Summary
What is in it
Allen-Bradley programming and operations manual for the Bulletin 1772 Mini-PLC-2 Programmable Controller, built from the Mini-PLC-2 Processor (1772-LN1, -LN2 or -LN3) and 1771 I/O racks and modules. It explains memory structure, hardware controls and indicators, relay-type, timer and counter, data manipulation, arithmetic and I/O update instructions, writing the user program, operating with the 1770-T1, -T2 or -T3 Industrial Terminal, peripheral functions such as report generation and tape recording, block transfer, scan time and numbering systems.
Its parts
- Introduction
- Hardware Considerations
- Relay-Type Instructions
- Timer and Counter Instructions
- Data Manipulation Instructions
- Arithmetic Instructions
- Output Override and I/O Update Instructions
- Writing the User Program
- Operating Instructions
- Peripheral Functions
- Special Programming Techniques
- Scan Time and Instruction Execution Time
- Numbering Systems
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
Allen-Bradley Programming and Operations Manual (1982) for the Bulletin 1772 Mini-PLC-2 Programmable Controller, whose processor modules it lists as 1772-LN1, -LN2 and -LN3. It explains the processor memory, the mode switch and indicators, hooking up the 1770 Industrial Terminal, and programming relay, timer, counter, data and arithmetic instructions. The pages are scans read by OCR.
- Device
- Processor module of the Bulletin 1772 Mini-PLC-2 Programmable Controller, used with the 1771 I/O family of racks and modules p. 11
- Memory
- 1772-LN2 and 1772-LN3: 1024 words of read/write CMOS memory p. 11, 13
- Data table
- Factory configured to 128 words p. 13
- Programming devices
- Industrial Terminal 1770-T1, -T2 or -T3; PLC-2 Program Panel 1772-T1; PLC Program Panel with adapter 1774-TA and 1772-T4 p. 15
- Programming cable
- 1772-TC (10 ft.), from Industrial Terminal Channel A to the processor's INTERFACE socket p. 21, 22
- Mode switch
- Three-position keylock: PROGRAM, TEST, RUN; key removable only in RUN p. 19
- Indicators
- Processor: PROCESSOR and MEMORY (red), RUN (green); power supply: BATTERY LOW and DC ON p. 20
- Low line cutoff
- Outputs disabled when user AC drops below 98V (120V operation) or 196V (220/240V operation) p. 20
- Battery backup
- Batteries back up memory; about one week left once BATTERY LOW flashes; Battery Low Bit 027/00 p. 20
- Fault output switch
- Switch #1 on the Switch Group Assembly (left side of the I/O chassis backplane): ON keeps outputs in last state, OFF de-energizes them p. 21
- Data Highway
- Connects through the Communication Adapter Module 1771-KA; RS-232-C interfacing also supported p. 11, 15
- Block Transfer
- 1772-LN3: Block Transfer with intelligent Bulletin 1771 I/O modules such as thermocouple, analog and encoder/counter p. 11, 15
- Keytop overlay
- PLC-2 Keytop Overlay 1770-KCA on Keyboard Module 1770-FDC p. 22
- Logic supply
- 5.1V DC; the controller shuts down if it drops below that p. 21
What this manual walks you through
- Connecting the Industrial Terminal to the processor p. 21, 22
- Using the PROG, TEST and RUN switch positions p. 19
- Reading the processor and power supply indicators p. 19, 20, 21
- Choosing what outputs do after a processor fault p. 21
- How the memory and data table are organized p. 12, 13, 14
- Loading programs written for other PLC-2 family processors p. 15, 18
- Monitoring bits and forcing inputs or outputs while troubleshooting p. 81, 82
- Programming relay, timer, counter, data manipulation and arithmetic instructions p. 3, 4
Good to know
- Switch #1 should be OFF for most applications; with it ON the machine can keep running after a fault, and equipment damage or injury could result. p. 21
- Programs from larger PLC-2 processors fit only if the data table is 128 words or less and memory use is within 1024 words for the 1772-LN2 or -LN3. p. 15
- In TEST mode inputs are read but output devices are not energized. p. 19
- Installation, start-up and troubleshooting are covered in Publication 1772-820, not in this manual. p. 19
Questions this manual answers
How much memory does the Allen-Bradley 1772-LN2 have?
The 1772-LN2 and 1772-LN3 processors have 1024 words of memory; the data table is factory configured to 128 words. p. 13
What does the red PROCESSOR light mean on a Mini-PLC-2?
The processor cannot scan the program and data table and has stopped talking to the I/O. A reset can be tried by switching to PROGRAM and back to RUN, cycling power, or reloading the program. p. 20
What cable connects an Industrial Terminal to the Mini-PLC-2?
The 1772-TC interconnect cable (10 ft.), from Channel A on the terminal to the INTERFACE socket on the processor. p. 21, 22
How long does the Mini-PLC-2 battery last after BATTERY LOW starts flashing?
About one week of memory backup remains after the indicator begins to flash. p. 20