For the Power-One MAP55-1012

Page 1

Bel Power Solutions MAP55 Series of power supplies provides reliable, tightly-regulated DC power for commercial and industrial systems. Wide-range AC input and full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. The MAP55 utilizes a thermally efficient U-channel chassis design. Other mechanical design innovations include metric and SAE mounting inserts on each mounting surface to provide integration flexibility. Dual-mode connectors provide traditional terminal block connections or popular single row Molex connector mating. Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

RoHS Compliant

Wide Range Input for 110/220 VAC Applications

Meets EN55022, Conducted Class B Limits

Compact Footprint: 6.0 x 3.27 x 1.6 inch (152.4 x 83.1 x 40.6 mm)

Greater than 225000 Hours MTBF

Metric and SAE Mounting Inserts

Page 2

MAP55 Series

2

MODEL8

OUTPUT VOLTAGE

ADJUSTMENT RANGE

MAX OUTPUT CURRENT

PEAK OUTPUT CURRENT1

LINE REGULATION

LOAD REGULATION

RIPPLE & NOISE2

INITIAL SETTING ACCURACY

MAP40-1005G

5V

4.7V to 5.5V

8A

11A

0.2%

±1.5%

1%

5.0V to 5.2V

MAP55-1012G6

12V/15V

11.4V to 15.75V

5.0/4.0A3

5.8/4.7A3

0.2%

±1%

1%

12.0V to 12.2V

MAP55-1024G6

24V/28V

23.5V to 28.5V

2.5/2.2A3

2.9/2.5A3

0.2%

1%

1%

23.8V to 24.2V

MODEL8

OUTPUT VOLTAGE

ADJUSTMENT RANGE

OUTPUT CURRENT

PEAK OUTPUT CURRENT4

LINE REGULATION

LOAD REGULATION

RIPPLE & NOISE2

INITIAL SETTING ACCURACY

MAP55-4000G7

MAP55-4001G7

MAP55-4002G7

MAP55-4003G7

MAP55-4004G7

+5V

4.7V to 5.6V

6A

8A

0.2%

2%

1%

5.0V to 5.2V

+12V

Fixed

3A

5A

0.2%

2%

1%

11.6V to 12.4V

-5V

Fixed

0.5A

1A5

0.5%

2%

1%

-4.8V to -5.2V

-12V

Fixed

0.5A

1A5

0.5%

2%

1%

-11.6V to -12.4V

+5V

4.7V to 5.6V

6A

8A

0.2%

2%

1%

5.0V to 5.2V

+24V

Fixed

1.5A

2.5A

0.2%

2%

1%

23.0V to 24.9V

-12V

Fixed

0.5A

1A5

0.5%

2%

1%

-11.6V to -12.4V

+12V

Fixed

0.5A

1A5

0.5%

2%

1%

11.6V to 12.4V

+5V

4.7V to 5.6V

6A

8A

0.2%

2%

1%

5.0V to 5.2V

+12V

Fixed

3A

5A

0.2%

2%

1%

11.6V to 12.4V

-12V

Fixed

0.5A

1A5

0.5%

2%

1%

-11.6V to -12.4V

5

+12V

Fixed

0.5A

1A

0.5%

2%

1%

11.6V to 12.4V

+5V

4.7V to 5.6V

6A

8A

0.2%

2%

1%

5.0V to 5.2V

+15V

Fixed

2.5A

3.5A

0.2%

2%

1%

14.6V to 15.4V

-5V

Fixed

0.5A

1A5

0.5%

2%

1%

-4.8V to -5.2V

5

-15V

Fixed

0.5A

1A

0.5%

2%

1%

-14.4V to -15.6V

+5V

4.7V to 5.6V

6A

8A

0.2%

2%

1%

5.0V to 5.2V

+24V

Fixed

1.5A

2.5A

0.2%

2%

1%

23.0V to 24.9V

-15V

Fixed

0.5A

1A5

0.5%

2%

1%

-14.5V to -15.5V

+15V

Fixed

0.5A

1A5

0.5%

2%

1%

14.5V to 15.5V

1 Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. 2 Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3 MAP55-1012 output currents are expressed as 12V/15V operation. MAP55-1024 output currents are expressed as 24V/28V operation. 4 Peak loads up to 65 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 65 watts. 5 Maximum load on V3 or V4 could be 1 amp continuous if output V4 or V3 is unloaded. 6 Maximum 60 W with 150LFM (Linear Feet per Minute) air cooling or maximum 50 W with convection cooling. 7 Maximum 55 W with 200LFM (Linear Feet per Minute) air cooling or maximum total output power 45 W at 40°C ambient operating temperature for models with no cover and 40 W for models with cover / convection cooling. 8 Non-G models use lead solder exemption.

tech.support@psbel.com

Page 3

MAP55 Series PARAMETER

3

CONDITIONS / DESCRIPTION

MIN

MAX

UNITS

Input Voltage - AC

Continuous input range

90 175

132 264

VAC

Input Frequency

AC input

47

63

Brown Out Protection

Lowest AC input voltage that regulation is maintained with full rated loads

90

VAC

Hold-up Time

Nominal AC Input Voltage (115VAC), full rated load

20 ms

Input Current

90 VAC (55 W load)

Input Protection

Non-user serviceable internally located AC input line fuse.

Inrush Surge Current

Internally limited by thermistor, Vin = 264 VAC (one cycle), 25°C

Operating Frequency

Switching frequency of power supply (varies with load)

PARAMETER

CONDITIONS / DESCRIPTION

MIN

Full load @ 115 VAC. Varies with distribution of loads among outputs. MAP55-1012 MAP55-1024 MAP40-1005 and all multiple output models, main channel only

0.21 0.11 0.50

Efficiency Minimum Loads

NOM

1.6

22

NOM

Hz

ARMS

38

APK

180 kHz

MAX

UNITS

73% typical Amps

Ripple and Noise

Full load, 20 MHz bandwidth.

Output Power

Continuous output power, all multiple output models. Peak output power (60 s maximum, 10% duty cycle), all multiple output models.

55 65

Watts

Overshoot / Undershoot

Output voltage overshoot/undershoot at turn-on, V1, V2.

1

%

Regulation

Transient Response

See Model Selection Chart

Varies by output. Total regulation includes: line changes from 90132 VAC or 175-264 VAC, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output of multiple output units.)

Turn-on Delay

Time required for initial output voltage stabilization.

Turn-on Rise Time

Time required for output voltage to rise from 10% to 90%. (Nominal rise time for MAP55-1024 is 36 msec.)

PARAMETER Overvoltage Protection

Overload Protection

See Model Selection Chart

1

500

μs

4

Sec

7

CONDITIONS / DESCRIPTION

MIN

MAP40-1005 MAP55-1012 MAP55-1024 Main output only of multiple output units. Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.

5.5 17.5 32.0 5.6

NOM ms

MAX

UNITS

6.8 19.7 36.0 6.8

V

Europe, Middle East +353 61 225 977

North America +1 408 785 5200

© 2016 Bel Power Solutions & Protection

BCD.00564_AD

Asia-Pacific +86 755 298 85888

Page 4

MAP55 Series

4

PARAMETER Agency Approvals Dielectric Withstand Voltage Electromagnetic Interference, Conducted

CONDITIONS / DESCRIPTION

MIN

Approved to the latest edition of the following standards; UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd. Input to Chassis Input to Output (tested by manufacturer only) FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated. EN55022 / CISPR 22 conducted. EN55022 / CISPR 22 radiated.

2121 4242 B B A

Insulation Resistance

Input to output

Leakage Current

Per EN60950, 264 VAC

PARAMETER

CONDITIONS / DESCRIPTION

Altitude Operating Temperature

Operating Non-operating Derate linearly above 50°C by 2.5% per °C to a maximum temperature of 70°C (with 200LFM)

NOM

MAX

VDC Class MΩ

7

MIN

At 100% load: At 50% load:

Storage Temperature

UNITS

NOM

500

μA

MAX

UNITS

0 0

10k 40k 50 70

-40

85

°C

±0.03

%/°C

95

%RH

°C

Temperature Coefficient

0°C to 70°C (after 15 minute warm-up)

Relative Humidity

Non-condensing

Shock

Operating, peak acceleration

20

G

Vibration

Random vibration, 10Hz to 2kHz, 3 axis

6

GRMS

PARAMETER

CONDITIONS / DESCRIPTION

MAX

UNITS

Dimensions Weight

Cover (Option)

±0.02

Feet

5

MIN

NOM

152.4 x 83.1 x 40.6 6.00 x 3.27x 1.6 0.55 1.1 mm in kg lb

152.4 x 83.1 x 45.0 6.00 x 3.27 x 1.77 mm in

Order the cover number 412-59584-G separately. For convection cooled applications, derate output power to 40 watts on multiple output units, 50 watts on MAP55-1012 and MAP55-1024 and 40 watts on MAP40-1005. Dimensions:

CONNECTOR

CONDITIONS / DESCRIPTION

Input & Output Connectors

6-32 screw wire clamps on 0.312" (7.9 mm) centers 0.045" (1.1 mm) square pins on 0.156" (3.4 mm) centers

Matting Connectors

Molex Series 2139, 6442, or 41695

Chassis

0.090" (2.3 mm) aluminum alloy, with clear finish tech.support@psbel.com

Page 5

MAP55 Series

5

Figure 1. Mechanical Drawing

NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.

Europe, Middle East +353 61 225 977

North America +1 408 785 5200

© 2016 Bel Power Solutions & Protection

BCD.00564_AD

Asia-Pacific +86 755 298 85888

Page 6

Mouser Electronics Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Bel Power Solutions: MAP80-4003 MAP55-4000 MAP55-1012 MAP55-1024 MAP55-4002 MAP55-4000G MAP55-4001G MAP551024G MAP55-4004G MAP55-1012G MAP55-4003G