The text of a manual · part 5 of 9
Compact Color Vision System CV-301 Series Instruction Manual, pages 41 to 50
Pages 41 to 50 of 86
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Keyence CV-301
Page 41
Chapter 4
Setting procedure
4.3.2 Setting Parameters and Procedure Setting parameters The following is the layered structure of the parameters for the [AREA•CON] mode setting. The parameters in bold type are described in the basic setting. To set parameters other than those shown in bold type, refer to pages 53 through 71.
PROG No MODE
Mode selection AREA•CON AREA•TRG AREA+POS ABS•POS REL•POS
SHUTTER REGISTER WINDOW1 MEASURE 000000
WINDOW1 COLOR
SELECT SEN•5
TOL H=000000
BACK•BK
L=000000
AUTO
ILLU T=000000 RAW SCRN
COPY
Color extraction menu Specify the color to be extracted.
4
IGNORE
REGISTER ZOOM
Main menu MEASURE
SQR CL
MASK
SQR CL
DETECT MEASURE 000000
Coordinate Set measurement value setting window
Set mask Coordinate value setting window
COLOR BACK
TOL H=000000 L=000000 Window menu Set the color to be extracted, window size, and tolerance for each window.
33
Page 42
Chapter 4
Setting procedure
Basic setting 1. Determine the program No. You can set 16 programs (numbers 0 to 15). 1) Move the ENT key up or down to place the cursor on “No.”.
ENT
PROG No 0 MODE
2) Press the ENT key. Now you can change the program number. ENT
3) Move the ENT key up or down to select the number.
PROG ENT
4
No 1 MODE
4) Press the ENT key to choose the desired selection. ENT
Reference: Program numbers can be changed using the I/O terminals (➮ Refer to pages 95 and 99.). 2. Select the measurement mode. 1) Move the ENT key down to place the cursor on “MODE”.
ENT
PROG No 1 MODE
2) Press the ENT key. The cursor moves one line down. ENT
3) Move the ENT key up or down to select “AREA•CON”.
PROG ENT
No 1 MODE AREA•CON
4) Press the ENT key to choose the desired selection. The cursor returns to “MODE”. ENT
34
Page 43
Chapter 4
Setting procedure
3. Register the screen. Store the image to be used for the setting in the memory. 1) Move the ENT key down to place the cursor on “REGISTER”.
ENT
MODE AREA•CON SHUTTER REGISTER
2) Press the ENT key. The message “REGISTER SCREEN N/Y” appears To cancel the screen registration, press the ENT key while “N” is selected. PROG No 0 MODE AREA•CON SHUTTER REGISTER
ENT
ERASE SCREEN N / Y
WINDOW 1 MEASURE 09297 TOL H= 005000 L = 000000 ILLU OFF T=000017 RAW SCRN ●-------
4
3) Move the ENT key right to select “Y”. ENT
4) Press the ENT key. The current screen is stored in the memory. ENT
Note: The registered screen is available in any of 16 programs, and remains until you cancel and register new one. 4. Set [COLOR] for [WINDOW1]. Set the color to be extracted. 1) Move the ENT key up or down to place the cursor on “WINDOW1”. The menu changes. The cursor is placed on “WINDOW1”. ENT
WINDOW 1 MEASURE 000000
2) Move the ENT key down to place the cursor on “COLOR”. ENT
WINDOW 1 COLOR
3) Press the ENT key. The menu changes. The cursor is placed on “SELECT”. ENT
SELECT SEN • 5
35
Page 44
Chapter 4
Setting procedure 4) Press the ENT key. The arrow cursor appears on the screen. PROG
ENT
WINDOW 1 COLOR SEN • 5 BACK • BK IGNORE AUTO COPY REGISTER ZOOM 1 244, 208 T=000017 PROCES1 •-------
5) Move the ENT key in any direction to move the arrow cursor to the color to be extracted. ENT
6) Press the ENT key.
4
•
The screen changes to Processed Screen 1 and the background becomes black.* Only the extracted color is faintly displayed. Pressing the ENT key makes the color clearer. ENT
WINDOW1 COLOR
SEN • 5 BACK • BK IGNORE AUTO COPY REGISTER ZOOM 1
SEN • 5 BACK • BK IGNORE AUTO COPY REGISTER ZOOM 1
▲
PROG
WINDOW 1 COLOR
244, 208
244, 078
T=000017 PROCES1 ●-------
T=000017 PROCES1 ●-------
•
If there is another area which contains the color to be extracted, place the arrow cursor on the area and press the ENT key.
•
Press the CLEAR key to undo the last key operation. The clear key can be used to undo up to 5 previous steps.
*
The background becomes black because “BK” (black) is selected in “BACK” (background) in the menu. (Refer to page 63.)
7) Press the ESCAPE key. The cursor goes to “SELECT”. ESCAPE
36
PROG
Page 45
Chapter 4
Setting procedure
■ To zoom in on the image The image can be zoomed in during the color extraction.
ZOOM
1
Zoom factor
170,156 1) Press the TRIGGER key. The cursor goes to the number next to “ZOOM”. TRIGGER
2) Every time the ENT key is moved up, the image is zoomed in 2x, 4x, 8x, 16x, and 32x sequentially. If the ENT key is moved down, the image is zoomed out. Select the desired image size. PROG WINDOW 1 COLOR
4
ENT
SEN • 5 BACK • BK IGNORE AUTO COPY REGISTER ZOOM 1 170, 156 T=000017 PROCES1 --------
3) Press the TRIGGER key. You can continue the “SELECT” operation with the image size of the specified zoom factor. PROG
TRIGGER
WINDOW 1 COLOR
SEN • 5 BACK • BK IGNORE AUTO COPY REGISTER ZOOM 4 240, 294 T=000017 PROCES1 ●-------
5. Extract color automatically using the “AUTO” function. More stable color extraction is ensured regardless of the variation of target color or the change in illumination. It is recommended that you set “AUTO” after the color extraction. 1) Move the ENT key up or down to select “AUTO”.
ENT
IGNORE AUTO COPY
37
Page 46
Chapter 4
Setting procedure 2) Press the ENT key repeatedly. The color selected at “SELECT” is extracted. Press the CLEAR key to undo the last key operation. The clear key can be used to undo up to 5 previous steps. PROG
ENT
WINDOW 1 COLOR
SEN • 5 BACK • BK IGNORE AUTO COPY REGISTER
T=000017 PROCES1 ●-------
3) Press the ESCAPE key. The cursor returns to “COLOR”. ESCAPE
PROG WINDOW 1 COLOR
4
SEN • 5 BACK • BK IGNORE AUTO COPY REGISTER
T=000017 PROCES1 ●-------
■ To cancel the color extraction You can cancel the color selection and restart the procedure from the beginning. 1) Use the ENT key and ESCAPE key to place the cursor on “SELECT”. ENT
SELECT SEN • 5 BACK • BK
2) Hold down the CLEAR key for 2 seconds. The message “ERASE COLOR PROGRAM N/Y” appears. PROG
CLEAR
WINDOW 1 COLOR
SEN • 5 BACK • BK IGNORE AUTO COPY REGISTER
ERASE COLOR PROGRAM N / Y
3) Move the ENT key right to select “Y”. ENT
4) Press the ENT key. The color selection is canceled. ENT
38
T=000017 PROCES1 ●-------
Page 47
Chapter 4
Setting procedure
6. Set “MEASURE”. Set the window (range) for measurement. 1) Move the ENT key up or down to place the cursor on “MEASURE”.
ENT
COLOR MEASURE – – –, – – – – – –, – – –
2) Press the ENT key. The cursor goes to “SQR”. Move the ENT key up or down to select the shape of the window from “SQR” (square) or “CL” (circle). ENT
MEASURE SQR CL MASK
3) Press the ENT key. The frame of the window appears. The figure below shows a rectangular window.
4 PROG
ENT
WINDOW 1 COLOR MEASURE 200, 200 240, 240 MASK – – –, – – – – – –, – – – DETECT MEASURE 003017 TOL H=000000 L=000000 T=000017 RAW SCRN --------
4) Move the ENT key up/down/right/left and enclose the part to be detected. PROG ENT
WINDOW 1 COLOR MEASURE 200, 152 300, 304 MASK – – –, – – – – – –, – – –
DETECT MEASURE 003429 TOL H=000000 L=000000 T=000017 RAW SCRN ●-------
Every time the ENT key is pressed, the window drawing mode changes as follows. ENT
• When drawing a square window
• When drawing a circle window
39
Page 48
Chapter 4
Setting procedure 5) After setting the size and position of the window, press the ESCAPE key to exit MEASURE mode. ESCAPE
■ Mask window When a mask window ([MASK]) is created in a measurement window, the area inside of the mask window is omitted from the measurement. Draw a mask window using the same procedure as for a measurement window.
MASK – – –, – – – – – –, – – –
4
Area to be measured
Mask window [MASK]
Measurement window [MEASURE]
7. Set “TOL” (tolerance). Set the upper limit “H =” and the lower limit “L =” of the tolerance. (Units: pixels) 1) First, set the upper limit. Move the ENT key up or down to place the cursor on “H = 000000” under “TOL”. TOL H=000000 L =000000 ENT
2) Press the ENT key. “0” on the first digit is shown in reverse video. You can enter a numerical value. ENT
TOL H=000000 L =000000
3) Move the ENT key right or left to select the digit to be changed.
ENT
TOL H=000000 L =000000
4) Move the ENT key up repeatedly. The numerical value increases starting from 0. When the value goes above 9, the reverse video moves to the next digit. If you move the ENT key down repeatedly, the numerical value decreases to 0.
ENT
TOL H=005000 L =000000
5) Press the ENT key to accept the entered value. ENT
40
TOL H=005000 L =000000
Page 49
Chapter 4
Setting procedure
6) Place the cursor on “L = 000000” (Lower limit) and set the value using the same procedure as for the upper limit. ENT
TOL H=005000 L =000000
Note: If you do not know what to set the tolerance limit value at, refer to the measured value displayed in the operation check described on the following page. The upper limit cannot be smaller than the lower limit. This completes the WINDOW1 settings. In [AREA] mode, you can set up to 8 windows in a single program number. To set several windows, select another window number and repeat steps 4 through 7 in the procedure.
Operation check after setting 1. Press the ESCAPE key to return to the initial menu screen. When the initial menu screen is displayed, trigger signals are input continuously and the measured value is displayed. PROG
ESCAPE
No 0 MODE AREA•CON SHUTTER REGISTER WINDOW 1 MEASURE 006959 TOL H= 000000 L = 000000 ILLU OFF T=000017 RAW SCRN ●-------
Measured value
WINDOW1 MEASURE 004587 TOL
2. Check the detection result indicator. Green: Acceptable (The measured value is within the tolerance limits.) Red:
Not acceptable (The measured value is out of the tolerance limits.)
Detection result indicator
T=000017 RAW SCRN ●-------
Note 1: When [AREA•TRG] is selected, the measured value is displayed at the time of a trigger input. The detection result indicator is white before the first trigger input is produced. Note 2: When [AREA•CON] is selected, the measured value and the detection result is retained only while the TRIGGER key is pressed.
41
4
Page 50
Chapter 4
4.4
Setting procedure
[POS “Position detection”] Mode Setting This section describes the basic setting procedure for position detection mode using [ABS•POS “Absolute position”] mode. Both [ABS•POS] and [REL•POS “Relative position”] modes are set through the same procedure using the “POS“ (Position adjustment) menu.
4.4.1 [ABS•POS] Mode Menu The following menu is displayed after [ABS•POS] mode is set.
Program No. Up to 16 programs (numbers 0 to 15) can be registered.
4
PROG
SHUTTER Changes shutter speed.
No 0 MODE ABS•POS SHUTTER REGISTER POS•1
POS•1 (Position adjustment 1) Set parameters for position detection.
X= 000 Y= 000
Processing time Displays the processing time for each screen. (Units: ms) Detection result The color indicator shows the detection result for each window. ● (Green): Within tolerance ● (Red): Out of tolerance ● (White): No detection
ILLU OFF T=000063 RAW SCRN ●●● - - - -
MODE 4 measurement modes can be selected. Screen registration Store the image for setting. Coordinate value display Coordinate values of the results of position detection. The values are shown in pixels. Illumination adjustment function ON/OFF display
Current display Shows the current screen mode. (Raw screen, Processed screen 1, Processed screen 2)
: Window has not been determined.
Note: This photo shows all indicators lit in order to demonstrate the actual color of the detection result. In reality, only the left indicator is lit.
42