Spec sheet · Omron
MC-S Series Compact Coded Magnetic Safety Interlock Switch and Control Unit
Spec sheet7 pagesPDF 526 KB
Data sheet for the Omron STI MC-S Series coded magnetic safety interlock switches and their MC-S1, MC-S2 and MC-S6 control units.
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
Omron STI data sheet for the MC-S Series compact coded magnetic safety interlock switches and control units, used on sliding or swinging guard doors. It explains the operating principle, connector and contact arrangements, mounting and misalignment tolerance, typical wiring with contactors, manual reset and external device monitoring (EDM), electrical, mechanical and environmental specifications, dimensions, and ordering part numbers for control units 1, 2 and 6, switches and actuators.
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Omron STI spec sheet (Rev. 9.10) for the MC-S Series coded magnetic safety interlock switches and the MC-S1, MC-S2 and MC-S6 control units they work with. It gives specifications, connector pinouts, wiring examples, dimensions and ordering part numbers. The designation MC-S024/110/220 is not printed in it; the MC-S2 and MC-S6 control units are listed as 24VAC/DC + 110/220VAC.
- What it is
- Tamper resistant non-contact magnetic safety interlock switch that works with its own control unit p. 1
- Control units
- MC-S1 (24VAC/DC, 1 switch input); MC-S2 (24VAC/DC + 110/220VAC, 1 switch input); MC-S6 (24VAC/DC + 110/220VAC, 6 switch inputs) p. 6
- MC-S6 delayed output
- MC-S6: N/O delayed output, 0.6-30 s; individual monitoring and indication for up to 6 switches p. 1, 4
- Reset and EDM
- External Device Monitoring with automatic or manual reset p. 1
- Switching distance
- Type 1 and Type 3: on 5 mm, off 11 mm; Type 2: on 9 mm, off 12 mm; Type 2 stainless: on 10 mm, off 13 mm p. 4
- Switch wiring
- Pre-wired cable to 10 m on MC-S1 and S2; connector on MC-SS2 and MC-S3 p. 4
- Accessory cables
- 44512-0620 (8-pin female M12); 44512-0600 (4-pin female M12) p. 2
- Type 1 switch part numbers
- MC-S1PC3 Switch & Actuator, 3 m cable: 44531-0100; MC-S1PC10, 10 m cable: 44531-0110 p. 6
- Spare actuators
- Plastic Type 1: 44531-0710; Type 2: 44531-0720; Type 3: 44531-0730; MC-SS2 stainless steel: 44531-0740 p. 6
- Control unit mounting
- 35 mm (1.38 in.) DIN rail p. 4
- Control unit weight
- Control 1: 147 g (5.2 oz.); Control 2: 590 g (21 oz.); Control 6: 990 g (35 oz.) p. 4
- Switch operating temperature
- Plastic: -10 to 55°C (14 to 131°F); stainless: -25 to 125°C (-13 to 257°F) p. 4
- Switch enclosures
- NEMA 6, plastic or stainless steel p. 1
- Standards
- The document states conformance to EN954-1, EN1088, EN60204-1, and UL and C-UL listing p. 1
What this sheet walks you through
- Wiring one sensor and two contactors with manual reset and EDM p. 3
- Wiring three sensors to one control unit p. 3
- Mounting the switch and actuator face to face on a guard door p. 2
- Connector pinouts of the 8-pin and 4-pin M12 switches p. 2
- Ordering control units, switches and spare actuators p. 6
Good to know
- The actuator must not strike the sensor; guard stops are shown. p. 2
- Several sensors on one control unit suit only doors that are always opened and shut one at a time; otherwise some single faults may go undetected. p. 3
- The auxiliary circuit of the switch is not for safety use. p. 2
Questions this sheet answers
What supply voltage does the MC-S2 control unit take?
The ordering table lists the MC-S2 control as 24VAC/DC + 110/220VAC, with one switch input. p. 6
How many MC-S switches can one MC-S6 control unit monitor?
Up to six, each with its own monitoring and indication, plus a N/O delayed output. p. 1
What cable fits the 4-pin M12 MC-S switch?
The accessory cable 44512-0600, a 4-pin female M12 cable. p. 2
What is the part number of a spare plastic Type 2 MC-S actuator?
44531-0720. p. 6
At what distance does a Type 2 MC-S switch turn on and off?
On at 9 mm and off at 12 mm. p. 4
The whole text · 1 part
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.