testing
- Specifications
- Maintenance
- Warranty and Customer Service
- Limited Product Warranty
- Regulatory Requirements
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
ADTRAN practice 61200373L1-5B (Issue 2, August 2001) on installing and operating the Total Access 850 Bank Controller Unit (BCU), List 1, part number 1200373L1. The site files it under BCU 1200373L2, a part number the document itself does not print. It walks through installation, DIP switch and menu provisioning, time slot assignment, testing, specifications and flash firmware upload.
- Device type
- Common plug-in module with a built-in CSU that controls the TA 850 common units and all access modules p. 1
- Compatibility
- Total Access 850 only; fits the controller slot of the chassis p. 1, 2
- Part number
- 1200373L1 (List 1) p. 1
- Faceplate
- ADMIN DB-9 for a VT100 terminal, TEST DB-9 for DS0 test timing, bantam jacks for the network T1, network LED p. 1
- Craft port settings
- 9600 baud, no parity, 8 data bits, 1 stop bit; male-to-male RS-232 DB-9 cable p. 2
- TEST connector
- DB-9 female; outputs 8 kHz and 64 kHz clock reference for DS0 test sets such as a TPI 108/109 p. 3
- Time slots
- 24 T1 time slots; access slots 1-6 take 4 each in plug and play, A/B special slot (Nx56/64) uses 1-24 p. 2
- DIP switch S1
- 8 positions: framing SF/ESF, line code AMI/B8ZS, TR-08 signaling, CSU loopback, timing mode, line build out p. 2, 4
- DIP defaults
- SF framing, AMI, TR-08 enabled, CSU loopback enabled, loop timing, -22.5 dB build out p. 4
- Firmware
- Flash upload through the faceplate VT100 craft port using XMODEM, at 9600 up to 57.6 K baud p. 5
- T1 loopbacks
- Initiates and answers remote payload or line loopbacks (ESF mode only); answers remote CSU loopbacks p. 5
- Dimensions, weight
- 1 11/16 in W x 3 in H x 10 in L; 1 lb p. 5
- Relative humidity
- Up to 95%, noncondensing p. 5
- Network jack
- RJ-48C (USOC) for the T1 port p. 8
What this manual walks you through
- Installing the BCU in the controller slot p. 2
- Setting DIP switch S1 options p. 2, 4
- Connecting a VT100 terminal or Hyperterminal to the ADMIN craft port p. 2
- Assigning T1 time slots to access modules p. 2
- Reading the Network T1 LED p. 3
- Testing with the bantam jacks, TEST connector and T1 loopbacks p. 3, 5
- Flash uploading new firmware p. 5
- Filing the affidavit for connection to digital services p. 6, 7
Good to know
- For installation in Restricted Access Locations only, in equipment with a Type B or E installation code. p. 2
- The BCU keeps its provisioning when removed; in another chassis it applies that setup to that chassis' access modules. p. 2
- Once the BCU is installed, software provisioning overrides the DIP switch settings. p. 2
- Connecting the FT1 port toward the network needs a suitable crossover cable. p. 8
- Shielded cables must be used to stay within Class A FCC limits; field repairs are not recommended. p. 5, 8
Questions this manual answers
What are the craft port settings for the Total Access 850 BCU?
9600 baud, no parity, 8 data bits and 1 stop bit, over a standard male-to-male RS-232 DB-9 cable. p. 2
What does a blinking red Network T1 LED mean on the TA 850 BCU?
The BCU failed the self test it runs when inserted into an active TA 850 chassis. p. 5
How do I update the TA 850 BCU firmware?
Connect to the craft port, open the Bank Controller submenu, select Upload Code and send the file by XMODEM; the unit then resets itself. p. 5
How many T1 time slots does each TA 850 access slot take?
In plug and play, each card in slots 1-6 takes 4 time slots, so slot 1 gets 1-4 and slot 6 gets 21-24. p. 2
Does the TA 850 BCU keep its settings when moved to another chassis?
Yes, it retains its provisioning when removed and applies it to the access modules of the new chassis. p. 2
The whole text · 1 part
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file