Page 12

Chapter

1

Using This Manual

Chapter Objectives

Read this chapter before you use your processor. Important: This manual is for the series D Mini-PLC-2/02, Mini-PLC-2/16 and Mini-PLC-2/17 processors. See the Series Changes on page 3-2 for the differences with other processor series.

Differences

This manual describes the Mini-PLC-2/02, Mini-PLC-2/16 and Mini-PLC-2/17 processors. Unless stated otherwise, assume the features or instructions are common to all the processors. Feature

Mini-PLC-2/02

Mini-PLC-2/16

Mini-PLC-2/17

Size of memory (words)

2K

4K

7.75K

Size of EEPROM backup (words)

4K

4K

8K

Data table expansion (words)

1920

3968

7808

EAF instructions (up to 12 digits)

Add Subtract Multiply Divide

Add Subtract Multiply Divide

Add Subtract Multiply Divide

EAF instructions

Square Root BCD to Binary Binary to BCD FIFO Load FIFO Unload Log10 Sin X Cos X 10x

Square Root BCD to Binary Binary to BCD FIFO Load FIFO Unload Log10 Sin X Cos X 10x

Square Root BCD to Binary Binary to BCD FIFO Load FIFO Unload Log10 Sin X Cos X 10x

Additional EAF instructions none none

Loge y+/-x e+/-x Reciprocal of x Averaging Standard Deviation PID Wall Clock/Calendar

1-1

Page 13

Chapter 1 Using This Manual

What's this User Manual Contains

This manual is divided into eight sections (Table 1.A): Table 1.A Sections of the Mini-PLC-2/02, Mini-PLC-2/16, and Mini-PLC-2/17 Processor User Manual Information Sections

What's Covered

In Chapters

Overview how to use this manual; fundamentals of programmable controllers

1-2

Hardware the processor's hardware features; how to assemble, install, start, maintain, and troubleshoot the processor

3

Basic instruction set how to use basic instructions common to all PLC-2 family processors

4-13

Advanced instruction set how to use advanced instructions unique to some the processors

14-22

Programming procedures and troubleshooting how to use special programming techniques and follow 23-26 a troubleshooting guide so you can minimize production down time

Specifications, comparison chart, number systems, and glossary specifications; PLC-2 family comparison chart; explanation of number systems; and list of processor terms used in this manual

Appendices A-D

Quick reference selected tables in this manual

Appendix E

This manual is procedure oriented. It tells you how to program and operate your Mini-PLC-2/02, Mini-PLC-2/16, and Mini-PLC-2/17 processor. If you need to learn more about these processors, contact your local Allen-Bradley representative or distributor.

Vocabulary

To make this manual easier to read and understand, we refer to the: We Refer to the:

As the:

Mini-PLC-2/02, Mini-PLC-2/16, and Mini-PLC-2/17 Processors processors

Electrically Erasable Programmable Read Only Memory

EEPROM

Programmable Read Only Memory

PROM

Execute Auxiliary Function

EAF

Complementary Metal Oxide Semi-conductor Random Access Memory

CMOS RAM

Industrial Terminal (cat. no. 1770-T3)

1770-T3 terminal

A glossary at the back of this manual clarifies technical terms.

1-2

Page 14

Chapter 1 Using This Manual

Conventions

A word equals 16 bits; a byte equals 8 bits (1/2 of a word). Words in [ ] denote a key name or symbol. Words in < > denote information that you must provide - for example, an address value. All word addresses are displayed in the octal numbering system. Therefore, references to base 8 are not displayed. Word values are displayed in: decimal (0-9) for timers, counters, and mathematics 010

030 CTU

00 Decimal

PR 555 AC 123 hexadecimal values (0-9, A-F) for Get and Put instructions 010 00

011 G FFF

012 G 123

030 00

Hexadecimal

Important: Numbers 0-9 are displayed the same in decimal and hexadecimal. octal byte values for examine on and output energize instructions 0101 B 237

030 00

Octal

Keystroke directions are divided into two columns:

tells you what key or keys to press tells you the processor’s action

1-3

Page 15

Chapter 1 Using This Manual

Figure 1.1 shows the keystrokes to produce a display. Figure 1.1 Illustration Showing Keystroke Conventions

Start by positioning your cursor on the words SEQUENCER INPUT. Use the arrow keys to move the cursor. The word display appears in the lower left hand corner of the screen. DISPLAY

0

BINARY DATA MONITOR SEQUENCER OUTPUT STEP: 001 SEQUENCER LENGTH: COUNTER ADDR: 200 FILE: 400- 413 201 OUTPUT ADDR: 110 DATA: 00000000 00000000 00000000 00000000 MASK ADDR: 070 DATA: 00000000 00000000 STEP 001 002 003 004 005 006

Related Publications

1-4

006

071 00000000 00000000

WORD 1 WORD 2 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 DATA: 00000000 00000000

The publication index, publication SD 499, lists all available publications to further inform you about products related to the Mini-PLC-2/02, Mini-PLC-2/16, and Mini-PLC-2/17 processors. Consult your local Allen-Bradley distributor or sales engineer for information regarding this publication or any needed information.