Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Keyence FS-V33CP Spec Sheet

Spec sheet · Keyence

Keyence FS-V33CP Spec Sheet

Spec sheet3 pagesPDF 996 KB

All 3 pages are below, each with its text.

Download the PDF996 KB

Covers · 1 model

The models it covers

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

A three-page Keyence data sheet, dated 2018/12/12, for the FS-V33CP fiber amplifier: a main unit with an M8 connector and two PNP outputs. It lists the electrical, optical and environmental specifications and adds a dimensions drawing and an I/O circuit diagram.

Device
Fiber amplifier, M8 connector type, main unit, PNP output p. 1
Control outputs
2 PNP open-collector outputs, 24 V, 100 mA max. (main unit alone), 20 mA max. with expansion units p. 1
Connector
M8 p. 1
Power supply
12 to 24 VDC ±10 %, ripple (P-P) 10 % or less p. 1
Power consumption
Normal 830 mW max. (35 mA max. at 24 V, 45 mA max. at 12 V); power saving 660 mW max. p. 1
Light source
Red 4-element LED, wavelength 640 nm p. 1
Response time
33 µs (HIGH SPEED), 250 µs (FINE), 500 µs (TURBO), 1 ms (SUPER TURBO), 4 ms (ULTRA TURBO), 16 ms (MEGA TURBO) p. 1
Display
Dual 7-segment display showing preset value (green) and current value (red), 4 digits each; current value range 0 to 64,512 p. 1
Detection mode
Light intensity, with area detection and automatic sensitivity tracking p. 1
Timer
OFF-delay, ON-delay, one-shot and combined timers, 0.1 ms to 9,999 ms p. 1
Unit expansion
Up to 16 expansion units (17 units in all); a 2-output type counts as two p. 1
Size and weight
30.3 mm (H) x 9.8 mm (W) x 71.8 mm (D); approx. 22 g p. 1
Environment
-10 to +55 °C (no freezing), 35 to 85 % RH (no condensation) p. 1
Case material
Polycarbonate p. 1

What this sheet walks you through

  • Checking the specifications of the amplifier p. 1
  • Dimensions drawing p. 2
  • Wiring by the I/O circuit and connection diagram p. 3

Good to know

  • The total current of the two outputs should stay under 100 mA. p. 1
  • With several units side by side the ambient temperature limit drops: -10 to +50 °C for 3 to 10 units, -10 to +45 °C for 11 to 16 units. p. 1
  • Ganged units should be mounted on the DIN rail with mounting brackets, with output current of 20 mA or less. p. 1
  • HIGH SPEED mode adds 160 mW (7 mA) to the power consumption. p. 1

Questions this sheet answers

What voltage does the Keyence FS-V33CP need?

12 to 24 VDC ±10 %, with ripple of 10 % or less. p. 1

What is the FS-V33CP response time?

From 33 µs in HIGH SPEED mode up to 16 ms in MEGA TURBO mode, in six steps. p. 1

How many expansion units can connect to an FS-V33CP?

Up to 16, for 17 units in all; a 2-output unit counts as two. p. 1

How much current can the FS-V33CP outputs switch?

100 mA max. on the main unit alone (both outputs together under 100 mA), or 20 mA max. with expansion units connected. p. 1

What size is the FS-V33CP?

30.3 mm high, 9.8 mm wide and 71.8 mm deep, weighing about 22 g. p. 1

The file

Size and text

Pages3
PDF996 KB
TextText from the PDF itself.

Every page · 3

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Keyence FS-V33CP Spec Sheet

The text of page 1, from the PDF itself

Data Sheet FS­V33CP Fiber Amplifier, M8 Connector Type, Main Unit, PNP

SPECIFICATIONS ModelFS­V33CPType

2­output with M8 connector

Output

PNP

Main unit/Expansion unit

Main unitControl output2 outputs

Monitor output (1 to 5 V)

N/A

External input Connector

M8

Light source LED

Red, 4­element LED (Wavelength: 640 nm)

Response time

33 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER TURBO) /4 ms (ULTRA TURBO) /16 ms (MEGA TURBO)

Output selection

LIGHT­ON/DARK­ON (switch­selectable)

Display indicator

Operation indicator: Red LED/Dual digital monitor: Dual 7­segment display, Preset Value (4­digit green LED indica tor) and Current Value (4­digit red LED indicator) illuminated together. Current Value range: 0 to 64,512; Excess gain: 0P t o 999P, Hold function: Possible to display both peak and bottom hold values, Selectable from 5 variations Bar LED monitor: Excess gain displayed (85% to 115% in 7 steps), Scaling display

Detection mode

Light intensity (area detection possible, automatic sensitivity­tracking function provided)/ [Limited light intensity/Count check/Abnormality detection]

Timer function

OFF­delay timer/ON­delay timer/One­shot timer/ON­delay timer + OFF­delay timer/ON­delay timer + One­shot timer , selectable Timer duration selectable: 0.1 ms to 9,999 ms, Maximum error against the setting value: ±10% max.

Control output

PNP open­collector 24 V, 100 mA max.*1 (main unit only)/20 mA max. (when the expansion unit(s) is connected), R esidual voltage: 1 V max.

External inputy

Input time: 2 ms (ON)/20 ms (OFF) min.*2

Unit expansion

Up to 16 expansion units can be connected (a total of 17 units). Note that the 2­output type should be counted as t wo units.

Number of interference prevention units

Normal operation

Size Rating

Environmental resistance

HIGHSPEED:0 FINE:4 TURBO/SUPER/ULTRA/MEGA:8台 30.3 mm (H) x 9.8 mm (W) x 71.8 mm (D) 1.19" (H) x 0.39" (W) x 2.83" (D)

Power voltage

12 to 24 VDC ±10 %, Ripple (P­P) 10 % or less

Power consumption

Normal: 830 mW max. (Using 24 V, 35 mA max., using 12 V, 45 mA max.)/ Power saving 660 mW max. (Using 24 V, 27 mA max., using 12 V, 32 mA max.)*3

Ambient light

Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max.

Ambient temperature

­10 to +55 °C 14 to 131 °F (No freezing)*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case materialPolycarbonateAccessoriesN/AWeightApprox. 22 g

*1 Total current of two outputs should be less than 100 mA. *2 Only available on certain models. *3 When using the HIGH SPEED mode, the power consumption increases by 160 mW (7 mA). *4 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.

1 to 2 Units: ­10 to +55 °C 14 to 131 °F, 3 to 10 Units: ­10 to +50 °C 14 to 122 °F, 11 to 16 Units: ­10 to +45 °C 14 to 113 °F

KEYENCE AMERICA 1­888­KEYENCE(Toll Free)

https://www.keyence.com/

2018/12/12 Page:1/3

Page 2 of Keyence FS-V33CP Spec Sheet

The text of page 2, from the PDF itself

Data Sheet Dimensions

  • Download CAD file or product manual for larger image/text and more detail.

KEYENCE AMERICA 1­888­KEYENCE(Toll Free)

https://www.keyence.com/

2018/12/12 Page:2/3

Page 3 of Keyence FS-V33CP Spec Sheet

The text of page 3, from the PDF itself

Data Sheet I/O Circuit Connection diagram

  • Download CAD file or product manual for larger image/text and more detail.

I/O Circuit

1. FS­V33P only. 2. FS­V33CP only. 3. FS­V33P/34P only. 4. FS­V33CP/34CP only.

KEYENCE AMERICA 1­888­KEYENCE(Toll Free)

https://www.keyence.com/

2018/12/12 Page:3/3