The text of a spec sheet · part 1 of 1
Q60AFV Series Sensors with Visible Red Emitter: Self-Contained Adjustable-Field Sensors, pages 1 to 8
Pages 1 to 8 of 8
The original document is the PDF (692 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Banner Q60BB6AFV1000Q
Page 1
Q60AFV Series Sensors with Visible Red Emitter Self-Contained Adjustable-Field Sensors
Q60AFV Adjustable-Field Features • Adjustable-field background suppression sensor detects objects within a defined sensing field, while ignoring objects located beyond the sensing field cutoff • Two-turn, logarithmic adjustment of sensing field cutoff point from 0.2 to 1 m; allows easy setting of cutoff point at long range • Rotating pointer indicates relative cutoff point setting • Easy push-button or remote programming of light/dark operate and output timing; continuous status indicators verify all settings at a glance • Output ON and/or OFF delays adjustable from 8 milliseconds to 16 seconds • Powerful, highly collimated visible red sensing beam • Tough ABS/polycarbonate blend housing is rated IEC IP67; NEMA 6 10-30V dc Models (Q60BB6AFV): • Powered by 10 to 30V dc; bipolar (one NPN and one PNP) outputs • Available with integral cable or rotating Euro-style quick-disconnect fitting Universal Voltage Models (Q60VR3AFV): • 12-250V dc or 24-250V ac, 50/60 Hz • Available with integral cable or rotating Micro-style quick-disconnect fitting Visible Red, 665 nm
Q60 Adjustable-Field Models Minimum Range
Models
Cutoff Point
Cable*
Q60BB6AFV1000
5-wire 2 m (6.5')
Q60BB6AFV1000Q
5-pin Euro-style QD
Q60VR3AFV1000
Q60VR3AFV1000Q1
65 mm to 130 mm Adjustable: (2.5" to 5") 200 mm to 5-wire depending 1000 mm 2 m (6.5') on cutoff (8" to 40") point setting
4-pin Micro-style QD
Supply Voltage
Output Type
10-30V dc
Bipolar NPN/PNP
Excess Gain at 200 mm Cutoff
Excess Gain at 1000 mm Cutoff
10000
10000
1000
1000
Q60AFV
Universal Voltage 12-250V dc or 24-250V ac
E/M Relay (SPDT), normally closed and normally open contacts E/M Relay (SPST), normally open contact
E X C E S S G A I N
Q60AFV
E X C E S S
100
10
1 1 mm 0.04 in
G A I N 10 mm 0.4 in
100 mm 4 in
DISTANCE
1000 40 in
100
10
1 1 mm 0.04 in
10 mm 0.4 in
100 mm 4 in
1000 mm 40 in
DISTANCE
* 9 meter cables are available by adding suffix “W/30” to the model number of any cabled sensor (e.g., Q60BB6AFV1000 W/30). A model with a QD connector requires a mating cable; see page 8.
!
WARNING . . . Not To Be Used for Personnel Protection Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.
Printed in USA
02/12
P/N 69622 rev. B
Page 2
Q60V Series Adjustable-Field Sensors – Visible Red Emitter Q60AFV Overview The Q60AFV sensor is a full-featured adjustable-field sensor. These adjustable-field sensors are able to detect objects of relatively low reflectivity, while ignoring other objects in the background (beyond the cutoff point). The cutoff distance is mechanically adjustable, using the 2-turn adjustment screw on the sensor top (Figure 1). A rotating pointer indicates the relative cutoff position. (The indicator moves clockwise to show increasing distance.)
ON/OFF Delay Push Buttons and Indicators
Indicators Below Also Function as a 5-Segment Light Bar During Delay Selection Modes
Cutoff Adjustment Screw
Light Sensed Indicator Light Operate Selected Push Button Lockout Indicator
Two push buttons (ON Delay and OFF Delay) are used to set the output delay options, to toggle between light and dark operate modes and to lock out the push buttons for security purposes. These functions also may be accomplished using the remote wire. Seven LED indicators show, during RUN mode, the sensor configuration and operating status. During Delay Configuration, 5 of the LEDs combine to form a single light bar that indicates relative ON or OFF delay time. Adjustable-Field Sensing, Theory of Operation In operation, the Q60AFV compares the reflections of its emitted light beam (E) from an object back to the sensor’s two differently-aimed detectors R1 and R2 (see Figure 2). If the near detector (R1) light signal is stronger than the far detector (R2) light signal (see object A, closer than the cutoff distance), the sensor responds to the object. If the far detector (R2) light signal is stronger than the near detector (R1) light signal (see object B, object beyond the cutoff distance), the sensor ignores the object.
Dark Operate Selected Output Conducting (Bi-color Amber/Green)
Figure 1. Q60V features Cutoff Distance Receiver Elements Near R1 Detector
Lenses
Far R2 Detector
The cutoff distance for Q60AFV sensors is adjustable from 200 to 1000 millimeters (8" to 40"). Objects lying beyond the cutoff distance are ignored, even if they are highly reflective. However, it is possible to falsely detect a background object, under certain conditions (see Background Reflectivity and Placement, page 3). In the drawings and discussion on this page and page 3, the letters E, R1, and R2 identify how the sensor’s three optical elements (Emitter “E”, Near Detector “R1”, and Far Detector “R2”) line up across the face of the sensor. The location of these elements defines the sensing axis (see Figure 3). The sensing axis becomes important in certain situations, such as those illustrated in Figures 8 and 9.
Object B or Background
Object A
E
Sensing Range
Figure 2. Adjustable field sensing concept
Receiver Elements Emitter
When an object approaches from the side, the most reliable sensing usually occurs when the line of approach is parallel to the sensing axis.
Sensing Axis
Figure 3. Q60V sensing axis page 2
Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164
Page 3
Q60V Series Adjustable-Field Sensors – Visible Red Emitter Sensor Setup Target
Background
Setting the Cutoff Distance The cutoff distance for Q60AFV sensors may be adjusted between 200 mm and 1000 mm (8" to 40").
R1 R2 E
Cutoff Distance s
NOTE: Setting the cutoff distance adjustment screw to its maximum clockwise position places the receiver lens directly in front of the receiver elements and results in the Q60 performing as a long-range diffuse sensor.
ce tan
Increas ing
Di
Figure 4. Set cutoff distance approximately midway between the farthest target and the closest background
To maximize contrast, position the lightest possible background to be used, at the closest position it will come to the sensor during use (Figure 4). Using a small screwdriver in the adjustment screw, adjust the cutoff distance until the threshold is reached and the green Light Sensed indicator changes state. (If the indicator never comes ON, the background is beyond the maximum sensing cutoff and will be ignored.) Note the position of the rotating cutoff position indicator at this position. Then repeat the procedure, using the darkest target, placed in its most distant position for sensing. Adjust the cutoff so that the indicator is midway between the two positions (Figure 5).
Farthest Target Object
RANGE
Set Cutoff Midway Between
ON
Closest Background
DELAY DO
Figure 5. Setting the cutoff distance
Sensing Field
Strong Direct Reflection to R1
R1 R2 E
Cutoff Distance
Core of Emitted Beam Reflective Background
E = Emitter R1 = Near Detector R2 = Far Detector
Figure 6. Reflective background – problem
Sensing Field
Sensing Reliability For highest sensitivity, the sensor-to-object distance should be such that the object will be sensed at or near the point of maximum excess gain. The excess gain curves on page 1 show excess gain vs. sensing distance for 200 mm and 1 m cutoffs. Maximum excess gain for a 200 mm cutoff occurs at a lens-to-object distance of about 150 mm, and for a 1 m cutoff, at about 400 mm. The background must be placed beyond the cutoff distance. Following these two guidelines makes it possible to detect objects of low reflectivity, even against close-in reflective backgrounds. Background Reflectivity and Placement Avoid mirror-like backgrounds that produce specular reflections. False sensor response will occur if a background surface reflects the sensor’s light more strongly to the near detector (R1) than to the far detector (R2). The result is a false ON condition (Figure 6). Use of a diffusely-reflective (matte) background will cure this problem. Other possible solutions are to angle either the sensor or the background (in any plane) so that the background does not reflect back to the sensor (see Figure 7). An object beyond the cutoff distance, either moving or stationary (and when positioned as shown in Figure 8), can cause unwanted triggering of the sensor because it reflects more light to the near detector than to the far detector. The problem is easily remedied by rotating the sensor 90° (Figure 9) to align the sensing axis horizontally. The object then reflects the R1 and R2 fields equally, resulting in no false triggering.
Cutoff Distance
Cutoff Distance RANGE
E, R1, R2 ON
DELAY
DELAY
E
OFF
R1 R2
LO
R1 R2
DO
SIG
Reflective Background
E Core of Emitted Beam
E = Emitter R1 = Near Detector R2 = Far Detector
Strong Direct Reflection Away From Sensor
Figure 7. Reflective background – solution
Sensing Field
Figure 8. Object beyond cutoff distance, problem
Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164
Sensing Field
Figure 9. Object beyond cutoff distance, solution page 3
Page 4
Q60V Series Adjustable-Field Sensors – Visible Red Emitter Color Sensitivity The effects of object reflectivity on cutoff distance, though small, may be important for some applications.
It is expected that at any given cutoff setting, the actual cutoff distance for lower reflectance targets will be slightly shorter than for higher reflectance targets (see Figure 10). This behavior is known as color sensitivity. The percentage of deviation indicates a change in the cutoff point for either 18% gray or 6% black targets, relative to the cutoff point set for a 90% reflective white test card. For example, the cutoff point decreases 4% for a 6% reflectance black target when the cutoff point is adjusted for 1000 mm (40") using a 90% reflectance white test card. In other words, the cutoff point for the black target is 960 mm (38") for this setting. Setting the Output Delay The output of the Q60AFV sensor may be delayed between 0.008 and 16 seconds, in any of 72 increments. Delay is indicated on the 5-segment light bar using single LED segments or combinations of them, in varying stages of intensity. Major increments, displayed by a single full-intensity LED, are shown in Figure 13.
Percent Deviation
-1 -2 -3 18% Gray Card 6% Black Card
-4 -5 200
300
400
500
600
700
800
900
1000
Cutoff Setting (90% White Card)
Figure 10. Q60V Cutoff point deviation
Minimum Range with a 6% Black Card (mm)
The excess gain curves on page 1 were generated using a white test card of 90% reflectance. Objects with reflectivity of less than 90% reflect less light back to the sensor, and thus require proportionately more excess gain in order to be sensed with the same reliability as more reflective objects. When sensing an object of very low reflectivity, it may be especially important to sense it at or near the distance of maximum excess gain.
0
150 140 130 120 110 100 90 80 70 60 50 200
400
600
800
1000
Cutoff Distance (mm) with 90% White Card
Figure 11. Q60V minimum range vs. cutoff setting
DO
Hysteresis (% of Cutoff) with 6% Black Card
DO
2.0 1.5 1.0 0.5 0 200
400
600
800
1000
Cutoff Setting (mm) with 90% White Card
DO DO
LO
16 seconds
LO
72
SIG
4.0 seconds
SIG
56
LO
1.00 second
LO
40
SIG
0.250 second
SIG
24
DO
0.062 second
DO
8
LO
No Delay
LO
0
LED Status
SIG
Delay Time SIG
Step #
Figure 12. Q60V hysteresis
Figure 13. ON/OFF Delay options page 4
Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164
Page 5
Q60V Series Adjustable-Field Sensors – Visible Red Emitter To set a delay, single-click the appropriate button or pulse the remote wire as shown in Figure 14 to enable the process. Then use the + or – button or the appropriate remote wire pulse procedure to increase or decrease the delay (single-click adjusts the delay by one step at a time, and holding the button in provides a rapid increase/decrease). NOTE: Remote wire available on models Q60BB6AFV(Q1) only. T = 40 – 800 ms Press and Hold > 800 ms unless otherwise noted
Single-Click
Single-Click
Press and Hold
+
ON
DELAY
Step Increment
–
DELAY
OFF
+
ON
DELAY
Enter ON Delay Setup
–
DELAY
OFF
+
ON
DELAY
–
DELAY
OFF
Remote Push Button
Increase ON Delay – 4-second time-out
Rapid Increment
T >800 ms
T >800 ms
T >800 ms
Enter ON Delay Setup
Enable Delay Increment
Step Increment
>800 ms Rapid Increment
Single-Click
Single-Click
Press and Hold
+
ON
DELAY
Step Decrement
–
DELAY
OFF
ON
DELAY
+
DELAY
Enter ON Delay Setup
–
OFF
ON
+
DELAY
–
DELAY
OFF
Remote Push Button
Decrease ON Delay – 4-second time-out
Rapid Decrement
T >800 ms
T T T >800 ms
T >800 ms
Enter ON Delay Setup
Enable Delay Decrement
Step Decrement
>800 ms Rapid Decrement
Single-Click
Single-Click
+
ON
DELAY, DELAY
OFF
+
ON
Step Increment
Rapid Increment
T >800 ms
T >800 ms
Enable Delay Increment
Step Increment
T T T >800 ms Enter OFF Delay Setup
Press and Hold
DELAY
Enter OFF Delay Setup, DELAY
OFF
ON
+
DELAY, DELAY
OFF
Remote Push Button
Increase OFF Delay – 4-second time-out
>800 ms Rapid Increment
Single-Click
Single-Click
+
ON
DELAY, DELAY
Step Decrement
OFF
ON
DELAY, Enter OFF Delay Setup
Press and Hold
+
T T T >800 ms
DELAY
Enter OFF Delay Setup
OFF
+
ON
DELAY, DELAY
OFF
Remote Push Button
Decrease OFF Delay – 4-second time-out
Rapid Decrement
T T T >800 ms
T >800 ms
Enable Delay Decrement
Step Decrement
>800 ms Rapid Decrement
Figure 14. ON/OFF Delay configuration procedure
Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 page 5
Page 6
Q60V Series Adjustable-Field Sensors – Visible Red Emitter Light/Dark Operate Select Light Operate or Dark Operate mode may be selected using the two push buttons or a 4-second pulse of the remote line to toggle between the selections. See Figure 15. Push Button Lockout For security, the push buttons may be locked out using either the remote line or the push buttons themselves. See Figure 16.
Remote Push Button
Push Button Lock-out Toggle
Four-Second Press and Hold
+
ON
DELAY
–
Figure 15. Light/Dark operate toggle options
DELAY
>4 sec.
Concurrent Quad-Click OFF
+
ON
DELAY
–
DELAY
OFF
Remote Push Button
LO/DO Toggle
T T T T T T T >800 ms
Figure 16. Lockout toggle
Q60V Adjustable-Field Sensor Dimensions
15.2 mm (0.60")
4.0 mm (0.16") 4.9 mm 4.0 mm (0.19") (0.16")
–
DELAY
OFF
LO
SIG
+
ON
DELAY
DO
25.0 mm (0.98")
RANGE
60.0 mm (2.36")
52.0 mm (2.05") 2x ø4.2 mm
(0.17")
14.0 mm (0.55") Q60BB6AF200
52.0 mm (2.05")
75.0 mm (2.95")
bn
67.0 mm (2.64")
bu wh bk
Q60BB6AF200Q bn
+ 10-30V dc – wh Load bk
Load
Load gy gy
Remote Teach
M3 hardware is included
+ 10-30V dc – bu
Load
Remote Teach
17.0 mm (0.67") 77.6 mm (3.06")
Q60V Specifications Supply Voltage and Current
Q60BB6AFV models: 10 to 30V dc (10% maximum ripple) at less than 50 mA exclusive of load Q60VR3AFV Universal models: 12 to 250V dc or 24 to 250V ac, 50/60 Hz
Supply Protection Circuitry
Protected against reverse polarity and transient voltages (Q60VR3 models’ dc hookup is without regard to polarity)
Output Configuration
Q60BB6AFV models: Bipolar; one NPN (current sinking) and one PNP (current sourcing) open-collector transistor Q60VR3AFV cabled model: E/M Relay (SPDT), normally closed and normally open contacts Q60VR3AFVQ1 (QD) model: E/M Relay (SPST), normally open contact page 6
Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164
Page 7
Q60V Series Adjustable-Field Sensors – Visible Red Emitter Q60V Specifications Output Rating
Q60BB6AFV models 150 mA maximum each output @ 25° C Off-state leakage current: < 5µA @ 30V dc Output saturation NPN: < 200 mV @ 10 mA and < 1V @150mA Output saturation PNP: < 1V at 10 mA; < 1.5V at 150 mA Q60VR3AFV Universal models Min. voltage and current: 5V dc, 10 mA Mechanical life of relay: 50,000,000 operations Electrical life of relay at full resistive load: 100,000 operations Max. switching power (resistive load): Cabled models: 1250VA, 150 W QD models: 750VA, 90W Max. switching voltage (resistive load): Cabled models: 250V ac, 125V dc QD models: 250V ac, 125V dc Max. switching current (resistive load): Cabled models: 5 A @ 250V ac, 5 A @ 30V dc derated to 200 mA @ 125V dc QD models: 3 A @ 250V ac, 3 A @ 30V dc derated to 200 mA @ 125V dc
Output Protection Circuitry
Q60BB6AFV models: Protected against continuous overload or short circuit of outputs All models: Protected against false pulse on power-up
Output Response Time
Q60BB6AFV models: 2 milliseconds ON and OFF NOTE: 150 millisecond delay on power-up; outputs do not conduct during this time. Q60VR3AFV Universal models: 15 milliseconds ON and OFF NOTE: 150 millisecond delay on power-up; relay is de-energized during this time.
Repeatability
500 microseconds
Sensing Hysteresis
See Figure 12.
Indicators
ON Delay
NOTE: Outputs are active during on/off timing selection mode.
OFF Delay
Adjustments
2 momentary push buttons: ON Delay (+) and OFF Delay (–) (DC models also have remote program wire) ON Delay select: 8 ms to 16 seconds OFF Delay select: 8 ms to 16 seconds LO/DO select Push button lockout for security Slotted, geared, 2-turn, cutoff range adjustment screw (mechanical stops on both ends of travel)
Construction
Housing: ABS polycarbonate blend Lens: Acrylic Cover: Clear ABS
Environmental Rating
IEC IP67; NEMA 6
Connections
2 m (6.5') or 9 m (30') attached cable, 5-pin Euro-style fitting, or 5-pin Mini-style 150 mm (6") QD pigtail, depending on model. QD cables are ordered separately; see page 8.
Operating Conditions
Temperature: -20° to +55°C (-7° to +131°F) Maximum Relative Humidity: 90% at 50°C (non-condensing)
Steady Green: Run mode, ON delay is active Flashing Green: ON Delay Selection mode is active Steady Green: Run mode, OFF delay is active Flashing Green: OFF Delay Selection mode is active
5-Segment Light Bar*: Indicates relative delay time during ON or OFF Delay Selection modes Output Steady Amber: Outputs are conducting Steady Green: During ON/OFF Delay Selection modes Dark Operate Steady Green: Dark Operate is selected Lockout Steady Green: Buttons are locked out Light Operate Steady Green: Light Operate is selected Signal Steady Green: Sensor is receiving signal Flashing Green: Marginal signal (1.0 to 2.25 excess gain) *Output, Dark Operate, Lockout, Light Operate and Signal indicators function as 5-Segment Light Bar during ON or OFF Delay Selection modes
Certifications Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 page 7
Page 8
Q60V Series Adjustable-Field Sensors – Visible Red Emitter Q60V Adjustable-Field Hookups 5-Pin Euro-Style Pin-out
Q60BB6AFV1000(Q) (Cabled and QD Models) 10 to 30V dc bn wh bk
(Cable Connector Shown)
+ 10-30V dc – bu
Q60VR3AFV1000
White Wire
Q60VR3AFV1000Q1 4-Pin Micro-Style Pin-out (QD Model) 24 to 250V ac (50/60Hz) (Cable Connector Shown) or 12 to 250V dc bn
Brown Wire rd/wh
Blue Wire wh
Gray Wire
NC ye
Load gy rd
C bk
Remote Program*
Green Wire rd/bk AC/DC bu
Black Wire
Load
(Cabled Model) 24 to 250V ac (50/60Hz) or 12 to 250V dc gn
NO
5A max. load
AC/DC
Red Wire
NO
Red/White Wire
Red/Black Wire
C
3A max. load
*DC models only; LO/DO and output delay select
Quick-Disconnect (QD) Cables Style
Model
Length
Connector
5-Pin Euro
MQDC1-506 MQDC1-515 MQDC1-530 MQDC1-506RA MQDC1-515RA MQDC1-530RA
2 m (6.5') 5 m (15') 9 m (30') 2 m (6.5') 5 m (15') 9 m (30')
Straight Straight Straight Right-angle Right-angle Right-angle
SMBQ60
8.0 mm (0.31") 4.0 mm (0.16")
11.0 mm (0.43") 20.0 mm (0.79")
1.9 mm (0.75")
58.0 mm (2.28") R84.8 mm (3.34")
15.0 mm (0.59")
8.0 mm (0.31")
19.0 mm (0.75") 3°
4.0 mm (0.16")
6° 37.8°
10.0 mm (0.39")
4.2 mm (0.17")
ø4.5 mm (0.18")
R24.1 mm (0.95") 10.0° 5.0°
2x R2.25 (0.88") 32.0 mm (1.26")
Model
Length
Connector
4-Pin Micro
MQAC-406 MQAC-415 MQAC-430 MQAC-406RA MQAC-415RA MQAC-430RA
2 m (6.5') 5 m (15') 9 m (30') 2 m (6.5') 5 m (15') 9 m (30')
Straight Straight Straight Right-angle Right-angle Right-angle
Banner Engineering Corp Limited Warranty
• Right-angle bracket • 14-ga., 304 Stainless Steel
4.0 mm (0.16") ø3.8 mm (0.15")
Style
82.0 mm (3.23")
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period.This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OFALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.
64.0 mm (2.52")
Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.com