Spec sheet · GE
Renewal Parts: CR120A, CR120C, and CR122A 300 volt industrial relay
Spec sheet6 pagesPDF 600 KB
Renewal parts bulletin for General Electric CR120A, CR120C latched and CR122A time delay 300 volt industrial relays, with coil tables.
Covers · 1 model
The models it covers
Summary
What is in it
General Electric renewal parts bulletin for the CR120A 300 volt industrial relay, the CR120C latched relay and the CR122A pneumatic time delay relay. It explains how to read the complete catalog number, suggests stand-by stock quantities, and lists part numbers by form for movable contact arms, molded retainers, connecting straps, contact sets and kits, accessories, and replacement AC operating coils by voltage and frequency.
From the sheet · read page by page
Key facts from this sheet
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
A General Electric renewal parts bulletin (GEF-4247C, printed 7/78) for the CR120A, CR120C and CR122A 300 volt industrial relays: the standard relay, the CR120C latched relay and the CR122A time delay relay. It explains how to read a catalog number, lists contact arms, retainers, connecting straps, contact kits, accessories and replacement AC coils by catalog number, and suggests stand-by stock. The text was read by OCR from a scan and the quantity tables are garbled.
- Device
- 300 volt industrial relay; renewal parts for CR120A relays, CR120C latched relays and CR122A time delay relays p. 1, 3
- Enclosure code
- 0 after CR120A means no enclosure, 1 means NEMA Type 1 general purpose enclosure; parts are identical for both p. 2
- AC coils, line voltage
- Suffix 02: 115 V 60 Hz, 55-000001G002; 03: 230 V 60 Hz, 55-000001G003; 07: 110 V 50 Hz, 55-000001G007; 08: 230 V 50 Hz, 55-000001G008 p. 5
- AC coils, low voltage
- Suffix 21: 48 V, 55-000001G021; 23: 32 V, 55-000001G023; 24: 24 V, 55-000001G024; 45: 12 V, 55-000001G045; 46: 6 V, 55-000001G046 (all 60 Hz) p. 5
- Contact sets
- Contacts, springs and screws: one-pole set 55-153944G001, four-pole kit 55-153944G002 (forms AA, AC) p. 1
- Contact arms
- Complete movable contact arm for 2-pole relay 55-153944G012, for 4-pole relay 55-153944G003, for 2-pole adder 55-153944G004 p. 2
- Molded retainers
- 2-pole relay 55-651401P003; 4-pole relay 55-650378P003 (white marking strip) p. 2
- Adder strap
- Connecting strap for a 2-pole adder 55-153576P001 p. 2
- Latched relay parts
- CR120C: 2-pole contact arm only for the 2-pole latch accessory 55-153944G010; molded link 55-501868P001 p. 3
- Time delay arm
- CR122A: 2-pole contact arm for the time delay accessory 55-153944G015 p. 3
- Accessories
- Trough cover CR120X12A, retaining shield CR120X11A, bracket kit CR120X13A p. 1
- Contact conversion
- Contact arms ship with all movable contacts in the N.O. position and can be converted to N.C. by the user p. 2
What this sheet walks you through
- Reading a complete catalog number to find the right parts p. 1
- Parts for CR120A relays p. 2
- Parts for CR120C latched relays p. 3
- Parts for CR122A time delay relays, delay on energization or de-energization p. 3, 4
- Choosing a replacement AC operating coil from the coil suffix p. 5
- Stocking spare parts for stand-by service p. 1
Good to know
- DC coils are not field replaceable. p. 5
- Before installing in a nuclear application, confirm the product is intended for that use. p. 1
- For foreign applications the bulletin suggests doubling the stand-by stock quantities. p. 1
Questions this sheet answers
What replacement coil does a CR120A02002AA relay use?
Coil suffix 02, rated 115 volts 60 hertz; the replacement coil is 55-000001G002. p. 5
Can I replace the DC coil on a CR120 relay?
No. The bulletin states that DC coils are not field replaceable. p. 5
What does the 0 or 1 after CR120A mean?
0 means no enclosure and 1 means a NEMA Type 1 general purpose enclosure; the parts are the same for both. p. 2
Can CR120 contacts be changed from normally open to normally closed?
Yes. The contact arms come with movable contacts in the N.O. position and the user can convert them to N.C. p. 2
The whole text · 1 part
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file