The text of a manual · part 8 of 11
FX Family MELSEC PLC Technical Catalogue: FX series, pages 63 to 72
Pages 63 to 72 of 85, from FX Family MELSEC PLC Technical Catalogue
The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Mitsubishi FX1S-14MR-ES/UL
Page 63
Farbprofil: Deaktiviert Komposit Standardbildschirm
TERMINAL LAYOUTS EXTENSION UNITS ///
왎 Modular Extension Units MELSEC FX2N FX2N-16EX-ES/UL
+V0
FX2N-8EYT-ESS/UL S/S
X2
X5
X2
X4
X7 X6
X3
X1
COM Y1 Y3 Y0 Y2
X2
X0
X1
X6
X7
X4
X4
X5
X2
X2
X3 X6
X5
S/S
FX2N-8ER-ES/UL
X0
X1 X3
X3
X1 X0
X7
X0
X7
ES
1 2 3 4 5 6 7
S/S
FX2N-8EX-ES/UL FX2N-8EX-UA1/UL
X6
X7
IN 0
COM2 Y5 Y7 Y6 Y4
X4 X5
X4
X6
FX2N -16EX
Y7 Y6
Y4
Y3 COM1 Y1 Y0 Y2
FX2N-8EYR-ES/UL
Y5
+V1
Y2
X3
X2 X3 X5
POWER
X0
X0 X1
X1
1 2 3 4 5 6 7
Y3
Y1 Y0
S/S
IN 0
FX2N-16EYT-ESS/UL +V0
Y2 Y3
Y2 Y3
Y4
Y4
Y5
Y5
Y6
Y6
Y7
Y7
Y0
Y0
Y1
FX2N -16EYT
Y4 Y6
Y4
Y2
Y7
Y6
Y5
Y5
Y3
Y3
Y7
+V1
1 2 3 4 5 6 7
Y2
Y1 OUT 0
+V1
FX2N-16EYR-ES/UL
TERMINALS & DIMENSIONS
POWER
Y0
Y0 Y1
Y1
1 2 3 4 5 6 7
+V0
OUT 0
FX2N-16EYS-ES/UL COM1 Y0 Y1 Y2 Y3 Y5
POWER
Y4
Y2
COM2
Y6 COM2 Y7
Y6 Y7
Y5
Y4
Y4
Y5
Y3
Y3
Y2
COM2
Y1
Y7
Y0
Y4
1 2 3 4 5 6 7
Y6 COM2 Y7
Y6
Y7
Y1 OUT 0
Y5
Y4
Y6
Y2
FX2N -16EYS
Y3
Y5
Y2
Y4
Y0
Y1
1 2 3 4 5 6 7
Y3
Y2 Y3
Y7
Y0
Y1
Y0 Y1
Y6
Y7
Y0
COM1
Y5
Y6
Y7
OUT 0
1 2 3 4 5 6 7
POWER
Y6
FX2N -16EYR
OUT 0
Y4 Y0 Y2 Y5 COM1 Y1 Y3
1 2 3 4 5 6 7
Y4 Y0 Y2 Y5 COM1 Y1 Y3
OUT 0
왎 Extension Adapter Boards MELSEC FX1N
S/S BX0 BX1 BX2 BX3
• BY0+ BY0- BY1+ BY1-
•
FX1N-2EYT-BD
S/S
FX1N-4EX-BD
BX1 BX2 BX3
BY0+ BY0- BY1+ BY1-
BX0
63
MITSUBISHI ELECTRIC FX1-Cat 2006 Euro GB45-66.prn FX1-Cat 2006 Euro GB Donnerstag, 20. April 2006 20:33:12
63
Page 64
Farbprofil: Deaktiviert Komposit Standardbildschirm
TERMINAL LAYOUTS SPECIAL FUNCTION MODULES ///
왎 Special Function Adapters MELSEC FX3U
FX3U-4HSX-ADP
FX3U-2HSY-ADP
10-polig
X0/3+ X0/3X1/4+ X1/4X2/5+ X2/5X6/7+ X6/7SG SG
10-polig
TERMINALS & DIMENSIONS
FX3U-4AD-ADP
Y0/2+ Y0/2Y4/6+ Y4/6SGA Y1/3+ Y1/3Y5/7+ Y5/7SGB
FX3U-4DA-ADP
10 poles
5 poles
FX3U-4AD-PT-ADP
FX3U-4AD-TC-ADP
24+ 24-
24+ 24–
24+ 24–
V1+ I1+ COM1 V2+ I2+ COM2 V3+
V1+ I1+ COM1 V2+ I2+ COM2 V3+
L1+ L1– I1– L2+ L2– I2– L3+
10 poles
I3+ COM3 V4+ I4+ COM4
5 poles
FX3U-232-ADP
10 poles
I3+ COM3 V4+ I4+ COM4
5 poles
L3– I3– L4+ L4– I4–
24+ 24–
10 poles
5 poles
J-type J-type J-type J-type L1+ L1– L2+ L2– L3– L3– L4+ I4–
FX3U-485-ADP
5 4 3 2 1
9 8 7 6
1 2 3 4 5 6 7 8 9
CD(DCD) RD(RXD) SD(TXD) ER(DTR) SG(GND) DR(DSR) • • •
5 poles
64
FX1-Cat 2006 Euro GB45-66.prn FX1-Cat 2006 Euro GB Donnerstag, 20. April 2006 20:33:33
RDA RDB SDA SDB SG
Terminal resistance setting switch
330 Ω OPEN 110 Ω
MITSUBISHI ELECTRIC 64
Page 65
Farbprofil: Deaktiviert Komposit Standardbildschirm
/// TERMINAL LAYOUTS SPECIAL FUNCTION MODULES
왎 Analog Modules MELSEC FX2N
FX2N-2AD
V IN2 I IN2 COM2 V IN1 I IN1 COM1
FX2N-2DA
VOUT2 IOUT2 COM2 VOUT1 IOUT1 COM1 VOUT2 IOUT2 COM2 VOUT1 IOUT1 COM1
V IN2 I IN2 COM2 V IN1 I IN1 COM1
FX2N-2AD
FX2N-2DA
CH1
OFFSET
CH1
OFFSET
GAIN Ch2
GAIN
OFFSET Ch2
GAIN
FX2N-4AD
FX2N-4DA
24+
24+
V+
CH1 VI-
I+
I+
I+ POWER
V+
CH3
I+ V+ VI-
CH4
V+
I+
I+
FX2N-4DA
VI-
VI-
D/A
I+
FX2N-4AD-TC
I+
I+ VI-
VI-
VI-
24 V
V+
V+
CH4
FG
V+
CH2
I+
A/D
I+
FX2N -4DA FX2N-4AD
VI-
VI-
V+
CH3
VIFG
I+ V+
FG
FX2N -4AD
I+
V+
V+ VI-
VI-
I+
V+
CH2
V+ VIFG
FG
FG
TERMINALS & DIMENSIONS
POWER
24 V
24-
VI-
I+
24+
V+ VI-
V+
CH1
VI-
2424-
V+
24+
24-
I+
FX2N-4AD-PT 24+
24+
24-
I-
CH1
I-
L+
L-
L-
L-
POWER
POWER
I-
CH3
IL+
CH4
FG
I-
L-
L-
L-
L-
FX2N-4AD-PT
L+
L+
FG
L-
A/D
65
MITSUBISHI ELECTRIC FX1-Cat 2006 Euro GB45-66.prn FX1-Cat 2006 Euro GB Donnerstag, 20. April 2006 20:33:55
L-
FG
L+
L+ 24 V
I-
L+
SLD
CH4
L-
CH2
L-
A/D
ILI-
FX2N -4AD-PT FX2N-4AD-TC
L+
LSLD
FG
SLD
CH3
L+
L+
L+
L-
SLD
FX2N -4AD-TC
L+
L-
SLD
CH2
SLD
FG
FG L+
24 V
24-
L+
24+
L+
L-
CH1
SLD
24- SLD
L+
24+
24-
65
Page 66
Farbprofil: Deaktiviert Komposit Standardbildschirm
TERMINAL LAYOUTS SPECIAL FUNCTION MODULES ///
왎 Analog Modules MELSEC FX3U
FX3U-4DA
FX3U-4AD
24+
24+ 24V+
CH1 VI-
VI-
I+
24+
V+ VI-
V+
CH1
VI-
2424-
V+
24+
24-
I+
I+
I+
POWER
POWER
I+ V+
CH3
FG I+ V+ VI-
CH4
I+ V+
FG I+
I+
FX3U-4AD
VI-
VI-
A/D
I+
VI-
VI-
V+
CH4
FG 24 V
V+
CH2
VI-
FX3U-4DA
I+
D/A
V+
V+
FX3U -4AD
VI-
I+ VI-
V+
VI-
24 V
FG
CH3
FX3U -4DA
I+
I+
V+
V+ VI-
VI-
I+
V+
CH2
V+ VI-
FG
FG
I+
왎 Communications Boards MELSEC FX3U FX3U-232-BD
TERMINALS & DIMENSIONS
FX3U-USB-BD
FX3U-422-BD
9 8 7 6
5 4 3 2 1
1 2 3 4 5 6 7 8 9
5 poles
CD(DCD) RD(RXD) SD(TXD) ER(DTR) SG(GND) DR(DSR) • • •
RDA RDB SDA SDB SG
66
FX1-Cat 2006 Euro GB45-66.prn FX1-Cat 2006 Euro GB Donnerstag, 20. April 2006 20:34:35
FX3U-485-BD
Terminal resistance setting switch
330 Ω OPEN 110 Ω
MITSUBISHI ELECTRIC 66
Page 67
Farbprofil: Deaktiviert Komposit Standardbildschirm
/// TERMINAL LAYOUTS SPECIAL FUNCTION MODULES
왎 High Speed Counter and Positioning Modules MELSEC FX1N / FX2N / FX3U
FX2N-1PG-E
FX2N-10PG
POWER ERROR
COM0 RP PG0+ VIN FP PG0-
VIN COM0 FP RP PG0PG0+
FX2N -1PG
FX 2N -10PG
START DOG X0 X1 øA øB
PGO FP RP CLR
1PG POWER
POWER S T D P O O G P G O
CLR STOP DOG COM1 S/S S/S
F R C E P P L R R R
COM1 S/S S/S
CLR STOP DOG
VINFPRPPG0CLRoAoBStart S/S X1
VIN+ FP+ RP+ PG0+ CLR+ oA+ oB+ DOG S/S X0
FX2N-1HC
24+
UP
COM
OUT2 POWER
XP5 YH+
FX2N-1HC
YS-
XP5 YH+ YS+
TCPTB
YS
YH-
COMP YH- YS-
TC+ PTB
YH
XD5 COMD
FG
TCPTB
DIS PRE
B5+ XD24 XP24
PTA
FG
COMP
B-
CT
OUT2
PTA TC+ PTB
XP24
FX2N -1HC FX2N-2LC
CT
CT 24 V OUT1
TCPTB
CT
B5+ XD24 COMD
TC+ PTB
TCPTB
BXD5
FG
FX2N -2LC
FG
A5+ B12+
POWER
PTA
PTA TC+ PTB
A24+
B24+
CT
CT
B
CT
CT
A-
A24+ A5+ B24+
COM
A12+
A
A12+ A- B12+
OUT1
DOWN 24- OUT1 OUT2
24+
24-
TERMINALS & DIMENSIONS
FX2N-2LC
YS+
FX3U-20SSC-H
INT0 INT1 A B
MOT OR- Y START DOG INT0 INT1 A B
X-READY Y-READY X-ERROR Y-ERROR
POWER
X-INT0 NC X-INT1 X-oA+ X-oAX-oB+ X-oBX-DOG S/S X-START
Y-INT0 NC Y-INT1 Y-oA+ Y-oAY-oB+ Y-oBY-DOG S/S Y-START
67
MITSUBISHI ELECTRIC FX1-Cat 2006 Euro GB67-84.prn FX-Cat 2006 Euro GB Freitag, 21. April 2006 12:31:43
67
Page 68
Farbprofil: Deaktiviert Komposit Standardbildschirm
TERMINAL LAYOUTS SPECIAL FUNCTION MODULES ///
왎 Analog Modules MELSEC FX0N / FX2N
FX2N-8AD
V IN 2 I IN 2 COM2 V IN 1 I IN 1 COM1
FX0N-3A
V OUT I OUT COM
24+
24-
V1+ I1+ COM1 V3+ I3+ COM3 V2+ I2+ COM2 V4+ I4+ COM4
V1+ 24+
24-
I1+
V2+
V3+ I3+ COM1 COM3 I2+ COM2 V4+ I4+ COM4
MITSUBISHI FX2N-8AD POWER RUN V6+ V5+
I5+
I8+ COM8 I6+ COM6 V8+ COM5 V7+ I7+ COM7
V6+ I6+ COM6 V8+ I8+ COM8 V5+ I5+ COM5 V7+ I7+ COM7
FX2N-5A
24+
V+
I+
OUT
I+
V+
VI-
24-
24+
24-
POWER
FX2N -5A
I+
I+
IN3
FX2N-5A
V+
V+
IN4
I+
AD/DA
VI-
I+
I+ VI-
VI-
V+
24 V
V+
V+ IN2
TERMINALS & DIMENSIONS
VI-
VI-
I+
I+ VI-
IN1
V+
I+
왎 Analog Adapter Boards MELSEC FX1N
• I+
V1+ I1+ V2+ I2+
VI-
VI-
V1+
FX1N-2AD-BD
•
FX1N-1DA-BD
I1+
•
•
V2+
V+
I2+
I+
V+
VI-
VI-
68
FX1-Cat 2006 Euro GB67-84.prn FX-Cat 2006 Euro GB Freitag, 21. April 2006 12:32:05
MITSUBISHI ELECTRIC 68
Page 69
Farbprofil: Deaktiviert Komposit Standardbildschirm
/// TERMINAL LAYOUTS SPECIAL FUNCTION MODULES
왎 Network Modules MELSEC FX2N 24G 24+ FG
FX0N-32NT-DP
FX2N-32CCL
2424+ FG
24G 24+ FG
24+ 24-
FG
32CCL
POWER
DC
BF
DIA
STATION NO.
RUN
X10 OCCUPY STATION
FX2N-32CCL
X1
0 1st. 1 2st. 2 3st. 3 4st.
POWER
B RATE 0 156K 1 625K 2 2,5M 3 5M 4 10M
LRUN • LERR • RD • SD
LRUN•LERR•RD•SD
DA DB DG DA DB SLD
DA DA
DB
DB SLD DG
FX2N-32DP-IF
FX2N-32DP-IF-D
FX2N-16CCL-M
COM 24+ L
N
24+
2424+ 24-
FG
24+ 24+ FG
RUN ERR. MST TEST 1 TEST 2 L RUN L ERR.
RUN
RUN ERR. MST TEST 1 TEST 2
FX2N-16CCL-M
STATION NO.
L RUN L ERR.
x10
STOP
POWER
POWER x1
COM N
24 +
SLD DG
POWER
DA
RUN
5 6 7
FX2N-32DP-IF
ON
4
DIA
B RATE 0 156K 1 625K 2 2,5M 5M 3 4 10M SW OFF ON 1 2 3 4 CLR HLD 5 6 7 8
3
SW M/S PRM TIME LINE
MODE
1 2
DB
DB
FX2N-16CCL-M
BF
DA
MITSUBISHI
SLD DG
L
SW M/S PRM TIME LINE
E R R O R
8
SD RD
64 32 16 8 4 2 1
SD RD
TERMINALS & DIMENSIONS
ON OFF
FX2N-32CAN
FX2N-32ASI-M ASI+
ASI-
FROM/TO
ASI+ ASI-
U ASI ASI ACTIVE
RUN
ASI+
ASI+ ASI-
ASI-
Tx/Rx ERROR POWER
POWER
FX2N -32CAN
FX2N -32ASI-M FX2N-32ASI-M
PRJ MODE PRG ENABLE FROM/TO CONFIG ERR
FX2N-64DNET
CAN_H Shield
SW1 SW0 DR1 DR0 NA5 NA4 NA3 NA2 NA1 NA0
1 2 3 4 5 6 7 8 9 0
V+
FX 2N -64DNET
FG
POWER
FX2N-64DNET
FG
CAN_L VFROM/TO MS NS
69
MITSUBISHI ELECTRIC FX1-Cat 2006 Euro GB67-84.prn FX-Cat 2006 Euro GB Freitag, 21. April 2006 12:32:35
69
Page 70
Farbprofil: Deaktiviert Komposit Standardbildschirm
TERMINAL LAYOUTS SPECIAL FUNCTION MODULES ///
왎 Network Modules MELSEC FX3U
FX3U-ENET
FX3U-64DP-M
24+
2424+
RUN
24+
TOKEN FROM/TO ERROR POWER
FX3U -64DP-M
왎 Communications Module MELSEC FX2N
FX2N-232IF
24+
24+ 24-
FX 2N -232IF
24-
POWER SD
TERMINALS & DIMENSIONS
RD
FX2N -232IF
왎 Interface Module MELSEC FX2NC
FX2NC-232ADP
FX2NC-485ADP
FX2NC-232ADP
FX2NC-485ADP
POWER
POWER
RD
RD
SD
SD
9 8 7 6
5 4 3 2 1
1 2 3 4 5 6 7 8 9
CD(DCD) RD(RXD) SD(TXD) ER(DTR) SG(GND) DR(DSR) • • •
RDA RDB SDA SDB
SG
RDA RDB SDA SDB Z SG
70
FX1-Cat 2006 Euro GB67-84.prn FX-Cat 2006 Euro GB Freitag, 21. April 2006 12:32:52
MITSUBISHI ELECTRIC 70
Page 71
Farbprofil: Deaktiviert Komposit Standardbildschirm
/// DIMENSIONS ALPHA
Dimensions of the ALPHA series AL2-14M쏔-쏔, AL2-24M쏔-쏔 6,0
4,0
4,0
6,0
(A) (B)
DC INPUT
+
-
(A) (B)
1
2
3
DC INPUT
4
5
6
7
8
9
10
11 12 13 14 15
POWER 24V DC
MITSUBISHI
ESC
+
+
90,0
90,0
MITSUBISHI ESC
-
-
OK
OK
AL2-10MR-D
OUT1
OUT2
OUT3
RELAY OUTPUT OUT
OUT4
4,0
4,0
AL2-24MR-D
5
6
7
8
9
6,0
6,0
71,2
52,0
124,6
AL2-2PT-ADP, AL2-2TC-ADP
AL2-ASI-BD
AL2-4EY쏔, AL2-2DA
24,5
53,1
24,5
53,1
35,5
+
EI1
+
EI2
-
+
ASI+
-
-
POWER 24V DC
ASI+ ASI-
ASI-
V1+
V1-
33,5
V2+
V2-
CH1
CH2
OUTPUT
0~10V
MITSUBISHI
MITSUBISHI
90
90
90
POWER
4EX +
EI3
+
TERMINALS & DIMENSIONS
CH1 CH2 200°C -50°C Line 200°C -50°C Line
AL2-2PT-ADP PT100 -50~200°C
EI4
CH2
CH1
L1-
I1-
L2+
L2-
I2-
4
L1+
Mounting frame AL-FRAME
170
4
94
4
94
104
28
76
170
94
28
76
94
104
All dimensions in mm
71
MITSUBISHI ELECTRIC FX1-Cat 2006 Euro GB67-84.prn FX-Cat 2006 Euro GB Freitag, 21. April 2006 12:33:09
71
Page 72
Farbprofil: Deaktiviert Komposit Standardbildschirm
DIMENSIONS FX1S/FX1N/FX2N BASE UNITS ///
Dimensions of Base Units FX1S
X X-8
S/S
100-240 VAC
L
Z
X1
N
X0
X3
X5
X2
X7
X4
POWER RUN ERROR
FX1S-14MR OUT
0 1 2 3 4 5 24V
COM0
Y1 COM1
Y
Z
60
90
49
FX1S-10MR-ES/UL
60
90
75
FX1S-10MT-DSS
60
90
49
FX1S-14MR-DS
60
90
49
FX1S-14MR-ES/UL
60
90
75
FX1S-14MT-DSS
60
90
49
FX1S-20MR-DS
75
90
49
FX1S-20MR-ES/UL
75
90
75
FX1S-20MT-DSS
75
90
49
FX1S-30MR-DS
100
90
49
FX1S-30MR-ES/UL
100
90
75
FX1S-30MT-DSS
100
90
49
IN
Y-8
Y
MITSUBISHI
Y0
X
FX1S-10MR-DS
X6
0 1 2 3 4 5 6 7
0V
Base unit
Y2 COM2
Y4 Y3
14MR -ES/UL
Y5
2 x ø4,5
Dimensions of Base Units FX1N
X X–8
S/S L
N
X1 X0
X3 X2
X5 X4
X7 X6
X11 X10
Base unit
X13 X12
X15 X14
X17 X16
X21 X20
X23 X22
X25 X24
90
IN
POWER RUN ERROR
FX1N-40M OUT 0 1 2 3 4 5 6 11 12 13 14 15 16 17 0V 24V
Y0 COM0
Y1 COM1
Y2 COM2
Y4 Y3
COM3
Y6 Y5
Y10 Y7
COM4
Y12 Y11
Y14 Y13
COM5
7 10
Y16 Y15
X (in mm)
FX1N-14MR왏왏왏
90
FX1N-14MT왏왏왏
90
X27 X26
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17 20 21 22 23 24 25 26 27
MITSUBISHI
82
TERMINALS & DIMENSIONS
100-240 VAC
75
Y17
40M
FX1N-24MR왏왏왏
90
FX1N-24MT왏왏왏
90
FX1N-40MR왏왏왏
130
FX1N-40MT왏왏왏
130
FX1N-60MR왏왏왏
175
FX1N-60MT왏왏왏
175
2 x ø4,5
Dimensions of Base Units MELSEC FX2N
87
X X -10
L
N
Base unit
COM X0 X2 X4 X6 X10 X12 X14 X16 24+ X1 X3 X5 X7 X11 X13 X15 X17 0 1 2 3 4 5 6 7
X (in mm)
FX2N-16M왏왏왏
130
FX2N-32M왏왏왏
150
FX2N-48M왏왏왏
182
FX2N-64M왏왏왏
220
IN POWER RUN BATT.V
FX2N -32MR
OUT
0 1 2 3 4 5 6 7
PROG-E
10 11 12 13 14 15 16 17
CPU-E
35
90
10 11 12 13 14 15 16 17
FX2N-80M왏왏왏
285
FX2N-128M왏왏왏
350
Y0 Y2 Y4 Y6 Y10 Y12 Y14 Y16 COM1 Y1 Y3 COM2 Y5 Y7 COM3 Y11 Y13 COM4 Y15 Y17
ø4,5
72
FX1-Cat 2006 Euro GB67-84.prn FX-Cat 2006 Euro GB Freitag, 21. April 2006 12:33:26
MITSUBISHI ELECTRIC 72