Manual · Omron
Sensor Controller S3D2
Manual9 pagesPDF 743 KB
Datasheet for the OMRON S3D2 sensor controllers, including the 24 VDC multi-function S3D2-CCD with open collector output and timer.
Covers · 1 model
The models it covers
Summary
What is in it
OMRON datasheet for the S3D2 family of two-input sensor controllers with 0.1 ms input response. It lists the models (AC and 24 VDC, relay or transistor output, with or without timer), ratings and specifications, output and input circuit diagrams, terminal connections, sensor and load wiring, front panel switches and indicators, AND/OR, timer and flip-flop operation charts, safety precautions, mounting rules and dimensions.
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
Omron catalog data sheet for the S3D2 sensor controller family: S3D2-DK, S3D2-EK, S3D2-AK, S3D2-BK, S3D2-CK, S3D2-CC, S3D2-AKD, S3D2-CKD and S3D2-CCD. It gives ordering information, ratings, terminal wiring, switch and indicator functions, timing charts, mounting and wiring precautions, and dimensions.
- Device
- S3D2-CCD: multi-function sensor controller with two inputs and one output, for 24 VDC p. 1, 2
- Power supply
- S3D2-AKD/-CKD/-CCD: 24 VDC on terminals (1) negative and (2) positive p. 3
- Sensor supply terminals
- S3D2-AKD/-CKD/-CCD: +24 V on (7) and (10), 0 V on (9) and (12); sensor outputs to (8) and (11) p. 3
- Input response
- 0.1 ms p. 4
- Connectable sensors
- NPN transistor output sinking 18 mA min., or contact output p. 2
- Timer modes
- S3D2-CK/-CKD/-CC/-CCD: timer on/off switch; one-shot, ON-delay or OFF-delay; set by TIME ADJ. adjuster p. 5
- Logic switches
- AND/OR mode selector, SYNC mode selector, NORM/INV selector for each input p. 5
- Temperature, humidity
- Operating -10 to +55°C, storage -25 to +65°C (no icing); 35% to 85% humidity p. 2
- Size, weight
- 30 mm wide; approx. 140 g p. 1, 2
- Power interruption
- Momentary power failure of 20 ms max. allowed p. 2
- Mounting
- DIN track, or direct with two M4 screws (0.78 N·m max.); terminal block M3.5 screws (0.59 N·m max.) p. 7, 8
- Side-by-side
- At least 10 mm between units; PFP-M End Plate gives the 10 mm space p. 7
- Vibration
- 10 to 55 Hz, 0.75 mm double amplitude, 2 hours each in X, Y and Z p. 2
What this manual walks you through
- Wiring power, sensors and outputs by terminal number p. 3
- Connecting two-wire sensors and wired-OR transistor outputs p. 4
- Connecting loads to the collector or emitter side p. 4
- What each indicator and switch does p. 5
- Setting up AND, OR, timer and flip-flop operation with one or two sensors p. 6
- Mounting units side by side and load derating p. 7
- Removing the terminal block cover p. 8
Good to know
- The controller is not designed or rated for ensuring the safety of persons. p. 7
- S3D2-AKD/-CKD/-CCD: a load of 1 A or more on the sensor power outputs breaks the internal fuse. p. 7
- The timer ignores input signals during the first 50 ms after power is turned on. p. 2
- Because of the 0.1 ms response, contact output sensors may give unwanted inputs from contact bounce. p. 4
- Lay input, output and power lines separately, and keep high-current power lines at least 200 mm away. p. 8
Questions this manual answers
What power supply does the Omron S3D2-CCD need?
24 VDC, with terminal (2) positive and terminal (1) negative. p. 3
Which sensors can be connected to an S3D2?
Sensors with an NPN transistor output that can sink at least 18 mA, or contact outputs; sensors such as the TL-G3D or TL-L100 (2 mA max.) cannot be connected. p. 2, 4
How fast does the S3D2 respond to an input?
The input response is 0.1 ms. p. 4
How much space is needed between S3D2 controllers on a DIN track?
At least 10 mm; the PFP-M End Plate provides that space. If side-by-side mounting cannot be avoided, a load derating curve applies. p. 7
What timer modes does the S3D2-CCD have?
The multi-function models, including the S3D2-CCD, offer one-shot, ON-delay and OFF-delay timer modes. p. 5