Page 1
Bel Power Solutions MAP55 Series of power supplies provides reliable, tightly-regulated DC power for commercial and industrial systems. Wide-range AC input and full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. The MAP55 utilizes a thermally efficient U-channel chassis design. Other mechanical design innovations include metric and SAE mounting inserts on each mounting surface to provide integration flexibility. Dual-mode connectors provide traditional terminal block connections or popular single row Molex connector mating. Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.
RoHS Compliant
Wide Range Input for 110/220 VAC Applications
Meets EN55022, Conducted Class B Limits
Compact Footprint: 6.0 x 3.27 x 1.6 inch (152.4 x 83.1 x 40.6 mm)
Greater than 225000 Hours MTBF
Metric and SAE Mounting Inserts
Page 2
MAP55 Series
2
MODEL8
OUTPUT VOLTAGE
ADJUSTMENT RANGE
MAX OUTPUT CURRENT
PEAK OUTPUT CURRENT1
LINE REGULATION
LOAD REGULATION
RIPPLE & NOISE2
INITIAL SETTING ACCURACY
MAP40-1005G
5V
4.7V to 5.5V
8A
11A
0.2%
±1.5%
1%
5.0V to 5.2V
MAP55-1012G6
12V/15V
11.4V to 15.75V
5.0/4.0A3
5.8/4.7A3
0.2%
±1%
1%
12.0V to 12.2V
MAP55-1024G6
24V/28V
23.5V to 28.5V
2.5/2.2A3
2.9/2.5A3
0.2%
1%
1%
23.8V to 24.2V
MODEL8
OUTPUT VOLTAGE
ADJUSTMENT RANGE
OUTPUT CURRENT
PEAK OUTPUT CURRENT4
LINE REGULATION
LOAD REGULATION
RIPPLE & NOISE2
INITIAL SETTING ACCURACY
MAP55-4000G7
MAP55-4001G7
MAP55-4002G7
MAP55-4003G7
MAP55-4004G7
+5V
4.7V to 5.6V
6A
8A
0.2%
2%
1%
5.0V to 5.2V
+12V
Fixed
3A
5A
0.2%
2%
1%
11.6V to 12.4V
-5V
Fixed
0.5A
1A5
0.5%
2%
1%
-4.8V to -5.2V
-12V
Fixed
0.5A
1A5
0.5%
2%
1%
-11.6V to -12.4V
+5V
4.7V to 5.6V
6A
8A
0.2%
2%
1%
5.0V to 5.2V
+24V
Fixed
1.5A
2.5A
0.2%
2%
1%
23.0V to 24.9V
-12V
Fixed
0.5A
1A5
0.5%
2%
1%
-11.6V to -12.4V
+12V
Fixed
0.5A
1A5
0.5%
2%
1%
11.6V to 12.4V
+5V
4.7V to 5.6V
6A
8A
0.2%
2%
1%
5.0V to 5.2V
+12V
Fixed
3A
5A
0.2%
2%
1%
11.6V to 12.4V
-12V
Fixed
0.5A
1A5
0.5%
2%
1%
-11.6V to -12.4V
5
+12V
Fixed
0.5A
1A
0.5%
2%
1%
11.6V to 12.4V
+5V
4.7V to 5.6V
6A
8A
0.2%
2%
1%
5.0V to 5.2V
+15V
Fixed
2.5A
3.5A
0.2%
2%
1%
14.6V to 15.4V
-5V
Fixed
0.5A
1A5
0.5%
2%
1%
-4.8V to -5.2V
5
-15V
Fixed
0.5A
1A
0.5%
2%
1%
-14.4V to -15.6V
+5V
4.7V to 5.6V
6A
8A
0.2%
2%
1%
5.0V to 5.2V
+24V
Fixed
1.5A
2.5A
0.2%
2%
1%
23.0V to 24.9V
-15V
Fixed
0.5A
1A5
0.5%
2%
1%
-14.5V to -15.5V
+15V
Fixed
0.5A
1A5
0.5%
2%
1%
14.5V to 15.5V
1 Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. 2 Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3 MAP55-1012 output currents are expressed as 12V/15V operation. MAP55-1024 output currents are expressed as 24V/28V operation. 4 Peak loads up to 65 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 65 watts. 5 Maximum load on V3 or V4 could be 1 amp continuous if output V4 or V3 is unloaded. 6 Maximum 60 W with 150LFM (Linear Feet per Minute) air cooling or maximum 50 W with convection cooling. 7 Maximum 55 W with 200LFM (Linear Feet per Minute) air cooling or maximum total output power 45 W at 40°C ambient operating temperature for models with no cover and 40 W for models with cover / convection cooling. 8 Non-G models use lead solder exemption.
tech.support@psbel.com
Page 3
MAP55 Series PARAMETER
3
CONDITIONS / DESCRIPTION
MIN
MAX
UNITS
Input Voltage - AC
Continuous input range
90 175
132 264
VAC
Input Frequency
AC input
47
63
Brown Out Protection
Lowest AC input voltage that regulation is maintained with full rated loads
90
VAC
Hold-up Time
Nominal AC Input Voltage (115VAC), full rated load
20 ms
Input Current
90 VAC (55 W load)
Input Protection
Non-user serviceable internally located AC input line fuse.
Inrush Surge Current
Internally limited by thermistor, Vin = 264 VAC (one cycle), 25°C
Operating Frequency
Switching frequency of power supply (varies with load)
PARAMETER
CONDITIONS / DESCRIPTION
MIN
Full load @ 115 VAC. Varies with distribution of loads among outputs. MAP55-1012 MAP55-1024 MAP40-1005 and all multiple output models, main channel only
0.21 0.11 0.50
Efficiency Minimum Loads
NOM
1.6
22
NOM
Hz
ARMS
38
APK
180 kHz
MAX
UNITS
73% typical Amps
Ripple and Noise
Full load, 20 MHz bandwidth.
Output Power
Continuous output power, all multiple output models. Peak output power (60 s maximum, 10% duty cycle), all multiple output models.
55 65
Watts
Overshoot / Undershoot
Output voltage overshoot/undershoot at turn-on, V1, V2.
1
%
Regulation
Transient Response
See Model Selection Chart
Varies by output. Total regulation includes: line changes from 90132 VAC or 175-264 VAC, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output of multiple output units.)
Turn-on Delay
Time required for initial output voltage stabilization.
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90%. (Nominal rise time for MAP55-1024 is 36 msec.)
PARAMETER Overvoltage Protection
Overload Protection
See Model Selection Chart
1
500
μs
4
Sec
7
CONDITIONS / DESCRIPTION
MIN
MAP40-1005 MAP55-1012 MAP55-1024 Main output only of multiple output units. Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
5.5 17.5 32.0 5.6
NOM ms
MAX
UNITS
6.8 19.7 36.0 6.8
V
Europe, Middle East +353 61 225 977
North America +1 408 785 5200
© 2016 Bel Power Solutions & Protection
BCD.00564_AD
Asia-Pacific +86 755 298 85888
Page 4
MAP55 Series
4
PARAMETER Agency Approvals Dielectric Withstand Voltage Electromagnetic Interference, Conducted
CONDITIONS / DESCRIPTION
MIN
Approved to the latest edition of the following standards; UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd. Input to Chassis Input to Output (tested by manufacturer only) FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated. EN55022 / CISPR 22 conducted. EN55022 / CISPR 22 radiated.
2121 4242 B B A
Insulation Resistance
Input to output
Leakage Current
Per EN60950, 264 VAC
PARAMETER
CONDITIONS / DESCRIPTION
Altitude Operating Temperature
Operating Non-operating Derate linearly above 50°C by 2.5% per °C to a maximum temperature of 70°C (with 200LFM)
NOM
MAX
VDC Class MΩ
7
MIN
At 100% load: At 50% load:
Storage Temperature
UNITS
NOM
500
μA
MAX
UNITS
0 0
10k 40k 50 70
-40
85
°C
±0.03
%/°C
95
%RH
°C
Temperature Coefficient
0°C to 70°C (after 15 minute warm-up)
Relative Humidity
Non-condensing
Shock
Operating, peak acceleration
20
G
Vibration
Random vibration, 10Hz to 2kHz, 3 axis
6
GRMS
PARAMETER
CONDITIONS / DESCRIPTION
MAX
UNITS
Dimensions Weight
Cover (Option)
±0.02
Feet
5
MIN
NOM
152.4 x 83.1 x 40.6 6.00 x 3.27x 1.6 0.55 1.1 mm in kg lb
152.4 x 83.1 x 45.0 6.00 x 3.27 x 1.77 mm in
Order the cover number 412-59584-G separately. For convection cooled applications, derate output power to 40 watts on multiple output units, 50 watts on MAP55-1012 and MAP55-1024 and 40 watts on MAP40-1005. Dimensions:
CONNECTOR
CONDITIONS / DESCRIPTION
Input & Output Connectors
6-32 screw wire clamps on 0.312" (7.9 mm) centers 0.045" (1.1 mm) square pins on 0.156" (3.4 mm) centers
Matting Connectors
Molex Series 2139, 6442, or 41695
Chassis
0.090" (2.3 mm) aluminum alloy, with clear finish tech.support@psbel.com
Page 5
MAP55 Series
5
Figure 1. Mechanical Drawing
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.
Europe, Middle East +353 61 225 977
North America +1 408 785 5200
© 2016 Bel Power Solutions & Protection
BCD.00564_AD
Asia-Pacific +86 755 298 85888
Page 6
Mouser Electronics Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Bel Power Solutions: MAP80-4003 MAP55-4000 MAP55-1012 MAP55-1024 MAP55-4002 MAP55-4000G MAP55-4001G MAP551024G MAP55-4004G MAP55-1012G MAP55-4003G