Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 3 of 91

9/Series CNC Hardware Integration and Maintenance Manual, pages 21 to 30

Pages 21 to 30 of 898

The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 8500-1746I

Page 21

Important User Information

Because of the variety of uses for this product and because of the differences between solid state products and electromechanical products, those responsible for applying and using this product must satisfy themselves as to the acceptability of each application and use of this product. For more information, refer to publication SGI-1.1 (Safety Guidelines For The Application, Installation and Maintenance of Solid State Control). The illustrations, charts, and layout examples shown in this manual are intended solely to illustrate the text of this manual. Because of the many variables and requirements associated with any particular installation, Allen-Bradley Company cannot assume responsibility or liability for actual use based upon the illustrative uses and applications. No patent liability is assumed by Allen-Bradley Company with respect to use of information, circuits, equipment or software described in this text. Reproduction of the contents of this manual, in whole or in part, without written permission of the Allen-Bradley Company is prohibited. Throughout this manual we make notes to alert you to possible injury to people or damage to equipment under specific circumstances.

!

ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss.

Attention helps you: - Identify a hazard - Avoid the hazard - recognize the consequences Important: Identifies information that is critical for successful application and understanding of the product.

4

Page 22

5

Page 23

Section

1A

Using This Manual

1A.0 Section Overview

This manual provides the information necessary to integrate the Allen-Bradley 9/Series control to a suitable machine tool. It begins with a system overview followed by sections covering mechanical and electrical system design to assist the system installer with component installation. The manual also includes electrical and mechanical specifications for all components of the controls. This section describes how to use this manual. Major topics include:

1A.1 Audience

Topic:

See page:

Audience

1A-1

Terms and Conventions

1A-2

Attentions and Important Information

1A-3

Related publications

1A-3

This manual presumes that the reader understands machine tools, basic wiring and electronics, and CNC control theory.

1A-1

Page 24

Section 1A Using This Manual

1A.2 Terms and Conventions

1A-2

To make this manual easier to read and understand, full product names and features are shortened where possible. Here are the shortened terms: When your see:

It Means:

AMP

Adjustable Machine Parameters

CNC

Computer Numerical Control

CPU

Central Processing Unit (the computing part of the (9/260 and 9/290 control)

CPU Board the board that holds the processor of the control. It slides into the enclosure to connect to the motherboard (9/260 and 9/290 control)

CRT

Cathode Ray Tube (the control’s monitor screen)

The Control general term that we use to refer to the 9/230, 9/260, 9/290 or 9/440 control.

E-STOP

Emergency Stop

Flash Memory

Non-volatile, programmable memory that resides in Flash SIMMs on the CPU board. This memory backs up the executive program, PAL, and AMP. It retains information even during power failure

HPG

Hand Pulse Generator

I/O

Input/Output

I/O CPU

One of two CPUs in the 9/290. It processes the machine logic interface and I/O control information.

Main CPU

One of two CPUs in the 9/290 and the only CPU in the 9/230 and 9/260. It processes internal CNC functions, including system scans and block decode.

MDI

Manual Data Input

MTB

Machine Tool Builder’s control panel

Motherboard the board that is installed onto the back panel of the enclosure on the 9/260 and 9/290. Most system connections are on this board.

ODS

Offline Development System

PAL

Programmable Application Logic

Processor Board the board that is installed onto the back panel of the enclosure on the 9/230. Most system connections are made on this board.

RAM

Random Access Memory

RIO

Allen Bradley Remote I/O communications.

SIMM

Single, In-line Memory Module. Flash SIMMs are on the lower half of the CPU module. If you have a 9/290, it has Shadow RAM SIMMs installed on the top half of the module as well as Flash SIMMs.

Softkeys

The row of keys directly below the Operator Panel screen

System Installer

The company or contractor responsible for installing this control on the machine

Workstation

The IBM or compatible personal computer that the ODS software is installed on

Page 25

Section 1A Using This Manual

1A.3 Attention and Important Information

We indicate vital information in these ways: ATTENTION: indicates circumstances or practices that can lead to damage to the control or other equipment.

Information that is especially important is indicated by the following: Important: indicates information that is necessary for successful application of the control.

1A.4 Related Publications

The following documents are also available: Pub. No.

Document Name

MCD-5.1

9/Series CNC Offline Development System User’s Manual

8520-4.3

9/Series CNC 9/230, 9/260, and 9/290 PAL Reference Manual

8520-5.1.1

9/Series CNC Lathe Operation and Programming Manual

8520-5.1.3

9/Series CNC Mill Operation and Programming Manual

8520-5.1.4

9/Series CNC Grinder Operation and Programming Manual

8520-6.4

9/Series CNC 9/230, 9/260, and 9/290 AMP Reference Manual

8520-6.5

9/Series CNC Transfer Line Quick Start Guide (Shipped with T-Line-9 only)

END OF SECTION

1A-3

Page 26

Section 1A Using This Manual

1A-4

Page 27

Section

1B

System Overview

1B.0 Section Overview

1B.1 System Configuration

This section provides an overview of the 9/230, 9/260, and 9/290 controls. Typical system configurations and the external appearance of each component of the control are provided in this section. Detailed information on each component is provided in specific sections in this manual. For Information on:

See page:

System Configuration

1B-1

System Configuration for 9/230 System

1B-2

9/230 Component Enclosure

1B-6

9/260 and 9/290 Component Enclosure

1B-7

Operator Interface

1B-8

Drives Interface

1B-11

I/O Interface

1B-12

Communication Interface

1B-15

Offline Development System

1B-15

Adjustable Machine Parameters (AMP)

1B-15

Programmable Application Logic (PAL)

1B-15

Fiber Optic I/O Ring

1B-16

Figure 1B.2 to Figure 1B.3 show three typical configurations for the 9/230, 9/260, and 9/290 controls. Use these figures for an overview of the inter-component connections you make during integration of the control.

1B-1

Page 28

Section 1B System Overview

Figure 1B.1 Typical System Configuration for 9/230 Power source

Enclosure

To on/off swithch on MTB Panel ac power video Main Power Supply

Mono/Color Operator Panel + 5V dc

+ 12V dc

MTB Panel

MTB Panel I/O Module E - stop reset RS - 232 or RS - 422

E - stop string 9/230

Remote I/O

Hand Pulse Generator ac/dc power 1746 I/O

Digital or Analog I/O

High Density I/O Module dc power 66 inputs 36 outputs to servo amplifiers from encoders indicates fiber optic cable

1B-2

19416

Page 29

Section 1B System Overview

Figure 1B.2 Typical System Configuration for the 9/260 Power source

To on/off switch on MTB Panel

Enclosure indicates fiber optic cable ac power video

Main Power Supply

Mono/Color Operator Panel +5 Vdc

+12 Vdc

MTB Panel

MTB Panel I/O Module

RS-232

E-Stop reset RS-232 OR RS-422

E-Stop string 9/260 Hand Pulse Generator

Remote I/O ac/dc power

1746 I/O

High Density I/O Module Servo Module

Digital or Analog I/O dc power 66 inputs 36 outputs

Fast I/O to servo amplifiers from encoders

Optional Feedback Module 1

11170-I from encoders 1 The optional feedback module is compatible only with digital servo modules. It cannot be used with analog modules.

1B-3

Page 30

Section 1B System Overview

Figure 1B.3 Typical System Configurationfor the 9/290 indicates fiber optic cable

Power source To on/off switch on MTB Panel ac power

Enclosure video

Main Power Supply

+5 Vdc

Mono/color Operator Panel +12 Vdc

MTB Panel

MTB Panel I/O Module

RS-232

E-Stop reset

RS-232 or RS-422 Remote I/O

E-Stop string

9/290

Hand Pulse Generator Hand Pulse Generator Digital I/O

Servo Module

Digital Servo Module

High Density I/O Module

Servo Module to servo amplifiers from encoders to servo amplifiers dc power 66 in 36 out

1 analog in 1 analog out

1771 I/O Adapter from encoders to servo amplifiers

Fast I/O

1746 I/O Adapter

1 The optional feedback module is compatible only with digital servo modules. It cannot be used with analog modules.

1B-4

20 in 12 out ac power

Analog I/O

Optional Feedback Module 1 from encoders ac/dc power ac/dc power

Digital or Analog I/O 11088-I