Page 1 of Migatron RPS-100 Ultrasonic Sensor Spec Sheet

Spec sheet · Migatron

Migatron RPS-100 Ultrasonic Sensor Spec Sheet

Spec sheet2 pagesPDF 177 KB

Both pages are below, each with its text.

Download the PDF177 KB

Filed with · 1 model

Also filed with these models on the old site

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

A two-page Migatron data sheet (1997) for the RPS-100 ultrasonic sensor with a remote transducer and separate controller, part numbers RPS-100-14, RPS-100-72 and RPS-100-240, plus their -500 analog ranging versions. The RPS-100TR-72 designation itself is not printed. It gives the ranges, power, outputs, response times and weights, and shows wiring and mounting figures.

What it is
Ultrasonic proximity and ranging sensor with remote transducer and controller p. 1
Sensing ranges
Adjustable 2" to 14", 5" to 72" or 10" to 240" p. 2
Power input
120VAC, 15 - 24VDC, 12VDC regulated or 12 - 17VAC; only 120VAC or 24VDC with 500 analog card p. 2
Relay output
Isolated Form C relay, N.O. and N.C., .5 Amp maximum at 120VAC; 12VDC logic signal p. 2
Analog option
RPS-500 card: 0 - 10VDC and 4 - 20 mA, with zero, span, sample and hold controls p. 1, 2
Ambient temperature
0ºC to 60ºC (32ºF to 140ºF) p. 2
Input current
30 Milliamps; 50 Milliamps with 500 card p. 2
Transducer frequency
38.5kHz p. 1, 2
Response time
5" to 72" range: 100mS on, 100mS off p. 2
Weights
Controller 34.2 ounces; transducer 2.2 ounces p. 2
Included
Mounting flanges, LED indicator, ranging potentiometer, 6-ft. transducer cable p. 1
Ordering the analog version
Add -500 to the part number, as in RPS-100-14-500 p. 1

What this sheet walks you through

  • Setting the detection range with the Range Control potentiometer p. 1
  • Proximity detection versus ranging measurement p. 1
  • Wiring diagrams for the RPS-100 and RPS-500 p. 2
  • Angle of tilt, beam spread and mounting dimensions p. 2

Good to know

  • With the 500 analog card the power input is 120VAC or 24VDC only. p. 2
  • A mounting dimension grows from 2.5" to 3.75" with the 500 analog ranging card. p. 2

Questions this sheet answers

What power does the Migatron RPS-100 take?

120VAC, 15 - 24VDC, 12VDC regulated or 12 - 17VAC. With the 500 analog card, only 120VAC or 24VDC. p. 2

How do I get a 4-20 mA output from an RPS-100?

Add the RPS-500 card, ordered by adding -500 to the part number; it gives 0-10 VDC and 4-20 mA. p. 1

How is the RPS-100 detection range set?

With the Range Control potentiometer on the front cover of the controller. p. 1

What can the RPS-100 relay switch?

Its isolated Form C relay gives N.O. and N.C. contacts rated .5 Amp maximum at 120VAC. p. 2

The file

Size and text

Pages2
PDF177 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Migatron RPS-100 Ultrasonic Sensor Spec Sheet

The text of page 1, from the PDF itself

RPS-100 Features Various Sensing Ranges

Remote TransducerBroad Sensing BeamRPS-500 Compatible

Low Frequency - 38.5kHz

3-Way Power Operation

LED Indicator

Isolated Form C Relay Output

Small Transducer Head

Small Electronic Controller

The RPS-100 is the first of the RPS series and has a proven track record of reliability. Since its introduction in 1979, the RPS-100 has proven itself in versatility and ease of operation. The remote transducer allows for mounting of the sensor head in cramped spaces while the controller is out of the way. The ranging and proximity modes provide the versatility of simple detection, or actual distance measuring. The isolated form C relay furnishes N.O. and N.C. outputs, and with the addition of the RPS-500 card various analog outputs are supplied. The RPS100 sensor, which operates at a frequency of 38.5kHz,

2"

Adjustable Turn-Off Pt.

has a broad sensing beam which allows for detection of an object at greater angles of tilt. Sensing ranges available for the RPS-100 include 2" to 14", 5" to 72", and 10" to 240". Mounting flanges, LED indicator, ranging potentiometer, and 6-ft. transducer cable are included. Optional cable lengths are available.

14"Proximity DetectionRanging MeasurementProximity DetectionRanging Measurement

Proximity detection is the detection of an object in a given range. The detection range of the RPS-100 is controlled by the "Range Control" potentiometer located on the front cover of the controller. Any object within the desired range is detected, while objects out of range are ignored. The detect point is independent of size, material, and reflectivity.

With the addition of the RPS-500 card, Analog outputs of 0-10 VDC and 4-20 mA are provided. Precise distances of an object moving to and from the transducer are measured via time intervals between transmitted and reflected bursts of ultrasonic sound. The example shows a target detected at 6 inches from the transducer and moving to 10 inches. The distance change is continuously calculated and outputted. Ranging Option is indicated by following the part number with (-500). (Example: RPS-100-14-500)

Migatron Corporation - 1997

100B -7-

Page 2 of Migatron RPS-100 Ultrasonic Sensor Spec Sheet

The text of page 2, from the PDF itself

Specifications: Operational Range:

Adjustable 2" to 14" Adjustable 5" to 72" Adjustable 10" to 240"

Power Input:

  • Only 120VAC or 24VDC

120VAC 15 - 24VDC 12VDC Regulated 12 - 17VAC

with 500 Analog card.

Input Current: 30 Milliamps Input Current with 500 card: 50 Milliamps Ambient Temperature:

0ºC to 60ºC or 32ºF to 140ºF

Controller: Transducer: Transducer Housing:

Metal Enclosed Aluminum Plastic

Output
Isolated Form C Relay .5 Amp Maximum at 120VAC 12VDC Logic Signal 0 - 10VDC, 4 - 20 mA Analog Outputs with Zero, Span, Sample, and Hold controls.

N.O., N.C.

Output with 500 card: Transducer Frequency:

38.5kHz

Response Time
2" to 14" 30mS - On 30mS - Off

Weight of Controller: Weight of Transducer:

34.2 ounces 2.2 ounces

Fig. A

5" to 72" 100mS - On 100mS - Off

10" to 240" 250mS - On 250mS - Off

Fig. B

110 VAC COM COM 110 VAC

  • 24 VDC GND IN 4 - 20 mA 0 - 10 v GND OUT ENABLE GND OUT GND
  • 12 XMIT 1ST DET.

NEAR DISTANCE DISPLAY FAR

Fig. C

SAMPLE & HOLD SPAN ZERO INVERTING SWITCH

Figure
Fig. D

*

A - Angle of Tilt B - Beam Spread C - Wiring Diag.- For RPS-100 D - Wiring Diag.- For RPS-500 E - Mounting Dimensions * Dimension changes from 2.5" to

Fig. E

3.75" when ordered with the 500 Analog Ranging card.

PART NUMBERRANGEOUTPUT

RPS-100-14 RPS-100-72 RPS-100-240

2" - 14" 5" - 72" 10" - 240"

Isolated form C Relay Isolated form C Relay Isolated form C Relay

RPS-100-14-500 RPS-100-72-500 RPS-100-240-500

2" - 14" 5" - 72" 10" - 240"

0 - 10VDC and 4 - 20mA Analog 0 - 10VDC and 4 - 20mA Analog 0 - 10VDC and 4 - 20mA Analog

(815) 338-5800 / FAX: (815) 338-5803

Migatron Corp.

935 Dieckman Rd., Woodstock, Il. 60098 USA http://www.migatron.com e-mail: info@migatron.com

-8-