Allen-Bradley installation data for the 1771-IT fast response DC input module, an 8-input 12-24 V DC module for the 1771 I/O chassis suited to photoelectric switches, incremental encoders and DC proximity switches. It covers pre-installation considerations, power requirements, keying the I/O chassis, installing the module, wiring the 1771-WA field wiring arm (including driving it from a 1771-OB output module), reading the status indicators, and specifications.

Its parts

  1. To The Installer
  2. Pre-installation Considerations
  3. Power Requirements
  4. Installing Your Module
  5. Interpreting the Status Indicators
  6. Specifications

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

Installation data (publication 1771-2.22, June 1990) for the Allen-Bradley 1771-IT Fast Response DC Input Module. It covers power requirements, keying the I/O chassis, installing and wiring the module, reading the status indicators and the specifications.

Device
Fast response DC input module, 8 inputs, for the 1771 I/O chassis p. 1, 5
Input voltage
12-24V DC nominal; logic 0 at 0V to 4V, logic 1 at 10V to 27V p. 5
Input current
8mA at 12V DC, 24mA at 24V DC p. 5
Backplane current
74mA from the chassis power supply p. 1, 5
Wiring arm
10-terminal field wiring arm 1771-WA, shipped with the module p. 3
Status indicators
8 red LEDs, one per input, lit when the input is on p. 4
Typical devices
Photoelectric switches, incremental encoders and dc proximity switches p. 1
Isolation
1500V AC (RMS) opto-electrical p. 5
Input impedance
On: 1-2K ohms; off: 2-3K ohms p. 5
Power dissipation
5.9 Watts max., 0.4 Watts min. (20.0 BTU/hr max.) p. 5
Terminals
Inputs on terminals 0 to 7, DC common on B, A not used p. 3
Wire
Stranded 14 or 16 gauge; 14 gage maximum, 3/64 inch insulation maximum p. 3, 5
Keying
Keying bands between 6 and 8 and between 32 and 34 p. 2
Humidity
5 to 95% without condensation p. 5

What this manual walks you through

  • Adding the module's backplane current to the chassis power budget p. 1
  • Keying an I/O chassis slot for this module p. 2
  • Installing the module in the chassis p. 2, 3
  • Wiring 2-wire input devices to the field wiring arm p. 3
  • Driving the inputs directly from a 1771-OB output module p. 3, 4
  • Reading the status indicators p. 4

Good to know

  • Because of its fast response the module may not suit hard contact devices; the manual recommends a 1771-IB for those. p. 1
  • Remove power from the chassis backplane and wiring arm before removing or installing the module. p. 2
  • When a 1771-OB drives the inputs, power both modules from the same dc source so the commons match. p. 3
  • The left-most chassis connector is reserved for adapter or processor modules. p. 2

Questions this manual answers

Can the 1771-IT be used with pushbuttons or other hard contacts?

It may not be suitable, because its fast response could register contact sources as input data; the manual recommends the 1771-IB for hard contacts. p. 1

How much backplane current does the 1771-IT draw?

74mA from the 1771 I/O chassis power supply. p. 1

What wiring arm does the 1771-IT use?

The 10-terminal field wiring arm, cat. no. 1771-WA, which is shipped with the module. p. 3

What input voltage does the 1771-IT accept?

12-24V DC nominal; an input reads as on from 10V to 27V and off from 0V to 4V. p. 5

Where do I put the keying bands for a 1771-IT?

Between 6 and 8 and between 32 and 34 on the backplane connector. p. 2

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1771-2.22, Fast Response DC Input Module Installation Data1
  2. To The Installer1
  3. Pre-installation Considerations1
  4. Power Requirements1
  5. Installing Your Module2
  6. Keying Your I/O Chassis2
  7. Installing the Input Module2
    1. Connecting Wiring to the Input Module3
  8. Interpreting the Status Indicators4
  9. Specifications5
  10. Back Cover5

From the PDF’s own bookmarks.

The whole text · 1 part

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 51-5

The file

Revision and size

Part no.1771-2.22
RevisionJune 1990
PublisherAllen-Bradley
Pages5
PDF62 KB
TextText from the PDF itself.
1771-2.22

The first pages · 3 of 5

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 5
Page 2
Page 2of 5
Page 3
Page 3of 5

More documents · 1

For the same models