The instruction and maintenance manual for the Conoflow FR95 Series Airpak filter-regulator, which supplies clean, regulated air to instruments, valves, positioners and other pneumatic devices. It gives materials and specifications, installation and dimensions, the 11-character model code (filter, bonnet, adjustment, diaphragm, gauge, bowl and control range options, which decode a number such as FR95XSKEX1F), operation, typical flow curves, a troubleshooting guide, and disassembly and reassembly steps.

Its parts

  1. General Product Overview
  2. Materials of Construction
  3. Specifications
  4. Regulator Cleaning
  5. Installation
  6. Control Engineering Data
  7. Operation in Service
  8. Troubleshooting Guide
  9. Repair and Maintenance
  10. Disassembly
  11. Assembly

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

Conoflow instruction and maintenance manual for the FR95 Series Airpak filter-regulator, which supplies clean, regulated air to pneumatic instruments and control devices. Its parts list covers the FR95XSKEX1C, FR95XSKEX1D, FR95XSKEX1F and FR95XSKEX1G range versions. It explains the specifications, the 11-digit model code, installation, operation, troubleshooting, disassembly and reassembly.

Device
FR95 Series Airpak filter-regulator that supplies clean, accurate air to instruments, valves, positioners and transducers p. 1
Model code
FR95XSKEX1F: polypropylene 35 micron filter, plain bonnet, wrench-style knob, Buna N relieving no-bleed diaphragm, no gauge, standard bowl, 60 psig range p. 3, 6
Output range
F range: 0-60 psig (0-414 kPa); other ranges 25, 35 and 125 psig p. 1, 3
Max supply pressure
250 psig (1724 kPa) p. 1
Connections
1/4" NPT inlet and outlet; two 1/4" NPT gauge ports at 90 degrees from the outlet p. 1
Flow capacity
Cv = 0.5 p. 1
Temperature range
-40 °F to 165 °F (-40 °C to 74 °C) p. 1
Weight
1.6 lb p. 1
Materials
Black anodized aluminum body, bowl and bonnet; brass nozzle with Buna N soft seat; nylon-reinforced Buna N diaphragm p. 1
Proof and burst
Proof 150%, burst 400% of maximum operating pressure p. 1
Leakage
Under 20 sccm across the valve; supply effect 0.6 psig per 25 psig supply change p. 1
Spare parts kits
G6387043 for relieving diaphragm (items 8, 11, 12, 14); G6387044 for no bleed, no relief diaphragm p. 6
Mounting
Line mounted, or wall mounted with the optional bracket and 1/4" fasteners p. 2
Body screws
Six 10-24 X 2" machine screws, part G6900653 p. 5, 6

What this manual walks you through

  • Reading the 11-digit model code p. 3
  • Installing and first pressurizing the regulator p. 2
  • Adjusting output pressure and shutting the system down p. 3
  • Reading the typical air flow performance chart p. 4
  • Troubleshooting leaks, rising outlet pressure and noise p. 4
  • Disassembling the regulator p. 5
  • Reassembling and testing the plug spring position p. 5
  • Ordering spare parts from the parts list p. 6

Good to know

  • Not recommended for use with flammable liquids or gases. p. 1
  • Install with the draincock downward so collected fluid can drain. p. 2
  • Connecting the supply line to the OUT port can damage the regulator or cause unexpected flow. p. 2
  • Tighten the jam nut, or the handwheel or knob can vibrate loose and fall out. p. 2
  • Outlet pressure falls as flow rises, and rises 0.6 psi per 25 psi drop in inlet pressure. p. 3

Questions this manual answers

What does the model number FR95XSKEX1F mean?

An FR95 with a polypropylene 35 micron filter, plain bonnet, wrench-style knob, Buna N relieving diaphragm, no gauge, standard bowl and 60 psig range. p. 3, 6

How do I raise the output pressure on a Conoflow FR95?

Turn the knob or handwheel clockwise to increase the set pressure, and counterclockwise to decrease it. p. 3

Why does FR95 outlet pressure keep rising after flow stops?

The manual points to valve seat leakage; clean the parts and fit a new valve plug and filter element. p. 4

What is the maximum inlet pressure of the FR95?

250 psig (1724 kPa). p. 1

Which repair kit fits an FR95 with a relieving diaphragm?

Kit G6387043, which holds items 8, 11, 12 and 14. p. 6

The whole text · 1 part

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6

The file

Revision and size

RevisionFR95-IOM Rev. C 10/06
PublisherConoflow
Pages6
PDF228 KB
TextText from the PDF itself.

The first pages · 3 of 6

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 6
Page 2
Page 2of 6
Page 3
Page 3of 6