Spec sheet · Minarik
Minarik XP Series PWM DC Drives Spec Sheet
Spec sheet1 pagePDF 192 KB
The page is below, with its text.
What this file really is
The old site listed this file as a spec sheet for the Minarik 170-0533. The sheet lists XP drives by their own model numbers; 170-0533 is not among them.
Filed with · 1 model
Also filed with these models on the old site
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A one-page Minarik catalog sheet for the XP Series PWM DC motor speed drives, 1/100 to 1 HP, in chassis and NEMA 1 versions. It covers C1XP01-115AC-A, C1XP03-115AC-A, XP02-115AC, XP02-115AC-Q, XP05-115AC, XP10-115AC, PCMXP02-115AC, PCMXP05-115AC and PCMXP10-115AC, and does not name 170-0533. It gives ratings, adjustments, options, accessories and heights.
- Device type
- XP Series PWM DC motor speed drives for OEM use, 1/100 to 1 HP p. 1
- Input, output
- 115 VAC input, 0-130 VDC output on every listed model p. 1
- Small models
- C1XP01-115AC-A: 1 ADC, 1/100 - 1/10 HP; XP02-115AC, XP02-115AC-Q, PCMXP02-115AC: 2 ADC, 1/20 - 1/8 HP; C1XP03-115AC-A: 3 ADC, 1/10 - 1/4 HP p. 1
- Larger models
- XP05-115AC, PCMXP05-115AC: 5 ADC, 1/4 - 1/2 HP; XP10-115AC, PCMXP10-115AC: 10 ADC, 1/2 - 1 HP p. 1
- Enclosure
- C1XP: compact NEMA 1 enclosure; XP and PCMXP: chassis p. 1
- PCMXP isolation
- PCMXP: isolated, follows a remote 0-10VDC signal from a PLC p. 1
- Speed regulation
- 1% regulation over 80:1 speed range p. 1
- DC input
- Accepts AC or DC input, including 100-160VDC p. 1
- Adjustment pots
- IR compensation, max speed, current limit; min speed (PCMXP and C1XP only); accel/decel (XP only); signal adjust (PCMXP only) p. 1
- -Q option
- XP02-115AC-Q: adds terminal block, on-board fusing and inhibit; min speed trimpot replaces accel/decel p. 1
- Accessories
- Heatsink 223-0159; DLC600 digital closed loop controller p. 1
- Heights
- XP02-115AC 1.77 in [45 mm]; XP05-115AC 2.36 in [60 mm]; XP10-115AC 2.88 in [73 mm] p. 1
- Terminals
- Spade terminals; chassis drives have the industry standard MM footprint p. 1
What this sheet walks you through
- Choosing an XP drive by input, output current and horsepower p. 1
- Setting the calibration pots for IR compensation, speed, current limit and acceleration p. 1
- Running a PCMXP drive from a PLC 0-10VDC signal p. 1
- Fitting the drive: board outline and heights p. 1
Good to know
- Heatsink 223-0159 must be used when the output is above 5 Amps. p. 1
- The XP family of drives has no field supply. p. 1
- For a PWM regenerative drive that can reverse on-the-fly, the sheet refers to the NRG-4Q Series. p. 1
Questions this sheet answers
What horsepower is the Minarik XP05-115AC?
The XP05-115AC is rated 5 ADC and 1/4 - 1/2 HP, with 115 VAC in and 0-130 VDC out. p. 1
Can a Minarik XP drive take a 0-10V signal from a PLC?
The PCMXP models are isolated and can follow a remote 0-10VDC from a PLC. p. 1
When does an XP drive need heatsink 223-0159?
Heatsink 223-0159 must be used when the output is above 5 Amps. p. 1
What does the -Q option on the XP02-115AC add?
A terminal block, on-board fusing and inhibit, and a min speed trimpot in place of the accel/decel trimpot. p. 1
The file
Size and text
Every page · 1
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 1
Open in the PDF
The text of page 1, from the PDF itself
1/100 to 1 HP
PWM DC Chassis, NEMA 1 Input Voltage (VAC)
Output Voltage (VDC)
Max Current (ADC)
HP Rating @ 90/130 VDC Output
HP Rating @ 180 VDC Output
EnclosureC1XP01-115AC-A1150-13011/100 - 1/10–NEMA 1–––1.05YES–YESXP02-115AC1150-13021/20 - 1/8–Chassis*****–****1.05YES––XP02-115AC-Q1150-13021/20 - 1/8–Chassis*****–****1.05––––1.05YES––DriveReversingIsolationField Supply (VDC)Form FactorULCULCEBUL R®PCMXP02-115AC1150-13021/20 - 1/8–Chassis*****0-10 VDCC1XP03-115AC-A1150-13031/10 - 1/4–NEMA 1–––1.05YES–YESXP05-115AC1150-13051/4 - 1/2–Chassis*****–****1.05YES–––1.05YES––PCMXP05-115AC1150-13051/4 - 1/2–Chassis*****0-10 VDCXP10-115AC1150-13010*1/2 - 1–Chassis*****–****1.05YES––PCMXP10-115AC1150-13010*1/2 - 1–Chassis*****0-10 VDC–1.05YES––
* Heatsink number 223-0159 must be used when the output is above 5 Amps. **** A field supply is not available on the XP family of Drives. Minarik Drives recommends using the XL Series (pg 14). ***** See NRG-4Q Series (page 27) for a PWM Regenerative drive that can reverse on-the-fly.
XPxx-115AC DIMENSIONS Specifically designed for the original equipment manufacture (OEM), the XP Series of DC motor speed drives provide high performance at a low cost. These drives are well suited for MMXL or XL drive applications who do not need all of their features. These PWM drives result in a smooth, quiet, cool and low maintenance motor operation.
4.30 [109]R502R504AA+ + DC IN +
CURRENT LIMIT ACCEL / DECEL
3.58 [91]0.19 [5] 6 PLACESC501 R5011.75 [44]
The C1XP Series is enclosed in a compact NEMA 1 enclosure. The PCMXP Series includes isolation so the drive can follow a remote 0-10VDC from a PLC.
- DC IN L
S1WS2HS3
Choose the XP Series for the best low cost PWM drive on the market.
R503IR COMP0.74 [19]
See page 50 for an in-depth comparison of the different models of drives.
MAX SPEEDHEIGHT XP02-115AC1.77 [45]XP05-115AC2.36 [60]XP10-115AC2.88 [73]
All dimensions in inches [millimeters]
Dimensions of drives not shown above can be found on page 56 and 57. Wiring diagrams of chassis drives can be found on pages 61, 62 and 68.
FEATURES
- MM footprint: Chassis drives have an industry standard footprint.
C1XP01-115AC-A C1XP03-115AC-A
XP02-115AC-Q
PCMXP02-115AC PCMXP05-115AC PCMXP10-115AC
XP02-115AC XP05-115AC XP10-115AC
- Low cost: Designed for OEM applications.
- Speed range and regulation: 1% regulation over 80:1 speed range.
- User adjustable calibration pots: IR compensation, max speed, min speed (PCMXP and C1XP only), current limit, acceleration/deceleration (XP drives only), and signal adjust (PCMXP only).
- Spade terminals: Easy to use, lower cost, and able to fit in a smaller package.
- Accepts AC or DC input: Can accept 100-160VDC input voltage or 70130VAC.
- Options: “-Q” option on the XP02-115AC adds a terminal block, on-board fusing, inhibit, and replaces the accel/decel trimpot with a min speed trimpot.
- Accessories: Heatsink 223-0159, DLC600 digital closed loop controller.
- XP SERIES Call us toll free 1.800.MINARIK or find more information online at www.minarikdrives.com