Manual · Omron
V600 RFID System V600-CD1D-V Serial Interface ID Controller Operation Manual
Manual89 pagesPDF 566 KB
Operation manual for the OMRON V600-CD1D-V serial interface ID controller of the V600 RFID system, including the V600-CD1D-V2.
Covers · 1 model
The models it covers
Summary
What is in it
OMRON operation manual for the V600-CD1D-V series serial interface ID controller used in the V600 RFID system. It explains the features and system layout, the names of parts and dimensions, DIP switch settings, mounting and RS-232C wiring, Data Carrier memory and the command set, testing, diagnostics, error lists, troubleshooting and maintenance. It also compares the V600-CD1D, -V2 and -V3 versions. Appendices give codes, auto read/write use and specifications.
Its parts
- Features and System Configuration
- Nomenclature and Dimensions
- Switch Setting and Wiring
- Communications
- Testing
From the manual
Key facts from this manual
Each line names its page in the PDF.
Operation manual for the Omron V600-CD1D-V serial interface ID controller of the V600 RFID system, covering the V600-CD1D-V2 and V600-CD1D-V3 and how they differ from the earlier V600-CD1D. It explains the switch settings, wiring, host communications, error codes and checks of the data carriers.
- Host interface
- RS-232C, 2,400/4,800/9,600/19,200 bps, line length 15 m max. p. 83
- Power
- 24 VDC (20.4 to 26.4 VDC), 7.2 W max. (24 V, 0.3 A) p. 80
- Power supply
- 24 VDC, 0.6 A minimum; Omron S82K-0124 (100 VAC) or S82K-2124 (200 VAC) p. 28
- Inputs and outputs
- Inputs RESET, TRIG, IN1, IN2; outputs RUN, CMPL, OUT1, OUT2 p. 81
- Input rating
- 24 VDC +10%/–15%, 2.2 kΩ, 10 mA typical, 70 ms max. response p. 81
- Output rating
- 24 VDC (+10%/–15%), 100 mA max. switching capacity p. 28
- Batch data
- Up to 2 KBytes read or written by batch commands p. 11
- Fault codes
- 72 data carrier missing, 7C R/W head not connected, 92 CPU error, 93 memory error p. 61, 62
- Host connector
- XM2A-0901 plug and XM2S-0911 hood supplied; cable 5PX28AWG, 7 dia. p. 29, 83
- Operating temperature
- -10° to 55°C, 35% to 85% RH without condensation p. 80
- Weight
- 360 g p. 80
- Error log
- Records up to 30 error codes, readable by the host p. 61
What this manual walks you through
- Setting baud rate, data format, display mode and trigger with the DIP switches p. 21, 22
- Running the read and write tests with the mode selector switch p. 21
- Wiring power, ground and the RESET input p. 28
- Wiring the RS-232C connection to the host computer p. 29
- Wiring PLC units, sensors and switches to the controller I/O p. 82
- Reading the indicators and error codes p. 61, 62
- Checking the battery of SRAM-type data carriers p. 63
- Counting EEPROM overwrites with the MDL and MDS commands p. 64
- Checking the controller version at power-up p. 83
Good to know
- The RESET input voltage must not exceed 26.4 V or the controller may malfunction. p. 28
- Switch settings are read only at power-on; turn the power off before changing them. p. 22
- Shorting the output terminals without a load may damage the internal transistor. p. 81
- DIP switch 1 SW7 applies only to EEPROM-type data carriers and must be OFF when the V620 is used. p. 22
- The MDS command needs controller version 2.1 or later. p. 12
Questions this manual answers
What power supply does the V600-CD1D-V2 need?
24 VDC (20.4 to 26.4 VDC), drawing 7.2 W max. The manual says to use a supply of 24 VDC, 0.6 A minimum, such as the Omron S82K-0124 or S82K-2124. p. 28, 80
What baud rates does the V600-CD1D-V2 support?
2,400, 4,800, 9,600 or 19,200 bps over RS-232C, chosen with DIP switch 1 SW2 and SW3. p. 22, 83
Can a V600-CD1D-V2 replace a V600-CD1D?
Yes. The manual describes the V2 as an upgraded V600-CD1D with all its functions plus EEPROM-type data carrier support and new data management commands. p. 11, 12
What does error code 72 mean on the V600 ID controller?
Data carrier missing: no data carrier was in the specified area when the read or write command ran. p. 62
What is the difference between the V600-CD1D-V2 and V600-CD1D-V3?
The manual states that the V3 conforms to EC Directives, while the V2 conforms only to UL and CSA standards. p. 12