Page 1 of Expandable Safety Light Curtains PJ-V Series

Spec sheet · Keyence

Expandable Safety Light Curtains PJ-V Series

Spec sheet9 pagesPDF 445 KB

Catalog pages for the Keyence PJ-V series expandable safety light curtains, including the PJ-V90 main controller.

Download the PDF445 KB

Covers · 1 model

The models it covers

Summary

What is in it

Keyence catalog pages for the PJ-V series expandable safety light curtains. They describe the features (expandable sensor heads with 20 mm optical axis pitch, LED bar alignment, sub-controller for two heads, compact DIN rail safety controller), typical applications, a selection chart of base and expansion units by detection zone, and specifications for sensor heads, the PJ-V90 main controller, the PJ-V91 sub-controller and connector cables, plus wiring and dimensions.

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Keyence catalog pages for the PJ-V Series expandable safety light curtains: the PJ-V20, PJ-V21 and PJ-V22 sensor head units, the PJ-V90 main controller and the PJ-V91 sub-controller. They give specifications, functions such as lockout and self-diagnosis, controller connections, the safety standards listed, usage hints and dimensions.

Device
PJ-V90: main controller for the PJ-V safety light curtain, used with one sensor head p. 2
Power
Controller: 24 V DC ±10%, 20 W max. including the sensor head p. 3
Current draw
PJ-V90+PJ-V20: 350 mA; PJ-V21: 25 mA; PJ-V22: 15 mA p. 3
Response time
15 ms max. (ON to OFF), including sensor head response time p. 3
Outputs
Controller: FSD1, FSD2 and SSD outputs plus AUX; three safety relays p. 1, 3
Controller enclosure
IP-20; mount inside a control panel rated IP-54 or higher p. 3
Mounting
Controller mounts on a DIN rail p. 1
Relay life
Mechanical: 10 million operations or more; electrical: 100,000 operations or more p. 3
Protection
Power supply section: reversed polarity protection and surge absorber p. 3
Ambient temperature
-10 to +55°C p. 3
Sensor heads
PJ-V20/V21/V22: 140 to 1260 mm zone, 8 to 64 axes at 20 mm pitch, 7 m range, infrared LED 880 nm, IP-65 p. 3
Sensor head units
PJ-V20 base unit (8 axes), PJ-V21 expansion unit A (8 axes), PJ-V22 expansion unit B (4 axes) p. 2
Accessories
Test piece OP-31608, release tool OP-31609, bracket OP-31784, intermediate support OP-31785, end cap OP-31786, relay board unit OP-31788 p. 6, 8

What this sheet walks you through

  • Combining base and expansion units for a detection zone p. 2
  • Reading the bar LED indicator p. 4
  • Lockout, fail-safe and self-diagnostic functions p. 4, 5
  • Using the PJ-V91 sub-controller for two sensor heads p. 5
  • Controller wiring connections p. 6
  • Risk level assessment and safety category selection p. 7
  • Adding and removing sensor head units p. 7
  • Extending the transmitter and receiver cables p. 8
  • Replacing the controller output relays p. 8
  • Sensor head and controller dimensions p. 8, 9

Good to know

  • The spec sheet states Category 4 ESPE according to EN954-1 (type 4 AOPD according to IEC61496). p. 3
  • The system does not operate unless an end cap or expansion unit B closes the sensor head. p. 7
  • Up to 64 optical axes can be used; more causes a failure. p. 7
  • The LOCKOUT input terminals come shorted with a bar that must be removed to use the input. p. 8

Questions this sheet answers

What is the Keyence PJ-V90?

The main controller of the PJ-V expandable safety light curtain, used with one sensor head; a PJ-V91 sub-controller adds a second. p. 2

What power does the PJ-V90 need?

24 V DC ±10%, with up to 20 W including the sensor head. p. 3

How long can the PJ-V sensor cables be?

The transmitter and receiver cables can each be extended up to 21 m, not counting the 50 cm cable on the base unit. p. 2

What is the PJ-V response time?

15 ms maximum from ON to OFF, including the sensor head response time. p. 3

Can the PJ-V90 output relays be replaced?

Yes, by swapping in the separately sold relay board unit OP-31788 with the power off. p. 8

The whole text · 1 part

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 91-9

The file

Size and text

PublisherKeyence
Pages9
PDF445 KB
TextText from the PDF itself.

The first pages · 4 of 9

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 9
Page 2
Page 2of 9
Page 3
Page 3of 9
Page 4
Page 4of 9