Each line names its page in the PDF.

A three-page Fuji Electric catalog sheet from 2000 for the Easy Logic Controller (ELC), a small programmable relay family that includes the NQ2P10R-14C along with the NQ2P10R-14, NQ2P10R-52, NQ2P10R-52C and the NQ2P20R versions. It describes features and typical uses, and gives general and I/O specifications, dimension drawings and ordering codes.

Device
Easy Logic Controller for replacing control relays, timers and counters, programmed in relay ladder logic p. 1
Power and clock
NQ2P10R-14C: 24V DC model with real-time clock and analog inputs; DC supply range 20.4 to 28.8V DC p. 2, 3
Analog inputs
2 channels (A1 to A2), 0 to 10V DC, 8-bit resolution; only on NQ2P10R-14C and NQ2P20R-14C p. 3
Relay outputs
10A at 250V AC or 8A at 30V DC per point p. 2
Program
Ladder or function block, 240 steps (4 elements x 60 lines), built-in EEPROM with no battery backup, memory pack option p. 2, 3
Operating temperature
0 to 55°C, 20 to 90%RH no condensation p. 3
Timers and counters
15 timers, 8 counters and 8 program timers p. 2
DC input levels
ON 15 to 28.8V, OFF 0 to 5V p. 3
Size
10-point type 72 × 90 × 57mm; 20-point type 126 × 90 × 57mm p. 2
Mounting
Screws or DIN rail, no special clamps p. 2
Construction
IP20 p. 3
Display
Front monitoring screen showing I/O, internal relays, timers, counters, analog values, clock time and the logic in operation p. 2
Clock function
Models with RTC run daily or weekly schedules and include daylight saving time p. 2
Interface port
For a loader or memory pack; loader software saves programs and simulates the logic on a PC p. 2

What this sheet walks you through

  • Typical uses such as pumps, gates, lighting and ventilation p. 1
  • Writing control logic in ladder diagram format p. 2
  • General and I/O specifications p. 3
  • Dimensions of the 10-point and 20-point units p. 3
  • Ordering codes for the ELC range and accessories p. 3

Good to know

  • Wiring should be done only by qualified engineers with electrical knowledge. p. 3
  • Analog inputs are available only on the -14C models. p. 3

Questions this sheet answers

What power supply does the NQ2P10R-14C need?

It is the 24V DC model; the DC supply range is 20.4 to 28.8V DC. p. 2, 3

Does the NQ2P10R-14C have analog inputs?

Yes. It has 2 analog channels, 0 to 10V DC with 8-bit resolution. p. 3

How much current can the Fuji ELC relay outputs switch?

Each output relay switches 10A at 250V AC or 8A at 30V DC. p. 2

Does the Fuji ELC need a battery to keep its program?

No. The program is stored in EEPROM, which needs no battery backup. p. 2

How is the Fuji Easy Logic Controller programmed?

In relay ladder logic, with Windows programming software or directly on the front panel. p. 1

The file

Size and text

Pages3
PDF263 KB
TextText from the PDF itself.

Every page · 3

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Fuji Electric NQ2P10R-14C Spec Sheet

The text of page 1, from the PDF itself

Fuji Easy Logic Controller R

ELC

The ELC incorporates a weekly time-setting function that allows you to configure several control logic sequences based on time. Ideal for replacing control relays, timers and counters. The ELC is programmed in Relay Ladder Logic using a Windows programming software or directly on the front panel. These are just a few of the many ELC applications:

  • ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
  • Opening/closing control of doors, gates and shutters ● Pump control for supplying and draining water
  • Garbage/waste disposer control ● Illumination control of streetlights, show windows and signboards ● Temperature control in greenhouses and plant watering control ● Boiler control
  • Parking area monitoring ● Air ventilation system control ● Escalator control
  • Mixing and stirring control for various solvents ● Transfer conveyor and sorter control, etc. LAH110a
Page 2 of Fuji Electric NQ2P10R-14C Spec Sheet

The text of page 2, from the PDF itself

4/8 power relays, 15 timers, 8 counters and 8 program timers are packed into a single ELC.

SAVE SPACE, REDUCE COST, REDUCE WIRING, LOWER ENERGY CONSUMPTION, SAVE TIME ••••• •The ELC will help improve productivity. Digital input terminals

Drastically reduce the size of your control panel! COMPACT

The ELC has an extremely compact size. The 10-point type is only 72 × 90 × 57mm and the 20-point type is only 126 × 90 × 57mm in size. This compact size contributes to the drastic reduction of control panel dimensions

  • For example, if a control circuit including 3 timers and 4 power relays are replaced with the ELC (10 points type), the mounting space may be reduced by about 50%!

Power supply terminals

Analog input terminals

Power supply terminals for 100 to 200V AC and 24V DC.

Model with 24V DC RTC comes standard with analog inputs.

  • About 50%

Monitoring screen

SAVE SPACE

  • (Compared to Relays, Timers, Counters combined)

Screen displays logic diagram and monitoring operating conditions.

Reduce hardware cost! COST DOWN

Digital output terminals Power relays with large capacity of 10A are provided onboard.

  • For example, if a control circuit including 3 timers and 4 power relays are replaced with the ELC (10 points type), the cost will be reduced by about 20%!

Reduce wiring time When individual Relays, Timers and Counter are used the wiring of each component becomes tedious. The ELC can drastically reduce the wiring the because only 1 component is involved. Further more, if changes to the logic need to be made these can be done in software or via the front panel.

Special mounting hardware is not required

The monitoring screen on the front of the ELC indicates to the user the total status of the ELC at a glance. This screen displays the status of I/Os, internal relays, timers, counters, the analog current values and the clock time, as well as a monitoring screen of the control logic operation.

The ELC can be mounted with screws on sliding type mounting holes as well as DIN rails without using any special mounting clamps.

Control logic is easily configured in ladder diagram format with software

Since software information is stored into an EEPROM that does not require battery backup, the ELC is maintenance free.

Large power output relays with switching capacity of 10A are provided The ELC includes large power output relays with a per point switching capacity of 10A at 250V AC, or 8A at 30V DC. These output relays can be directly connected to illumination lamps and valves for control.

Schedule management is achieved by using clock function

Improve Productivity

Energy-saving operation.

LOWER ENERGY CONSUMPTION

The ELC can be programmed to save electricity. A time management function can be programmed to shutdown Fans, Lights, etc. to save energy.

TIME

SAVE TIME

The ELC comes standard with Relay Ladder logic schemes for control applications. The ELC can easily copy logic schemes by using the optional memory pack. The control logic connections take considerably less time to implement than traditional hard-wiring.

An interface port is provided for connection to a loader or to attach a memory pack.

Monitoring screen displays all operating conditions

Control logic wiring in the ELC is implemented with software in a ladder diagram format that is developed from a traditional relay schematic diagram. The user only needs to program the ELC in Relay Ladder Logic.

REDUCE WIRING

SAVE ENERGY

Operation switches are used for writing logic and setting timers and counters.

Interface port

The ELC has an attractive price to help your bottom line. Please contact Fuji Electric for more detail.

REDUCE COSTWIRINGOperation switches

The ELC’s equipped with RTC allow the user to program a daily or weekly control schedule without expensive time management system. Also, the ELC incorporates day light savings time.

2 channel analog inputs are standard (DC 24 V, with RTC) The ELC comes equipped with 2 channel analog inputs standard. Simple control of analog applications, such as temperature, speed, and voltage can be achieved without any optional analog device.

Password feature is provided for security The ELC contains a password feature for preventing unexpected modification of software with switch operation.

Maintenance-free EEPROM is used

Complies with CE marking and UL/cUL standards The ELC is widely applicable throughout the world, with various global standards such as CE marking and UL.

Software data saving with loader and simulation via personal computer can be done Software data can be saved by using the loader software program. The data will help the user to standardize wiring diagrams. Also, the configured logic can be simulated in a personal computer, and therefore performance of the logic scheme in the ELC can be verified prior to installation.

Page 3 of Fuji Electric NQ2P10R-14C Spec Sheet

The text of page 3, from the PDF itself

  • Specifications
  • General specifications NQ2P10R-14 NQ2P20R-14 NQ2P10R-52 NQ2P20R-52 85 to 264V AC Power supply voltage 20.4 to 28.8V DC 2W 3W 3VA 7VA Power consumption Max. 10A Output current Electrostatic discharge IEC801-2 Severity3 Contact discharge ±4kV, aerial discharge ±8kV Radioelectromagnetic field IEC801-3 10V/m IEC801-4 Severity3 2kV Operating ambient 0 to 55˚C temperature 20 to 90%RH no condensation Relative humidity IEC68-2-6 9.8m/s2 Vibration IEC68-2-27 147m/s2 Shock IP20 Construction

Programming language Program memory capacity Backup Input relay Output relay Auxiliary relay RTC relay Counter Timer Analog comparison Analog input RTC

  • I/O specifications
  • Dimensions (mm) 2-φ4.5 2-M4x12 L

NI1I2I3I4AC 100〜240VI5I6Input 6xACDELSELESCOK100 90TimeRy Power

10R-52C Output 4×Relay/10A

Q1Q2Q3Q460 725252-φ4.5 2-M4x12 LNI1AC 100〜240VI2I3I4I5I6I7I8I9IAIBICInput 12xACOutputTimeRy PowerDELSELESCOK100 90Input

NQ2P10R-14 NQ2P20R-14 NQ2P10R-52 NQ2P20R-52 12points(10points**) 6points 12points No. of input points 6points 0 to 28.8V DC 0 to 265V AC Rated voltage 3mA/24V 0.5mA/110V 1mA/110V Rated current 1mA/230V 2mA/230V ON:79 to 265V Operating voltage ON:15 to 28.8V OFF:0 to 5V OFF:0 to 40V OFF➝ON:3ms OFF➝ON:50ms Delay time ON➝OFF:5ms ON➝OFF:50ms 0 to 10V DC Analog voltage* Resolution:8bits 8points 4points 8points No. of output points 4points 10A/250V AC or 8A/30V DC Load current

NQ2P RNQ2P R- C Ladder, function brock 240steps (4elements x 60lines ) Built-in EEPROM, memory pack option 12points (I1 to C) 8points (Q1 to Q8) 15points (M1 to MF) 8points (R1 to R8) 15points (C1 to C8) 4points (T1 to TF) 4points (G1 to G4) ✕ 2channel (A1 to A2) only for DC ✕

*Analog input: only for NQ2P10R-14C, NQ2P20R-14C **NQ2P20R-14C

20R-52C Output 8×Relay/10A

Q1Q2Q3Q4Q5110 126Q6Q7Q88 525

  • Products Item TimeRy Power

Loader software Memory pack

Ordering code (Product code) NQ2P10R-14 NQ2P10R-14C NQ2P10R-52 NQ2P10R-52C NQ2P20R-14 NQ2P20R-14C NQ2P20R-52 NQ2P20R-52C NQ4H-SE NQ8P-MP

Specifiction 24V DC power supply, input 6points, output 4points Ry10A, no clock function 24V DC power supply, input 6points, output 4points Ry10A, clock function, analog 2channel 100 to 240V AC power supply, input 6points, output 4points Ry10A, no clock function 100 to 240V AC power supply, input 6points, output 4points Ry10A, clock function 24V DC power supply, input 12points, output 8points Ry10A, no clock function 24V DC power supply, input 10points, output 8points Ry10A, clock function, analog 2channel 100 to 240V AC power supply, input 12points, output 8points Ry10A, no clock function 100 to 240V AC power supply, input 12points, output 8points Ry10A, clock function Personal computer loader software (with connection cable) For program saving and transferring

Safety Considerations

  • For safe operation, before using the product read the instruction manual or user manual that comes withthe product carefully or consult the Fuji sales representative from which you purchased the product.
  • Some of the products listed in this catalog may have limits on their use or location or may require periodic inspections. Call Fuji's sales representative for further information.
  • For safe operation, wiring should be conducted only by qualified engineers who have sufficient technical knowledge about electrical work or wiring.
  • Appearance and specifications are subject to change without prior notice for the purpose of product improvement.

Fuji Electric Corp. of America

Fuji Electric Co., Ltd.

Park 80 West Plaza II Saddle Brook, NJ 07663, U.S.A. Phone: (201) 712-0555 Fax: (201) 368-8258 URL: http://www.fujielectric.com

ED & C・Drive Systems Company

Materials covered in this document are subject to revision due to the modification of the product.

Gate City Ohsaki, East Tower 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032, Japan Phone: +81-3-5435-7135~8 Fax: +81-3-5435-7456~9 URL: http://www.fujielectric.co.jp/edc/ Printed in Japan 2000-12 (L00a/H00) M50 FIS