Spec sheet · MSC
MSC BK Mikro LIN Spec Sheet
Spec sheet4 pagesPDF 552 KB
All 4 pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Spec sheet for the MSC BK MIKRO LIN.B tool monitoring system, which checks tools, cavities and bore holes by linear scanning with a 50 mm or 100 mm stroke scanner. It describes the Multi and Single control units, the TK50-LIN.B and TK100-LIN.B scanners, how monitoring works, and the technical data.
- Device
- Tool monitoring system for linear scanning, with scanners of 50 mm or 100 mm maximum stroke and Multi or Single control units p. 1
- Power supply
- 230 VAC, 120 VAC or 24 VDC depending on model; 6 VA max p. 4
- Relay outputs
- 2 relays (O.K. and K.O.), 250 VAC / 30 VDC, 2 A max; 500 VA / 60 W max, 10 mA min at 10 V p. 4
- Inputs
- Galvanically isolated, about 5 mA, 6 ms min pulse; 24 VDC control voltage p. 4
- Scanners
- TK50-LIN.B (50 mm max stroke) and TK100-LIN.B (100 mm max stroke) p. 3
- Control unit size
- 40 x 75 x 107.5 mm (WxHxD), on 35 mm sectional rail to DIN EN 50022 p. 4
- Control unit housing
- Insulating material, protection class II, IP 20; climate class 3K3 under EN 50178 p. 4
- Scanner housing
- Anodized aluminum, IP 64, M12x1 6-pin connector, exchangeable M3x6 tip p. 3
- Scanning cycles
- More than 5 million at minimum scanning intensity p. 3
- Temperatures
- Scanner 0°C to +80°C, control unit 0°C to +50°C; storage -25°C to +80°C p. 3, 4
- Connection cable
- 6-wire PUR cable, 5 m, extendable to approximately 25 m; DIN 45322 circular connector at the control unit p. 2
- Multi control unit
- Multi only: 8 coded scanning positions and monitoring of a freely selectable range p. 1
- Other features
- Two scanning intensity steps, relay contacts selectable as NCC or NOC, O.K. and K.O. LEDs, cable break detection p. 2
What this sheet walks you through
- How a linear scanning cycle works p. 2
- Position monitoring and area monitoring in teach mode p. 1, 2
- Scanner dimensions for the 50 mm and 100 mm models p. 3
- Control unit terminals for Multi and Single p. 4
- Comparing the Multi and Single control units p. 4
Good to know
- The control unit's Scanner switch must be set to 50 or 100 to match the scanner stroke for correct monitoring. p. 3
- An error is reported if the wand hits an object in front of or behind the taught position, or completes the stroke without stopping. p. 2
- Range monitoring (object or free space) is available only on the Multi control unit. p. 1
Questions this sheet answers
What stroke do the BK Mikro LIN scanners have?
The TK50-LIN.B has a 50 mm maximum stroke and the TK100-LIN.B a 100 mm maximum stroke. p. 3
What power does the BK Mikro LIN control unit need?
230 VAC, 120 VAC or 24 VDC depending on the model, with 6 VA max consumption. p. 4
How long can the scanner cable be?
The cable is 5 m long and can be extended to approximately 25 m with extension cables. p. 2
What is the difference between the Multi and Single control units?
The Multi can code 8 scanning positions and monitor a freely selectable range for object or free space monitoring; range monitoring is only for the Multi. p. 1
How does the BK Mikro LIN report a result to the machine?
The control unit passes the scanning result to the machine control via relay contacts, and shows it on O.K. and K.O. LEDs. p. 2
The file
Size and text
Every page · 4
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 4
Open in the PDF
The text of page 1, from the PDF itself
BK MIKRO LIN.B
Control Unit Single
Tool Monitoring System for Linear Scanning – Scanners with maximum Stroke of 50 mm or 100 mm – This system monitors geometries which require longitudinal scanning, especially in cases where rotary scanning is inappropriate or impossible, for example cavities, bore holes, limited space arrangements or critical coolant pressure. The two control units "Multi" and "Single" have different features of monitoring:
Com Start Teach S1S2S324 V DC
- Monitoring of the scanning position whose precise location has been previously entered by "Teach-in", e.g. to carry out a tool check before each working cycle (tool monitoring). Especially for "Multi", 8 scanning positions can be coded.
- Monitoring a scanning range freely selectable via two adjusting switches, e.g. to check cavities with varying depth (object monitoring) or to check bore holes (free space monitoring), only for "Multi". For installing the scanner no aids are necessary.
0%P1 75%0%P2BK MIKRO LIN25%25%Scanner 50%50%1 2 ok: Obj.Home10050k.o.o.k.AC IN L1NControl Unit Multi
Page2of 4
Open in the PDF
The text of page 2, from the PDF itself
BK MIKRO LIN.B
Operating Mode The wand of the scanner scans tools, objects or critical process spaces free of potential, in line with machine cycles. A control unit equipped with a micro-computer triggers the movement of the wand upon an external signal and passes the scanning result to the machine control via relay contacts. The galvanically isolated inputs and outputs guarantee a high degree of operational safety and protection against interferences. Further Features
- Different variants for the tip of the wand are available (also project-specific)
- Two steps for scanning intensity
- Output relay contacts selectable as NCC or NOC
- Various ranges of tolerance for "O.K." message
- Indication of the scanning result by two LEDs for "O.K." and "K.O." at the control unit
- Detection of cable breaks Connection Cable
- 6-wire PUR-cable
- Small circular connector to DIN 45322 at the control unit end
- Molded plug at the scanner end
- Length 5 m, can be extended to a maximum length of approximately 25 m with extension cables Longitudinal Scanning After each starting pulse, the wand travels towards the control position in linear motion with a stroke of up to 50 mm or up to 100 mm. An error is present, if the wand impinges on an object either in front or behind the position stored during “teach-in” or if the wand has completed the stroke without stopping.
Position Monitoring monitoring range vS
Area Monitoring P2v1 vmaxobjectlearned positionmonitoring range vSP1v1vmax zero positionobjectzero position
Example: Tool monitoring in teach mode Vmax V1 Vs P1 P2
= max. speed of scanner = max. speed in forward direction = speed of scanner preset by "scanning intensity" toggle switch = start position = end position
vS(low) < vS(high) < v1 < vmax
Rev. 3.00 dated 18.10.2006
Page 2 of 4
Page3of 4
Open in the PDF
The text of page 3, from the PDF itself
BK MIKRO LIN.B
Scanner Technical Data Housing
Anodized aluminumProtection typeIP 64Scanning tip
Exchangeable, thread M3x6
Connection
Small circular connector M12x1, 6 pin
Ambient temperature0°C to +80°CStorage temperature-25°C to +80Scanning cycles
> 5 million at minimum scanning intensity
Scanner TK50-LIN.B "50 mm maximum stroke" Requirement for correct monitoring: "Scanner" switch at control unit set to "50" ! 154 ø 32
1750Stop position49 ø 20ø4max. stroke73
(tip exchangeable, M3x6)
Housing Connection cable
ROBKROBKROBKROBK83.5 max. 145Scanning wand(angled connector)Connector 4127.5(straight)
General tolerances ISO 2768 – mK
Connection cable (connector at the control unit end)
Scanner TK100-LIN.B "100 mm maximum stroke" Requirement for correct monitoring: "Scanner" switch at control unit set to "100" ! 100
17 Stop position254 ø 3299 ø 20ø4max. stroke123
(tip exchangeable, M3x6)
Housing Connection cable
ROBKROBKROBKROBK83.5 max. 111Scanning wand(straight connector)27.5Connector 41(angled)
Connection cable (connector at the control unit end)
Page 3 of 4
General tolerances ISO 2768 – mK
Rev. 3.00 dated 18.10.2006
Page4of 4
Open in the PDF
The text of page 4, from the PDF itself
BK MIKRO LIN.B
Control Unit Technical Data Housing / protection type
Insulating material housing, protection class II, built-in unit, IP 20
Dimensions (WxHxD)40 x 75 x 107.5 mmCase mountings
Sectional rail, 35 mm, to DIN EN 50022
Power supply voltage
230 VAC, 120 VAC, 24 VDC (depending on model)
Power consumption6 VA max.Control voltage
24 VDC (internal/external)
Inputs
Galvanically isolated, Input current 5 mA approx., Pulse duration 6 ms min.
Switched outputs
2 x 250 VAC / 30 VDC, 2 A max.
Making/breaking capacity
500 VA / 60 W (max.) – 10 mA min. at 10 V
Operational life of relay
5 x 107 switching cycles
Connections
Plug-in screw terminals for connecting – power supply, control inputs, selection inputs (only for "Multi"), relay outputs Scanner socket to DIN 45322, 6 pin
Climatological conditions
Classification 3K3 under EN 50178
Ambient temperature0°C to +50°CStorage temperature-25°C to +80°C
Control Unit: BK MIKRO LIN.B Multi
BK MIKRO LIN.B Single Control inputs
Control inputs Power supply and Control voltage 24 VDC
Power supply and Control voltage 24 VDC
Selection inputsCom Start Teach S1S2+ –S3
These terminals must be connected!
Com Start Lern24 V DC0%BK MIKRO LIN 25%Scanner 50%
Scanner connection 1 2 ok: Obj.
Scanner connectionHome10050k.o. k.o.o.k.o.k.AC IN L1 NAC IN L1Scanner 100P2 25%50%500%P1 75%BK MIKRO LINEAR24 V DCN
Power "K.O.""O.K."supply Relay Relay 230 VAC or These terminals must not be connected! 120 VAC
Power "K.O." "O.K." supply relay relay 230 VAC or These terminals must not be connected ! 120 VAC
Characteristics Features (due to the different control units) Number of toggle switches Ranges of tolerance for "O.K." (referred to the learned position) "O.K." message at "Object" Rotary switches P1, P2 Selection inputs S1, S2, S3 Teach-Mode: Tool monitoring / Object monitoring Number of learned positions, that can be stored Monitoring of a preset range: Switch mode Object monitoring: "O.K.", if an object is detected. Free space monitoring: "O.K.", if no object is detected.
"Multi" 6 4 X X X P1=0, P2=0 8
"Single" 4 2 – – – Standard 1 P1 0, P2 0 – S1=0 – S1=1 – © Copyright MSC Tuttlingen GmbH, Tuttlingen, 2006 Subject to change without notice. Issue 3.00
MSC Tuttlingen GmbH · Rudolf-Diesel-Straße 17 · 78532 Tuttlingen Tel. +49 7461 925 276 · Fax +49 7461 925 268 · E-Mail sales-tut@msc.de · www.msc-tuttlingen.de