Page 621
I--2
Index
9/Series, PAL, PLC, SLC 5/03, SLC 5/04, DH+, and INTERCHANGE are trademarks of Allen-Bradley Company, Inc.
Allen-Bradley, a Rockwell Automation Business, has been helping its customers improve productivity and quality for more than 90 years. We design, manufacture and support a broad range of automation products worldwide. They include logic processors, power and motion control devices, operator interfaces, sensors and a variety of software. Rockwell is one of the world’s leading technology companies.
Worldwide representation. Argentina ·Australia ·Austria ·Bahrain ·Belgium ·Brazil ·Bulgaria ·Canada ·Chile ·China, PRC ·Colombia ·Costa Rica ·Croatia ·Cyprus ·Czech Republic · Denmark ·Ecuador ·Egypt ·El Salvador ·Finland ·France ·Germany ·Greece ·Guatemala ·Honduras ·Hong Kong ·Hungary ·Iceland ·India ·Indonesia · Ireland ·Israel ·Italy ·Jamaica ·Japan ·Jordan ·Korea ·Kuwait ·Lebanon ·Malaysia ·Mexico ·Netherlands ·New Zealand ·Norway ·Pakistan ·Peru · Philippines ·Poland ·Portugal ·Puerto Rico ·Qatar ·Romania ·Russia- CIS ·Saudi Arabia ·Singapore ·Slovakia ·Slovenia ·South Africa, Republic ·Spain · Sweden ·Switzerland ·Taiwan ·Thailand ·Turkey ·United Arab Emirates ·United Kingdom ·United States ·Uruguay ·Venezuela ·Yugoslavia
Allen-Bradley Headquarters, 1201 South Second Street, Milwaukee, WI 53204 USA, Tel: (1) 414 382-2000 Fax: (1) 414 382-4444
Publication 8520-6.2.11 - February 1997 Publication 8520-6.2.11 - February 1997
PN176030 Copyright 1996 Allen-Bradley Company, Inc. Printed in USA
Page 622
68 Rockwell sviomation
Allen-Bradley
9/Series Hardware TAB 12
Analog Servo Drive Connection
8520-6.2.12 - February 1996 PN-160485
Page 623
Section
12
Wiring A-B Analog Drives
12.0 Section Overview
This section discusses the wiring of Allen-Bradley Analog servo drive amplifiers. This manual is not intended to be used in place of documentation that accompanies an A-B drive but should be used with such documentation. The following table lists the Allen-Bradley drives supported by the control that are covered in this section. Table 12.A A-B Drives Selection Guide References A- B Drive
Publication No.
Figure No.
Title
1386
1386- 5.0
Figure 12.1
DC PWM Servo Drive (Multi-Axis)
1387B
1387-5.0
Figure 12.2
DC Spindle Drive (Analog) Product Data
1388
1388-5.1
Figure 12.3
DC PWM Servo Drive (Single Axis) Product Data Series B
1389
1389-5.1
Figure 12.5
AC Servo Amplifier (Multi- Axis) Product Data
1391
1391-5.0
Figure 12.6
AC Servo Amplifier (Single Axis) Product Data
1392
1392-5.1
Figure 12.4
High Performance AC Drive (460V and 230V) Product Data
For digital drive systems, refer to sections beginning on page 13A-1 (for 8520 systems) or page 11A-1 (for 1394 systems). For non A-B analog drives, refer to documentation prepared by the drive manufacturer along with the analog specifications given in this manual for your specific processor. The figures in this section emphasize the wiring between the termination panel and E-STOP string to the drives. They do not show complete detailing of the drives. You should have your drive manual handy when you use these figures.
12-1
Page 624
Section 12 Wiring A-B Analog Drives
Figure 12.1 Wiring Diagram for Series 1386 Drives DRIVE
TB1 See note 2
DRIVE DR RET SHLD 1771 HTE Encoder Termination Panel
1 Diff + 2 Diff 3 Signal Common 4 Aux 5 Tach 6 Signal Common
See note 1
TB2 1 Decoupled Curr 2 Sig Common 3 Reset 4 Interlock 5 Signal Clamp 6 Signal Clamp + 7 Signal Clamp Ref
If your control has terminal 8, then connect it to chassis ground. If terminal 8 is not present on your control, then this type of grounding is not necessary.
J1 + 15V dc
8 7 6
E-STOP Status Relay Contact connection
Common - 15V dc
5 Drive OK Board
4
1386 - AA
Servo Amplifier
Reset 3 Common 2 E-STOP 1
Connection to MTB Panel E-STOP and E-STOP Reset
Motherboard (9/260 and 9/290) or Processor board (9/230) terminal block BT1
Other user defined E-STOP Devices
Axis overtravel
Remote E-STOP Button
1386 - M
Chassis
Encoder 1 Motor
Motor Power Terminal Block
NOTE 1. We recommend installation of this connection. Remove it if excessive noise from chassis ground occurs. 2. The connection from the termination panel to the drive should be as short as possible. We recommend less than 20 ft. 11368-I
12-2
Page 625
Section 12 Wiring A-B Analog Drives
Figure 12.2 Wiring Diagram For Series 1387B Drives If your control has terminal 8, then connect it to chassis ground. If terminal 8 is not present on your control, then this type of grounding is not necessary.
115V ac
User Power to drive logic
Status relay power
1387B Servo Amplifier (see note 1)
8
E-STOP status relay
7 6
21 23 25
37
Coast/DB Stop Internal tie Point High Accel/decel Rate Internal Logic Power
39
Enable Input
1
Run Reference (+)
3 5
Run Reference (- ) Shield
8
Common
TB5
Fault
TB5
27
5
34
4 Reset 3
Connection to MTB Panel E-STOP and E-STOP Reset
Common 2
Velocity Command
E-STOP 1 See note 3
Motherboard (9260 and 9/290) or Processor Board (9/230) terminal block BT1
Control Power High Control Power Low
48 50
DRIVE
TB2
TB1
DRIVE DR RET SHLD See note 2
1771 HTE Encoder Termination Panel
Remote E-STOP
Axis Overtravel
NOTE: 1. The control works only with 1387 drives that use 115V ac and have the dynamic braking option. Refer to Bulletin 1387 User Manual (Publication 1387-5.0) for power wiring and motor connection.
Motor Thermal Overload
Drive XFMR Thermal Overload
2. We recommend installation of this connection. Remove it if excessive noise from chassis ground occurs. 3. The connection from the termination panel to the drive should be as short as possible. We recommend less than 20 ft.
12-3
Page 626
Section 12 Wiring A-B Analog Drives
Figure 12.3 Wiring Diagram For Series 1388 Drives If your control has terminal 8, then connect it to chassis ground. If terminal 8 is not present on your control, then this type of grounding is not necessary.
Status relay power
E-STOP status relay 240/480V AC 3 Phase 50/60Hz
8 7
H1 H4 H7
Bulletin 1388 Power Transformer
Y1 Y2 Y3
X1 X2 X3 X0
P1 P2
G0
6 5 4 Reset 3
Thermal Switch
Connection to MTB Panel E-STOP and E-STOP Reset
Common 2 E-STOP 1
T1
T2
A2
Tach Motherboard (9260 and 9/290) or Processor Board (9/230) terminal block BT1
Velocity Command
DRIVE DR RET SHLD
Note 2
Note 1
Axis Overtravel
NOTE: 1. We recommend installation of this connection. Remove it if excessive noise from chassis ground occurs. 2. The connection from the termination panel to the drive should be as short as possible. We recommend less than 20 ft.
12-4
P1 P2 M
Remote E-STOP
A1
Motor A3TB1
DRIVE
1771 HTE Encoder Termination Panel
120V ac 3 phase 50/60 Hz
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
A2TB1
4
5
Bulletin 1388 DC Servo Amplifier
+ 23V dc CR1 Drive Fault
CR1
7
8
9
Page 627
Section 12 Wiring A-B Analog Drives
Figure 12.4 Wiring Diagram For Series 1392 Drives If your control has terminal 8, then connect it to chassis ground. If terminal 8 is not present on your control, then this type of grounding is not necessary.
Status relay power +24V
8 7
E-STOP status relay
-
+
1
+ Speed Ref.
2
- Speed Ref.
6
3
5
4
4
5
Coast to Stop
6
Drive Enable
7
External Reset
8
Customer 0 Volts
9
Drive Ready
Reset 3
Connection to MTB Panel
Common 2
E-STOP and E-STOP Reset
E-STOP 1 Motherboard (9260 and 9/290) or Processor Board (9/230) terminal block BT1
10
Ground Stud Bulletin 1392 Servo Amplifier (Standard Parallel Interface J9 Main Control Board)
E-STOP string Remote E - stop Note 1 DRIVE DR RET SHLD CH A. HI CH A. L O A B SHL D CH B. HI CH B. L O Z SHL D CH Z. HI CH Z. L O
T1 T2 Axis Overtravel Motor Thermal Switch
P1 P2 Transformer Thermal Switch
Velocity Command
DRIVE
Note 2
Encoder Fanout Customer Outputs
Cust + 12V
CH CH CH CH CH CH A A’ B B’ Z Z’
Cust 0 Volts
78 77 76 75 74 73 72 71
ENCODER
1771 HTE Encoder Termination Panel NOTE: 1. We recommend installation of this connection. Remove it if excessive noise from chassis ground occurs. 2. The connection from the termination panel to the drive should be as short as possible. We recommend less than 20 ft.
+12V Power Supply (user -supplied)
12-5
Page 628
Section 12 Wiring A-B Analog Drives
Figure 12.5 Wiring Diagram For Series 1389 Drives A B System Ground Frame G2
G1
G0
X0
C 230V ac
Main Disconnect/Fuses
X1
H1
M1
TB1 - 2
M1
TB1 - 3
M1
TB1 - 7
230V ac
TB1 - 8
X2 If your control has terminal 8, then connect it to chassis ground. If terminal 8 is not present on your control, then this type of grounding is not necessary.
X3
H4
+240/480V ac 3 phase
Y1
H7 Status relay power
8
1389 Isolation Transformer
Control Transformer
120V ac F
7
Y2 P1
P2
TB2 - 1
Thermal Transformer Switch
M1
6
TB2 - 2 TB2 - 3
E-STOP status relay
5
TB2 - 5 TB2 - 6
Common 2 E-STOP 1
Connection to MTB Panel
TB2 - 7
E-STOP and E-STOP Reset
TB2 - 9
Motherboard (9260 and 9/290) or Processor Board (9/230) terminal block BT1
TB2 - 8
E-STOP String
Axis Overtravel (Extreme)
Note 1
Remote E-STOP
DRIVE DRIVE DR RET SHLD - Ref
T1
Motor Thermal Switch (see T1, T2 on Bulletin 1326 Servo Motor)
P1
Enable Source Enable Source Enable Source Enable Source System OK
P2
Transformer Thermal Switch (see P1, P2 above) Power Supply
+ Ref Velocity Command
1771 HTE Encoder Termination Panel
Note 2 NOTE: 1. We recommend installation of this connection. Remove it if excessive noise from chassis ground occurs.
P A G E Bus UV (isolated)
TS T2
N E X T
Reset Return
TB2 - 10 MT
O N
Reset
TB2 - 4
4 Reset 3
TB1 - 1
D E F
2. The connection from the termination panel to the drive should be as short as possible. We recommend less than 20 ft. 11372-I
12-6
C O N T I N U E D
Page 629
Section 12 Wiring A-B Analog Drives
Figure 12.5 (continued) Wiring Diagram For Series 1389 Drives GND
A B
T1
Chassis Ground Stud
C
T2 1389 Drive Servo Amplifier
J1 - 3
J1 - 5
TB3 - 1 TB3 - 2
Motor Thermal Switch
BK1 Brake Option
BK2 A
J1 - 1
J1 - 1,4,7
MT
+
TB3 - 3
B
Motor
C J1 - 2
J1 - 3,6,9
-
TB2 - 1 (Rotor 1) TB2 - 2(Rotor 2)
J1 - 2
TB2 - 3 (Shield) TB2 - 4 (Sine 1)
J1 - 8
TB2 - 5 (Sine 3) TB2 - 6 (Shield) TB2 - 7 (Cos 4) TB2 - 8 (Cos 2) J2 - 1
J2 - 1,4
J2 - 2
J2 - 3,6
J2 - 3
J2 - 7
J2 - 4
J2 - 8
J2 - 5
Power Supply D
J2 - 6 Chassis Module
Rotor 2 (Yel/Wh)
Blk
- 12V Common
Sys Enable
Ref +
Sys Velocity Pur Command Axis Fault Torque Clamp CMD
Ref Shield Pos Source Pos RTN Neg Source
1 Limit CMD Drive OK (isolated)
SINE 1 (Red)
Red Blk Grn
SINE 3 (Blk) COS 2 (Yel)
Resolver
COS 4 (Blue)
TB1 - 1 Tach Output
Neg RTN
E F
Wht
TB2 - 10 (Shield)
GND
J2 - 9
Rotor 1 (Red/White)
TB2 - 9 (Shield)
+12V J2 - 2,5
Blk
Shield N.C. Bulletin 1326 Servo Motor
TB1 - 2 ICMD and Torque Monitor TB1 - 3 TB1 - 4 TB1 - 5 TB1 - 6 TB1 - 7 TB1 - 8 TB1 - 9 TB1 - 10
Source
TB1 - 11
CMD
TB1 - 12
RTN
TB1 - 13 TB1 - 14 TB1 - 15 11372b-I
12-7
Page 630
Section 12 Wiring A-B Analog Drives
Figure 12.6 Wiring Diagram For Series 1391 Drives A
If your control has terminal 8, then connect it to chassis ground. If terminal 8 is not present on your control, then this type of grounding is not necessary.
B
Status relay power
8
E-STOP status relay
TB4
7
TB4
6
C 11 12
5
TB4
13
4
TB4
14
TB4
15
TB4
16
Reset 3
Connection to MTB Panel E-STOP and E-STOP Reset
Common 2 E-STOP 1
Note 2 Velocity Command
Motherboard terminal block BT01
TB4
17
TB4
18
TB4
22
TB2
1
TB2
2
M
115V ac
N E X T
M
TB2 TB2
DRIVE DR RET SHLD
TB2 TB2
DROK (closed = OK)
+ Ref
+
9
NOTE: 1. We recommend installation of this connection. Remove it if excessive noise from chassis ground occurs. 2. The connection from the termination panel to the drive should be as short as possible. We recommend less than 20 ft.
12-8
Enable Source
10 Enable Input 11 12 Bulletin 1391 Servo Amplifier
Note 1 1771 HTE Encoder Termination Panel
Remote E-STOP
Axis Overtravel
P A G E
120V ac 1 amp
+23V d c DRIVE
O N
M
- Ref
C O N T I N U E D
TB4 TB4 18 17
K1 K2
DROK See Bulletin 1391 Drive above
See Bulletin 1326 Motor above
D P1 P2
See Drive Transformer above