Page 33
Pico and Pico GFX-70 Programmable Controllers
33
Fill in the Selection Worksheet Catalog Number
Description
Programming Software and Cable PicoSoft Pro Programming Software 1760-PICOSOFTPRO(1) 1760-CBL-PM02 1760-CBL-PC02 1760-PICOPRO-PC02 Communications Module 1760-DNET Pico Controllers 1760-L12AWA 1760-L12AWA-NC 1760-L12AWA-ND 1760-L12BBB 1760-L12BBB-ND 1760-L12BWB 1760-L12BWB-NC 1760-L12BWB-ND 1760-L12DWD 1760-L12DWD-ND 1760-L12NWN 1760-L12NWN-ND 1760-L18AWA-EX 1760-L18AWA-EXND 1760-L18BWB-EX 1760-L18BWB-EXND 1760-L18DWD-EX 1760-L18DWD-EXND 1760-L18NWN-EX 1760-L18NWN-EXND 1760-L20BBB-EX 1760-L20BBB-EXND Pico Expansion I/O Modules 1760-IA12XOW6I 1760-IB12XOB8 1760-IB12XOW6I 1760-OW2 1760-RPLCONN Pico GFX-70 Processor Units 1760-LDF 1760-LDFA 1760-LDFC 1760-LDFCA Pico Remote Processor Units 1760-RM-PICO
Pieces per Package
Quantity Selected
1
Programming Cable, PC to Pico Processor Programming Cable, PC to Pico GFX Processor PicoSoft Pro Software and Pico GFX Cable Kit
1 1
Pico DeviceNet Module
1
Pico 12-Point AC Controller Pico 12-Point AC Controller without Real-Time Clock Pico 12-Point AC Controller without Display Pico 12-Point DC Controller Pico 12-Point DC Controller without Display Pico 12-Point DC Controller Pico 12-Point DC Controller without Real-Time Clock Pico 12-Point DC Controller without Display Pico 12-Point AC Controller Pico 12-Point AC Controller without Display Pico 12-Point AC Controller Pico 12-Point AC Controller without Display Pico 18-Point AC Controller I/O Expandable Pico 18-Point AC Controller I/O Expandable without Display Pico 18-Point DC Controller I/O Expandable Pico 18-Point DC Controller I/O Expandable without Display Pico 18-Point DC Controller I/O Expandable Pico 18-Point DC Controller I/O Expandable without Display Pico 18-Point AC Controller I/O Expandable Pico 18-Point AC Controller I/O Expandable without Display Pico 20-Point DC Controller I/O Expandable Pico 20-Point DC Controller I/O Expandable without Display
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
(12) 120/240V ac inputs, (6) isolated relay outputs (12) 24V dc inputs, (8) transistor outputs (12) 24V dc inputs, (6) isolated relay outputs (2) relay outputs Expansion Module Connector - included with expansion module. Catalog number listed is replacement part.
1 1 1 1 1
Pico GFX-70 DC Processor Unit Pico GFX-70 AC Processor Unit Pico GFX-70 DC Processor Unit with Pico-Link Terminal Pico GFX-70 AC Processor Unit with Pico-Link Terminal
1 1 1 1
Pico Remote Processor Unit
1
Publication 1760-SG001F-EN-P - May 2006
Page 34
34
Pico and Pico GFX-70 Programmable Controllers
Catalog Number
Description
1760-RM-GFX Pico GFX-70 Remote Processor Unit Pico GFX-70 I/O Modules 1760-IA12XOW4I (12) 120V ac inputs, (4) relay outputs 1760-IB12XOW4IF (12) 24V dc inputs, (4) relay outputs, analog input 1760-IB12XOW4IOF (12) 24V dc inputs, (4) relay outputs, analog input and output 1760-IB12XOB4IF (12) 24V dc inputs, (4) transistor outputs, analog input 1760-IB12XOB4IOF (12) 24V dc inputs, (4) transistor outputs, analog input and output Display Units 1760-DUB Display Unit with Push buttons 1760-DU Display Unit without Push buttons Memory Module 1760-MM1 Pico 8 K Memory Module for 12-Point Controllers 1760-MM2 Pico 16 K Memory Module for 18-Point Controllers 1760-MM2B Pico 32 K Memory Module 1760-MM3 Pico GFX-70 256 K Memory Module Power Supply 1606-XLP30E DC Power Supply Point-to-Point Serial Interface Cables 1760-CBL-2M Point-to-Point Serial Interface Cable, 2 m (6.6 ft) 1760-CBL-5M Point-to-Point Serial Interface Cable, 5 m (16.4 ft) Cables for Pico-Link between Processors 1760-CBL-INT01 Pico-Link Cable, 0.3 m (1 ft) 1760-CBL-INT03 Pico-Link Cable 0.8 m (2.6 ft) 1760-CBL-INT05 Pico-Link Cable 1.5 m (5 ft) 1760-CBL-INT300 Pico-Link Cable, non-terminated, 100 m (300 ft) 1760-CONN-RJ45 Connectors for Pico-Link Cable 1760-TERM1 Network Termination Resistor Protective Covers 1760-NDM Membrane Protect Display 1760-NDC Cover Protect Display Mounting Feet 1760-NMF Mounting Feet (for panel mounting processors and I/O modules) Tools 1492-N90 Screwdriver 1492-KWC Wire Cutter Input Simulator 1760-SIM Input Simulator for 12 I/O DC Pico Controller
Pieces per Package 1
Quantity Selected
1 1 1 1 1 1 1 1 1 1 1 1 1 1 5 3 2 1 2 2 1 1 8 5 1 1
(1)
PicoSoft software version 6.1 or later must be used for the Series B Pico controller. Earlier versions of PicoSoft software can only be used with Series A Pico controllers.
Publication 1760-SG001F-EN-P - May 2006
Page 35
Pico and Pico GFX-70 Programmable Controllers
35
Publication 1760-SG001F-EN-P - May 2006
Page 36
Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://support.rockwellautomation.com, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. For an additional level of technical phone support for installation, configuration, and troubleshooting, we offer TechConnect Support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit http://support.rockwellautomation.com.
Installation Assistance If you experience a problem with a hardware module within the first 24 hours of installation, please review the information that's contained in this manual. You can also contact a special Customer Support number for initial help in getting your module up and running. United States
1.440.646.3223 Monday – Friday, 8am – 5pm EST
Outside United States
Please contact your local Rockwell Automation representative for any technical support issues.
New Product Satisfaction Return Rockwell tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning, it may need to be returned. United States
Contact your distributor. You must provide a Customer Support case number (see phone number above to obtain one) to your distributor in order to complete the return process.
Publication 1760-SG001F-EN-P - May 2006 36 Supersedes Publication 1760-SG001E-EN-P - January 2006
Copyright © 2006 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.