The text of a spec sheet · part 1 of 1

Q60AFV Series Sensors with Visible Red Emitter: Self-Contained Adjustable-Field Sensors, pages 1 to 8

Pages 1 to 8 of 8

The original document is the PDF (692 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Banner Q60BB6AFV1000Q

Page 1

Q60AFV Series Sensors with Visible Red Emitter Self-Contained Adjustable-Field Sensors

Q60AFV Adjustable-Field Features • Adjustable-field background suppression sensor detects objects within a defined sensing field, while ignoring objects located beyond the sensing field cutoff • Two-turn, logarithmic adjustment of sensing field cutoff point from 0.2 to 1 m; allows easy setting of cutoff point at long range • Rotating pointer indicates relative cutoff point setting • Easy push-button or remote programming of light/dark operate and output timing; continuous status indicators verify all settings at a glance • Output ON and/or OFF delays adjustable from 8 milliseconds to 16 seconds • Powerful, highly collimated visible red sensing beam • Tough ABS/polycarbonate blend housing is rated IEC IP67; NEMA 6 10-30V dc Models (Q60BB6AFV): • Powered by 10 to 30V dc; bipolar (one NPN and one PNP) outputs • Available with integral cable or rotating Euro-style quick-disconnect fitting Universal Voltage Models (Q60VR3AFV): • 12-250V dc or 24-250V ac, 50/60 Hz • Available with integral cable or rotating Micro-style quick-disconnect fitting Visible Red, 665 nm

Q60 Adjustable-Field Models Minimum Range

Models

Cutoff Point

Cable*

Q60BB6AFV1000

5-wire 2 m (6.5')

Q60BB6AFV1000Q

5-pin Euro-style QD

Q60VR3AFV1000

Q60VR3AFV1000Q1

65 mm to 130 mm Adjustable: (2.5" to 5") 200 mm to 5-wire depending 1000 mm 2 m (6.5') on cutoff (8" to 40") point setting

4-pin Micro-style QD

Supply Voltage

Output Type

10-30V dc

Bipolar NPN/PNP

Excess Gain at 200 mm Cutoff

Excess Gain at 1000 mm Cutoff

10000

10000

1000

1000

Q60AFV

Universal Voltage 12-250V dc or 24-250V ac

E/M Relay (SPDT), normally closed and normally open contacts E/M Relay (SPST), normally open contact

E X C E S S G A I N

Q60AFV

E X C E S S

100

10

1 1 mm 0.04 in

G A I N 10 mm 0.4 in

100 mm 4 in

DISTANCE

1000 40 in

100

10

1 1 mm 0.04 in

10 mm 0.4 in

100 mm 4 in

1000 mm 40 in

DISTANCE

* 9 meter cables are available by adding suffix “W/30” to the model number of any cabled sensor (e.g., Q60BB6AFV1000 W/30). A model with a QD connector requires a mating cable; see page 8.

!

WARNING . . . Not To Be Used for Personnel Protection Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.

These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.

Printed in USA

02/12

P/N 69622 rev. B

Page 2

Q60V Series Adjustable-Field Sensors – Visible Red Emitter Q60AFV Overview The Q60AFV sensor is a full-featured adjustable-field sensor. These adjustable-field sensors are able to detect objects of relatively low reflectivity, while ignoring other objects in the background (beyond the cutoff point). The cutoff distance is mechanically adjustable, using the 2-turn adjustment screw on the sensor top (Figure 1). A rotating pointer indicates the relative cutoff position. (The indicator moves clockwise to show increasing distance.)

ON/OFF Delay Push Buttons and Indicators

Indicators Below Also Function as a 5-Segment Light Bar During Delay Selection Modes

Cutoff Adjustment Screw

Light Sensed Indicator Light Operate Selected Push Button Lockout Indicator

Two push buttons (ON Delay and OFF Delay) are used to set the output delay options, to toggle between light and dark operate modes and to lock out the push buttons for security purposes. These functions also may be accomplished using the remote wire. Seven LED indicators show, during RUN mode, the sensor configuration and operating status. During Delay Configuration, 5 of the LEDs combine to form a single light bar that indicates relative ON or OFF delay time. Adjustable-Field Sensing, Theory of Operation In operation, the Q60AFV compares the reflections of its emitted light beam (E) from an object back to the sensor’s two differently-aimed detectors R1 and R2 (see Figure 2). If the near detector (R1) light signal is stronger than the far detector (R2) light signal (see object A, closer than the cutoff distance), the sensor responds to the object. If the far detector (R2) light signal is stronger than the near detector (R1) light signal (see object B, object beyond the cutoff distance), the sensor ignores the object.

Dark Operate Selected Output Conducting (Bi-color Amber/Green)

Figure 1. Q60V features Cutoff Distance Receiver Elements Near R1 Detector

Lenses

Far R2 Detector

The cutoff distance for Q60AFV sensors is adjustable from 200 to 1000 millimeters (8" to 40"). Objects lying beyond the cutoff distance are ignored, even if they are highly reflective. However, it is possible to falsely detect a background object, under certain conditions (see Background Reflectivity and Placement, page 3). In the drawings and discussion on this page and page 3, the letters E, R1, and R2 identify how the sensor’s three optical elements (Emitter “E”, Near Detector “R1”, and Far Detector “R2”) line up across the face of the sensor. The location of these elements defines the sensing axis (see Figure 3). The sensing axis becomes important in certain situations, such as those illustrated in Figures 8 and 9.

Object B or Background

Object A

E

Sensing Range

Figure 2. Adjustable field sensing concept

Receiver Elements Emitter

When an object approaches from the side, the most reliable sensing usually occurs when the line of approach is parallel to the sensing axis.

Sensing Axis

Figure 3. Q60V sensing axis page 2

Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164

Page 3

Q60V Series Adjustable-Field Sensors – Visible Red Emitter Sensor Setup Target

Background

Setting the Cutoff Distance The cutoff distance for Q60AFV sensors may be adjusted between 200 mm and 1000 mm (8" to 40").

R1 R2 E

Cutoff Distance s

NOTE: Setting the cutoff distance adjustment screw to its maximum clockwise position places the receiver lens directly in front of the receiver elements and results in the Q60 performing as a long-range diffuse sensor.

ce tan

Increas ing

Di

Figure 4. Set cutoff distance approximately midway between the farthest target and the closest background

To maximize contrast, position the lightest possible background to be used, at the closest position it will come to the sensor during use (Figure 4). Using a small screwdriver in the adjustment screw, adjust the cutoff distance until the threshold is reached and the green Light Sensed indicator changes state. (If the indicator never comes ON, the background is beyond the maximum sensing cutoff and will be ignored.) Note the position of the rotating cutoff position indicator at this position. Then repeat the procedure, using the darkest target, placed in its most distant position for sensing. Adjust the cutoff so that the indicator is midway between the two positions (Figure 5).

Farthest Target Object

RANGE

Set Cutoff Midway Between

ON

Closest Background

DELAY DO

Figure 5. Setting the cutoff distance

Sensing Field

Strong Direct Reflection to R1

R1 R2 E

Cutoff Distance

Core of Emitted Beam Reflective Background

E = Emitter R1 = Near Detector R2 = Far Detector

Figure 6. Reflective background – problem

Sensing Field

Sensing Reliability For highest sensitivity, the sensor-to-object distance should be such that the object will be sensed at or near the point of maximum excess gain. The excess gain curves on page 1 show excess gain vs. sensing distance for 200 mm and 1 m cutoffs. Maximum excess gain for a 200 mm cutoff occurs at a lens-to-object distance of about 150 mm, and for a 1 m cutoff, at about 400 mm. The background must be placed beyond the cutoff distance. Following these two guidelines makes it possible to detect objects of low reflectivity, even against close-in reflective backgrounds. Background Reflectivity and Placement Avoid mirror-like backgrounds that produce specular reflections. False sensor response will occur if a background surface reflects the sensor’s light more strongly to the near detector (R1) than to the far detector (R2). The result is a false ON condition (Figure 6). Use of a diffusely-reflective (matte) background will cure this problem. Other possible solutions are to angle either the sensor or the background (in any plane) so that the background does not reflect back to the sensor (see Figure 7). An object beyond the cutoff distance, either moving or stationary (and when positioned as shown in Figure 8), can cause unwanted triggering of the sensor because it reflects more light to the near detector than to the far detector. The problem is easily remedied by rotating the sensor 90° (Figure 9) to align the sensing axis horizontally. The object then reflects the R1 and R2 fields equally, resulting in no false triggering.

Cutoff Distance

Cutoff Distance RANGE

E, R1, R2 ON

DELAY

DELAY

E

OFF

R1 R2

LO

R1 R2

DO

SIG

Reflective Background

E Core of Emitted Beam

E = Emitter R1 = Near Detector R2 = Far Detector

Strong Direct Reflection Away From Sensor

Figure 7. Reflective background – solution

Sensing Field

Figure 8. Object beyond cutoff distance, problem

Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164

Sensing Field

Figure 9. Object beyond cutoff distance, solution page 3

Page 4

Q60V Series Adjustable-Field Sensors – Visible Red Emitter Color Sensitivity The effects of object reflectivity on cutoff distance, though small, may be important for some applications.

It is expected that at any given cutoff setting, the actual cutoff distance for lower reflectance targets will be slightly shorter than for higher reflectance targets (see Figure 10). This behavior is known as color sensitivity. The percentage of deviation indicates a change in the cutoff point for either 18% gray or 6% black targets, relative to the cutoff point set for a 90% reflective white test card. For example, the cutoff point decreases 4% for a 6% reflectance black target when the cutoff point is adjusted for 1000 mm (40") using a 90% reflectance white test card. In other words, the cutoff point for the black target is 960 mm (38") for this setting. Setting the Output Delay The output of the Q60AFV sensor may be delayed between 0.008 and 16 seconds, in any of 72 increments. Delay is indicated on the 5-segment light bar using single LED segments or combinations of them, in varying stages of intensity. Major increments, displayed by a single full-intensity LED, are shown in Figure 13.

Percent Deviation

-1 -2 -3 18% Gray Card 6% Black Card

-4 -5 200

300

400

500

600

700

800

900

1000

Cutoff Setting (90% White Card)

Figure 10. Q60V Cutoff point deviation

Minimum Range with a 6% Black Card (mm)

The excess gain curves on page 1 were generated using a white test card of 90% reflectance. Objects with reflectivity of less than 90% reflect less light back to the sensor, and thus require proportionately more excess gain in order to be sensed with the same reliability as more reflective objects. When sensing an object of very low reflectivity, it may be especially important to sense it at or near the distance of maximum excess gain.

0

150 140 130 120 110 100 90 80 70 60 50 200

400

600

800

1000

Cutoff Distance (mm) with 90% White Card

Figure 11. Q60V minimum range vs. cutoff setting

DO

Hysteresis (% of Cutoff) with 6% Black Card

DO

2.0 1.5 1.0 0.5 0 200

400

600

800

1000

Cutoff Setting (mm) with 90% White Card

DO DO

LO

16 seconds

LO

72

SIG

4.0 seconds

SIG

56

LO

1.00 second

LO

40

SIG

0.250 second

SIG

24

DO

0.062 second

DO

8

LO

No Delay

LO

0

LED Status

SIG

Delay Time SIG

Step #

Figure 12. Q60V hysteresis

Figure 13. ON/OFF Delay options page 4

Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164

Page 5

Q60V Series Adjustable-Field Sensors – Visible Red Emitter To set a delay, single-click the appropriate button or pulse the remote wire as shown in Figure 14 to enable the process. Then use the + or – button or the appropriate remote wire pulse procedure to increase or decrease the delay (single-click adjusts the delay by one step at a time, and holding the button in provides a rapid increase/decrease). NOTE: Remote wire available on models Q60BB6AFV(Q1) only. T = 40 – 800 ms Press and Hold > 800 ms unless otherwise noted

Single-Click

Single-Click

Press and Hold

+

ON

DELAY

Step Increment

–

DELAY

OFF

+

ON

DELAY

Enter ON Delay Setup

–

DELAY

OFF

+

ON

DELAY

–

DELAY

OFF

Remote Push Button

Increase ON Delay – 4-second time-out

Rapid Increment

T >800 ms

T >800 ms

T >800 ms

Enter ON Delay Setup

Enable Delay Increment

Step Increment

>800 ms Rapid Increment

Single-Click

Single-Click

Press and Hold

+

ON

DELAY

Step Decrement

–

DELAY

OFF

ON

DELAY

+

DELAY

Enter ON Delay Setup

–

OFF

ON

+

DELAY

–

DELAY

OFF

Remote Push Button

Decrease ON Delay – 4-second time-out

Rapid Decrement

T >800 ms

T T T >800 ms

T >800 ms

Enter ON Delay Setup

Enable Delay Decrement

Step Decrement

>800 ms Rapid Decrement

Single-Click

Single-Click

+

ON

DELAY, DELAY

OFF

+

ON

Step Increment

Rapid Increment

T >800 ms

T >800 ms

Enable Delay Increment

Step Increment

T T T >800 ms Enter OFF Delay Setup

Press and Hold

DELAY

Enter OFF Delay Setup, DELAY

OFF

ON

+

DELAY, DELAY

OFF

Remote Push Button

Increase OFF Delay – 4-second time-out

>800 ms Rapid Increment

Single-Click

Single-Click

+

ON

DELAY, DELAY

Step Decrement

OFF

ON

DELAY, Enter OFF Delay Setup

Press and Hold

+

T T T >800 ms

DELAY

Enter OFF Delay Setup

OFF

+

ON

DELAY, DELAY

OFF

Remote Push Button

Decrease OFF Delay – 4-second time-out

Rapid Decrement

T T T >800 ms

T >800 ms

Enable Delay Decrement

Step Decrement

>800 ms Rapid Decrement

Figure 14. ON/OFF Delay configuration procedure

Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 page 5

Page 6

Q60V Series Adjustable-Field Sensors – Visible Red Emitter Light/Dark Operate Select Light Operate or Dark Operate mode may be selected using the two push buttons or a 4-second pulse of the remote line to toggle between the selections. See Figure 15. Push Button Lockout For security, the push buttons may be locked out using either the remote line or the push buttons themselves. See Figure 16.

Remote Push Button

Push Button Lock-out Toggle

Four-Second Press and Hold

+

ON

DELAY

–

Figure 15. Light/Dark operate toggle options

DELAY

>4 sec.

Concurrent Quad-Click OFF

+

ON

DELAY

–

DELAY

OFF

Remote Push Button

LO/DO Toggle

T T T T T T T >800 ms

Figure 16. Lockout toggle

Q60V Adjustable-Field Sensor Dimensions

15.2 mm (0.60")

4.0 mm (0.16") 4.9 mm 4.0 mm (0.19") (0.16")

–

DELAY

OFF

LO

SIG

+

ON

DELAY

DO

25.0 mm (0.98")

RANGE

60.0 mm (2.36")

52.0 mm (2.05") 2x ø4.2 mm

(0.17")

14.0 mm (0.55") Q60BB6AF200

52.0 mm (2.05")

75.0 mm (2.95")

bn

67.0 mm (2.64")

bu wh bk

Q60BB6AF200Q bn

+ 10-30V dc – wh Load bk

Load

Load gy gy

Remote Teach

M3 hardware is included

+ 10-30V dc – bu

Load

Remote Teach

17.0 mm (0.67") 77.6 mm (3.06")

Q60V Specifications Supply Voltage and Current

Q60BB6AFV models: 10 to 30V dc (10% maximum ripple) at less than 50 mA exclusive of load Q60VR3AFV Universal models: 12 to 250V dc or 24 to 250V ac, 50/60 Hz

Supply Protection Circuitry

Protected against reverse polarity and transient voltages (Q60VR3 models’ dc hookup is without regard to polarity)

Output Configuration

Q60BB6AFV models: Bipolar; one NPN (current sinking) and one PNP (current sourcing) open-collector transistor Q60VR3AFV cabled model: E/M Relay (SPDT), normally closed and normally open contacts Q60VR3AFVQ1 (QD) model: E/M Relay (SPST), normally open contact page 6

Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164

Page 7

Q60V Series Adjustable-Field Sensors – Visible Red Emitter Q60V Specifications Output Rating

Q60BB6AFV models 150 mA maximum each output @ 25° C Off-state leakage current: < 5µA @ 30V dc Output saturation NPN: < 200 mV @ 10 mA and < 1V @150mA Output saturation PNP: < 1V at 10 mA; < 1.5V at 150 mA Q60VR3AFV Universal models Min. voltage and current: 5V dc, 10 mA Mechanical life of relay: 50,000,000 operations Electrical life of relay at full resistive load: 100,000 operations Max. switching power (resistive load): Cabled models: 1250VA, 150 W QD models: 750VA, 90W Max. switching voltage (resistive load): Cabled models: 250V ac, 125V dc QD models: 250V ac, 125V dc Max. switching current (resistive load): Cabled models: 5 A @ 250V ac, 5 A @ 30V dc derated to 200 mA @ 125V dc QD models: 3 A @ 250V ac, 3 A @ 30V dc derated to 200 mA @ 125V dc

Output Protection Circuitry

Q60BB6AFV models: Protected against continuous overload or short circuit of outputs All models: Protected against false pulse on power-up

Output Response Time

Q60BB6AFV models: 2 milliseconds ON and OFF NOTE: 150 millisecond delay on power-up; outputs do not conduct during this time. Q60VR3AFV Universal models: 15 milliseconds ON and OFF NOTE: 150 millisecond delay on power-up; relay is de-energized during this time.

Repeatability

500 microseconds

Sensing Hysteresis

See Figure 12.

Indicators

ON Delay

NOTE: Outputs are active during on/off timing selection mode.

OFF Delay

Adjustments

2 momentary push buttons: ON Delay (+) and OFF Delay (–) (DC models also have remote program wire) ON Delay select: 8 ms to 16 seconds OFF Delay select: 8 ms to 16 seconds LO/DO select Push button lockout for security Slotted, geared, 2-turn, cutoff range adjustment screw (mechanical stops on both ends of travel)

Construction

Housing: ABS polycarbonate blend Lens: Acrylic Cover: Clear ABS

Environmental Rating

IEC IP67; NEMA 6

Connections

2 m (6.5') or 9 m (30') attached cable, 5-pin Euro-style fitting, or 5-pin Mini-style 150 mm (6") QD pigtail, depending on model. QD cables are ordered separately; see page 8.

Operating Conditions

Temperature: -20° to +55°C (-7° to +131°F) Maximum Relative Humidity: 90% at 50°C (non-condensing)

Steady Green: Run mode, ON delay is active Flashing Green: ON Delay Selection mode is active Steady Green: Run mode, OFF delay is active Flashing Green: OFF Delay Selection mode is active

5-Segment Light Bar*: Indicates relative delay time during ON or OFF Delay Selection modes Output Steady Amber: Outputs are conducting Steady Green: During ON/OFF Delay Selection modes Dark Operate Steady Green: Dark Operate is selected Lockout Steady Green: Buttons are locked out Light Operate Steady Green: Light Operate is selected Signal Steady Green: Sensor is receiving signal Flashing Green: Marginal signal (1.0 to 2.25 excess gain) *Output, Dark Operate, Lockout, Light Operate and Signal indicators function as 5-Segment Light Bar during ON or OFF Delay Selection modes

Certifications Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 page 7

Page 8

Q60V Series Adjustable-Field Sensors – Visible Red Emitter Q60V Adjustable-Field Hookups 5-Pin Euro-Style Pin-out

Q60BB6AFV1000(Q) (Cabled and QD Models) 10 to 30V dc bn wh bk

(Cable Connector Shown)

+ 10-30V dc – bu

Q60VR3AFV1000

White Wire

Q60VR3AFV1000Q1 4-Pin Micro-Style Pin-out (QD Model) 24 to 250V ac (50/60Hz) (Cable Connector Shown) or 12 to 250V dc bn

Brown Wire rd/wh

Blue Wire wh

Gray Wire

NC ye

Load gy rd

C bk

Remote Program*

Green Wire rd/bk AC/DC bu

Black Wire

Load

(Cabled Model) 24 to 250V ac (50/60Hz) or 12 to 250V dc gn

NO

5A max. load

AC/DC

Red Wire

NO

Red/White Wire

Red/Black Wire

C

3A max. load

*DC models only; LO/DO and output delay select

Quick-Disconnect (QD) Cables Style

Model

Length

Connector

5-Pin Euro

MQDC1-506 MQDC1-515 MQDC1-530 MQDC1-506RA MQDC1-515RA MQDC1-530RA

2 m (6.5') 5 m (15') 9 m (30') 2 m (6.5') 5 m (15') 9 m (30')

Straight Straight Straight Right-angle Right-angle Right-angle

SMBQ60

8.0 mm (0.31") 4.0 mm (0.16")

11.0 mm (0.43") 20.0 mm (0.79")

1.9 mm (0.75")

58.0 mm (2.28") R84.8 mm (3.34")

15.0 mm (0.59")

8.0 mm (0.31")

19.0 mm (0.75") 3°

4.0 mm (0.16")

6° 37.8°

10.0 mm (0.39")

4.2 mm (0.17")

ø4.5 mm (0.18")

R24.1 mm (0.95") 10.0° 5.0°

2x R2.25 (0.88") 32.0 mm (1.26")

Model

Length

Connector

4-Pin Micro

MQAC-406 MQAC-415 MQAC-430 MQAC-406RA MQAC-415RA MQAC-430RA

2 m (6.5') 5 m (15') 9 m (30') 2 m (6.5') 5 m (15') 9 m (30')

Straight Straight Straight Right-angle Right-angle Right-angle

Banner Engineering Corp Limited Warranty

• Right-angle bracket • 14-ga., 304 Stainless Steel

4.0 mm (0.16") ø3.8 mm (0.15")

Style

82.0 mm (3.23")

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period.This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OFALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.

64.0 mm (2.52")

Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.com