Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Super Line J Series Three Phase Induction Motor

Spec sheet · Mitsubishi

Super Line J Series Three Phase Induction Motor

Spec sheet12 pagesPDF 5.3 MB

Specification sheet for Mitsubishi Super Line J Series three phase induction motors (SF-JR, SF-JRV, SF-J, SB-JR) from 1/4 HP to 125 HP.

Download the PDF5.3 MB

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

Mitsubishi Electric catalog of the Super Line J Series three phase induction motors, made in steel plate and cast iron frames from 63M to 250M. It explains the type designations (horizontal, vertical V and flange F types) and degrees of protection IP22, IP44 and IP55, lists standard specifications, gives full load current and speed tables for 2, 4 and 6-pole motors at 50 and 60 Hz, and shows dimension drawings and tables for each frame and mounting type.

From the sheet · read page by page

Key facts from this sheet

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

Spec sheet for the Mitsubishi Super Line J series three phase induction motors, 1/4 HP to 125 HP, covering the SF-JR, SF-JRV, SF-JRF, SF-J, SF-JV, SF-JF, SB-JR and SB-JRV types. It gives standard specifications, full load current and speed tables, dimension drawings with weights, and connection diagrams. The designation SF-JVR, under which the site files it, does not appear in the document.

Device
Super Line J series three phase induction motors, 1/4 HP to 125 HP p. 2
Voltage and frequency
LT, 10HP and below: 220/380 to 415V 50Hz, 220/440V 60Hz; HT, 5HP and above: 380 to 415V 50Hz, 380 to 440V 60Hz p. 3
IP55 fan-cooled types
SF-JR, SF-JRV, SF-JRF (63M to 132M); SF-J, SF-JV, SF-JF (160M to 180L); SF-J (200L to 250M) p. 3, 11
IP44 and IP22 types
IP44 totally enclosed fan-cooled: SF-JR 63M to 90L; IP22 drip-proof: SB-JR and SB-JRV 80M to 132M p. 3, 6, 7, 8
Type designation
R = steel frame (blank = cast iron); V = vertical, F = flange (blank = foot mounting); enclosure F = totally enclosed fan-cooled, B = drip-proof, E = totally enclosed p. 2
Frame material
63M to 132M steel plate; 160M to 250M cast iron p. 3
Insulation class
IP22 and IP44: Class B for 90L and below, Class F for 100L and above; IP55: Class F on all models p. 3
Connection
6 leads; terminal block on IP55 63M to 132M and IP22 100L to 132M, lead wires on the other frames p. 2, 3
Power transmission
Direct-coupled or belt driven up to 10HP 2-pole and on all 4-pole and 6-pole motors; 2-pole 15HP and above direct-coupled only p. 3
Direction of rotation
Counter-clockwise viewed from the shaft end p. 3
Humidity and altitude
85% RH or less (drip-proof), 95% RH or less (totally enclosed); less than 1,000m above sea level p. 3
IP55 sealing
Glue seal between frame and brackets, rubber gasket on the terminal box, cable gland, grease at the bearing housings, end cover and water fringer p. 2
Conformed standards
The spec sheet states IEC 60034-1 and JIS C 4210 (horizontal type), JEC-2137-2000 (vertical type) p. 3
Coating color
Munsell N5.5 (gray) p. 3

What this sheet walks you through

  • Reading the type designation and IP protection codes p. 2
  • Full load current and speed by output and supply voltage, LT and HT p. 4, 5
  • Dimensions, bearings and weights of SB-JR horizontal drip-proof motors p. 6
  • Dimensions, bearings and weights of SB-JRV vertical drip-proof motors p. 7
  • Dimensions, bearings and weights of SF-JR IP44 motors p. 8
  • Dimensions, bearings and weights of SF-JR IP55 motors p. 9
  • Dimensions, bearings and weights of SF-J 160M to 250M motors p. 10
  • Dimensions, bearings and weights of SF-JRV and SF-JV vertical motors p. 11
  • Connection diagrams for low voltage, high voltage and star-delta starting p. 12

Good to know

  • The HT connection can be used only with motors of 5HP and above. p. 12
  • 2-pole motors of 15HP and above are for direct coupling only. p. 3
  • The installation must be free of bursting or erosive gas or vapor. p. 3
  • The standard vertical-type motor can be used for an indoor flange type. p. 3
  • Shaft center height has a tolerance of -0.5 mm. p. 6

Questions this sheet answers

What voltages do Mitsubishi Super Line J motors run on?

LT motors (10HP and below) take 220/380 to 415V 50Hz or 220/440V 60Hz; HT motors (5HP and above) take 380 to 415V 50Hz or 380 to 440V 60Hz. p. 3

What do the R and V mean in SF-JRV?

R means a steel frame (no letter means cast iron) and V means the vertical type. p. 2

Can a 2-pole Super Line J motor be belt driven?

Yes up to 10HP; 2-pole motors of 15HP and above are for direct coupling only. p. 3

Which way does the motor turn?

Counter-clockwise, viewed from the shaft end. p. 3

What insulation class are the IP55 motors?

Class F on all IP55 models. p. 3

The whole text · 2 parts

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6
  2. Pages 7 to 127-12

The file

Size and text

PublisherMitsubishi Electric Automation (Thailand) Co., Ltd.
Pages12
PDF5.3 MB
TextThe pages are scans; their text was read by OCR, which may hold reading errors.

The first pages · 4 of 12

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 12
Page 2
Page 2of 12
Page 3
Page 3of 12
Page 4
Page 4of 12