Page 559

Appendix A

Standard Models H-PCF Optical Fiber Cables (For SYSMAC NET, SYSMAC LINK, and SYSMAC BUS) Name Optical Fiber Cables SYSMAC NET, SYSMAC LINK

Specifications 10 m, black 50 m, black 100 m, black 500 m, black

Optical Fiber Cables SYSMAC NET, SYSMAC LINK, SYSMAC BUS, SYSMAC WAY

Composite cable including two-core cable and two-core power supply cable

S3200-HCLB101

S3200-HCLB502 S3200-HCLB103 S3200-HCLO101

50 m, orange

S3200-HCLO501

100 m, orange

S3200-HCLO102

500 m, orange

S3200-HCLO502

1,000 m, orange

S3200-HCLO103 Two-core cable

S3200-HCLB101

50 m, black

S3200-HCCB501

100 m, black

S3200-HCCB102

500 m, black

S3200-HCCB502

1000 m, black

S3200-HCCB103

10 m, orange

S3200-HCCO101

50 m, orange

S3200-HCCO501

100 m, orange

S3200-HCCO102

500 m, orange

S3200-HCCO502

1,000 m, orange

S3200-HCCO103 Two-core cord

---

S3200-HCLB102

10 m, orange

10 m, black

Standards

S3200-HCLB501

1,000 m, black

10 m, black

Optical Fiber Cable Connector

Model number

S3200-HBCB101

50 m, black

S3200-HBCB501

100 m, black

S3200-HBCB102

500 m, black

S3200-HBCB502

1,000 m, black

S3200-HBCB103

SYSMAC NET: S3200-LSU03-01E B700-AL001 C500-SNT31-V4

Full-lock conS3200-COCH62M nector for NSU, NSB,, and C500 SYSMAC NET Link Unit

SYSMAC BUS: C200H-RM001-PV1 C200H-RT001/RT002-P C500-RM001-(P)V1 C500-RT001/RT002-(P)V1

Half-lock conS3200-COCH82 nector for Remote I/O Master, Remote I/O Slave, Host Link Unit, and Link Adapter

SYSMAC NET/SYSMAC LINK C200HS-SNT32 C200HW-SLK13/14

Half-lock connector

S3200-COCF2511

SYSMAC NET/SYSMAC LINK CV500-SNT31 CV500-SLK11 CV1000H-SLK11

Full-lock connector

S3200-COCF2011

To relay at all SYSMAC NET nodes.

COCF62M and COCF62F are used as a pair.

S3200-COCF62M

---

---

---

S3200-COCF62F

Note: 1. Optical fiber cables must be prepared and connected by specialists.

553

Page 560

Appendix A

Standard Models

2. If the user prepares and connects optical fiber cables, the user must take a seminar held under the auspices of Sumitomo Electric Industries, Ltd. and obtain a proper certificate. 3. The Optical Power Tester, Head Unit, Master Fiber Set, and Optical Fiber Assembling Tool are required to connect optical fiber cables. 4. You may want to use the Plastic Clad Optical Fiber Cable/All Plastic Optical Fiber Cable with connectors listed on the previous two pages. Optical Fiber Assembling Tool Name

Specifications

Model number

Optical Fiber Assembling Tool

Used to connect H-PCF and crimp-cut connectors for optical transmission systems such as the SYSMAC C- and CV-series SYSMAC BUS, SYSMAC LINK and SYSMAC NET.

S3200-CAK1062

Standards ---

Note: 1. Optical fiber cables must be prepared and connected by specialists. 2. The Optical Power Tester, Head Unit, Master Fiber set, and Optical Fiber Assembling Tool are required to connect optical fiber cables. Optical Power Tester Name

Specifications

Head Unit

Model number

S3200-CAT200 2 (provided with the Tester)

S3200-CAT2000

S3200-CAT270 2 (provided with the Tester)

S3200-CAT2700

SYSMAC BUS: C200H-RM001-PV1 C200H-RT001/RT002-P C500-RM001-(P)V1 C500-RT001/RT002-(P)V1

S3200-CAT282 2 (provided with the Tester)

S3200-CAT2820

SYSMAC NET: S3200-LSU03-01E C500-SNT31-V4

S3200-CAT320 2 (provided with the Tester)

S3200-CAT3200

Optical Power Tester (see note) SYSMAC NET: (provided with a connector CV500-SNT31 adapter, light source unit, small C200HS-SNT32 single-head plug, hard case, SYSMAC LINK: and AC adapter) CV500-SLK11 C200HW-SLK13/14 CV1000H-SLK11

Standards ---

Note: There is no difference between the light source unit and connector adapter for the Head Unit and those for the Optical Power Tester. Head Unit Name Head Units (a set consisting of light source unit and connector adapter) (see note)

554

Specifications

Model number

SYSMAC NET: CV500-SNT31 C200HS-SNT32

S3200-CAT2002

SYSMAC LINK: CV500-SLK11 C200HW-SLK13/14 CV1000H-SLK11

S3200-CAT2702

SYSMAC BUS: C500-RM001-(P)V1 C500-RT001/RT002-(P)V1 C200H-RM001-PV1 C200H-RT001/RT002-PV1

S3200-CAT2822

SYSMAC NET: S3200-LSU03-01E C500-SNT31-V4

S3200-CAT3202

Standards ---

Page 561

Appendix A

Standard Models

Note: Use a proper Head Unit model for the optical module to be used. If two types of optical modules (unit type and board type) are used, order an Optical Power Tester plus a proper Head Unit model. Master Fiber Set Name Master Fiber Sets (1 m)

Specifications

Model number

S3200-CAT3202 (SYSMAC NET, NSB, NSU, Bridge)

S3200-CAT3201

S3200-CAT2002/CAT2702 (SYSMAC NET, SYSMAC LINK)

S3200-CAT2001H

S3200-CAT2822 (SYSMAC BUS)

S3200-CAT2821

Standards ---

Note: 1. The Master Fiber Set is used in combination with the Optical Power Tester to check the optical levels of optical fiber cables connected to optical fiber cable connectors. 2. Optical fiber cables must be prepared and connected by specialists. 3. The Optical Power Tester, Head Unit, Master Fiber set, and Optical Fiber Assembling Tool are required to connect optical fiber cables.

Programming Devices Name

Specifications

Model number

Standards

Hand-Held, w/backlight

C200H-PR027-E

U, C

2-m Connecting Cable included

CQM1-PRO01-E

U, C

Programming Console Mounting Bracket

Used to attach Hand-held Programming Console to a panel.

C200H-ATT01

---

Programming Console Connecting Cables

For Hand-held Programming Console

2m

C200H-CN222

---

4m

C200H-CN422

---

Programming Consoles

Data Setting Console

Used for data input and process value display for the C200H-CP114, and

C200H-DSC01

Data Setting Console Connecting Cables

For C200H-DSC01

2m

C200H-CN225

4m

C200H-CN425

Connecting Cable

Used to connect an IBM PC/AT or compatible to the C200HX/HG/HE.

3.3 m

CQM1-CIF02

---

555

Page 562

Appendix A

Standard Models

Optional Products Name I/O Unit Cover

Specifications Cover for 10-pin terminal block

Model number C200H-COV11

Standards ---

Terminal Block Cov- Short protection for 10-pin terminal block (package of 10 covers ers); 8 pts

C200H-COV02

Short protection for 19-pin terminal block (package of 10 covers); 12 pts

C200H-COV03

Connector Cover

Protective cover for unused I/O Connecting Cable connectors

C500-COV02

Space Unit

Used for vacant slots

C200H-SP001

N, L

Battery Set

For C200H or C200HS RAM Memory Unit only

C200H-BAT09

---

Relay

24 VDC

G6B-1174P-FD-US ---

Backplane Insulation Plates

For C200HW-BC031 (3-slot CPU Backplane)

C200H-ATT31

For C200HW-BC051 (5-slot CPU Backplane)

C200H-ATT51

For C200HW-BC081 (8-slot CPU Backplane)

C200H-ATT81

For C200HW-BC101 (10-slot CPU Backplane)

C200H-ATTA1

For C200HW-BI031 (3-slot I/O Backplane)

C200HW-ATT32

For C200HW-BI051 (5-slot I/O Backplane)

C200HW-ATT52

For C200HW-BI081 (8-slot I/O Backplane)

C200HW-ATT82

For C200HW-BI101 (10-slot I/O Backplane)

C200HW-ATTA2

For 3-slot Backplane

C200H-ATT33

For 5-slot Backplane

C200H-ATT53

For 8-slot Backplane

C200H-ATT83

For 10-slot Backplane

C200H-ATTA3

---

External Connectors Solder terminal; 40p and a Connector Cover

C500-CE401

---

Solderless terminal; 40p and a Connector Cover (Crimp-type)

C500-CE402

---

Pressure welded terminal; 40p

C500-CE403

---

Solder terminal; 40p and a Connector Cover (Horizontal-type)

C500-CE404

---

Crimp-style terminal; 40p and a Connector Cover (Horizontaltype)

C500-CE405

---

I/O Brackets

556

---

N

Page 563

Appendix A

Standard Models

Mounting Rails and Accessories Name

Specifications

Model number

DIN Track Mounting Bracket

1 set (2 included)

C200H-DIN01

DIN Tracks

Length: 50 cm; height: 7.3 cm

PFP-50N

Length: 1 m; height: 7.3 cm

PFP-100N

Length: 1 m; height: 16 mm

PFP-100N2

End Plate

---

PFP-M

Spacer

---

PFP-S

Standards ---

Note: Order DIN Tracks, End Plates, and Spacers in units of 10 each. CX-Programmer Support Software Name CX-Programmer

Specifications Windows 95/98 Version 1.2 or higher

Model number WS02-CXPC1-E

Standards ---

SYSMAC-CPT Support Software Name SYSMAC Support Software (for C20, C120, C200H, C200HS, C200HE, C200HG, C200HX, C500, C1000H, C2000H, CQM1, and CVM1)

Specifications 3.5”, 2HD for IBM PC/AT compatible

Model number C500-ZL3AT1-E

Standards ---

Note: Version 1.0 doesn’t support the additional functions of the C200HX/HG/HE.

Protocol Support Software Name Protocol Support Software

Specifications 3.5”, 2HD for IBM PC/AT compatible

Model number C200HW-ZW3AT1-E

Standards ---

Training Materials Name

Specifications

Model number

Standards

SYSMAC Training System

Includes text book, cassette tape, and input switch board.

C200H-ETL01-E

---

Fuzzy Training System

Includes a Fuzzy Training System Manual, a Main C200H-ETL13-E Unit, a C200H-MR831 Memory Unit, a C200H-PRO27-E Programming Console, a C200H-CN222 Cable for the Programming Console, C500-SU981-E Fuzzy Training Software, an RS-232C Cable, and a carrying belt.

---

557

Page 564

Appendix B Programming Instructions A PC instruction is input either by pressing the corresponding Programming Console key(s) (e.g., LD, AND, OR, NOT) or by using function codes. To input an instruction with its function code, press FUN, the function code, and then WRITE. Refer to the pages listed programming and instruction details. The default function codes are shown for expansion instructions that have them. A code of (––) is shown for the expansion instructions without default function codes. Code

Mnemonic, AND

AND

Name, AND LD

AND LOAD, AND NOT

AND NOT, CNT

COUNTER, LD, - Function

Page

Logically ANDs status of designated bit with execution condition. Logically ANDs results of preceding blocks.

160

Logically ANDs inverse of designated bit with execution condition. A decrementing counter.

160

LOAD

Used to start instruction line with the status of the designated bit or to define a logic block for use with AND LD and OR LD.

160

LD NOT

LOAD NOT

Used to start instruction line with inverse of designated bit.

160

OR

OR

160, OR LD

OR LOAD

Logically ORs status of designated bit with execution condition. Logically ORs results of preceding blocks., OR NOT

OR NOT

160, OUT

OUTPUT, OUT NOT

OUTPUT NOT

Logically ORs inverse of designated bit with execution condition. Turns ON operand bit for ON execution condition; turns OFF operand bit for OFF execution condition. Turns operand bit OFF for ON execution condition; turns operand bit ON for OFF execution condition (i.e., inverts operation)., RSET

RESET

Turns the operand bit OFF when the execution condition is 164 ON, and does not affect the status of the operand bit when the execution condition is OFF., SET

SET

Turns the operand bit ON when the execution condition is ON, and does not affect the status of the operand bit when the execution condition is OFF.

164, TIM

TIMER

ON-delay (decrementing) timer operation.

171

000

NOP

NO OPERATION

170

001

END

END

002

IL

INTERLOCK

003

ILC

INTERLOCK CLEAR

Nothing is executed and program moves to next instruction. Required at the end of the program. If interlock condition is OFF, all outputs are turned OFF and all timer PVs reset between this IL(002) and the next ILC(003). Other instructions are treated as NOP; counter PVs are maintained.

004 005 006

JMP JME (@) FAL

If jump condition is OFF, all instructions between JMP(004) and the corresponding JME(005) are ignored.

169 169 338

007

FALS

008

STEP

JUMP JUMP END FAILURE ALARM AND RESET SEVERE FAILURE ALARM STEP DEFINE

009

SNXT

STEP START

010

SFT

SHIFT REGISTER

Used with a control bit to indicate the end of the step, reset the step, and start the next step. Creates a bit shift register.

Generates a non-fatal error and outputs the designated FAL number to the Programming Console. Generates a fatal error and outputs the designated FALS number to the Programming Console. When used with a control bit, defines the start of a new step and resets the previous step. When used without N, defines the end of step execution.

161

178

161

161 161

170 167 167

338 329

329 183

559

Page 565

Appendix B

Programming Instructions Code

Mnemonic

Name

Function

Page

011

KEEP

KEEP

Defines a bit as a latch controlled by set and reset inputs.

165

012

CNTR

REVERSIBLE COUNTER

Increases or decreases PV by one whenever the increment input or decrement input signals, respectively, go from OFF to ON.

181

013

DIFU

DIFFERENTIATE UP

162

014

DIFD

015

TIMH

DIFFERENTIATE DOWN HIGH-SPEED TIMER

Turns ON the designated bit for one cycle on the rising edge of the input signal. Turns ON the bit for one cycle on the trailing edge. A high-speed, ON-delay (decrementing) timer.

176

016

(@) WSFT

WORD SHIFT

190

017

(@) ASFT

ASYNCHRONOUS SHIFT REGISTER

Shifts data between starting and ending words in word units, writing zeros into starting word. Creates a shift register that exchanges the contents of adjacent words when one of the words is zero and the other is not.

018

(@) SCAN

CYCLE TIME

Sets the minimum cycle time (0 to 999.0 s).

339

019

(@) MCMP CMP

021

(@) MOV

MOVE

Compares a block of 16 consecutive words to another block of 16 consecutive words. Compares the contents of two words and outputs result to GR, EQ, and LE Flags. Copies source data (word or constant) to destination word.

205

020

MULTI-WORD COMPARE COMPARE

022

(@) MVN

MOVE NOT

193

023

(@) BIN

BCD TO BINARY

024

(@) BCD

BINARY TO BCD

025

(@) ASL

026

(@) ASR

027

(@) ROL

ARITHMETIC SHIFT LEFT ARITHMETIC SHIFT RIGHT ROTATE LEFT

Inverts source data (word or constant) and then copies it to destination word. Converts four-digit, BCD data in source word into 16-bit binary data, and outputs converted data to result word. Converts binary data in source word into BCD, and outputs converted data to result word. Shifts each bit in single word of data one bit to left, with CY. Shifts each bit in single word of data one bit to right, with CY. Rotates bits in single word of data one bit to left, with CY.

028

(@) ROR

ROTATE RIGHT

Rotates bits in single word of data one bit to right, with CY.

188

029

(@) COM

COMPLEMENT

Inverts bit status of one word of data.

313

030

(@) ADD

BCD ADD

266

031

(@) SUB

BCD SUBTRACT

032

(@) MUL

BCD MULTIPLY

033

(@) DIV

BCD DIVIDE

034

(@) ANDW

LOGICAL AND

Adds two four-digit BCD values and content of CY, and outputs result to specified result word. Subtracts a four-digit BCD value and CY from another four-digit BCD value and outputs result to the result word. Multiplies two four-digit BCD values and outputs result to specified result words. Divides four-digit BCD dividend by four-digit BCD divisor and outputs result to specified result words. Logically ANDs two 16-bit input words and sets corresponding bit in result word if corresponding bits in input words are both ON.

035

(@) ORW

LOGICAL OR

Logically ORs two 16-bit input words and sets corresponding bit in result word if one or both of corresponding bits in input data are ON.

315

036

(@) XORW

EXCLUSIVE OR

Exclusively ORs two 16-bit input words and sets bit in result word when corresponding bits in input words differ in status.

316

037

(@) XNRW

EXCLUSIVE NOR

Exclusively NORs two 16-bit input words and sets bit in result word when corresponding bits in input words are same in status.

317

038

(@) INC

BCD INCREMENT

Increments four-digit BCD word by one.

265

039

(@) DEC

BCD DECREMENT

Decrements four-digit BCD word by one.

265

040

(@) STC

SET CARRY

Sets carry flag (i.e., turns CY ON).

265

560

162

191

206 192

220 221 187 187 188

268 271 273 314

Page 566

Appendix B

Programming Instructions Code

Mnemonic

Name

Function

Page

041

(@) CLC

CLEAR CARRY

Clears carry flag (i.e, turns CY OFF).

265

045

TRSM

TRACE MEMORY SAMPLE

Initiates data tracing.

340

046

(@) MSG

MESSAGE

Displays a 16-character message on the Programming Console display.

341

047

(@) LMSG

32-CHARACTER MESSAGE

Outputs a 32-character message to the Programming Console.

342

048

(@) TERM

TERMINAL MODE

Switches the Programming Console to TERMINAL mode for the normal keyboard mapping operation.

343

050

(@) ADB

BINARY ADD

Adds two four-digit hexadecimal values and content of CY, and outputs result to specified result word.

280

051

(@) SBB

BINARY SUBTRACT

Subtracts a four-digit hexadecimal value and CY from another four-digit hexadecimal value and outputs result to the result word.

282

052

(@) MLB

BINARY MULTIPLY

Multiplies two four-digit hexadecimal values and outputs result to specified result words.

285

053

(@) DVB

BINARY DIVIDE

Divides four-digit hexadecimal dividend by four-digit hexadecimal divisor and outputs result to specified result words.

285

054

(@) ADDL

DOUBLE BCD ADD

Adds two eight-digit values (2 words each) and content of CY, and outputs result to specified result words.

267

055

(@) SUBL

DOUBLE BCD SUBTRACT

Subtracts an eight-digit BCD value and CY from another eight-digit BCD value and outputs result to the result words.

270

056

(@) MULL

DOUBLE BCD MULTIPLY

Multiplies two eight-digit BCD values and outputs result to specified result words.

272

057

(@) DIVL

DOUBLE BCD DIVIDE

Divides eight-digit BCD dividend by eight-digit BCD divisor and outputs result to specified result words.

274

058

(@) BINL

DOUBLE BCD TO DOUBLE BINARY

Converts BCD value in two consecutive source words into binary and outputs converted data to two consecutive result words.

221

059

(@) BCDL

DOUBLE BINARY TO DOUBLE BCD

Converts binary value in two consecutive source words into BCD and outputs converted data to two consecutive result words.

222

060

CMPL

DOUBLE COMPARE

Compares two eight-digit hexadecimal values.

209

061

(@) MPRF

GROUP-2 HIGHDENSITY I/O REFRESH

Refreshes I/O words allocated to Group-2 High-density I/O 345 Units.

062

(@) XFRB

TRANSFER BITS

Copies the status of up to 255 specified source bits to the specified destination bits.

201

063

(@) LINE

COLUMN TO LINE

Copies a bit column from 16 consecutive words to the specified word.

240

064

(@) COLM

LINE TO COLUMN

Copies the 16 bits from the specified word to a bit column of 16 consecutive words.

241

065

(@) SEC

HOURS TO SECONDS

Converts hour and minute data to second data.

223

066

(@) HMS

SECONDS TO HOURS

Converts second data to hour and minute data.

224

067

(@) BCNT

BIT COUNTER

Counts the total number of bits that are ON in the specified block of words.

346

068

(@) BCMP

BLOCK COMPARE

Judges whether the value of a word is within 16 ranges (defined by lower and upper limits).

210

069

(@) APR

ARITHMETIC PROCESS

Performs sine, cosine, or linear approximation calculations.

300

070

(@) XFER

BLOCK TRANSFER

Moves content of several consecutive source words to consecutive destination words.

195

561

Page 567

Appendix B

Programming Instructions Code

Mnemonic

Name

071

(@) BSET

BLOCK SET

072

(@) ROOT

073

Function

Page 193

SQUARE ROOT

Copies content of one word or constant to several consecutive words. Computes square root of eight-digit BCD value and outputs truncated four-digit integer result to specified result word.

(@) XCHG

DATA EXCHANGE

Exchanges contents of two different words.

195

074

(@) SLD

ONE DIGIT SHIFT LEFT

Left shifts data between starting and ending words by one digit (four bits).

189

075

(@) SRD (@) MLPX

Right shifts data between starting and ending words by one digit (four bits). Converts up to four hexadecimal digits in source word into decimal values from 0 to 15 and turns ON, in result word(s), bit(s) whose position corresponds to converted value.

189

076

ONE DIGIT SHIFT RIGHT 4-TO-16/8-TO-256 DECODER

278

225

Can also convert up to eight hexadecimal digits and turn ON corresponding bits in result words R to R+15. 077

(@) DMPX

16-TO-4/256-TO-8 ENCODER

Determines position of highest ON bit in source word(s) and writes the ON bit’s position (0 to F) to digit(s) in R.

228

Can also determine the position of the highest ON bit in one or two groups of 16 words (S to S+15, S+16 to S+31) and writes the ON bit’s position (00 to FF) to byte(s) in R. 078

(@) SDEC

7-SEGMENT DECODER FLOATING POINT DIVIDE SINGLE WORD DISTRIBUTE

Converts hexadecimal values from source word to data for seven-segment display. Divides one floating point value (Dd+1, Dd) by another (Dr+1, Dr) and outputs the result to R+1 and R. Moves one word of source data to destination word whose address is given by destination base word plus offset.

231

079

(@) FDIV

080

(@) DIST

081

(@) COLL

DATA COLLECT

197

082

(@) MOVB

MOVE BIT

083

(@) MOVD

MOVE DIGIT

Extracts data from source word and writes it to destination word. Transfers designated bit of source word or constant to designated bit of destination word. Moves hexadecimal content of specified four-bit source digit(s) to specified destination digit(s) for up to four digits.

084

(@) SFTR (@) TCMP

086

(@) ASC

ASCII CONVERT

Shifts data in specified word or series of words to either left or right. Compares four-digit hexadecimal value with values in table consisting of 16 words. Converts hexadecimal values from the source word to eight-bit ASCII code starting at leftmost or rightmost half of starting destination word.

185

085

REVERSIBLE SHIFT REGISTER TABLE COMPARE

087

TTIM

TOTALIZING TIMER

Creates a totalizing timer.

177

088

ZCP (@) INT

090

(@) SEND

Compares a word to a range defined by lower and upper limits and outputs the result to the GR, EQ, and LE flags. Performs interrupt control, such as masking and unmasking the interrupt bits for I/O interrupts. Used for communications with other PCs linked through the SYSMAC NET Link System or SYSMAC LINK System.

213

089

AREA RANGE COMPARE INTERRUPT CONTROL NETWORK SEND

091

(@) SBS

Calls and executes subroutine N.

321

092

SBN

Marks start of subroutine N.

322

093

RET

SUBROUTINE ENTRY SUBROUTINE DEFINE RETURN

Marks the end of a subroutine and returns control to main program.

322

094

(@) WDT

Increases the watchdog timer PV by 0 to 6300 ms.

344

097

(@) IORF

WATCHDOG TIMER REFRESH I/O REFRESH

Refreshes all I/O words between the start and end words.

344

562

275 196

200 200

212 234

325 356

Page 568

Appendix B

Programming Instructions Code

Mnemonic

Name

Function

Page

098

(@) RECV

NETWORK RECEIVE

Used for communications with other PCs linked through the SYSMAC NET Link System or SYSMAC LINK System.

362

099

(@) MCRO

MACRO

Calls and executes a subroutine replacing I/O words.

323

114

(@) CPS

SIGNED BINARY COMPARE

Compares two 16-bit (4-digit) signed binary values and outputs the result to the GR, EQ, and LE flags.

215

115

(@) CPSL

DOUBLE SIGNED BINARY COMPARE

Compares two 32-bit (8-digit) signed binary values and outputs the result to the GR, EQ, and LE flags.

216

116

(@) ZCPL

DOUBLE AREA RANGE COMPARE

Compares an 8-digit value to a range defined by lower and 214 upper limits and outputs the result to the GR, EQ, and LE flags.

125

(@) BXFR

EM BANK TRANSFER

Moves content of several consecutive source words to consecutive destination words. Words in any EM bank can be specified for the source or destination.

204

160

(@) NEG

2’S COMPLEMENT

Converts the four-digit hexadecimal content of the source word to its 2’s complement and outputs the result to R.

242

161

(@) NEGL

DOUBLE 2’S COMPLEMENT

Converts the eight-digit hexadecimal content of the source words to its 2’s complement and outputs the result to R and R+1.

243

162

(@) HEX

ASCII-TO-HEXADECI MAL

Converts ASCII data to hexadecimal data.

235

180

(@) FCS

FCS CALCULATE

Checks for errors in data transmitted by a Host Link command.

346

181

(@) SRCH

DATA SEARCH

Searches the specified range of memory for the specified data. Outputs the word address(es) of words in the range that contain the data.

352

182

(@) MAX

FIND MAXIMUM

Finds the maximum value in specified data area and outputs that value to another word.

294

183

(@) MIN

FIND MINIMUM

Finds the minimum value in specified data area and outputs that value to another word.

295

184

(@) SUM

SUM CALCULATE

Computes the sum of the contents of the words in the specified range of memory.

299

190

(@) PID

PID CONTROL

PID control is performed according to the operand and PID parameters that are preset.

303

194

(@) SCL

SCALING

Performs a scaling conversion on the calculated value.

238

195

AVG

AVERAGE VALUE

Adds the specified number of hexadecimal words and computes the mean value. Rounds off to 4 digits past the decimal point.

297

210

DSW

DIGITAL SWITCH INPUT

Inputs 4- or 8-digit BCD data from a digital switch.

376

211

TKY

TEN KEY INPUT

Inputs 8 digits of BCD data from a 10-key keypad.

380

212

HKY

HEXADECIMAL KEY INPUT

Inputs up to 8 digits of hexadecimal data from a 16-key keypad.

382

213

MTR

MATRIX INPUT

Inputs data from an 8 input point × 8 output point matrix and records that data in D to D+3.

385

214

7SEG

7-SEGMENT DISPLAY OUTPUT

Converts 4- or 8-digit BCD data to 7-segment display format and then outputs the converted data.

387

222

(@) IORD

SPECIAL I/O UNIT READ

Transfers data from the specified Special I/O Unit’s memory to words in the PC.

391

223

(@) IOWR

SPECIAL I/O UNIT WRITE

Transfers data from words in the PC to the specified Special I/O Unit’s memory.

392

235

(@) RXD

RECEIVE

Receives data via a communications port.

368

236

(@) TXD

TRANSMIT

Sends data via a communications port.

370

237

(@) STUP

CHANGE RS-232C SETUP

Changes the PC Setup settings for the specified port.

373

563