Page 596
Glossary loop
A group of instructions that can be executed more than once in succession (i.e., repeated) depending on an execution condition or bit status.
LR area
A data area that is used in a PC Link System so that data can be transferred between two or more PCs. If a PC Link System is not used, the LR area is available for use as work bits.
LSS
Abbreviation for Ladder Support Software.
main program
All of a program except for the subroutines.
masking
‘Covering’ an interrupt signal so that the interrupt is not effective until the mask is removed.
Master
Short for Remote I/O Master Unit.
memory area
Any of the areas in the PC used to hold data or programs.
mnemonic code
A form of a ladder-diagram program that consists of a sequential list of the instructions without using a ladder diagram. Mnemonic code is required to input a program into a PC when using a Programming Console.
MONITOR mode
A mode of PC operation in which normal program execution is possible, and which allows modification of data held in memory. Used for monitoring or debugging the PC.
most-significant (bit/word)
See leftmost (bit/word).
NC input
An input that is normally closed, i.e., the input signal is considered to be present when the circuit connected to the input opens.
nest
Programming one loop within another loop, programming a call to a subroutine within another subroutine, or programming an IF-ELSE programming section within another IF-ELSE section.
Net Link System
An optical LAN formed from PCs connected through Net Link Units. A Net Link System also normally contains nodes interfacing computers and other peripheral devices. PCs in the Net Link System can pass data back and forth, receive commands from any interfaced computer, and share any interfaced peripheral device.
Net Link Unit
The Unit used to connect PCs to a Net Link System. The full name is “SYSMAC Net Link Unit.”
Network Service Board
A device with an interface to connect devices other than PCs to a Net Link System.
Network Service Unit
A Unit that provides two interfaces to connect peripheral devices to a Net Link System.
node
One of the positions in a LAN. Each node incorporates a device that can communicate with the devices at all of the other nodes. The device at a node is identified by the node number. One loop of a Net Link System (OMRON’s LAN) can consist of up to 126 nodes. Each node is occupied by a Net Link Unit mounted to a PC or a device providing an interface to a computer or other peripheral device.
NO input
An input that is normally open, i.e., the input signal is considered to be present when the circuit connected to the input closes.
595
Page 597
Glossary noise interference
Disturbances in signals caused by electrical noise.
nonfatal error
A hardware or software error that produces a warning but does not stop the PC from operating.
normal condition
A condition that produces an ON execution condition when the bit assigned to it is ON, and an OFF execution condition when the bit assigned to it is OFF.
NOT
A logic operation which inverts the status of the operand. For example, AND NOT indicates an AND operation with the opposite of the actual status of the operand bit.
NSB
An acronym for Network Service Board.
NSU
An acronym for Network Service Unit.
OFF
The status of an input or output when a signal is said not to be present. The OFF state is generally represented by a low voltage or by non-conductivity, but can be defined as the opposite of either.
OFF delay
The delay between the time when a signal is switched OFF (e.g., by an input device or PC) and the time when the signal reaches a state readable as an OFF signal (i.e., as no signal) by a receiving party (e.g., output device or PC).
ON
The status of an input or output when a signal is said to be present. The ON state is generally represented by a high voltage or by conductivity, but can be defined as the opposite of either.
ON delay
The delay between the time when an ON signal is initiated (e.g., by an input device or PC) and the time when the signal reaches a state readable as an ON signal by a receiving party (e.g., output device or PC).
one-shot bit
A bit that is turned ON or OFF for a specified interval of time which is longer than one cycle.
on-line removal
Removing a Rack-mounted Unit for replacement or maintenance during PC operation.
operand
Bit(s) or word(s) designated as the data to be used for an instruction. An operand can be input as a constant expressing the actual numeric value to be used or as an address to express the location in memory of the data to be used.
operand bit
A bit designated as an operand for an instruction.
operand word
A word designated as an operand for an instruction.
operating error
An error that occurs during actual PC operation as opposed to an initialization error, which occurs before actual operations can begin.
Optical I/O Unit
A Unit that is connected in an Optical Remote I/O System to provide 8 I/O points. Optical I/O Units are not mounted to a Rack.
Optical Slave Rack
A Slave Rack connected through an Optical Remote I/O Slave Unit.
OR
A logic operation whereby the result is true if either of two premises is true, or if both are true. In ladder-diagram programming the premises are usually ON/OFF states of bits or the logical combination of such states called execution conditions.
596
Page 598
Glossary output
The signal sent from the PC to an external device. The term output is often used abstractly or collectively to refer to outgoing signals.
output bit
A bit in the IR area that is allocated to hold the status to be sent to an output device.
output device
An external device that receives signals from the PC System.
output point
The point at which an output leaves the PC System. Output points correspond physically to terminals or connector pins.
output signal
A signal being sent to an external device. Generally an output signal is said to exist when, for example, a connection point goes from low to high voltage or from a nonconductive to a conductive state.
overseeing
Part of the processing performed by the CPU that includes general tasks required to operate the PC.
overwrite
Changing the content of a memory location so that the previous content is lost.
parity
Adjustment of the number of ON bits in a word or other unit of data so that the total is always an even number or always an odd number. Parity is generally used to check the accuracy of data after being transmitted by confirming that the number of ON bits is still even or still odd.
PC
An acronym for Programmable Controller.
PCB
An acronym for printed circuit board.
PC configuration
The arrangement and interconnections of the Units that are put together to form a functional PC.
PCF
Acronym for plastic-clad optical fiber cable.
PC Link System
A system in which PCs are connected through PC Link Units to enable them to share common data areas, i.e., each of the PCs writes to certain words in the LR area and receives the data of the words written by all other PC Link Units connected in series with it.
PC Link Unit
The Unit used to connect PCs in a PC Link System.
PC System
With building-block PCs, all of the Racks and independent Units connected directly to them up to, but not including the I/O devices. The boundaries of a PC System are the PC and the program in its CPU at the upper end; and the I/O Units, Special I/O Units, Optical I/O Units, Remote Terminals, etc., at the lower end.
peripheral device
Devices connected to a PC System to aid in system operation. Peripheral devices include printers, programming devices, external storage media, etc.
port
A connector on a PC or computer that serves as a connection to an external device.
present value
The current value registered in a device at any instant during its operation. Present value is abbreviated as PV.
printed circuit board
A board onto which electrical circuits are printed for mounting into a computer or electrical device.
597
Page 599
Glossary Printer Interface Unit
A Unit used to interface a printer so that ladder diagrams and other data can be printed out.
program
The list of instructions that tells the PC the sequence of control actions to be carried out.
Programmable Controller
A computerized device that can accept inputs from external devices and generate outputs to external devices according to a program held in memory. Programmable Controllers are used to automate control of external devices. Although single-component Programmable Controllers are available, building-block Programmable Controllers are constructed from separate components. Such building-block Programmable Controllers are formed only when enough of these separate components are assembled to form a functional assembly, i.e., no one individual Unit is called a PC.
programmed alarm
An alarm given as a result of execution of an instruction designed to generate the alarm in the program, as opposed to one generated by the system.
programmed error
An error arising as a result of the execution of an instruction designed to generate the error in the program, as opposed to one generated by the system.
programmed message
A message generated as a result of execution of an instruction designed to generate the message in the program, as opposed to one generated by the system.
Programming Console
The simplest form or programming device available for a PC. Programming Consoles are available both as hand-held models and as CPU-mounting models.
Programming Device
A peripheral device used to input a program into a PC or to alter or monitor a program already held in the PC. There are dedicated programming devices, such as Programming Consoles, and there are non-dedicated devices, such as a host computer.
PROGRAM mode
A mode of operation that allows inputting and debugging of programs to be carried out, but that does not permit normal execution of the program.
PROM Writer
A peripheral device used to write programs and other data into a ROM for permanent storage and application.
prompt
A message or symbol that appears on a display to request input from the operator.
PV
Acronym for present value.
Rack
An assembly of various Units on a Backplane that forms a functional unit in a building-block PC System. Racks include CPU Racks, Expansion I/O Racks, I/O Racks, and Slave Racks.
refresh
The process of updating output status sent to external devices so that it agrees with the status of output bits held in memory and of updating input bits in memory so that they agree with the status of inputs from external devices.
relay-based control
The forerunner of PCs. In relay-based control, groups of relays are interconnected to form control circuits. In a PC, these are replaced by programmable circuits.
Remote I/O Master Unit
The Unit in a Remote I/O System through which signals are sent to all other Remote I/O Units. The Remote I/O Master Unit is mounted either to a CPU Rack or
598
Page 600
Glossary an Expansion I/O Rack connected to the CPU Rack. Remote I/O Master Unit is generally abbreviated to Master. Remote I/O Slave Unit
A Unit mounted to a Backplane to form a Slave Rack. Remote I/O Slave Unit is generally abbreviated to Slave.
Remote I/O System
A system in which remote I/O points are controlled through a Master mounted to a CPU Rack or an Expansion I/O Rack connected to the CPU Rack.
Remote I/O Unit
Any of the Units in a Remote I/O System. Remote I/O Units include Masters, Slaves, Optical I/O Units, I/O Link Units, and Remote Terminals.
remote I/O word
An I/O word allocated to a Unit in a Remote I/O System.
reset
The process of turning a bit or signal OFF or of changing the present value of a timer or counter to its set value or to zero.
return
The process by which instruction execution shifts from a subroutine back to the main program (usually the point from which the subroutine was called).
reversible counter
A counter that can be both incremented and decremented depending on the specified conditions.
reversible shift register
A shift register that can shift data in either direction depending on the specified conditions.
right-hand instruction
Another term for terminal instruction.
rightmost (bit/word)
The lowest numbered bits of a group of bits, generally of an entire word, or the lowest numbered words of a group of words. These bits/words are often called least-significant bits/words.
rotate register
A shift register in which the data moved out from one end is placed back into the shift register at the other end.
RUN mode
The operating mode used by the PC for normal control operations.
scheduled interrupt
An interrupt that is automatically generated by the system at a specific time or program location specified by the operator. Scheduled interrupts result in the execution of specific subroutines that can be used for instructions that must be executed repeatedly for a specified period of time.
self diagnosis
A process whereby the system checks its own operation and generates a warning or error if an abnormality is discovered.
self-maintaining bit
A bit that is programmed to maintain either an OFF or ON status until set or reset by specified conditions.
servicing
The process whereby the PC provides data to or receives data from external devices or remote I/O Units, or otherwise handles data transactions for Link Systems.
set
The process of turning a bit or signal ON.
set value
The value from which a decrementing counter starts counting down or to which an incrementing counter counts up (i.e., the maximum count), or the time from which or for which a timer starts timing. Set value is abbreviated SV.
599
Page 601
Glossary shift register
One or more words in which data is shifted a specified number of units to the right or left in bit, digit, or word units. In a rotate register, data shifted out one end is shifted back into the other end. In other shift registers, new data (either specified data, zero(s) or one(s)) is shifted into one end and the data shifted out at the other end is lost.
Slave
Short for Remote I/O Slave Unit.
Slave Rack
A Rack containing a Remote I/O Slave Unit and controlled through a Remote I/O Master Unit. Slave Racks are generally located away from the CPU Rack.
slot
A position on a Rack (Backplane) to which a Unit can be mounted.
software error
An error that originates in a software program.
software protect
A means of protecting data from being changed that uses software as opposed to a physical switch or other hardware setting.
source
The location from which data is taken for use in an instruction, as opposed to the location to which the result of an instruction is to be written. The latter is called the destination.
Special I/O Unit
A dedicated Unit that is designed for a specific purpose. Special I/O Units include Position Control Units, High-Speed Counter Units, Analog I/O Units, etc.
SR area
A data area in a PC used mainly for flags, control bits, and other information provided about PC operation. The status of only certain SR bits may be controlled by the operator, i.e., most SR bits can only be read.
SSS
Abbreviation for SYSMAC Support Software.
subroutine
A group of instructions placed after the main program and executed only if called from the main program or activated by an interrupt.
subroutine number
A definer used to identify the subroutine that a subroutine call or interrupt activates.
SV
Abbreviation for set value.
switching capacity
The maximum voltage/current that a relay can safely switch on and off.
syntax error
An error in the way in which a program is written. Syntax errors can include ‘spelling’ mistakes (i.e., a function code that does not exist), mistakes in specifying operands within acceptable parameters (e.g., specifying reserved SR bits as a destination), and mistakes in actual application of instructions (e.g., a call to a subroutine that does not exist).
SYSMAC Support Software
A software package installed on a IBM PC/AT or compatible computer to function as a Programming Device.
system configuration
The arrangement in which Units in a system are connected.
system error
An error generated by the system, as opposed to one resulting from execution of an instruction designed to generate an error.
system error message
An error message generated by the system, as opposed to one resulting from execution of an instruction designed to generate a message.
600
Page 602
Glossary TC area
A data area that can be used only for timers and counters. Each bit in the TC area serves as the access point for the SV, PV, and Completion flag for the timer or counter defined with that bit.
TC number
A definer that corresponds to a bit in the TC area and used to define the bit as either a timer or a counter.
terminal instruction
An instruction placed on the right side of a ladder diagram that uses the final execution conditions of an instruction line.
terminator
The code comprising an asterisk and a carriage return (* CR) which indicates the end of a block of data, whether it is a single-frame or multi-frame block. Frames within a multi-frame block are separated by delimiters.
timer
A location in memory accessed through a TC bit and used to time down from the timer’s set value. Timers are turned ON and reset according to their execution conditions.
TM area
A memory area used to store the results of a trace.
transmission distance
The distance that a signal can be transmitted.
TR area
A data area used to store execution conditions so that they can be reloaded later for use with other instructions.
trace
An operation whereby the program is executed and the resulting data is stored in TM memory to enable step-by-step analysis and debugging.
transfer
The process of moving data from one location to another within the PC, or between the PC and external devices. When data is transferred, generally a copy of the data is sent to the destination, i.e., the content of the source of the transfer is not changed.
trigger address
An address in the program that defines the beginning point for tracing. The actual beginning point can be altered from the trigger by defining either a positive or negative delay.
UM area
The memory area used to hold the active program, i.e., the program that is being currently executed.
Unit
In OMRON PC terminology, the word Unit is capitalized to indicate any product sold for a PC System. Though most of the names of these products end with the word Unit, not all do, e.g., a Remote Terminal is referred to in a collective sense as a Unit. Context generally makes any limitations of this word clear.
unit number
A number assigned to some Link Units and Special I/O Units to facilitate identification when assigning words or other operating parameters to it.
watchdog timer
A timer within the system that ensures that the cycle time stays within specified limits. When limits are reached, either warnings are given or PC operation is stopped depending on the particular limit that is reached.
Wired Slave Rack
A Slave Rack connected through a Wired Remote I/O Slave Unit.
word
A unit of data storage in memory that consists of 16 bits. All data areas consists of words. Some data areas can be accessed only by words; others, by either words or bits.
601
Page 603
Glossary word address
The location in memory where a word of data is stored. A word address must specify (sometimes by default) the data area and the number of the word that is being addressed.
word multiplier
A value between 0 and 3 that is assigned to a Master in a Remote I/O System so that words can be allocated to non-Rack-mounting Units within the System. The word setting made on the Unit is added to 32 times the word multiplier to arrive at the actual word to be allocated.
work bit
A bit in a work word.
work word
A word that can be used for data calculation or other manipulation in programming, i.e., a ‘work space’ in memory. A large portion of the IR area is always reserved for work words. Parts of other areas not required for special purposes may also be used as work words, e.g., LR words not used in a PC Link or Net Link System.
602