Page 1 of B & R Automation IF311 and IF321 Spec Sheet

Spec sheet · B & R Automation

B & R Automation IF311 and IF321 Spec Sheet

Spec sheet2 pagesPDF 272 KB

Both pages are below, each with its text.

Download the PDF272 KB

Covers · 2 models

The models it covers

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

This two-page B&R 2003 Modules data sheet covers two screw-in interface modules: the IF311 with one RS232 port and the IF321 with one isolated RS485/RS422 port. It gives technical data, the pin assignments of both 9 pin connectors and the IF321 bus termination switch.

What it is
IF311: B&R 2003 screw-in module with 1 RS232 port; IF321: 1 RS485/RS422 port, electrically isolated, network capable p. 1
Model numbers
IF311: 7IF311.7; IF321: 7IF321.7 p. 1
Slot
CP interface, slots 1, 2 and 3 p. 1
Connector
IF311: 9 pin D-type plug; IF321: 9 pin D-type socket p. 2
Baud rate
Max. 115.2 kBaud, set in software p. 1
Distance
IF311: 15 m at 19200 Baud; IF321: 1200 m without repeater p. 1
Panel supply
IF311: +5 VDC, max. 500 mA on pin 4 for simple PANELWARE controllers such as the P120 p. 1, 2
Power consumption
IF311: max. 0.5 W, max. 1.6 W with P120 / P121; IF321: max. 1.4 W p. 1
Handshake lines
IF311: RTS (pin 7) and CTS (pin 8) p. 1, 2
Bus termination
IF321: built-in termination resistor switched on and off p. 2
Remote bus connector
IF321: remote bus connector 0G1000.00-090 can be used p. 2

What this sheet walks you through

  • IF311 RS232 pin assignment p. 2
  • IF321 RS485 and RS422 pin assignment p. 2
  • Switching the IF321 bus termination resistor p. 2

Good to know

  • Wiring remote I/O networks is described in another chapter of the B&R 2003 manual, not on this sheet. p. 2

Questions this sheet answers

What is the difference between the B&R IF311 and IF321?

The IF311 has one RS232 port; the IF321 has one electrically isolated, network capable RS485/RS422 port. p. 1

How long can the cable be on an IF321?

Up to 1200 m without a repeater; the IF311 RS232 port reaches 15 m at 19200 Baud. p. 1

What is the IF311 RS232 pinout?

Pin 2 RXD, pin 3 TXD, pin 4 +5 VDC panel supply, pin 5 GND, pin 7 RTS, pin 8 CTS; pins 1, 6 and 9 are not connected. p. 2

Does the IF321 have a termination resistor?

Yes, a built-in bus termination resistor turned on and off with a switch. p. 2

The file

Size and text

Pages2
PDF272 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of B & R Automation IF311 and IF321 Spec Sheet

The text of page 1, from the PDF itself

14.2 IF311 / IF321 14.2.1 Technical Data

Module IDIF311IF321

General Information Model Number

7IF311.77IF321.7Short Description

2003 interface module, 1 RS232 interface, screw-in module

2003 interface module, 1 RS485/RS422 interface, electrically isolated, network capable, screw-in module

C-UL-US ListedYesYesB&R ID Code$18

Module Type Slot Power Consumption

$16 B&R 2003 screw-in module CP Interface, slots 1, 2 and 3

Max. 0.5 W max. 1.6 W with P120 / P121 1)

Max. 1.4 WRS232RS485/RS42 2)

Standard Communication Interface Interface Type Electrical Isolation Interface - PCC Design Handshake Lines

NoYes9 pin D-type plug9 pin D-type socket

RTS, CTS, - Baudrate 2)

Max. 115.2 kBaudMax. 115.2 kBaudDistance15 m at 19200 Baud

1200 m (without repeater)

No

Yes

5 to 8 yes / no / even / odd 1/2

7/8 yes / no / even / odd 1/2

Network Capable Data Formats Data Bits Parity Stop Bits Mechanical Characteristics Dimensions 1) 2)

B&R 2003 screw-in module

Integrated power supply on pin 4 of the RS232 interface for simple PANELWARE controllers, e.g. P120. Can be configured using software.

416IF311 / IF321Chapter 3

Page 2 of B & R Automation IF311 and IF321 Spec Sheet

The text of page 2, from the PDF itself

14.2.2 Pin Assignments IF311

Assignment9 pin D-type plug 6915PinRS2321NCReserved2RXDReceive Signal3TXDTransmit Signal4+5 VDC /max. 500 mAPanel Supply5GNDGround6NCReserved7RTSRequest To Send8CTSClear To Send9NCReservedPinRS485RS4221NCNC2NCTXD3DATARXD4NCNC5GNDGND6+5 VDC / 50 mA+5 VDC / 50 mA7NCn_TXD8n_DATAn_RXD9NCNC

Chapter 3 B&R 2003 Modules

14.2.3 Pin Assignments IF321 Assignment

9 pin D-type socket 9651

14.2.4 Bus Termination Resistance IF321 The IF321 is equipped with a bus termination resistor. The resistance is turned on and off with a switch.

Using the remote bus connector 0G1000.00-090 is possible. Wiring remote I/O networks is described in Chapter 2 "Project Planning and Installation", section "Remote I/O Bus".

B&R 2003 ModulesIF311 / IF321417