Page 81

Chapter 4

Setting procedure

4.6.2 Initialization by Program No. You can initialize the settings of one of the 16 programs. 1. Use the ENT and ESCAPE keys to place the cursor on “No”. ENT

No 1 MODE AREA•CON

ESCAPE

2. Press the CLEAR key for 2 seconds. The message “ERASE PROGRAM N/Y” appears. • •

To cancel erasing the program No., select “N” and press the ENT key. To erase the program No., select “Y” and press the ENT key. CLEAR

4

PROG No 1 MODE AREA•CON SHUTTER REGISTER

ERASE PROGRAM N / Y

WINDOW 1 MEASURE 000000 TOL H=000000 L=000000 ILLU OFF T=00017 RAW SCRN -------

73

Page 82

Chapter 4

Setting procedure

4.7 Input/Output Operation in PROGRAM Mode Even in PROGRAM mode, the CV-301 series accepts a trigger input or provides a busy output so that the measurement result and numerical value are displayed on the screen. The comparator output is not provided. This operation can be used as a test operation for adjustment. Each input/output operation in the PROGRAM mode is listed in the following table. Input terminal Input connector

Output terminal

Output connector

4

TRG PST RUN/SET C0 to C3 WO1 to WO8 WOR STO BUSY P.POLE P0 to P8 VIDEO MONO

Trigger input for timing signal Coordinate value X/Y selection input Run/Program selection input Program No. input Window comparator output Or output of WO1 to WO8 Output strobe signal Busy signal output Position data sign output Position data output Video signal output Video signal output (black-and-white output)

Enabled Disabled Disabled Disabled Disabled Disabled Disabled Enabled Disabled Disabled Enabled Enabled

Note: A trigger input is not accepted in PROGRAM mode during the setting procedure such as when drawing a window or extracting a color. A trigger input is not accepted when the remote control console’s TRIGGER key cannot be used.

74

Page 83

Chapter 4

Setting procedure

4.8 Changing Environmental Setting The environmental setting includes the white balance adjustment and external input settings. This section describes each environmental setting and the procedure to change the setting.

4.8.1 Change Environmental Setting You can set or check the following items in the environmental setting. 1. Adjust the white balance. 2. Select the option to use the remote control console or I/O connectors to change program No. 3. Change the output form. 4. Change the RS-232C communication speed. 5. Change the display language to Japanese or English.

1.

WHITE BALANCE

---

2.

CHANGE

CONSOLE

3.

OUT MODE

N.O.

4.

RS232C BPS

9600

5.

LANGUAGE

ENGLISH

4

White balance adjustment It is necessary to adjust the color of a white image to be projected white in the current illumination. This adjustment is called the white balance adjustment. Adjust the white balance whenever you change the target or the illumination. 1. In PROGRAM mode, press the ESCAPE key for 2 seconds. The environmental setting menu appears. ESCAPE

WHITE BALANCE

---

CHANGE

CONSOLE

OUT MODE

N.O.

RS232C BPS

9600

LANGUAGE

ENGLISH

2. Press the ENT key to place the cursor on “ - ” in the “WHITE BALANCE” menu. ENT

3. Move the ENT key right. “SET” appears at the cursor position.

ENT

WHITE BALANCE

SET

75

Page 84

Chapter 4

Setting procedure 4. Press the ENT key. A square frame and the message “<WHITE BALANCE> SET WHITE PAPER” appears at the center of the screen, and a rectangular window appears on the right end of the screen. Place a white paper in front of the camera. RUN

ENT

WHITE BALANCE R = 253 G = 223 B = 255

<WHITE BALANCE> SET WHITE PAPER

4 White paper

5. Press the ENT key. “O” marks appear in the menu window. When five marks appear, the white balance adjustment is completed. ENT

R = 157 G = 163 B = 160 ●●●●●

Marks

6. Press the ESCAPE key. The screen returns to the environmental setting menu. ESCAPE

Other settings 1. Set the remote control console’s slide switch to “PROGRAM”. RUN PROG

2. Press the ESCAPE key for 2 seconds. The environmental setting menu appears. The cursor is placed on the “WHITE BALANCE” setting. ESCAPE

76

WHITE BALANCE

---

CHANGE

CONSOLE

OUT MODE

N.O.

RS232C BPS

9600

LANGUAGE

ENGLISH

Page 85

Chapter 4

Setting procedure

3. Move the ENT key up or down to place the cursor on the item to be changed. Every time the ENT key is moved, the cursor moves to the next item and displays the item in reverse video. ENT

4. Move the ENT key right or left to select the desired setting. ENT

WHITE BALANCE

---

CHANGE

TERMINAL

OUT MODE

N.O.

RS232C BPS

9600

LANGUAGE

ENGLISH

4

5. Press the ENT key to accept the setting. ENT

6. Press the ESCAPE key. The screen returns to the environmental setting menu. ESCAPE

Description of each item “*” indicates the initial setting value.

Menu item

Setting

1 WHITEBALANCE, - - *

Disabled, - - SET

Enabled

Adjust white balance.

CONSOLE* 2 CHANGE TERMINAL

Description

Use remote control console to change program No. Use I/O connector to change program No.

N.O.*

Normally-open

N.C.

Normally-closed

9.600*/19,200/ 38,400

Set communication speed.

3 OUT MODE

4 RS-232C BPS

ENGLISH* 5 LANGUAGE

JAPANESE

Purpose

Use remote control console to select program No. Use I/O connector to externally select program No. in RUN mode. Provide window comparator output using a normally-open contact (output when detection result is out of tolerances). Provide window comparator output using a normally-closed contact (output when detection result is within tolerances). Change communication speed (no. of bits/sec.).

Use English language.

Change menu display to English.

Use Japanese language.

Change menu display to Japanese.

77

Page 86

Chapter 4

Setting procedure

MEMO

4

78