Spec sheet · Opto 22
G4 Digital AC Output Modules Data Sheet
Spec sheet5 pagesPDF 695 KB
Data sheet for the Opto 22 G4 digital AC output modules, including the G4OAC5 and G4OAC24, with part numbers and specifications.
Covers · 2 models
The models it covers
Summary
What is in it
Opto 22's data sheet for the G4 digital AC output modules, used to switch AC loads such as relays, solenoids, motor starters, heaters and lamps. It lists the part numbers (G4OAC5, G4OAC5A, G4OAC5A5, G4OAC5MA, G4OAC5AMA, G4OAC15, G4OAC15A, G4OAC24, G4OAC24A) with their output voltage ranges and logic voltages, full electrical and temperature specifications, schematics and dimensions, and a closing page about other Opto 22 products.
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Opto 22 data sheet (Form 0252-060522) for the G4 digital AC output modules G4OAC5, G4OAC5A, G4OAC5A5, G4OAC5MA, G4OAC5AMA, G4OAC15, G4OAC15A, G4OAC24 and G4OAC24A. It gives the part numbers, electrical and temperature specifications, schematics and dimensions, so a reader can pick the module for a given AC load and logic voltage.
- Type
- G4 digital AC output module, equivalent to a normally open SPST contact (Form A) p. 1
- Output voltage
- 12-140 VAC p. 1
- Logic voltage
- G4OAC5: 5 VDC logic; G4OAC24: 24 VDC logic p. 1
- Current rating
- 3 A at 45 °C ambient, 2 A at 70 °C ambient p. 1, 2, 3
- UL motor load
- 1.5 A p. 1
- Isolation
- 4,000 Vrms optical isolation, field side to control side p. 1
- Surge
- Withstands a one-cycle surge of 80 A p. 1
- Switching
- Zero voltage turn-on and zero current turn-off; at most one half cycle (8.3 ms at 60 Hz) p. 1, 2, 3
- Features
- Built-in LED status indicator; removable fuse p. 1
- Temperature
- Operating -30 to +70 °C; storage -30 to +85 °C p. 1, 2, 3
- Minimum load
- 20 mA p. 3
- Line frequency
- 25-65 Hz p. 3
- G4OAC5 logic input
- G4OAC5: logic range 4-8 VDC, pickup 4 VDC, dropout 1 VDC, 12 mA at nominal p. 2
- FM version
- G4OAC5: the data sheet lists an FM-rated version, G4OAC5FM p. 2
What this sheet walks you through
- Choosing a G4 AC output module by load voltage and logic voltage p. 1
- Electrical and temperature specifications of each module p. 2, 3
- Module schematics and dimensions p. 4
Good to know
- Turn-on waits for the zero volt crossing and turn-off for the zero current crossing, up to one half cycle each. p. 2
- The current rating falls from 3 A at 45 °C ambient to 2 A at 70 °C ambient. p. 2
- Commutating dV/dT is snubbed for a 0.5 power factor load. p. 3
Questions this sheet answers
What is the difference between the G4OAC5 and the G4OAC24?
Both switch 12-140 VAC loads; the G4OAC5 takes 5 VDC logic and the G4OAC24 takes 24 VDC logic. p. 1
How much current can a G4 AC output module switch?
3 A at 45 °C ambient and 2 A at 70 °C, with a UL motor load rating of 1.5 A. p. 1, 2
Is the G4OAC5 normally open or normally closed?
Normally open (Form A). Only the G4OAC5A5 in this family is normally closed. p. 1
What can a G4 AC output module drive?
The data sheet names AC relays, solenoids, motor starters, heaters, lamps and indicators as typical loads. p. 1