Manual · Conoflow
Instruction and Maintenance Manual: FR95 Pressure Regulator
Manual6 pagesPDF 228 KB
Instruction and maintenance manual for the Conoflow FR95 Airpak filter-regulator: specs, model code, installation, troubleshooting and repair.
Covers · 1 model
The models it covers
Summary
What is in it
The instruction and maintenance manual for the Conoflow FR95 Series Airpak filter-regulator, which supplies clean, regulated air to instruments, valves, positioners and other pneumatic devices. It gives materials and specifications, installation and dimensions, the 11-character model code (filter, bonnet, adjustment, diaphragm, gauge, bowl and control range options, which decode a number such as FR95XSKEX1F), operation, typical flow curves, a troubleshooting guide, and disassembly and reassembly steps.
Its parts
- General Product Overview
- Materials of Construction
- Specifications
- Regulator Cleaning
- Installation
- Control Engineering Data
- Operation in Service
- Troubleshooting Guide
- Repair and Maintenance
- Disassembly
- Assembly
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
Conoflow instruction and maintenance manual for the FR95 Series Airpak filter-regulator, which supplies clean, regulated air to pneumatic instruments and control devices. Its parts list covers the FR95XSKEX1C, FR95XSKEX1D, FR95XSKEX1F and FR95XSKEX1G range versions. It explains the specifications, the 11-digit model code, installation, operation, troubleshooting, disassembly and reassembly.
- Device
- FR95 Series Airpak filter-regulator that supplies clean, accurate air to instruments, valves, positioners and transducers p. 1
- Model code
- FR95XSKEX1F: polypropylene 35 micron filter, plain bonnet, wrench-style knob, Buna N relieving no-bleed diaphragm, no gauge, standard bowl, 60 psig range p. 3, 6
- Output range
- F range: 0-60 psig (0-414 kPa); other ranges 25, 35 and 125 psig p. 1, 3
- Max supply pressure
- 250 psig (1724 kPa) p. 1
- Connections
- 1/4" NPT inlet and outlet; two 1/4" NPT gauge ports at 90 degrees from the outlet p. 1
- Flow capacity
- Cv = 0.5 p. 1
- Temperature range
- -40 °F to 165 °F (-40 °C to 74 °C) p. 1
- Weight
- 1.6 lb p. 1
- Materials
- Black anodized aluminum body, bowl and bonnet; brass nozzle with Buna N soft seat; nylon-reinforced Buna N diaphragm p. 1
- Proof and burst
- Proof 150%, burst 400% of maximum operating pressure p. 1
- Leakage
- Under 20 sccm across the valve; supply effect 0.6 psig per 25 psig supply change p. 1
- Spare parts kits
- G6387043 for relieving diaphragm (items 8, 11, 12, 14); G6387044 for no bleed, no relief diaphragm p. 6
- Mounting
- Line mounted, or wall mounted with the optional bracket and 1/4" fasteners p. 2
- Body screws
- Six 10-24 X 2" machine screws, part G6900653 p. 5, 6
What this manual walks you through
- Reading the 11-digit model code p. 3
- Installing and first pressurizing the regulator p. 2
- Adjusting output pressure and shutting the system down p. 3
- Reading the typical air flow performance chart p. 4
- Troubleshooting leaks, rising outlet pressure and noise p. 4
- Disassembling the regulator p. 5
- Reassembling and testing the plug spring position p. 5
- Ordering spare parts from the parts list p. 6
Good to know
- Not recommended for use with flammable liquids or gases. p. 1
- Install with the draincock downward so collected fluid can drain. p. 2
- Connecting the supply line to the OUT port can damage the regulator or cause unexpected flow. p. 2
- Tighten the jam nut, or the handwheel or knob can vibrate loose and fall out. p. 2
- Outlet pressure falls as flow rises, and rises 0.6 psi per 25 psi drop in inlet pressure. p. 3
Questions this manual answers
What does the model number FR95XSKEX1F mean?
An FR95 with a polypropylene 35 micron filter, plain bonnet, wrench-style knob, Buna N relieving diaphragm, no gauge, standard bowl and 60 psig range. p. 3, 6
How do I raise the output pressure on a Conoflow FR95?
Turn the knob or handwheel clockwise to increase the set pressure, and counterclockwise to decrease it. p. 3
Why does FR95 outlet pressure keep rising after flow stops?
The manual points to valve seat leakage; clean the parts and fit a new valve plug and filter element. p. 4
What is the maximum inlet pressure of the FR95?
250 psig (1724 kPa). p. 1
Which repair kit fits an FR95 with a relieving diaphragm?
Kit G6387043, which holds items 8, 11, 12 and 14. p. 6
The whole text · 1 part
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file