Spec sheet · Namco
Namco LPR Spec Sheet
Spec sheet2 pagesPDF 80 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Two-page Namco catalog sheet for the LPR (low profile rotatable) Cylindicator weld field immune proximity sensors, in the LPR 3000 (3,000 PSI) and LPR 5000 (5,000 PSI) versions. It lists part numbers by probe length, connector and output type, and gives common sensor characteristics, LED functions, connector wiring and dimensional drawings.
- Device
- Cylindicator proximity sensor for end-of-stroke indication on hydraulic and pneumatic cylinders p. 1
- Pressure rating
- LPR 3000: 3,000 PSI; LPR 5000: 5,000 PSI p. 1
- Outputs
- 2-wire, 20-230V AC/DC, or 3-wire, 10-30V DC sourcing (PNP); normally open p. 1
- Connectors
- 3-pin Micro, 3-pin Mini, 4-pin Mini or 4-pin Euro, N.O. p. 1
- Leakage current
- 3-wire DC: 10µA; 2-wire AC/DC: 1.7mA or 4.5mA p. 1
- Short circuit protection
- Latching SCP standard; non-latching available in DC models p. 1
- Noise immunity
- Immune to weld fields and electrical noise p. 1
- Ambient temperature
- -4°F to +158°F p. 2
- Switching
- 16Hz maximum; hysteresis 3-10%; repeatability <±1.25% p. 2
- Reverse polarity
- Reverse polarity protected p. 2
- Probe lengths
- 1.025, 1.250, 1.500, 1.750, 2.062, 2.875, 3.775 and 4.560 (unit not printed) p. 1
- Mounting
- Two 1/4"-20 x 5/8" socket head cap screws supplied p. 2
- Shipping weight
- 12 oz. p. 2
What this sheet walks you through
- Choosing an LPR 3000 or LPR 5000 part number by probe length, connector and output p. 1
- Reading the LED indications, including short circuit mode p. 2
- Wiring Euro, Micro and Mini connector models p. 2
- Dimensions and mounting p. 2
Good to know
- Normally closed and DC sinking versions are not listed; the sheet says to consult the factory. p. 1
- If the sensor is shorted, both LEDs flash and the sensor limits current to about 2.0mA. p. 2
Questions this sheet answers
What pressure ratings does the Namco LPR come in?
3,000 PSI (LPR 3000) and 5,000 PSI (LPR 5000). p. 1
What voltage does the Namco LPR Cylindicator run on?
2-wire models run on 20-230V AC/DC; 3-wire models run on 10-30V DC with a sourcing (PNP) output. p. 1
What happens when the Namco LPR output is shorted?
Short circuit protection activates: both LEDs flash and the current is limited to about 2.0mA. p. 2
Is there a normally closed Namco LPR?
The sheet lists only N.O. models and says to consult the factory for normally closed availability. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Proximity Sensors
® Weld LPR Cylindicator Field Immune Sensors
- Both 3,000 and 5,000 PSI Pressure Ratings
- Weld Field and Electrical Noise Immunity
- Standard Latching Short Circuit Protection (SCP), Non-latching Avialable in DC Models
- Predictable, Consistent Electrical Performance
- 100% Tested and Burned-in
- Purpose-Designed Housings and Materials
DC AC/DC For over 25 years, the Cylindicator sensor has been the standard for industrial applications that require endof-stroke indication on Hydraulic and Pneumatic Cylinders. Available in both 3,000 and 5,000 PSI pressure ratings, they are the standard for many OEM cylinder manufacturers. All Cylindicators are completely PLC compatible with many output configurations, including a UL Listed Intrinsically Safe version (see EE931 series for details).
LPR 3000 (3,000 PSI) 3-pin Micro, N.O. Probe Length
3-pin Mini, N.O.
2-wire, 20-230V, AC/DC 2-wire, 20-230V, AC/DC Latching SCP Latching SCP 1.7mA leakage current 1.7mA leakage current 4.5mA leakage current
4-pin Mini, N.O.
4-pin Euro, N.O.
3-wire, 10-30V DC, Sourcing (PNP) 10µA leakage current Latching SCP Non-Latching SCP
3-wire, 10-30V DC Sourcing (PNP) 10µA leakage current Latching SCP Non-Latching SCP
1.025EE230EE230-10423EE230EE230-10420EE260EE260-10420EE210EE210-10440EE210EE210-10400EE210EE210-10444EE210EE210-104041.250EE230-11323EE230-11320EE260-11320EE210-11340EE210-11300EE210-11344EE210-113041.500EE230-12323EE230-12320EE260-12320EE210-12340EE210-12300EE210-12344EE210-123041.750EE230-13323EE230-13320EE260-13320EE210-13340EE210-13300EE210-13344EE210-133042.062EE230-18723EE230-18720EE260-18720EE210-18740EE210-18700EE210-18744EE210-187042.875EE230-17823EE230-17820EE260-17820EE210-17840EE210-17800EE210-17844EE210-178043.775EE230-19023EE230-19020EE260-19020EE210-19040EE210-19000EE210-19044EE210-190044.560EE230-18623EE230-18620EE260-18620EE210-18640EE210-18600EE210-18644EE210-18604
LPR 5000 (5,000 PSI) 3-pin Micro, N.O. Probe Length
3-pin Mini, N.O.
2-wire, 20-230V, AC/DC 2-wire, 20-230V, AC/DC Latching SCP Latching SCP 1.7mA leakage current 1.7mA leakage current 4.5mA leakage current
4-pin Mini, N.O.
4-pin Euro, N.O.
3-wire, 10-30V DC, Sourcing (PNP) 10µA leakage current Latching SCP Non-Latching SCP
3-wire, 10-30V DC Sourcing (PNP) 10µA leakage current Latching SCP Non-Latching SCP
1.025EE230EE230-10427EE230EE230-10425EE260EE260-10425EE210EE210-10445EE210EE210-10405EE210EE210-10446EE210EE210-104061.250EE230-11327EE230-11325EE260-11325EE210-11345EE210-11305EE210-11346EE210-113061.500EE230-12327EE230-12325EE260-12325EE210-12345EE210-12305EE210-12346EE210-123061.750EE230-13327EE230-13325EE260-13325EE210-13345EE210-13305EE210-13346EE210-133062.062EE230-18727EE230-18725EE260-18725EE210-18745EE210-18705EE210-18746EE210-187062.875EE230-17827EE230-17825EE260-17825EE210-17845EE210-17805EE210-17846EE210-178063.775EE230-19027EE230-19025EE260-19025EE210-19045EE210-19005EE210-19046EE210-190064.560EE230-18627EE230-18625EE260-18625EE210-18645EE210-18605EE210-18646EE210-18606d byecte Prot▲
Consult factory for Normally Closed and DC Sinking model availability.
the
am rogr ent P m e c a Repl ime Lifet
Namco Controls Corporation • Mayfield Village, OH 44143 • (440) 460-1360 • Fax: (440) 460-3800
76
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
Common Sensor Characteristics CYLINDICATOR® SENSORS
LOW PROFILE ROTATABLECurrent ConsumptionDC 0.080"Top View1.7 or 4.5mA10µA≈10 VAC2.0V@100mA
Voltage Drop Temperature Drift (Max.)
±10%
Short Circuit Protection
yes
Reverse Polarity Protected
yes
Ambient Temperature Range
-4°F to +158°F1.55" (MINI) (39.4)1.37" (34.8)
Maximum Switching Frequency
16HzHysteresis3-10%Repeatability<±1.25%
Designed to meet NEMA Enclosure Type
Side View0.90" (22.5)0.47" (12.0)
ED “L” DESIGNATES PROBE LENGTH
(2) 1/4"- 20 X 5/8" (15.68) SOC HD CAP SCREWS SUPPLIED
Mini connector shown4, 6, 12 & 13Load Current
5mA to 500mA 200mA max.
LED Indicator
red = power green = power green = target amber = target
Shipping Weight12 oz.Proximity Sensors
AC/DC Nominal Sensing Range (±10%)
DC, AC/DCDimensional DrawingsCircuit Drawings
See Cylindicator® Sensor Design Guide Section for details.
EURO CONNECTOR MODELSMale view shown3 Wire DC N.O.
LED Functions 10-30V DC Green Amber
RedGreenPower OffOffOffOffOff
Power On Load De-energized
OnOffOnOff
Power On Load Energized
OnOn*SCP Mode ActivatedBoth Flashing21(+ DC)34N.O. LOAD20-230V AC/DCOff(- DC)MICRO CONNECTOR MODELSMale view shown2 Wire AC/DC N.O.OnMicro 2-Wire AC N.O.Both Flashing1
*Short Circuit Protection: If the sensor is shorted, the sensor’s Short Circuit Protection (SCP) will be activated. When this occurs, both LEDs will flash and the sensor will limit current flow to about 2.0mA.
2GND3L1N.O. LOADMINI CONNECTOR MODELSMale views shown3 Wire DC N.O.2 Wire AC/DC N.O.N.O. LOAD14231 (+ DC) (- DC)23L1N.O. LOAD
Namco Controls Corporation Mayfield Village, OH 44143 (440) 460-1360 • FAX (440) 460-3800 • namcocontrols.com
For technical assistance, call 1-800-NAMTECH 77