Section 14A System Start-Up

1394 Drive Power terminal block W1 and W2 24 V ac or dc and check test points on the wiring board: TB3 Test Point

Voltage

TB3-1

+5V dc

TB3-2

Common

TB3-3

+15Vdc

TB3-4

- 15Vdc

The status LEDs on the axis modules should flash red and green alternately, indicating the system is ready and waiting for full bus voltage. The Status LED on the system module should be red. The system module LED only illuminates when a fiber optic ring fault occurs. It should be off anytime the CNC is powered up. 9/440 CNC/drive systems Assuming you wired your 9/440 as discussed starting on page 5A-28, power should be applied to your on/off control assembly but no drive power should be present. Both 24 V logic power and three phase should not be available to the system module at this point. After performing the above checks: 7.

Make sure the E-Stop button is depressed. Using the “ON” button on the MTB panel, turn on power to the control. The main menu screen should appear after the CRT warms up. For 1394 systems, the system module LED should turn off provided the fiber optic ring is functioning correctly. On 9/440 CNC systems, the status LED as well as the Xilinx and Watchdog LED should all be on.

8.

If using a 1394 digital drive (not available for 9/440 CNC) check the 1394 I/O device monitor page to check fault status and addressing (see page 15A-29).

9.

Using ODS, assign the AMP parameter values for each axis, then download the prepared AMP file to the control. Refer to the download section in the AMP manual for more information on downloading AMP files.

10. Download a “minimum” PAL program to the control. Refer to the download section in the PAL manual for more information on downloading a PAL program. This program should contain basic rungs to handle MTB panel, E-Stop, axis unclamp, etc. 14A-3

Page 692

Section 14A System Start-Up

Important: The control will not come out of E-Stop if there is no PAL program available for execution. 11. If the error message “SERVO POWER UP SEQUENCE ERROR” is displayed on the operator panel CRT, verify that the AMP parameters match the servo cabling. 12. Verify polarity of position feedback. Access the axis monitor page. Feedback should count up when the axis is moved in the positive direction and count down when the axis is moved in the negative direction, when the encoder/resolver is installed. This is all relative to axis direction assignment, rotation direction changes through gearing, and encoder phasing. Manually rotate the feedback device, check the axis direction and corresponding feedback count. If the feedback count is counting up when it should be counting down or counting down when it should be counting up, then the value of AMP parameter SIGN OF POSITION FEEDBACK should be changed to Minus. 13. Verify polarity of velocity feedback. On analog systems and digital systems with one feedback device, the AMP parameter SIGN OF VELOCITY FEEDBACK should always be the same as SIGN OF POSITION FEEDBACK. On the system with more than one feedback device, velocity feedback polarity should be determined by turning the motor shaft and watching the sign of axis monitor display parameter for Average Velocity Error. 14. Do a position calibration check. With the control in E-Stop, rotate the servo until the marker found is indicated on the monitor page. Record the position. While remaining in E-Stop, rotate the servo until the axis moves a measured distance. Record the monitor position. If the difference in monitor readings did not reflect the correct axis displacement, AMP must be adjusted. Typically this is the result of either axis calibration errors, incorrect number of position feedback counts/rev entered, or incorrect gear ratio between gear on motor shaft/lead screw thread pitch, etc... 15. If no error messages are displayed on the operator panel CRT, push the E-Stop Reset button on the MTB panel. Check the CRT for messages and watch for motor rotation. There should be no error messages or motor rotation. If a motor rotates without a command, immediately push the E-Stop button and check the motor and encoder wiring for correct phasing.

14A-4

Page 693

Section 14A System Start-Up

16. Check the 3 Æ V ac incoming power to the servo amplifiers. For an analog system refer to documentation provided by the drives manufacturer. For a digital drive system, verify that the voltages listed below are present at the following terminals of the servo amplifier using a volt meter: 8520 Drives TB1-1 to TB1-2

170 to 253 V ac

TB1-1 to TB1-3

170 to 253 V ac

TB1-2 to TB1-3

170 to 253 V ac

The green SYSTEM READY indicator light should be illuminated. The yellow BUS UNDER VOLTAGE indicator light should be off. 1394 and 9/440 CNC/Drives Power terminal block U to PE 324 -- 528 V ac V to PE 324 -- 528 V ac W to PE 324 -- 528 V ac The green axis module LEDs should now be solid green (not flashing). 17. Select manual jog mode and jog the selected axis at low speed. Check that the motor rotates with a low jog speed in the selected jog direction. If the motor speed is correct but the motor rotation direction is incorrect, change the AMP parameter SIGN OF POSITION FEEDBACK for the selected axis to the opposite polarity setting. Change the parameter SIGN OF VELOCITY FEEDBACK if it no longer matches SIGN OF POSITION FEEDBACK. Download the new version of AMP to the control. If the motor rotation direction is correct but the motor speed is uncontrollable, check that the feedback wiring at the servo module matches the phasing leads. Check the wiring from the power amplifier to motor and from motor feedback to servo module.

14A-5

Page 694

Section 14A System Start-Up

18. Mechanically connect the motors to the axes. If configuring a split axis the encoder marker alignment procedure must be performed before proceeding. This procedure may require you to leave your servos mechanically disconnected from the axis. Refer to page 14B-1 for details on aligning markers on a split axis. ATTENTION: If configuring a split axis make sure that the axis is reconfigured with Deskew and homed before proceeding. Do not attempt to home the split axis unless the marker alignment procedure has been completed as discussed on page 14B-1.

19. Select incremental jog mode and jog the selected axis a known distance. Check that the motor rotates the correct numbers of turns and the machine moves the correct distance. If it does not, check the AMP parameters LEAD SCREW THREAD PITCH, TEETH ON GEAR FOR POSITION FEEDBACK and TEETH ON LEAD SCREW FOR POSITION FEEDBACK. If any adjustments are made, download the new version of AMP to the control. 20. Adjust the AMP parameters INITIAL GAIN OF POSITION LOOP, GAIN BREAK POINT, ACC/DEC RAMP and other motor specific parameters necessary to properly tune your system. After each adjustment, download the new version of AMP to the control. Continue to adjust these parameters until the desired response curve is obtained with no overshoot at various levels of cutting speeds. 21. Check the velocity response at various levels of the jog feedrate. Adjust the AMP parameter ACC/DEC RAMP until the control can be accelerated and decelerated without any problems. After each adjustment, download the new version of AMP to the control. 22. Using the value obtained for the INITIAL GAIN OF POSITION LOOP parameter, determine and enter correct values for the AMP parameters: INPOSITION BAND FEEDRATE SUPPRESSION POINT EXCESS ERROR 23. Download the new version of AMP to the control. 24. Repeat this procedure for each axis.

14A-6

Page 695

Section

14B

Integrating a Split Axis with Deskew

14B.0 Section Overview

A split axis is a single axis that, due to size or precision requirements, is positioned by two separate servo motors. This section describes the servo connections, start up procedure, home marker alignment and motion considerations for a split axis. Figure 14B.1 Split Axis Configuration Lead screw

Servo motor (master) Encoder “Split Axis” - One moving axis controlled by two completely separate servo motors.

AXIS

Encoder Servo motor (slave)

Lead screw

ATTENTION: Verify that you have purchased a control with the split axis option. If you configure a split axis (using deskew parameters in AMP) and your control is not equipped with the split axis option, the control will not come out of E-Stop.

14B-1

Page 696

Section 14B Integrating a Split Axis with Deskew

Skew is the difference between the position of the split axis master servo and the split axis slave servo. If the skew is too large, the axis or its drive components may be damaged due to mechanical binding. To minimize axis skew, there are a number of “Deskew” parameters that are configured through AMP. The Deskew parameters are used to assign the master and slave axes, and to prevent damage from axis misalignment.

14B.1 Split Axis Servo Connections

Wire the servos motors of the split axis up to the servo module ports as defined in AMP. Wiring requirements are outlined starting on page 7A-1 of this manual. When configuring servo ports keep the following in mind. If then the slave and the master servo

A spindle is configured to a port:

must be connected to the port directly before the spindle (spindle must be last port used on a system)

can be connected to any port before the slave port

A spindle is not configured to a port:

must be connected to the last port used in the system can be connected to any port before the slave port

Port configuration is defined in AMP with the servo parameters. Your wiring must match your AMP configuration. Servos are designated as slave or master axes through the AMP Deskew parameters. An example of the port assignments for a three axis system with a spindle and a split axis is shown below. This configuration uses two analog servo modules so that there are enough ports to provide output to the drives for the master and slave servo motors that move the X axis.

14B-2

Port Connector

Axis Name (name of servo)

Configuration

J1

X

Configured as Deskew Master Servo Name

J2

Y

Normal Servo Configuration

J3

Z

Normal Servo Configuration

J1 (second module)

U

Configured as Deskew Slave Servo Name

J2 (second module)

C

Configured as Spindle

Page 697

Section 14B Integrating a Split Axis with Deskew

14B.2 Split Axis Start up Procedure

The start up procedure for a split axis requires that both servos be tested separately. This means mechanically disconnecting the drive train of both servos and temporarily redefining them as independent axes in AMP. This can be done by setting the master and slave servo names in the AMP Deskew parameter group to “none”. Remember, AMP changes can be made either in ODS or through Patch AMP. Once you have disconnected and redefined the split axis servo motors, perform the Initial Control and Servo Start Up Procedures starting on page 14A-1. ATTENTION: Do not perform any homing operations during this start up procedure. Special homing considerations are given in the following section.

At step 18. of the start up procedure (on page 14A-6) you are instructed to complete the homing marker alignment if you are working on a split axis. At that point, return to the alignment procedure starting on page 14B-3 of this section. After you complete the marker alignment, you can return to step 19. (on page 14A-6) and complete the start up procedure.

14B.3 Split Axis Marker Alignment

To assure that minimal skew exists between servos of a split axis it is imperative that as small amount of skew as possible exists after the axes are homed. Once homed with minimal skew, the control can make sure the master and slave servo’s positions relative to each other remains constant. This requires that both servos of a split axis return to the same repeatable home position. ATTENTION: Do not attempt to perform this procedure until the normal start up procedure has been started as discussed in the previous section.

At this point, you should have completed through step 18. of the start up procedure in 14A-6. You should have mechanically reconnected both servo motors to the axis and redefined those servos as master and slave using the AMP Deskew parameters. Both servos of a split axis home off of the same single home switch. The homing sequence is almost the same for an axis with deskew as it is for a single servo axis. The axis moves to the switch, stops, moves off of the switch in the AMP specified direction, stops again, and then moves to the nearest encoder null marker.

14B-3

Page 698

Section 14B Integrating a Split Axis with Deskew

The difference for a split axis is that the distance to the nearest marker is calculated independently for the two servos and their home calibrations are configured separately. The move to the calibrated home position is calculated and executed independently and simultaneously on the master servo and slave servo. In order for this home position for both servos to be one where minimum axis skew exists, it is necessary to align encoder markers. The recommended method of aligning markers is as follows: 1.

Physically position the axis so that minimal skew exists. Measure skew on the axis with a precision square, dial indicator, or any device you find to be the most precise for your application.

2.

Turn power to the control off and on again. When power is turned back on the servos will assume that they are in position and will hold the axis at minimal skew. ATTENTION: Do not home the axis at this time. Any attempt to home the axes can result in large skew error and damage the servo drive components.

3.

14B-4

Access the axis monitor screen using the following softkey strokes. a. Press the [SYSTEM SUPORT] softkey. b. Press the [MONITOR] softkey. c. Press the [AXIS MONITOR] softkey.

Page 699

Section 14B Integrating a Split Axis with Deskew

Figure 14B.2 Axis Monitor Screen

AXIS MONITOR

X AXIS [ MM ]

SETUP MODE

FOLLOWING ERROR

0.0000

DISTANCE

0.0000 0

TO MARKER AVERAGE VEL ERROR

0

TORQUE

SKEW

%

0.0000

X AXIS

Y AXIS

IN-POSITION

MARKER NOT FOUND

Z AXIS

4.

Find the encoder marker for the master servo. First select the master axis name from the softkeys so that you are looking at data for the master axis. Then slowly jog the split axis (using the axis name defined in AMP as the master axis) while watching the lower right hand corner of the axis monitor screen. Jog the axis only until “marker found” is displayed.

5.

Find the encoder marker for the slave servo. This time select the slave axis name from the softkeys so that you are looking at data for the slave axis. Then slowly jog the split axis (still using the axis name defined in AMP as the master axis) while watching the lower right hand corner of the axis monitor screen. Again, jog the axis only until “marker found” is displayed.

6.

Physically secure the axis so that it cannot be moved. Use weights, clamps, or whatever is necessary to prevent axis skew from occurring while you work on the encoders.

7.

Place the control in E-Stop and verify that power to the drives is turned off.

14B-5

Page 700

Section 14B Integrating a Split Axis with Deskew

8.

Loosen the encoders for both servos. In most cases, you can loosen the encoder casing from its mounting without disengaging the encoder shaft. This way you can rotate the encoder and change its position reading without moving the axis.

Important: On all digital servo motors and some analog servo systems, rotation of the encoder relative to the motor is not possible. The encoder is mounted relative to the motor shaft at a specific location and cannot be moved. In these cases it is necessary to disconnect the servo drive linkage and rotate the motor shaft to align encoder markers. 9.

Align the two servos’encoder markers. Align the encoder markers by rotating the encoder casing until the DISTANCE TO MARKER value on the display for each servo is as close to the same value as possible. Refer to Figure 14B.3.

Figure 14B.3 Aligning Master and Slave Encoder Markers

CORRECT

INCORRECT

Master and slave encoder markers are aligned within a few counts of eachother MASTER

SLAVE

Master and slave encoder markers are not aligned, resulting in a significantly different distance to marker between the servos when homing.

MASTER

SLAVE

10. Tighten the encoders for both servos. This will assure that both servos are approximately the same distance from their markers when there is minimal axis skew. 11. Loosen the clamps or remove the weight you used to secure the axis in step 6. 12. Turn power to the control off and then back on again. When power is turned back on the servos will assume that they are in position and will hold the axis at minimal skew, this time with encoder markers aligned.

14B-6