Page 1 of Series 1 480 VAC

Spec sheet · Crydom

Series 1 480 VAC

Spec sheet5 pagesPDF 735 KB

Datasheet for Crydom Series 1 480 VAC panel mount solid state relays, 12A to 90A, including the 50A AC-controlled A4850.

Download the PDF735 KB

Covers · 1 model

The models it covers

Summary

What is in it

Crydom's datasheet for the Series 1 480 VAC panel mount solid state relays, with SCR outputs rated 12A to 90A at 80-530 VAC and DC (D prefix) or AC (A prefix) control, including the A4850 (50A, 90-280 VAC control). It gives product selection, output, input and general specifications, notes, wiring diagram, mechanical drawing, thermal derating, agency approvals, safety warnings and environmental information.

From the sheet · read page by page

Key facts from this sheet

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

Crydom data sheet for the Series 1 480 VAC panel mount units with SCR output, in DC control (D prefix) and AC control (A prefix) models up to 90A. It gives product selection, output, input and general specifications, notes, agency approvals and safety warnings. Its selection table prints A4850 under both the 50A and the 75A columns, so the current rating of the A4850 is not stated here.

Type
Series 1 480 VAC panel mount unit with SCR output for heavy industrial loads p. 1, 4
Load voltage
80-530 VAC p. 1
Control input
A prefix: AC control, 90-280 Vrms (60Hz); 2.0 mA @ 120 Vrms, 4.0 mA @ 240 Vrms p. 2
Output switching
Series offers zero-crossing (resistive loads) or random-fire (inductive loads) output p. 1
Terminals
Screw and saddle clamps furnished, unmounted; 6-32 screws 10 in/lbs, 8-32 and 10-32 screws 20 in. lbs. p. 2
Weight
3 oz (86.5g) typical p. 2
Encapsulation
Thermally conductive epoxy p. 2
Input circuit
Active current limiter in the input circuitry p. 2
Series models
DC control: D4812, D4825, D4850, D4875, D4890; AC control: A4812, A4825, A4850, A4890 p. 1
Agency approvals
Files E116949, LR81689 and 10143 UG (not applicable to -B and 4D) p. 3

What this sheet walks you through

  • Choosing a model by control voltage and current p. 1
  • Output, input and general specifications p. 1, 2
  • Safety warnings for installing and handling the unit p. 4

Good to know

  • Heat sinking is required; derating curves are given on page 3 of the sheet. p. 2
  • All parameters are at 25°C unless otherwise specified. p. 2
  • The 50A model has double faston pairs, and both pairs must be connected. p. 2
  • Disconnect all power before installing or working on the unit, and replace all covers before turning power on. p. 4
  • The side panels may be hot; let the unit cool before touching it. p. 4

Questions this sheet answers

What control voltage does the Crydom A4850 need?

A prefix models are AC controlled with 90-280 Vrms (60Hz) on the input. p. 2

What load voltage can a Crydom Series 1 480 VAC unit switch?

80-530 VAC. p. 1

Does the Crydom A4850 need a heat sink?

Yes, the sheet says heat sinking is required and refers to its derating curves. p. 2

How tight should the Crydom Series 1 terminal screws be?

6-32 screws 10 in/lbs; 8-32 and 10-32 screws 20 in. lbs. p. 2

The whole text · 1 part

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 51-5

The file

Revision and size

RevisionRev. 062211
PublisherCrydom Inc.
Pages5
PDF735 KB
TextText from the PDF itself; pages 4 and 5 are scans, read by OCR, which may hold reading errors.

The first pages · 4 of 5

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 5
Page 2
Page 2of 5
Page 3
Page 3of 5
Page 4
Page 4of 5