Page 11

Chapter 1

1.2

Overview

Features This section explains the features and major applications of the CV-301 compact vision system.

1.2.1 Features

1

New system has achieved high differentiation ability as well as stability. (Patent-pending) •

Only the target color can be reliably extracted. The CV-301’s color processing enables reliable differentiation between yellow and white, dark blue and black, or gold plating and silver plating. These colors cannot be differentiated using monochromatic or gray processing.

•

No detection error due to the shadow on a target surface. If there is a color difference, the CV-301 can differentiate the target regardless of the variation of illumination distribution, the decrease in light quantity, or the shadow on a target surface caused by differences in individual targets.

■ Operating principle

A/D conversion

Difference calculation

B G R

R–G B–G R–B

Camera

Extraction and differentiation

Tolerance setting

Image processing

Determination and output

Determination result output Data output

The image input circuit converts the camera’s analog signal of the color image into digital signals, R, G, and B. The CV series also calculates the difference between these values (R-G, B-G, and R-B), and uses these 6 parameters to extract the color that matches the one on the screen within the preset tolerance. The above operation has made high-speed processing and stable extraction of even dark colors possible.

Extraction with a simple click: Setup time is greatly reduced. (Patent pending) •

Just click the color on the screen that you need to extract.

•

To specify the color to be extracted, place the cursor on the color and click the mouse button like you would in a Windows application.

•

The auto-extraction function and zoom function allow simple sensitivity adjustment.

Wide applications from presence/absence detection to positioning •

Presence/absence detection: Area mode (position adjustment function provided)

•

Positioning:

Absolute position detection mode

•

Displacement detection:

Relative position detection mode

➮

Refer to page 18 for a description of each mode.

3

Page 12

Chapter 1

Overview

1.2.2 Application Examples Detecting shelf life printing

1

Checking for different package types k Mil k Mil k Mil

Area Detects the presence/absence of shelf life printing or unclear characters.

Area Differentiates different package types by the color of the package.

Checking for medication information inserts

Detecting bad mark on IC

Med icine Med icine Med icine

4

Area Detects a missing information insert by the difference between the color of the paper and the cap.

Area Detects a bad mark on a defective product without being affected by the background characters.

Detecting stain on sheet material

Checking for lack of plating

Area Detects stain on sheet material by the difference in color.

Area Differentiates between gold and silver to detect the lack of plating.

Page 13

Chapter 1

Detecting target for robot handling

Overview

Detecting marks on packaging material

1

Absolute position Controls robot handling using the position detection data.

Absolute position Detects marks on packaging material without being affected by the background print pattern.

Detecting misaligned labels

Checking liquid level

Tea Tea Tea

Relative position Detects a displaced label on a bottle in the up/down/right/left direction.

Relative position Determines the liquid level by the relationship between the position of a bottle cap and a liquid surface.

■ Reference pages for each mode Mode

Description

Area

Page 18

Absolute position

Page 20

Setup procedure Page 19 in Quick Guide, Page 32 in Instruction Manual (this manaul) Page 42 in Instruction Manual (this manaul)

Relative position

Page 20

Page 42 in Instruction Manual (this manaul)

5

Page 14

Chapter 1

Overview

1.2.3 Application in a Complete System

Personal computer Controls the CV-301 and collects data through the RS-232C interface.

1

Indicator, buzzer Issues an alarm depending on the comparator output.

Control output Remote control console (accessory)

Photoelectric sensor, proximity sensor Detects a target and sends a signal to the trigger input terminal.

Trigger input

Controller CV-301

24 VDC power supply [600 mA min.]

Monitor cable (cable length: 2 m) (accessory)

Programmable logic controller Captures the control output, changes the program Nos., and reads the coordinate data.

TFT Color Monitor CV-M30 (Optional)

Camera CV-030 (The lens is optional.)

6

Page 15

Chapter 1

1.3

Overview

Part Names and Functions The following illustration shows the part names and functions of the CV-301 . ■ Controller Input/output terminal Used to input/output signals. Power input terminal (24 VDC, 0 V) The input terminal of the 24 VDC (600 mA) power supply

Modular connector Connected to the remote control console or the RS-232C communication cable.

Power indicator Illuminates when power is supplied.

I/O connector Used to input/output data.

Power supply unit (Option)

Camera (CV-030) Color, 240,000 pixel CCD camera

1

Video output terminal (RCA connector) Connected to a monitor.

Camera connector Connected to the camera cable.

Remote control console Selects a target or sets a menu item.

TFT Color Monitor CV-M30 (Option) Displays images captured with the camera or shows setting menus. Lens (Option) Brightness and focus are adjusted using a diaphragm ring and a focus ring.

7

Page 16

Chapter 1

1.4

Overview

Operation Flow This section describes the general operation flow for detection using the CV-301. Chapter 2

1

Connecting devices ➞ Page 10 Connect the remote control console, camera, and monitor to the controller.

▲ Mounting camera ➞ Page 12 Mount the camera and attach the lens.

▲ Chapter 3

Selecting measurement mode ➞ Page 18 Select the measurement mode best suited to your application.

Chapter 4

Basic setting ➞ Page 27 Operate the remote control console for the detection setting.

▲ ▲ High precision setting ➞ Page 53 Use various functions such as shutter speed selection or position adjustment.

▲

▲ Chapter 5

Operating CV-301 ➞ Page 79 Detect a target with the preset parameters.

▲ Using RS-232C ➞ Page 83 Save and load the preset parameters and output the measured value to a PC.

▲ Chapter 7

8

▲

Chapter 6

Outputting data ➞ Page 93 Use the I/O terminals or I/O connectors to provide comparator output and numerical value output.

Page 17

Chapter 2 Preparation Explains how to connect and install the CV-301, how to select lenses, and provides information about illumination.

2.1

Connection .......................................................................... 10

2.1.1 2.1.2 2.1.3 2.1.4 2.1.5

Connecting Cables ................................................................ 10 Mounting Controller ............................................................... 11 Mounting Camera .................................................................. 12 Selecting Lens ....................................................................... 13 Checking Connection ............................................................. 15

2.2

Illumination .......................................................................... 16

Page 18

Chapter 2

2.1

Preparation

Connection This section describes how to connect cables, mount the controller and camera, and select a lens.

2.1.1 Connecting Cables CAUTION

Be sure to turn off the controller before connecting cables. If you connect the cables while the controller is turned on, the camera or peripheral equipment may be damaged.

2 Input/output terminal

Remote control console Controller

Power supply unit

Modular connector

RCA connector Monitor Camera Camera cable connector

1. Insert the connector for the camera cable. 2. Insert the modular connector for the remote control console cable. 3. Insert the RCA connector for the monitor cable. 4. Connect the cable for the power supply unit. Connect the controller’s input/output terminals number 1 and 2 with the 24 VDC power supply unit. Do not turn on power until the mounting procedure is completed. 1: 24 VDC 2: 0 V

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

10

Page 19

Chapter 2

Preparation

2.1.2 Mounting Controller ■ DIN rail mounting The controller is designed to be mounted to the DIN rail. To mount or dismount the controller, move the claw at the bottom of the controller in the direction of the arrow.

2 Retractable mounting claw

■ Screw mounting Pull out the four mounting brackets and mount the controller using screws.

Retractable mounting bracket

■ Mounting position Mount the controller with the front facing the operator or facing up. Horizontally with front facing operator:

With front facing up:

Vertically with front facing operator:

With front facing down:

Correct

Correct

Correct

Incorrect

Allow sufficient space for ventilation (approx. 30 mm) around the controller.

CAUTION

• •

Do not place the controller upside down. Do not block the ventilation slots, as this may cause the controller to stop operating.

11

Page 20

Chapter 2

Preparation

2.1.3 Mounting Camera 1. Mount a lens to the camera. Select a lens based on the target size and the distance between the lens and the target. ➮ Refer to the next page.

Lens

2 2. Secure the camera. The following two methods can be used to secure the camera. ● Using the included plastic fitting The plastic fitting has the following screw holes. Use the appropriate ones to secure the camera. 1) Screw hole for tripod (1/4-20 UNC): 1 2) M3 screw holes: 2 3) M4 screw holes: 2 M3 screw holes

2) M3 screw holes

Plastic fitting

3)M4 screw holes 1) Screw hole for tripod Included screws (M3 x 6) and washers

● Using the included mounting bracket The mounting bracket has the following screw hole and slots. Use the appropriate ones to secure the camera. 1) Screw hole for tripod (1/4-20 UNC): 1 2) 4 mm diameter slots: 2 M3 screw holes

1) Screw hole for tripod

Mounting bracket

2) 4 mm diameter slots Included screws (M3 x 6) and washers

CAUTION

12

Be sure to insulate the camera when mounting it. Otherwise, the internal circuit of the camera may become damaged.