Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 5 of 15

F150-3 Vision Sensor Setup Manual: SECTION 2 Product Introduction, pages 22 to 29

Pages 22 to 29 of 96, from F150-3 Vision Sensor Setup Manual

The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Omron F150 and Omron F150-S1A

Page 22

Z141-E1-03.book Page 7 Monday, July 24, 2006 5:16 PM

SECTION 2 Product Introduction This section provides an overview of F150 application and describes the wiring, Cameras, optical lenses, lighting modes, and light guides used in the F150. It also describes how to mount the Vision Mate Controller to DIN Track or to a flat surface.

2-1

Overview of F150 Application . . . . . . . . . . . . . . . . . . . .

8

2-2

Component Names and Functions . . . . . . . . . . . . . . . . .

9

2-3

Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

2-4

Power Supply and Ground . . . . . . . . . . . . . . . . . . . . . . .

14

2-4-1 Crimp Terminals and Cables . . . . . . . . . . . . . . . . . . . . .

14

2-4-2 Protective Conductor (Earth) Wiring . . . . . . . . . . . . . . .

15

2-4-3 Wiring the Power Supply . . . . . . . . . . . . . . . . . . . . . . . .

15

2-5

Cameras with Light Sources . . . . . . . . . . . . . . . . . . . . . .

17

2-6

CCTV Lens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20

2-6-1 Optical Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20

2-7 2-8

2-9

2-6-2 Lens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

22

2-6-3 Extension Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

22

Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

23

2-7-1 Lighting Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

23

Two-camera Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

25

2-8-1 Connecting to the Power Supply . . . . . . . . . . . . . . . . . .

25

2-8-2 Connecting to the F150 . . . . . . . . . . . . . . . . . . . . . . . . .

25

2-8-3 Connecting to Cameras . . . . . . . . . . . . . . . . . . . . . . . . .

26

Mounting the Controller . . . . . . . . . . . . . . . . . . . . . . . . .

27

2-9-1 Mounting to DIN Track . . . . . . . . . . . . . . . . . . . . . . . . .

27

2-9-2 Mounting on a Flat Surface . . . . . . . . . . . . . . . . . . . . . .

28

7

Page 23

Z141-E1-03.book Page 8 Monday, July 24, 2006 5:16 PM

Section 2-1

Overview of F150 Application

2-1

Overview of F150 Application The following table shows the basic steps that must be performed to use the F150. Step

1:

Manual

Unit Connections and Wiring Programmable Controller

Setup Manual Video Monitor

Power Supply

Console Synchronous sensor Camera with Light Source

IBM PC/AT or compatible computer

2:

Setting Measurement Conditions

3: Confirming Operation, Measuring Objects, and Outputting Results IBM PC/AT or compatible computer

Synchronous sensor

8

Programmable Controller

Expert Menu Operation Manual

Page 24

Z141-E1-03.book Page 9 Monday, July 24, 2006 5:16 PM

Section 2-2

Component Names and Functions

2-2

Component Names and Functions The following diagram shows the terminals, connectors, and indicators on the F150-C10E-3 and F150-C15E-3 Vision Mate Controller.

F150-C10E-3 F150-C15E-3 Ground Power supply Output terminal terminals terminals

Input terminals

POWER indicator Monitor connector

RUN indicator ERROR indicator

Console connector

RS-232C connector

Camera connector

Output terminals

Do not open.

G Ground Terminal A POWER Indicator Wired to the ground. Lit while power is ON. H Input Terminals B RUN Indicator Wired to external devices, such as Lit in RUN mode. synchronous sensors or inputs C ERROR Indicator from a Programmable Controller. Lit when an error occurs. I Output Terminals D RS-232C Connector Wired to external devices, such as Connects the F150 to a computer, synchronous sensors or outputs to Programmable Controller, or other a Programmable Controller. external device. J Monitor Connector E Camera Connector Connects to the video monitor. Connects to the Camera. K Console Connector F Power Supply Terminals Connects to the Console. Wired to the power supply.

9

Page 25

Z141-E1-03.book Page 10 Monday, July 24, 2006 5:16 PM

Section 2-2

Component Names and Functions

F150-C10E3DRT The F150-C10E-3-DRT can operate as a CompoBus/D Slave. Ground terminal

Power supply Output terminals terminals

Input terminals

POWER indicator Monitor connector

RUN indicator ERROR indicator RS-232C connector

Console connector

MS indicator

NS indicator

10

Camera DIP connector switch

CompoBus/D connector Do not open.

Page 26

Z141-E1-03.book Page 11 Monday, July 24, 2006 5:16 PM

Component Names and Functions

Section 2-2

A POWER Indicator I Output Terminals Lit while power is ON. Wired to external devices, such as synchronous sensors or outputs to B RUN Indicator a Programmable Controller. Lit in RUN mode. J Monitor Connector C ERROR Indicator Connects to the video monitor. Lit when an error occurs. K Console Connector D RS-232C Connector Connects to the Console. Connects the F150 to a computer, Programmable Controller, or other L MS (Module Status) Indicator Indicates the status of the F150 in external device. CompoBus/D communications. Lit E Camera Connector in green when the F150 is operatConnects to the Camera. ing normally. F Power Supply Terminals M NS (Network Status) Indicator Wired to the power supply. Indicates the status of the network G Ground Terminal in CompoBus/D communications. Wired to the ground. Lit in green when the network is opH Input Terminals erating normally. Wired to external devices, such as N DIP Switch synchronous sensors or inputs Used to set the node address and from a Programmable Controller. baud rate. O CompoBus/D Connector Connects the communications cable of the CompoBus/D network.

11

Page 27

Z141-E1-03.book Page 12 Monday, July 24, 2006 5:16 PM

Section 2-3

Connections

2-3

Connections Connect the basic components as shown in the following diagram. Details are provided later in this section.

!Caution Turn OFF the power to the Controller before connecting or disconnecting cables. Connecting or disconnecting cables with power turned ON can damage peripheral devices. If the Two-camera Unit is connected, turn OFF the power to the Two-camera Unit as well as the power to the F150 itself before connecting or disconnecting cables.

12

Page 28

Z141-E1-03.book Page 13 Monday, July 24, 2006 5:16 PM

Section 2-3

Connections Power Supply → p. 14 (OMRON's S82K-01524 and S8VS-06024 recommended.)

F150-KP Console (cable length: 2 m)

F150-VS Camera Cable (3m)

F150-VM Monitor Cable (2 m)

Cameras ✶Camera with Intelligent Light Source (see note1.) → p. 17 F150-SLC20 F150-SLC50 (20-mm field of vision) (50-mm field of vision)

BNC Jack (Monitor cable: Provided with the F150-VM.) Monitors F150-M05L Liquid Crystal Monitor

✶Camera with Light Source (see note 2.) → p. 17 F150-SL20A (20-mm field of vision) ✶F150-S1A Camera F150-SL50A (See note 3.) → p. 17 (50-mm field of vision)

Note

1. An F150-LTC20/LTC50 Intelligent Light Source (with dedicated lens) is attached to the F150-S1A Camera. 2. An F150-LT10A Light Source (with dedicated lens) is attached to the F150-S1A Camera. 3. If the field of vision is too small or too big, use the F150-S1A Camera with a normal CCTV lens and light source. → p. 20

13

Page 29

Z141-E1-03.book Page 14 Monday, July 24, 2006 5:16 PM

Section 2-4

Power Supply and Ground Connecting to Two Cameras To Cameras

F150-A20 Two-camera Unit

Note Use a 24-VDC power supply.

Connection possible to different types of Camera.

F150-VS Camera Cable (3 m)

To F150 Camera Connector

2-4

F150-VA (15 cm) Camera Unit Cable (Provided with Two-camera Unit)

Power Supply and Ground Wire the power supply and the ground to the top terminal block, and tighten the screws to a torque of between 0.5 and 0.6 N⋅m. After wiring, confirm that wiring and screw tightening have been performed properly.

!Caution Cover the terminal blocks with the Terminal Block Protection Covers.

2-4-1

Crimp Terminals and Cables The terminal block uses M3 terminal screws. Use appropriate crimp terminals for M3 screws, as shown below. Forked

6.2 mm max.

14

Round 6.2 mm max.