For the Power-One PFC375-4000

Page 1

The PFC375 products of the PerFormanCe Power Series incorporate high performance midrange power, active Power Factor Correction (PFC), and high reliability to meet varied commercial and industrial requirements. Providing tightly-regulated DC power in a wide variety of single and multiple output configurations, the PFC375 is designed to provide full output power with only 300 Linear Feet per Minute (LFM) forced-air cooling (factory installed fan optional). Other features include remote sense, power fail, logic level inhibit, and DC power good. Main channel current sharing is provided for redundant applications. The PFC375 is available with SAE mountings or optional metric mountings. The PFC375 product line is approved to the latest international regulatory standards and displays the CE Mark.

RoHS Compliant

Greater than 1 million hours demonstrated MTBF

Power Factor Correction (PFC) meets EN61000-3-2

Fully-regulated outputs

Main output remote sense

Current Share, Power Fail, and Power Good signals

Overtemperature, overvoltage, and overcurrent protected

Available with metric and SAE mountings

Input transient & ESD compliance to EN61000-4-2/-3/-4/-5

Fan output voltage and optional fan

Asia-Pacific +86 755 298 85888

Europe, Middle East +353 61 225 977

© 2015 Bel Power Solutions, Inc.

North America +1 866 513 2839

BCD.00594_AB

Page 2

2

MODEL

OUTPUT VOLTAGE

ADJUSTMENT RANGE

MAX. OUTPUT CURRENT 1

LINE REGULATION

LOAD REGULATION

RIPPLE & NOISE % p-p 2

INITIAL SETTING ACCURACY

PFC375-1012G

12V

10.8V to 13.5V

30A

0.2%

0.8%

1%

11.94V to 12.06V

PFC375-1015G

15V

12.0V to 17.0V

25A

0.2%

0.6%

1%

14.94V to 15.06V

PFC375-1024G

24V

21.6V to 26.4V

15A

0.5%

0.8%

1%

23.88V to 24.12V

PFC375-1028G

28V

25.2V to 30.8V

13.4A

0.5%

0.9%

0.9%

27.86V to 28.14V

PFC375-1048FG

48V

46.0V to 56.0V

7.8A

0.5%

1.0%

1%

47.52V to 48.48V

NOTES: 1

Output currents ratings are expressed with 300 LFM forced air. Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3 Models without suffix G use the lead solder exemption Ooo Model numbers highlighted in yellow are not recommended for new designs or EOL. 2

Isolated V3 and V4 Can Be Used as Positive Or Negative Output MODEL

OUTPUT VOLTAGE

ADJUSTMENT RANGE

OUTPUT PEAK OUTPUT CURRENT1 CURRENT3

LINE REGULATION

+5V

4.5V to 5.5V

3.5 - 40A

40A

0.4%

+12V

11.3V to 12.6V

10A

16A

12V

11.3V to 12.6V

6A

6A

LOAD REGULATION

RIPPLE & NOISE % p-p2

INITIAL SETTING ACCURACY

0.8%

1%

4.98V to 5.02V

0.9%

0.9%

1%

11.9V to 12.1V

0.9%

0.9%

1%

11.9V to 12.1V

PFC375-4000G

PFC375-4001G4

PFC375-4002G5

PFC375-4004G

PFC375-4005G6

PFC375-4200G

5V

Fixed

3A

3A

2%

2%

2.4%

4.9V to 5.1V

+5V

4.5V to 5.5V

3.5 - 40A

40A

0.4%

0.8%

1%

4.98V to 5.02V

+12V

11.3V to 12.6V

10A

16A

0.9%

0.9%

1%

11.9V to 12.1V

12V

11.3V to 12.6V

6A

6A

0.9%

0.9%

1%

11.9V to 12.1V

12V

11.0V to 15.8V

3A

3A

0.9%

0.9%

1%

11.9V to 12.1V

+5V

4.5V to 5.5V

3.5 - 40A

40A

0.4%

0.8%

1%

4.98V to 5.02V

+12V

11.3V to 12.6V

10A

16A

0.9%

0.9%

1%

11.9V to 12.1V

12V

11.3V to 12.6V

6A

6A

0.9%

0.9%

1%

11.9V to 12.1V

24V

22.0V to 28.0V

3A

3A

0.5%

0.8%

1%

23.8V to 24.2V

+5V

4.5V to 5.5V

3.5 - 40A

40A

0.4%

0.8%

1%

4.98V to 5.02V

+12V

11.3V to 12.6V

10A

16A

0.9%

0.9%

1%

11.9V to 12.1V

15V

14.2V to 15.8V

4A

4A

0.7%

0.7%

1%

14.9V to 15.1V

15V

14.2V to 15.8V

4A

4A

0.7%

0.7%

1%

14.9V to 15.1V

+5V

4.5V to 5.5V

3.5 - 40A

40A

0.4%

0.8%

1%

4.98V to 5.02V

+12V

11.3V to 12.6V

10A

16A

0.9%

0.9%

1%

11.9V to 12.1V

24V

22.0V to 28.0V

3A

3A

0.5%

0.8%

1%

23.8V to 24.2V

24V

22.0V to 28.0V

3A

3A

0.5%

0.8%

1%

23.8V to 24.2V

+24V

21.5V to 26.4V

1 - 10A

10A

0.5%

0.8%

1%

23.8V to 24.2V

+5V

4.5V to 5.5V

10A

16A

0.4%

0.8%

1%

4.98V to 5.02V

12V

11.4V to 12.6V

4A

4A

0.5%

1%

1%

11.9V to 12.1V

12V

11.4V to 12.6V

4A

4A

0.5%

1%

1%

11.9V to 12.1V tech.support@psbel.com

Page 3

3

PFC375-4201G

PFC375-4500G

+24V

21.5V to 26.4V

1 - 10A

10A

0.5%

0.8%

1%

23.8V to 24.2V

+5V

4.5V to 5.5V

10A

16A

0.4%

0.8%

1%

4.98V to 5.02V

15V

14.2V to 16.0V

4A

4A

0.5%

0.8%

1%

14.9V to 15.1V

15V

13.7V to 16.0V

4A

4A

0.5%

0.8%

1%

14.9V to 15.1V

+5V

4.5V to 5.5V

3.5 - 50A

50A

0.4%

0.8%

1%

4.98V to 5.02V

+12V

11.3V to 12.6V

10A

16A

0.9%

0.9%

1%

11.9V to 12.1V

12V

11.3V to 12.6V

6A

6A

0.9%

0.9%

1%

11.9V to 12.1V

5V

4.5V to 5.5V

3A

3A

2%

0.9%

1%

4.9V to 5.1V

NOTES: 1

Output currents ratings are expressed with 300 LFM forced air. Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3 Peak loads up to 450 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 450 Watts. 4 V4 can be adjusted to 16 V with a minimum load of 5 A on V1. 5 For operation of V4 greater than 24 V, consult factory. 6 V3 and V4 may be series connected to obtain 48 V. 7 Models without suffix G use the lead solder exemption Ooo Model numbers highlighted in yellow are not recommended for new designs or EOL 2

PARAMETER

CONDITIONS / DESCRIPTION

MIN

Input Voltage - AC

Continuous input range.

Input Frequency

AC Input.

Brown Out Protection

Lowest AC input voltage that regulation is maintained with full rated loads.

85

VAC

Hold-Up Time

Over full AC input voltage range at full rated load.

20 ms

Input Current

85 VAC at full rated load.

6

ARMS

Non-user serviceable internally located AC input line fuse, F10A, 250V. 110 VAC Internally limited by thermistor, one cycle, 25°C. 220 VAC

35 65

APK

Input Protection Inrush Surge Current Power Factor

Per EN61000-3-2.

Operating Frequency

Switching frequency of main transformer.

PARAMETER

CONDITIONS / DESCRIPTION Full rated load, 110 VAC. Varies with distribution of loads among outputs. Single output models. Multiple output models, 5V main output only. Multiple output models, 24V main output only. Full load, 20MHz bandwidth. 300 LFM forced air cooling required for operation. See optional fan. Continuous power, multiple output models. Peak power, all models. Output voltage overshoot/undershoot at turn-on. Varies by output. Total regulation includes: line changes from 85132 VAC or 170-264 VAC, changes in load starting at 20% load and changing to 100% load.

Efficiency Minimum Loads Ripple and Noise Output Power Overshoot / Undershoot Regulation

NOM

MAX

UNITS

85

264

VAC

47

63

Hz

0.98

W/VA 100

MIN

NOM kHz

MAX

68

UNITS %

0 3.5 Amps 1 See Model Selection Charts 375 450 0

Watts V

See Model Selection Charts tech.support@psbel.com

Page 4

4

Turn-On Delay

Recovery time, to within 1% of initial set point due to a 50-100% load change, 3% max. deviation. (Main output only on multi-output units). Time required for initial output voltage stabilization.

Turn-On Rise Time

Time required for output voltage to rise from 10% to 90%.

Transient Response

PARAMETER

Overvoltage Protection

Overload Protection

1 ms 1

10

CONDITIONS / DESCRIPTION

MIN

Provided on single output units and the main output only of multiple output units. PFC375-30XXG, PFC375-40XXG, PFC375-45XXG PFC375-1012G PFC375-1015G PFC375-1024G PFC375-1028G PFC375-1048G PFC375-42XXG Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.

6.0 13.5 17.0 27.0 30.8 60.0 27.0

NOM

Sec ms

MAX

6.4 15.5 19.5 30.7 35.0 70.0 30.7

UNITS

V

Overtemperature Protection

System shutdown due to excessive internal temperature, automatic reset.

Remote Sense

Total voltage compensation for cable losses with respect to the main output.

250 mV

Current Share

Accuracy of shared current with up to 6 parallel units.

10

%

Inhibit Input Power Fail Warning Power Good Fan Voltage

TTL compatible logic signal will inhibit outputs by the application of a logic low signal. An open circuit or external TTL high signal allows normal operation. TTL compatible logic signal. Time before regulation dropout due to 5 loss of input power at 110 VAC. TTL compatible signal. Signal is low if main output is greater or less than 10% of nominal. Provides 170 mA current to user-supplied fan, if fan option is not selected.

PARAMETER

CONDITIONS / DESCRIPTION

Agency Approvals

Approved to the latest edition of the following standards. UL/CSA60950-1, EN60950-1 and IEC60950-1

Dielectric Withstand Voltage Electromagnetic Interference

5

12

MIN

Input to Output per EN60950.

ms

NOM

V

MAX

UNITS

Approved 2600

VDC

FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted.

B B

Class

ESD Susceptibility

Per EN61000-4-2, level 4.

8 kV

Radiated Susceptibility

Per EN61000-4-3, level 3.

10

V/M

EFT/Burst

Per EN61000-4-4, level 4.

±4 kV

1 2 kV

Input Transient Protection

Per EN61000-4-5 level 3.

Insulation Resistance

Input-to-Output.

Leakage Current

Per EN60950, 264 VAC.

Line-to-Line Line-to-Ground

10

M 2.0 mA tech.support@psbel.com

Page 5

5

PARAMETER

CONDITIONS / DESCRIPTION

Altitude

Operating. Non-Operating.

Operating Temperature

Derate linearly above 50°C by 2.5% per °C.

MIN

At 100% load: At 50% load:

Storage Temperature

Forced Air Cooling

Forced air cooling of 300 LFM is required if the internal fan option is not specified. Cooling air velocity is measured 1/4" above, at the middle of the chassis. Airflow direction is from the input section to the output section.

Temperature Coefficient

0°C to 70°C (after 15 minute warmup).

Relative Humidity

Non-Condensing.

Shock Vibration

PARAMETER

CONDITIONS / DESCRIPTION

Dimensions Overall Length With Fan Weight

Metric Mounting Fan

MAX

CONDITIONS / DESCRIPTION Add “M” as a suffix to the model number to order chassis with M4 x 0.7 mounting inserts. Add “F” as a suffix to the model number to order integral fan. (Provides required 300 LFM of forced air cooling).

UNITS

0 0

10k 40k 50 70

-55

85

°C

± 0.05

%/°C

95

%RH

± 0.02 5

Operating: 10±3mS, 3 axis, Halfsine. 20 G Non-operating: 10±3mS, 3 axis, Halfsine. Operating: 5-32 Hz 32-2000 Hz Sinusoidal Non-operating:

Overall Size

PARAMETER

NOM

MIN

NOM

NOM

°C

20 40 0.02 1 6.15 in (DA) GRMS GRMS

MAX

UNITS

228.6 x 127.0 x 63.5 9.00 x 5.00 x 2.50 266.7 10.50 1.95 4.3

MIN

ASL Ft.

MAX

228.6 x 127.0 x 63.5 9.00 x 5.00 x 2.50 266.7 x 127.0 x 63.5 10.50 x 5.00 x 2.50

G mm in mm in kg lb

UNITS mm in mm in

6-32 Screw Terminal on 0.375" (9.5mm) Centers Bus Bar Main Output, E1 & E2, 10-32 Screw Terminal Chassis: 0.090" (2.3mm) Aluminum Alloy, With Clear Finish TERMINAL BLOCKS have 6-32 (PHILSLOT) screw connections on 0.375" (9.53mm) centers; open space clearance for connections is 0.31" (7.87mm).

tech.support@psbel.com

Page 6

6

Figure 1. Mechanical Drawing PFC375

NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.

tech.support@psbel.com

Page 7

Mouser Electronics Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Bel Power Solutions: PFC375-1012 PFC375-4000 PFC375-4002 PFC375-4201 PFC375-1048F PFC375-4201FG PFC375-4201G PFC375-1024FMG PFC375-1024G PFC375-4000G PFC375-1048FG PFC375-4200FG PFC375-4000FG PFC3754002G PFC375-1012G PFC375-4200G PFC375-1024FG