A three-page Keyence data sheet, dated 2018/12/12, for the FS-V33CP fiber amplifier: a main unit with an M8 connector and two PNP outputs. It lists the electrical, optical and environmental specifications and adds a dimensions drawing and an I/O circuit diagram.
- Device
- Fiber amplifier, M8 connector type, main unit, PNP output p. 1
- Control outputs
- 2 PNP open-collector outputs, 24 V, 100 mA max. (main unit alone), 20 mA max. with expansion units p. 1
- Connector
- M8 p. 1
- Power supply
- 12 to 24 VDC ±10 %, ripple (P-P) 10 % or less p. 1
- Power consumption
- Normal 830 mW max. (35 mA max. at 24 V, 45 mA max. at 12 V); power saving 660 mW max. p. 1
- Light source
- Red 4-element LED, wavelength 640 nm p. 1
- Response time
- 33 µs (HIGH SPEED), 250 µs (FINE), 500 µs (TURBO), 1 ms (SUPER TURBO), 4 ms (ULTRA TURBO), 16 ms (MEGA TURBO) p. 1
- Display
- Dual 7-segment display showing preset value (green) and current value (red), 4 digits each; current value range 0 to 64,512 p. 1
- Detection mode
- Light intensity, with area detection and automatic sensitivity tracking p. 1
- Timer
- OFF-delay, ON-delay, one-shot and combined timers, 0.1 ms to 9,999 ms p. 1
- Unit expansion
- Up to 16 expansion units (17 units in all); a 2-output type counts as two p. 1
- Size and weight
- 30.3 mm (H) x 9.8 mm (W) x 71.8 mm (D); approx. 22 g p. 1
- Environment
- -10 to +55 °C (no freezing), 35 to 85 % RH (no condensation) p. 1
- Case material
- Polycarbonate p. 1
What this sheet walks you through
- Checking the specifications of the amplifier p. 1
- Dimensions drawing p. 2
- Wiring by the I/O circuit and connection diagram p. 3
Good to know
- The total current of the two outputs should stay under 100 mA. p. 1
- With several units side by side the ambient temperature limit drops: -10 to +50 °C for 3 to 10 units, -10 to +45 °C for 11 to 16 units. p. 1
- Ganged units should be mounted on the DIN rail with mounting brackets, with output current of 20 mA or less. p. 1
- HIGH SPEED mode adds 160 mW (7 mA) to the power consumption. p. 1
Questions this sheet answers
What voltage does the Keyence FS-V33CP need?
12 to 24 VDC ±10 %, with ripple of 10 % or less. p. 1
What is the FS-V33CP response time?
From 33 µs in HIGH SPEED mode up to 16 ms in MEGA TURBO mode, in six steps. p. 1
How many expansion units can connect to an FS-V33CP?
Up to 16, for 17 units in all; a 2-output unit counts as two. p. 1
How much current can the FS-V33CP outputs switch?
100 mA max. on the main unit alone (both outputs together under 100 mA), or 20 mA max. with expansion units connected. p. 1
What size is the FS-V33CP?
30.3 mm high, 9.8 mm wide and 71.8 mm deep, weighing about 22 g. p. 1
The file
Size and text
Every page · 3
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 3
Open in the PDF
The text of page 1, from the PDF itself
Data Sheet FSV33CP Fiber Amplifier, M8 Connector Type, Main Unit, PNP
SPECIFICATIONS ModelFSV33CPType
2output with M8 connector
Output
PNP
Main unit/Expansion unit
Main unitControl output2 outputs
Monitor output (1 to 5 V)
N/A
External input Connector
M8
Light source LED
Red, 4element LED (Wavelength: 640 nm)
Response time
33 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER TURBO) /4 ms (ULTRA TURBO) /16 ms (MEGA TURBO)
Output selection
LIGHTON/DARKON (switchselectable)
Display indicator
Operation indicator: Red LED/Dual digital monitor: Dual 7segment display, Preset Value (4digit green LED indica tor) and Current Value (4digit red LED indicator) illuminated together. Current Value range: 0 to 64,512; Excess gain: 0P t o 999P, Hold function: Possible to display both peak and bottom hold values, Selectable from 5 variations Bar LED monitor: Excess gain displayed (85% to 115% in 7 steps), Scaling display
Detection mode
Light intensity (area detection possible, automatic sensitivitytracking function provided)/ [Limited light intensity/Count check/Abnormality detection]
Timer function
OFFdelay timer/ONdelay timer/Oneshot timer/ONdelay timer + OFFdelay timer/ONdelay timer + Oneshot timer , selectable Timer duration selectable: 0.1 ms to 9,999 ms, Maximum error against the setting value: ±10% max.
Control output
PNP opencollector 24 V, 100 mA max.*1 (main unit only)/20 mA max. (when the expansion unit(s) is connected), R esidual voltage: 1 V max.
External inputy
Input time: 2 ms (ON)/20 ms (OFF) min.*2
Unit expansion
Up to 16 expansion units can be connected (a total of 17 units). Note that the 2output type should be counted as t wo units.
Number of interference prevention units
Normal operation
Size Rating
Environmental resistance
HIGHSPEED:0 FINE:4 TURBO/SUPER/ULTRA/MEGA:8台 30.3 mm (H) x 9.8 mm (W) x 71.8 mm (D) 1.19" (H) x 0.39" (W) x 2.83" (D)
Power voltage
12 to 24 VDC ±10 %, Ripple (PP) 10 % or less
Power consumption
Normal: 830 mW max. (Using 24 V, 35 mA max., using 12 V, 45 mA max.)/ Power saving 660 mW max. (Using 24 V, 27 mA max., using 12 V, 32 mA max.)*3
Ambient light
Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max.
Ambient temperature
10 to +55 °C 14 to 131 °F (No freezing)*4
Relative humidity
35 to 85 % RH (No condensation)
Vibration resistance
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions
Shock resistance
500 m/s2, 3 times in each of the X, Y, and Z directions
Case materialPolycarbonateAccessoriesN/AWeightApprox. 22 g
*1 Total current of two outputs should be less than 100 mA. *2 Only available on certain models. *3 When using the HIGH SPEED mode, the power consumption increases by 160 mW (7 mA). *4 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
1 to 2 Units: 10 to +55 °C 14 to 131 °F, 3 to 10 Units: 10 to +50 °C 14 to 122 °F, 11 to 16 Units: 10 to +45 °C 14 to 113 °F
KEYENCE AMERICA 1888KEYENCE(Toll Free)
https://www.keyence.com/
2018/12/12 Page:1/3
Page2of 3
Open in the PDF
The text of page 2, from the PDF itself
Data Sheet Dimensions
- Download CAD file or product manual for larger image/text and more detail.
KEYENCE AMERICA 1888KEYENCE(Toll Free)
https://www.keyence.com/
2018/12/12 Page:2/3
Page3of 3
Open in the PDF
The text of page 3, from the PDF itself
Data Sheet I/O Circuit Connection diagram
- Download CAD file or product manual for larger image/text and more detail.
I/O Circuit
1. FSV33P only. 2. FSV33CP only. 3. FSV33P/34P only. 4. FSV33CP/34CP only.
KEYENCE AMERICA 1888KEYENCE(Toll Free)
https://www.keyence.com/
2018/12/12 Page:3/3