Spec sheet · Mitsubishi
Super Line J Series Three Phase Induction Motor
Spec sheet12 pagesPDF 5.3 MB
Specification sheet for Mitsubishi Super Line J Series three phase induction motors (SF-JR, SF-JRV, SF-J, SB-JR) from 1/4 HP to 125 HP.
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
Mitsubishi Electric catalog of the Super Line J Series three phase induction motors, made in steel plate and cast iron frames from 63M to 250M. It explains the type designations (horizontal, vertical V and flange F types) and degrees of protection IP22, IP44 and IP55, lists standard specifications, gives full load current and speed tables for 2, 4 and 6-pole motors at 50 and 60 Hz, and shows dimension drawings and tables for each frame and mounting type.
From the sheet · read page by page
Key facts from this sheet
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
Spec sheet for the Mitsubishi Super Line J series three phase induction motors, 1/4 HP to 125 HP, covering the SF-JR, SF-JRV, SF-JRF, SF-J, SF-JV, SF-JF, SB-JR and SB-JRV types. It gives standard specifications, full load current and speed tables, dimension drawings with weights, and connection diagrams. The designation SF-JVR, under which the site files it, does not appear in the document.
- Device
- Super Line J series three phase induction motors, 1/4 HP to 125 HP p. 2
- Voltage and frequency
- LT, 10HP and below: 220/380 to 415V 50Hz, 220/440V 60Hz; HT, 5HP and above: 380 to 415V 50Hz, 380 to 440V 60Hz p. 3
- IP55 fan-cooled types
- SF-JR, SF-JRV, SF-JRF (63M to 132M); SF-J, SF-JV, SF-JF (160M to 180L); SF-J (200L to 250M) p. 3, 11
- IP44 and IP22 types
- IP44 totally enclosed fan-cooled: SF-JR 63M to 90L; IP22 drip-proof: SB-JR and SB-JRV 80M to 132M p. 3, 6, 7, 8
- Type designation
- R = steel frame (blank = cast iron); V = vertical, F = flange (blank = foot mounting); enclosure F = totally enclosed fan-cooled, B = drip-proof, E = totally enclosed p. 2
- Frame material
- 63M to 132M steel plate; 160M to 250M cast iron p. 3
- Insulation class
- IP22 and IP44: Class B for 90L and below, Class F for 100L and above; IP55: Class F on all models p. 3
- Connection
- 6 leads; terminal block on IP55 63M to 132M and IP22 100L to 132M, lead wires on the other frames p. 2, 3
- Power transmission
- Direct-coupled or belt driven up to 10HP 2-pole and on all 4-pole and 6-pole motors; 2-pole 15HP and above direct-coupled only p. 3
- Direction of rotation
- Counter-clockwise viewed from the shaft end p. 3
- Humidity and altitude
- 85% RH or less (drip-proof), 95% RH or less (totally enclosed); less than 1,000m above sea level p. 3
- IP55 sealing
- Glue seal between frame and brackets, rubber gasket on the terminal box, cable gland, grease at the bearing housings, end cover and water fringer p. 2
- Conformed standards
- The spec sheet states IEC 60034-1 and JIS C 4210 (horizontal type), JEC-2137-2000 (vertical type) p. 3
- Coating color
- Munsell N5.5 (gray) p. 3
What this sheet walks you through
- Reading the type designation and IP protection codes p. 2
- Full load current and speed by output and supply voltage, LT and HT p. 4, 5
- Dimensions, bearings and weights of SB-JR horizontal drip-proof motors p. 6
- Dimensions, bearings and weights of SB-JRV vertical drip-proof motors p. 7
- Dimensions, bearings and weights of SF-JR IP44 motors p. 8
- Dimensions, bearings and weights of SF-JR IP55 motors p. 9
- Dimensions, bearings and weights of SF-J 160M to 250M motors p. 10
- Dimensions, bearings and weights of SF-JRV and SF-JV vertical motors p. 11
- Connection diagrams for low voltage, high voltage and star-delta starting p. 12
Good to know
- The HT connection can be used only with motors of 5HP and above. p. 12
- 2-pole motors of 15HP and above are for direct coupling only. p. 3
- The installation must be free of bursting or erosive gas or vapor. p. 3
- The standard vertical-type motor can be used for an indoor flange type. p. 3
- Shaft center height has a tolerance of -0.5 mm. p. 6
Questions this sheet answers
What voltages do Mitsubishi Super Line J motors run on?
LT motors (10HP and below) take 220/380 to 415V 50Hz or 220/440V 60Hz; HT motors (5HP and above) take 380 to 415V 50Hz or 380 to 440V 60Hz. p. 3
What do the R and V mean in SF-JRV?
R means a steel frame (no letter means cast iron) and V means the vertical type. p. 2
Can a 2-pole Super Line J motor be belt driven?
Yes up to 10HP; 2-pole motors of 15HP and above are for direct coupling only. p. 3
Which way does the motor turn?
Counter-clockwise, viewed from the shaft end. p. 3
What insulation class are the IP55 motors?
Class F on all IP55 models. p. 3
The whole text · 2 parts
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file