A two-page Mean Well specification sheet for the D-50 series dual output switching power supply, printed for models D-50A and D-50B. It does not name the D-50AGD. It gives the input range, output regulation, protection, environment, dimensions and terminal layout.
- Device type
- Dual output switching power supply, D-50 series (D-50A, D-50B) p. 1
- AC input
- 85 ~ 132VAC or 170 ~ 264VAC, selected by switch; 47 ~ 63Hz p. 1
- Terminals
- AC/L, AC/N, FG, DC output +V1, DC output +V2, DC output COM p. 2
- Overload protection
- 105 ~ 150% rated output power; fold back current limiting, recovers automatically p. 1
- Efficiency
- 73% typical p. 1
- Dimensions, weight
- 159*97*38mm (L*W*H), 0.53Kg p. 1
- Working temperature
- -10 ~ +60, per the output load derating curve; 20 ~ 90% RH non-condensing p. 1
- CH1 adjust range
- CH1: 4.75 ~ 5.5V p. 1
- Setup, rise, hold
- 200ms, 100ms, 20ms at full load p. 1
- AC current, inrush
- 1.3A/115VAC, 0.65A/230VAC; cold start inrush 18A/115VAC, 36A/230VAC p. 1
- Withstand voltage
- I/P-O/P 1.5KVAC, I/P-FG 1.5KVAC, O/P-FG 0.5KVAC p. 1
- Cooling, switching
- Free air convection; fixed switching frequency 24KHz p. 1
- MTBF
- 408.9K hrs min., MIL-HDBK-217F p. 1
- Case
- Case No. 901 (dimensions in mm) p. 2
What this sheet walks you through
- Connecting the AC input and the DC output terminals p. 2
- Checking load derating against ambient temperature p. 2
- Mounting dimensions of the case p. 2
Good to know
- Parameters not stated otherwise are measured at 230VAC input and rated load. p. 1
- The output load must follow the derating curve at higher ambient temperatures. p. 1, 2
- The AC input range is chosen with a switch. p. 1
Questions this sheet answers
What input voltage does the Mean Well D-50 power supply take?
85 ~ 132VAC or 170 ~ 264VAC, chosen with a switch, at 47 ~ 63Hz. p. 1
How big is the Mean Well D-50 series power supply?
159*97*38mm (L*W*H), weighing 0.53Kg. p. 1
What does the D-50 do on overload?
It folds back the current from 105 ~ 150% of rated output power and recovers by itself once the fault is removed. p. 1
Does the Mean Well D-50 need a fan?
The sheet states cooling by free air convection. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
D - 5 0 series
50W Dual Output Switching Power Supply Features : AC input selectable by switch Protections:Short circuit/Over load Cooling by free air convection 100% full load burn-in test
Fixed switching frequency at 24KHz I/P-O/P:Rated 1 year warranty
SPECIFICATION MODELOUTPUTINPUTD-50AD-50BDC VOLTAGE5V12V5VRATED CURRENT6A2A6A1ACURRENT RANGE1 ~ 6A0.3 ~ 2A1 ~ 6A0.2 ~ 1ARATED POWER54W 100mVp-p50mVp-p100mVp-p 8.0%54W
RIPPLE & NOISE (max.) Note.2 50mVp-p VOLTAGE ADJ. RANGE
CH1 : 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0%
+5,-8%CH1 : 4.75 ~ 5.5V 2.0%LINE REGULATION0.5%1.0%0.5%1.0%LOAD REGULATION0.5%5.0%0.5%8.0%SETUP, RISE, HOLD TIME
200ms, 100ms, 20ms at full load
VOLTAGE RANGE
85 ~ 132VAC/170 ~ 264VAC selected by switch
FREQUENCY RANGE47 ~ 63HzEFFICIENCY(Typ.)73%
AC CURRENT INRUSH CURRENT(max.)
1.3A/115VAC 0.65A/230VAC COLD START 18A/115VAC 36A/230VAC
LEAKAGE CURRENT PROTECTION OVER LOAD WORKING TEMP.
240 ~ 370VDC 73%
<0.5mA / 240VAC 105 ~ 150% rated output power Protection type : Fold back current limiting, recovers automatically after fault condition is removed -10 ~ +60
(Refer to output load derating curve)
WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY
20 ~ 90% RH non-condensing
TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC
0.03%/ (0 ~ 50 ) on +5V output 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes Design refer to UL1012 I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
OTHERS-20 ~ +85, 10 ~ 95% RH
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Design refer to FCC Part15 J Conduction MTBF 408.9K hrs min. MIL-HDBK-217F (25 ) DIMENSION 159*97*38mm (L*W*H) PACKING
NOTE
24V
0.53Kg; 24pcs/13.6Kg/0.75CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
File Name:D-50-SPEC 2004-06-30
http://store.iiic.cc/
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
D - 5 0 series
50W Dual Output Switching Power Supply Mechanical Specification
Case No. 901Unit:mm3.57152.51384.548.252 -M697659.52373 .5 4.5 7824159 15022383.5M328.53 .53-1818.5996.5117
Terminal Pin. No Assignment Pin No. 1 2 3
Assignment AC/L AC/N FG
Pin No. 4 5,6
Assignment DC OUTPUT +V2 DC OUTPUT COM
7DC OUTPUT +V1Output Derating
Static Characteristics (B) Ta=25 D-50B
80LOAD (%)60300+5VOUTPUT VOLTAGE (V)1005.2D-50A4020245.0250+24V 234.8200224.6150214.4100204.2194.0+24V50OUTPUT RIPPLE (mVp-p)2525+5V -10 -100 010203040AMBIENT TEMPERATURE (5060
(VERTICAL) (HORIZONTAL)
)60 12085 17090 18095 100 190 200105 210110 220115 230120 240125 250130 260INPUT VOLTAGE (V) 60Hz
File Name:D-50-SPEC 2004-06-30