Manual · Keyence
Keyence N-R2 Manual
Manual4 pagesPDF 542 KB
All 4 pages are below, each with its text.
Covers · 1 model
The models it covers
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
Keyence instruction manual for the N-R2 dedicated communication unit, RS-232C output type, which links a code reader head to a host such as a PC or PLC. It covers part names, connecting the code reader and power, the I/O terminal and RS-232C pin layouts and wiring, DIN rail installation, and specifications.
- Device
- Dedicated communication unit, RS-232C output type, linking a code reader head to a PC or PLC p. 1, 2
- Heads shown
- BL Series and SR Series code readers p. 2
- Power
- 24 VDC (+10%, -20%), 380 mA or less p. 4
- Host port
- D-sub 9-pin (male), DTE, #4-40 screws; RS-232C p. 3
- Head port
- 12-pin round connector p. 2, 4
- Communication rates
- 4800, 9600, 19200, 31250, 38400, 57600 and 115200 bit/s p. 4
- Data format
- 7 or 8 data bits; none, even or odd parity; 1 or 2 stop bits; hardware, software or no flow control p. 4
- Inputs
- 2 (IN1 and IN2), bidirectional voltage input; 26.4 VDC max., 15 VDC min. ON p. 4
- Outputs
- 4 (OUT1 to 4), photo MOS relay, 30 VDC, 100 mA p. 4
- Code reader supply
- 5 VDC±5% (650 mA) p. 4
- PC cable
- OP-27937 (2 m), optional p. 3
- Operating environment
- 0 to 50°C; 35 to 85%RH, no condensation p. 4
- Mounting
- DIN rail, installed vertically p. 3
- Mass
- Approx. 135 g p. 4
What this manual walks you through
- Connecting the code reader to the head port p. 2
- Connecting the 24 VDC power supply p. 2
- Wiring the I/O terminal block inputs and outputs p. 2, 3
- Wiring the RS-232C cable to a PC p. 3
- Leaving space around the unit for ventilation p. 3
- Installing and removing the unit on a DIN rail p. 3, 4
Good to know
- Use only a 24 VDC supply; another voltage or an AC supply may cause product failure. p. 1
- Install and remove cables with the power disconnected. p. 2
- Leave 80 mm or more in front of the unit to connect the BL head. p. 3
- If the unit may exceed 50°C, use forced air cooling or better ventilation. p. 3
- Keep the communication and power cables shorter than 30 m. p. 1
Questions this manual answers
What does the Keyence N-R2 do?
It is a dedicated communication unit that connects a code reader head to a host such as a PC or PLC over RS-232C. p. 1, 2
What power does the N-R2 need?
24 VDC (+10%, -20%), drawing 380 mA or less. p. 4
What cable connects the N-R2 to a PC?
Keyence's optional cable OP-27937 (2 m) can be used to connect the unit's 9-pin RS-232C port to a PC. p. 3
Which code readers connect to the N-R2?
The system configuration figure shows BL Series and SR Series heads on its head port. p. 2
What are the N-R2 output ratings?
Four photo MOS relay outputs (OUT1 to 4), rated 30 VDC, 100 mA. p. 4
The file
Size and text
Every page · 4
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 4
Open in the PDF
The text of page 1, from the PDF itself
96M13455
Foreign Regulations and Standards UL certification
Dedicated Communication Unit RS-232C Output Type
The N-R2 complies with the following UL/CSA standards and has obtained the UL/C-UL certification.
- Applicable standards UL508, UL60950-1
- UL File No. E207185, E167973
- UL category NRAQ/NRAQ7, NWGQ2/NWGQ8
N-R2
- Pollution degree 2
- Overvoltage category I
Be sure to observe the following installation and environment conditions.
Instruction Manual
Caution - Do not connect directly to the branch circuit. This product must be supplied power by a suitable, approved isolated transformer or power supply not exceeding 200 VA max. Attention - Ne raccordez pas l'unité directement au circuit de dérivation. Ce produit doit être alimenté par un transformateur adapté, isolé et approuvé ou une alimentation ne dépassant pas 200 VA.
DANGER
Failure to follow these instructions may lead to death or serious injury.
WARNING
Failure to follow these instructions may lead to injury.
FCC regulations
CAUTION
Failure to follow these instructions may lead to product damage (product malfunction, etc.).
The N-R2 complies with the following FCC EMI regulations.
- FCC Part 15 Subpart B, Class B digital device
Note
Provides additional information on proper operation.
- This device complies with part 15 of the FCC Rules. Operation is
TIPS
Indicates useful information or information that aids understanding of text descriptions.
subject to the following two conditions: (1)This device may not cause harmful interface, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
For Safely Using the Product General precautions
- At startup and during operation, be sure to check that the functions
and performance of the N-R2 is operating properly.
- We recommend that you take substantial safety measures to avoid
any damage in the event a problem occurs.
- If the N-R2 is modified or used in any way other than described in the
specifications, its function and performance cannot be guaranteed.
- When the N-R2 is used in combination with other instruments, the
function and performance may be effected by operating conditions and the surrounding environment.
- Do not use the N-R2 for the purpose of protecting the human body.
- The information contained in this manual is subject to change without notice.
Notice
- FCC CAUTION
When this product is used under the circumstances and operating environments described below, adhere to the limitations of the ratings, take adequate measures to ensure safety such as fail-safe installations and consult a KEYENCE sales representative.
- For use under circumstances or environments which are not described in the manual
- For use with nuclear power control, railway, aircraft, vehicles, incinerators, medical equipment, entertainment equipment, safety devices etc.
- For use in applications where death or serious property damage is possible and extensive safety precautions are required.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Canada IC (Industry Canada) regulations The N-R2 complies with the following IC EMI regulations.
- ICES-003, Class B digital apparatus
CE marking The N-R2 complies with the following essential requirements of the EU Directive.
- EMC Directive
For properly using the product
CAUTION
The following harmonized standards are applied to this product in order to confirm the compliance.
- Applicable standards (EMI) EN55011, Class A EN55032, Class B
- Applicable standards (EMS) EN61000-6-2 EN61000-6-1
- Do not use the N-R2 in an environment subject to flammable, explosive, or corrosive gases.
- Be sure that all screws are tightened securely.
- Use crimp contacts of the specified size for wiring.
- The N-R2 uses a 24 VDC power supply. Using a power supply outside this range or an AC power supply may cause product failure.
- Do not disassemble or modify the N-R2. This may cause product failure.
- Locate the cables as far as possible from high-voltage lines and power lines. Otherwise, generated noise may cause product failure or malfunctions.
- The N-R2 is a precision instrument. If the unit is dropped or shock is applied, it may be damaged. Use caution when unpacking, carrying, and mounting.
- Be sure to observe all warnings, cautions, and precautions specified in the manual.
- The length of the communication and power cables should be less than 30 m.
Package Contents List Main unit
Instruction manual 96M00266
- Locate the cables as far as possible from high-voltage lines and power lines. Otherwise, generated noise may cause product failure or malfunctions.
Dedicated Communication Unit RS-232C Output Type
CAUTION
- The N-R2 is a precision instrument. If the unit is dropped or shock is applied, it may be damaged. Use caution when unpacking, carrying, and mounting.
- Be sure to observe all warnings, cautions, and precautions specified in the manual.
N-R2
Do not install the N-R2 in the following locations:
Instruction Manual
- Locations subject to direct sunlight
- Locations where the surrounding air temperature is outside the
range of 0 to +50qC or locations subject to condensation as the result of severe changes in temperature
- Locations where the ambient humidity is outside the range of 35 to 85%RH.
- Locations subject to corrosive or flammable gases
- Locations subject to dust, salts, iron dust, or oil smoke
- Locations subject to shock or vibration
- Locations subject to exposure of water, oil, or chemicals
- Locations where strong magnetic or electric fields are generated
Do not install the N-R2 in the following locations:
- Locations subject to direct sunlight
- Locations where the surrounding air temperature is outside the range of 0 to +50C or locations subject to condensation as the result of severe changes in temperature
- Locations where the ambient humidity is outside the range of 35 to 85%RH.
- Locations subject to corrosive or flammable gases
- Locations subject to dust, salts, iron dust, or oil smoke
- Locations subject to shock or vibration
- Locations subject to exposure of water, oil, or chemicals
- Locations where strong magnetic or electric fields are generated
DANGER
Failure to follow these instructions may lead to death or serious injury.
WARNING
Failure to follow these instructions may lead to injury.
CAUTION
Failure to follow these instructions may lead to product damage (product malfunction, etc.).
Note
Provides additional information on proper operation.
Foreign Regulations and Standards
- UL certification The N-R2 complies with the following UL/CSA standards and has obtained the UL/C-UL certification.
- Applicable standards
- UL File No.
- UL category
UL508, UL60950-1 E207185, E167973 NRAQ/NRAQ7, NWGQ2/NWGQ8
Be sure to observe the following installation and environment conditions. TIPS
- Pollution degree 2
- Overvoltage category I
Indicates useful information or information that aids understanding of text descriptions.
For Safely Using the Product
Caution - Do not connect directly to the branch circuit. This product must be supplied power by a suitable, approved isolated transformer or power supply not exceeding 200 VA max.
- General precautions
- FCC regulations
- At startup and during operation, be sure to check that the
The N-R2 complies with the following FCC EMI regulations.
functions and performance of the N-R2 is operating properly.
- FCC Part 15 Subpart B, Class B digital device
- We recommend that you take substantial safety measures to
avoid any damage in the event a problem occurs.
- Canada IC (Industry Canada) regulations
- If the N-R2 is modified or used in any way other than described in
The N-R2 complies with the following IC EMI regulations.
the specifications, its function and performance cannot be guaranteed.
- ICES-003, Class B digital apparatus
- When the N-R2 is used in combination with other instruments, the
function and performance may be effected by operating conditions and the surrounding environment.
- Do not use the N-R2 for the purpose of protecting the human body.
- The information contained in this manual is subject to change without notice.
- CE marking
- Notice
- Applicable standards (EMI)
The N-R2 complies with the following essential requirements of the EU Directive.
- EMC Directive (2004/108/EC)
The following harmonized standards are applied to this product in order to confirm the compliance.
When this product is used under the circumstances and operating environments described below, adhere to the limitations of the ratings, take adequate measures to ensure safety such as fail-safe installations and consult a KEYENCE sales representative.
- Applicable standards (EMS)
EN55011, Class A EN55022, Class B EN61000-6-2 EN61000-6-1
- The length of the communication and power cables should be less than 30 m.
- For use under circumstances or environments which are not
described in the manual
Package Contents List
- For use with nuclear power control, railway, aircraft, vehicles,
incinerators, medical equipment, entertainment equipment, safety devices etc.
Main unit
Instruction manual
- For use in applications where death or serious property damage is
96M00266
- Locate the cables as far as possible from high-voltage lines and power lines. Otherwise, generated noise may cause product failure or malfunctions.
Dedicated Communication Unit RS-232C Output Type
possible and extensive safety precautions are required.
CAUTION
- The N-R2 is a precision instrument. If the unit is dropped or shock is applied, it may be damaged. Use caution when unpacking, carrying, and mounting.
- Be sure to observe all warnings, cautions, and precautions specified in the manual.
N-R2
Do not install the N-R2 in the following locations:
Instruction Manual
- Locations subject to direct sunlight
- Locations where the surrounding air temperature is outside the
range of 0 to +50qC or locations subject to condensation as the result of severe changes in temperature
- Locations where the ambient humidity is outside the range of 35
to 85%RH.
- Locations subject to corrosive or flammable gases
- Locations subject to dust, salts, iron dust, or oil smoke
- Locations subject to shock or vibration
- Locations subject to exposure of water, oil, or chemicals
- Locations where strong magnetic or electric fields are generated
- For properly using the product
CAUTION
Failure to follow these instructions may lead to death or serious injury.
WARNING
Failure to follow these instructions may lead to injury.
CAUTION
Failure to follow these instructions may lead to product damage (product malfunction, etc.). Provides additional information on proper operation.
- UL certification The N-R2 complies with the following UL/CSA standards and has obtained the UL/C-UL certification.
- Applicable standards
- UL File No.
- UL category
UL508, UL60950-1 E207185, E167973 NRAQ/NRAQ7, NWGQ2/NWGQ8
Be sure to observe the following installation and environment conditions. TIPS
Indicates useful information or information that aids understanding of text descriptions.
- Pollution degree 2
- Overvoltage category I
For Safely Using the Product
Caution - Do not connect directly to the branch circuit. This product must be supplied power by a suitable, approved isolated transformer or power supply not exceeding 200 VA max.
- General precautions
- FCC regulations
- At startup and during operation, be sure to check that the
The N-R2 complies with the following FCC EMI regulations.
functions and performance of the N-R2 is operating properly.
- FCC Part 15 Subpart B, Class B digital device
- We recommend that you take substantial safety measures to
avoid any damage in the event a problem occurs.
- Canada IC (Industry Canada) regulations
- If the N-R2 is modified or used in any way other than described in
The N-R2 complies with the following IC EMI regulations.
the specifications, its function and performance cannot be guaranteed.
- ICES-003, Class B digital apparatus
- When the N-R2 is used in combination with other instruments, the
- CE marking
function and performance may be effected by operating conditions and the surrounding environment.
The N-R2 complies with the following essential requirements of the EU Directive.
- Do not use the N-R2 for the purpose of protecting the human
body.
- EMC Directive (2004/108/EC)
- The information contained in this manual is subject to change
without notice.
The following harmonized standards are applied to this product in order to confirm the compliance.
- Notice
- Applicable standards (EMI)
When this product is used under the circumstances and operating environments described below, adhere to the limitations of the ratings, take adequate measures to ensure safety such as fail-safe installations and consult a KEYENCE sales representative.
- Applicable standards (EMS)
EN55011, Class A EN55022, Class B EN61000-6-2 EN61000-6-1
- The length of the communication and power cables should be less than 30 m.
- For use under circumstances or environments which are not
described in the manual
Package Contents List
- For use with nuclear power control, railway, aircraft, vehicles,
incinerators, medical equipment, entertainment equipment, safety devices etc.
Main unit
Instruction manual
- For use in applications where death or serious property damage is
possible and extensive safety precautions are required.
- For properly using the product
CAUTION
- Do not use the N-R2 in an environment subject to flammable, explosive, or corrosive gases.
- Be sure that all screws are tightened securely.
- Use crimp contacts of the specified size for wiring.
- The N-R2 uses a 24 VDC power supply. Using a power supply outside this range or an AC power supply may cause product failure.
- Do not disassemble or modify the N-R2. This may cause product failure.
111DANGERNote
Foreign Regulations and Standards
- Do not use the N-R2 in an environment subject to flammable, explosive, or corrosive gases.
- Be sure that all screws are tightened securely.
- Use crimp contacts of the specified size for wiring.
- The N-R2 uses a 24 VDC power supply. Using a power supply outside this range or an AC power supply may cause product failure.
- Do not disassemble or modify the N-R2. This may cause product failure.
E N-R2-IME N-R2-IME N-R2-IM
Page2of 4
Open in the PDF
The text of page 2, from the PDF itself
Part Names and Functions
CAUTION 1. Head port
Install and remove connection cables with the power disconnected.
„ Connecting the power supply
2. Power LED
Connect the 24 VDC power supply to the power terminal of the N-R2.
3. Communication status LED
4. RS-232C port
5. I/O status LED 6. I/O terminals Twist pair cable
7. Power terminal
Power supply 24V+10% -20%
8. DIN rail mounting tab Number
Name1Head port
Used to connect the head.
Function2Power LED
Lights when the power is ON.
CAUTION
Communication status Monitors the status of communication with the head. LED
3 4
RS-232C port
Used to connect to the host (personal computer, PLC).
5
I/O status LED
Monitors the ON/OFF status of I/O terminals.
6
I/O terminals
Used to connect I/O signal lines of control units.
7
Power terminal
Terminal for 24 VDC power supply input.
8
DIN rail mounting tab
The dimensions of crimp contacts used for wiring should be as follows:
A tab for mounting the DIN rail.
System Configuration Figure
Head port
Using a power supply other than 24 VDC may cause product failure.
Personal computer
Terminal Round Terminal Y terminal
Dimensions a: 6 mm Max. a: 6 mm Max.
Item Wire size Tightening torque Wire material Wire type Electric wire temperature rating
Description AWG14-22 0.49 N·m (4.34 lbf·in) Copper Stranded wire +60°C max.
„ Layout and wiring of the I/O terminal block
- Layout of the I/O terminal block
Head BL Series SR Series PLC KV -B1 6X
C
RS-232C port I/O terminal block
Timing sensorOUT1 to 4IN1Note
- For connection, use stranded copper wire having a gage of AWG16 to 26 and temperature rating of 60°C or higher.
- The tightening torque is 0.19 N·m (1.7 lbf·in).
Connection and Wiring Methods
- Wiring IN1 and IN2
„ Connecting the code reader
Circuit diagram
Connect the code reader to the head port of the N-R2. Pin layout of the head port Name
Signal name1Signal direction431OUT1OUT1 inputInput9872OUT2OUT2 inputInput12113RXDRS-232C ReceiveInput4RTSRS-232C ReceivableOutput5OUT4OUT4 inputInput6IN2IN2 outputOutput2 6 10IN1, IN2Pin number5Round 12-pin jackE N-R2-IM7TXDRS-232C TransmitOutput8CTSRS-232C TransmittableInput9OUT3OUT3 inputInput10IN1IN1 outputOutput11+5V+5V power supplyOutput12GND(SD)Common GND-Internal circuit INCOM2
Page3of 4
Open in the PDF
The text of page 3, from the PDF itself
- Wiring OUT1 to 4
50 mm or more on the top and bottom; no space is required on the right and left sides
Internal circuitOUT1 to 4Load Load Load Load
80 mm or more from the front
50 mm Load OUT COM
80 mm Circuit diagram
Wiring the RS-232C port
- Pin layout of the RS-232C port 1 2 3 4 5
50 mm
D-sub 9-pin (male) DTE specification (terminal definition) #4-40 screw (female)
Installation precautions
- When installing the N-R2, do not block the ventilation slots on the top
6 7 8 9 Pin numberSymbolDescription2RD (RXD)Data receptionInput3SD (TXD)Data transmissionOutput4ER (DTR)
Connected to Pin 6 internally
Output5SG6DR (DSR)
Connected to Pin 4 internally
Input7RS (RTS)
Transmission request (always ON)
Output8CS (CTS)Transmission permittedInput
and bottom of the unit. Otherwise, heat builds up inside the unit, causing product failure.
- If the temperature of the N-R2 will foreseeable exceed the upper limit of the operating temperature (50C), take the appropriate measures such as performing forced air cooling or ensuring proper ventilation so that the temperature does not exceed the upper limit of the normal operating temperature (50C).
Signal direction
Signal ground
Installing and removing the N-R2 to and from the DIN rail
- Installing the N-R2 to the DIN rail
1 Lower the mounting tab on the back of the N-R2.
- Wiring the RS-232C cable
Check that the mounting tab is placed in the position shown in the following diagram.
When connecting to the PC, wire as shown below. DOS/V PC
N-R2Connector caseConnector caseRD22RDSD33SDRS77RSCS88CSER44ERDR66DRSG55SG
D-sub 9-pin (female) #4-40 screw
D-sub 9-pin (female) #4-40 screw
Mounting tab
2 Install the N-R2 to the DIN rail as shown in the following
- It can be connected with Keyence’s optional cable OP-27937 (2 m).
diagram. Protrusion
Installing the N-R2 Surrounding space
- Install the N-R2 vertically.
Top
DIN rail
When the installation direction changes, provide adequate surrounding space so that heat does not build up.
- For ventilation, maintain a space of 50mm or
more from the top and bottom of the N-R2. As long as the N-R2 is the only source of heat generation, the N-R2 can be installed without space on the right and left sides. Provide a space of 80 mm or more in front of the N-R2 to connect the BL head.
Installing the N-R2 to the DIN rail 1. Hook
BottomMounting tabProtrusionDIN rail2. Push3E N-R2-IM
Page4of 4
Open in the PDF
The text of page 4, from the PDF itself
Dimensions diagram
- Removing the N-R2 from the DIN rail
1 Lower the mounting tab as shown in B in the following
44.2 41.8
45
diagram, and then remove the N-R2.
122.335.828.340 RAB
Lower with a screw driver or another tool. 4.2
Mounting tab
(128.5)
2 After the N-R2 is removed, return the mounting tab to the
Warranties and Disclaimers
state shown in A.
(1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1) year from the date of shipment. If any models or samples were shown to Buyer, such models or samples were used merely to illustrate the general type and quality of the Products and not to represent that the Products would necessarily conform to said models or samples. Any Products found to be defective must be shipped to KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection and examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or repair or replace at no charge any Products found to be defective. This warranty does not apply to any defects resulting from any action of Buyer, including but not limited to improper installation, improper interfacing, improper repair, unauthorized modification, misapplication and mishandling, such as exposure to excessive current, heat, coldness, moisture, vibration or outdoors air. Components which wear are not warranted. (2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are only suggestions, and it is Buyer's responsibility to ascertain the fitness of the Products for Buyer’s intended use. KEYENCE will not be responsible for any damages that may result from the use of the Products. (3) The Products and any samples ("Products/Samples") supplied to Buyer are not to be used internally in humans, for human transportation, as safety devices or fail-safe systems, unless their written specifications state otherwise. Should any Products/ Samples be used in such a manner or misused in any way, KEYENCE assumes no responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE harmless from any liability or damage whatsoever arising out of any misuse of the Products/Samples. (4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER. In some jurisdictions, some of the foregoing warranty disclaimers or damage limitations may not apply.
Specifications General specifications Model
N-R2
Power supply for the code reader
5 VDC±5% (650 mA) 9 LEDs (power supply status, data transmission/ reception status, I/O terminal status)
Rating
Environment resistance
Display Operating surrounding air temperature
0 to 50C
Storage ambient temperature
-20 to 60C
Operating ambient humidity
35 to 85%RH (no condensation)
Operating atmosphere
No dust or corrosive gases present
Vibration resistance
10 to 55 Hz, complex amplitude 1.5 mm, 2 hours in each of X, Y, and Z directions
Power voltage24 VDC (+10%, -20%)Consumption current380 mA or lessMassApprox. 135 g
I/O specifications Number of pins
2 (IN1 and IN2)Input format InputTerminal block Output
Bidirectional voltage input
Input maximum rating26.4 VDCMinimum ON voltage15 VDCMaximum OFF current1 mANumber of pins4 (OUT1 to 4)Output formatPhoto MOS relay outputOutput rating load30 VDC, 100 mAOFF time leak current0.1 mA or less
ON time residual voltage
BUYER'S TRANSFER OBLIGATIONS: If the Products/Samples purchased by Buyer are to be resold or delivered to a third party, Buyer must provide such third party with a copy of this document, all specifications, manuals, catalogs, leaflets and written information provided to Buyer pertaining to the Products/Samples. E 1101-3
1 V or less
KEYENCE CORPORATION
Communication specifications Connector Communication standards Head interface
Host interface
Communication rate
1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan www.keyence.com PHONE: +81-6-6379-2211
1 (12-pin round connector) RS-232C compliant 4800, 9600, 19200, 31250, 38400, 57600, 115200 bit/s
AUSTRIA Ph: +43 22 36-3782 66-0
HONG KONG Ph: +852-3104-1010
NETHERLANDS Ph: +31 40 20 66 100
THAILAND Ph: +66-2-369-2777
BELGIUM Ph: +32 1 528 1222
HUNGARY Ph: +36 1 802 73 60
POLAND Ph: +48 71 36861 60
UK & IRELAND Ph: +44-1908-696900
BRAZIL Ph: +55-11-3045-4011
INDIA Ph: +91-44-4963-0900
ROMANIA Ph: +40 269-232-808
USA Ph: +1-201-930-0100 VIETNAM Ph: +84-4-3772-5555
Data bit length7/8 bitsParity checkNone/even/oddStop bit length1/2 bitsFlow control
Hardware/software/none selectable
Connector
1 (D-sub 9-pin connector)
CANADA Ph: +1-905-366-7655
INDONESIA Ph: +62-21-2966-0120
SINGAPORE Ph: +65-6392-1011
RS-232C compliant
CHINA Ph: +86-21-3357-1001
ITALY Ph: +39-02-6688220
SLOVAKIA Ph: +421 2 5939 6461
CZECH REPUBLIC Ph: +420 222 191 483
KOREA Ph: +82-31-789-4300
SLOVENIA Ph: +386 1-4701-666
FRANCE Ph: +33 1 56 37 78 00
MALAYSIA Ph: +60-3-7883-2211
SWITZERLAND Ph: +41 43-45577 30
GERMANY Ph: +49 6102 36 89-0
MEXICO Ph: +52-55-8850-0100
TAIWAN Ph: +886-2-2721-8080
Communication standards Total extended length
15 m or less (including the head cable)
Specifications are subject to change without notice. Copyright (c) 2015 KEYENCE CORPORATION. All rights reserved.
E N-R2-IM
4
13455E 1027-2 96M13455 Printed in Japan
A6WW1-MAN-1086