Page 1 of Allen-Bradley 800H-HR2B, 800T-A9, 800T-E15M6A, 800T-U4, 800T-U13 and 800TC-N374 Spec Sheet

Spec sheet · Allen-Bradley

Allen-Bradley 800H-HR2B, 800T-A9, 800T-E15M6A, 800T-U4, 800T-U13 and 800TC-N374 Spec Sheet

Spec sheet3 pagesPDF 164 KB

All 3 pages are below, each with its text.

Download the PDF164 KB

Filed with · 6 models

Also filed with these models on the old site

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Three pages from Rockwell Automation publication 800-TD009A-EN-P on Allen-Bradley 800T/H 30.5 mm NEMA push buttons. They hold the ordering code tables for momentary non-illuminated push buttons, a dimensions page with shipping weights, and the general specifications. The site's numbers such as 800T-A9 and 800H-HR2B are not printed in them.

What it is
800T/H 30.5 mm NEMA push buttons, momentary contact, non-illuminated p. 1
800T and 800H
800T: metal, Type 4/13; 800H: plastic, Type 4/4X/13 p. 1
Degree of protection
Type 1/4/12/13 (800T); Type 1/4/4X/12/13 (800H); EN/IEC 60529 IP66/65 p. 3
Operator codes
800T: A flush head, B extended head, D mushroom head; 800H: AR, BR, DR p. 1
Color cap codes
1 green, 2 black, 3 orange, 4 grey, 5 white, 6 red, 7 blue, 9 yellow p. 1
Contact block codes
D1 1 N.O.; D2 1 N.C.; D3 1 N.O.E.M.; D4 1 N.C.L.B.; A 1 N.O. - 1 N.C.; B 2 N.O. - 2 N.C. p. 1
Wire and torque
#18…14 AWG (#18…10 Max Duty); terminal screws 6…8 lb•in p. 3
Time delay contacts
Adjustable 0.5 to 15 s + 25%; Ith 5 A; Series C kits fit Series T or later operators p. 1
Snap action contacts
Factory assembled units only; Ith 10 A p. 1
Shipping weight
Flush and extended head push button 5-1/2 oz (0.15 kg); mushroom head push button 7-1/2 oz (0.21 kg) p. 2
Contact operation
Shallow, mini and low-voltage blocks: slow, double make and break; Logic Reed and sealed switch blocks: single break magnetic p. 3
Vibration
10…2000 Hz, 1.52 mm displacement (peak-to-peak) max./10 G max. (except Logic Reed) p. 3
Shock
1/2 cycle sine wave for 11 ms: ≥ 25 G contact fragility, no damage at 100 G p. 3
Humidity
50…95% RH from 77…140 °F (25…60 °C), MIL-STD-810C cycling test p. 3

What this sheet walks you through

  • Building the ordering number of a momentary non-illuminated push button from its code tables p. 1
  • Dimensions and shipping weights of 800T operators p. 2
  • Electrical, mechanical and environmental specifications p. 3

Good to know

  • Operating temperatures below freezing assume no moisture or liquids are present. p. 3
  • A2 and A2R contact blocks cannot have other blocks stacked on them, but can stack on other blocks. p. 1
  • Jumbo mushroom heads are not available in white. p. 1
  • Orange, grey and white caps are marked as not available for booted operators. p. 1
  • The dimensions are not for manufacturing use. p. 2

Questions this sheet answers

Which color cap code is yellow on an 800T/H push button?

Code 9 is yellow. p. 1

Is the 800T or the 800H push button made of plastic?

The 800H is plastic (Type 4/4X/13); the 800T is metal (Type 4/13). p. 1

What wire size do 800T contact block terminals take?

#18 to 14 AWG (#18 to 10 for Max Duty), with 6 to 8 lb•in screw torque. p. 3

What does contact block code A mean for 800T push buttons?

Code A is 1 N.O. - 1 N.C.; code B is 2 N.O. - 2 N.C. p. 1

How much does an 800T flush head push button weigh?

The shipping weight of a flush or extended head push button is 5-1/2 oz (0.15 kg). p. 2

The file

Size and text

Pages3
PDF164 KB
TextText from the PDF itself.

Every page · 3

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Allen-Bradley 800H-HR2B, 800T-A9, 800T-E15M6A, 800T-U4, 800T-U13 and 800TC-N374 Spec Sheet

The text of page 1, from the PDF itself

NEMA Push Button Specifications

800T/H 30.5 mm Push Buttons

Momentary Contact Push Button Devices, Non-Illuminated

Flush Head Unit Cat. No. 800T-A1A

Extended Head Unit Cat. No. 800T-B6A

800

Booted Unit Cat. No. 800H-R2A

T a– A1cdb

Bootless Flush Head Unit Cat. No. 800H-AR1A

A efad (cont'd)f (cont'd)f (cont'd)Protection RatingColor CapContact Block(s)Contact Block(s)CodeDescriptionCodeDescriptionTMetal, Type 4/134Grey‡HPlastic, Type 4/4X/135White‡D1V1 N.O.6RedD2V1 N.C.D1P7BlueD3V1 N.O.E.M.D2P1 N.C.9YellowD4V1 N.C.L.B.AP1 N.O. - 1 N.C.eAV1 N.O. - 1 N.C.BPBV2 N.O. - 2 N.C.

b Finger-Safe Guards Code

DescriptionBlankNo guardsCGuards on terminals

c Operator Type 800T Type 4/13

Description800H Type 4/4X/13CodeCodeAFlush headARBExtended headBRDMushroom headDRDX

Mushroom head less color cap

DRX, Bootless guarded head

GR

Booted head, d Color Cap Code

Description

Blank

Used only when ordering Operator Type DX/DRX

1Green2Black3Orange‡Code

Special Mushroom Head Code

Description

J♣

Jumbo mushroom head, plastic

L♣

Jumbo mushroom head, metal

Note: Special mushroom head options only apply to mushroom head operator type code D/DR (Table c).

fDescriptionTime Delay T

1 N.O. Depress close, delayed opening

S

1 N.C. Depress open, delayed closure Snap Action

M N

1 N.O. - 1 N.C. 2 N.O. - 2 N.C. Class 1, Div. 2 Logic Reed

Contact Block(s) CodeDescriptionD1R1 N.O.BlankNo contactsD2R1 N.C.A2R2 N.O.§Standard D11 N.O.A4R2 N.C.D21 N.C.AR1 N.O. - 1 N.C.D31 N.O.E.M.BR2 N.O. - 2 N.C.D41 N.C.L.B.D51 N.O. (Mini)D61 N.C. (Mini)A11 N.C.L.B. - 1 N.O.A22 N.O.§A42 N.C.A71 N.C.L.B. - 1 N.C.A1 N.O. - 1 N.C.B2 N.O. - 2 N.C.CodePenTUFF (Low Voltage)

Description Class 1, Div. 2 Sealed Switch 1 N.O.

2 N.O. - 2 N.C Stackable Sealed Switch

D1Y1 N.O.D2Y1 N.C.A2Y2 N.O.A4Y2 N.C.AY1 N.O. - 1 N.C.BY

2 N.O. - 2 N.C Time Delay Contacts

Series C field installable kits can only be used with Series T or later operators. Adjustable range of 0.5 to 15 s + 25%. Maximum continuous current Ith 5 A. Snap Action Contacts Snap-action contacts feature a quick make, quick break snapaction mechanism that is only available on factory assembled units. Maximum continuous current Ith 10 A.

Underlying operators are extended head. Boot material is chlorosulfonated polyethylene. ‡ Not available for booted operators. § A2 and A2R contact blocks cannot be stacked upon, but can stack on other contact blocks. ♣ Jumbo mushroom heads not available in white color.

Rockwell Automation Publication 800-TD009A-EN-P

7

Page 2 of Allen-Bradley 800H-HR2B, 800T-A9, 800T-E15M6A, 800T-U4, 800T-U13 and 800TC-N374 Spec Sheet

The text of page 2, from the PDF itself

NEMA Push Button Specifications

800T/H 30.5 mm Push Buttons

Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

Push Buttons and Switches (Bul. 800T Only)

2-3-4 Way Switch Shipping Wt. with 2 Contact Blocks 6 oz (0.17 kg) Shipping Wt. with 4 Contact Blocks 8-1/2 oz (0.24 kg)

Mechanically Interlocked Maintained Contact Push Button Shipping Wt. 1 lb (0.45 kg)

Push Buttons and Pilot Lights

Ø

Extended Head Only

Flush and Extended Head Push Button Shipping Wt. 5-1/2 oz (0.15 kg)

Mushroom Head Push Button Shipping Wt. 7-1/2 oz (0.21 kg)

Non-Illuminated Knob Lever and Standard Knob Selector Switch Shipping Wt. 6 oz (0.17 kg)

Illuminated Knob Lever and Standard Knob Selector Switch Shipping Wt. 6 oz (0.17 kg)

Wing Lever Selector Switch Shipping Wt. 8 oz (0.22 kg)

Coin Slot Selector Switch Shipping Wt. 6 oz (0.17 kg)

Except jumbo which is 2-1/4 (57.2).

Operator Extension in Front of Panel (Bul. 800T Only)

Key Operated Selector Switch Shipping Wt. 12 oz (0.34 kg)

Push Button with Cylinder Lock Shipping Wt. 12 oz (0.34 kg)

Dia.

Wobble Stick Shipping Wt. 9 oz (0.25 kg)

Across Flats

Across Corners

Selector Push Button Shipping Wt. 6 oz (0.17 kg)

Type J Potentiometer Unit Shipping Wt. 4 oz (0.11 kg)

Rockwell Automation Publication 800-TD009A-EN-P

31

Page 3 of Allen-Bradley 800H-HR2B, 800T-A9, 800T-E15M6A, 800T-U4, 800T-U13 and 800TC-N374 Spec Sheet

The text of page 3, from the PDF itself

800T/H 30.5 mm Push Buttons

NEMA Push Button Specifications

Electrical Ratings Refer to the contact ratings tables on page 10-4. 2200V for one minute, 1300V for one minute (Logic Reed) 1,000,000 at max. rated load, 200,000 at max. rated load (Logic Reed)

Contact ratings Dielectric strength Electrical design life cycles

Mechanical Ratings 10…2000 Hz, 1.52 mm displacement (peak-to-peak) max./ 10 G max. (except Logic Reed) 1/2 cycle sine wave for 11 ms ≥ 25 G (contact fragility) and no damage at 100 G Type 1/4/12/13 (800T); Type 1/4/4X/12/13 (800H); EN/IEC 60529 IP66/65

Vibration Shock Degree of protection Mechanical design life cycles Push buttons

Selector switches

(Momentary, non-illuminated, flush and extended head) (Momentary, illuminated) (Push-pull/twist-to-release) (Non-illuminated) (Illuminated, key-operated)

Potentiometers All other devices Contact operation Wire gauge/Terminal screw torque Typical operating forces Operators without contact blocks Spring return selector switches Illuminated push buttons and push-to-test pilot lights 2-position push-pull 3-position push-pull Twist-to-release or push-pull Potentiometer Standard Logic Reed Sealed switch Contact blocks Stackable sealed switch MaxDuty PenTUFF Self Monitoring Operating Storage Note: Operating temperatures below freezing are based on the absence of moisture and liquids. Consult your local Rockwell Automation sales office or Allen-Bradley distributor for use in lower temperature applications. Temperature range

Humidity

10,000,000 min. 250,000 min. 250,000 min. ‡ 1,000,000 min. 200,000 min. 25,000 min. 200,000 min. Shallow, mini, and low-voltage contact blocks: Slow, double make and break Logic Reed and sealed switch contact blocks: Single break magnetic #18…14 AWG (#18…10 Max Duty) / 6…8 lb•in Flush, extended button, standard mushroom, jumbo plastic mushroom: 2 lbs max. Jumbo and extended aluminum mushroom head: 3.95 lbs max. Maintained selector switch: 3.6 in•lb max. 3.6 in•lb to stop, 0.2 in•lb to return 5 lb max. 8.0 lb max. push or pull 8 lb max. push to in position or pull to center position (15 lb max. pull to out position) 9 lbs max. push or pull 30 in•oz max. twist, 6 in•oz minimum return Rotational torque 3…12 in•oz; stopping torque 12 in•lb (minimum) 1 lb 1 lb max. 3 lb max. at 0.205 in. plunger travel 1 lb max. 1.4 lb max. 1.4 lb max. 1.6 lb Environment -40…+131 °F (-40…+55 °C) -40…+185 °F (-40…+85 °C)

50…95% RH from 77…140 °F (25…60 °C) per Procedure IV of MIL-STD-810C, Method 507.1 cycling test

Performance Data, Performance data given in this publication is provided only as a guide for the user in determining suitability and do not constitute a performance warranty of any kind. Such data may represent the results of accelerated testing at elevated stress levels, and the user is responsible for correlating the data to actual application requirements. ALL WARRANTIES AS TO ACTUAL PERFORMANCE, WHETHER EXPRESS OR IMPLIED, ARE EXPRESSLY DISCLAIMED. ‡ Illuminated Trigger Action E-stops are rated for 150,000 min. mechanical operations when using Cat. No. 800TC-XD4S Self-Monitoring Contact Blocks (SMCBs).

2

Rockwell Automation Publication 800-TD009A-EN-P