Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Power Source FHG24SXU Spec Sheet

Spec sheet · Power Source

Power Source FHG24SXU Spec Sheet

Spec sheet2 pagesPDF 741 KB

Both pages are below, each with its text.

Download the PDF741 KB

Covers · 1 model

The models it covers

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

A two-page specification sheet from ETA-USA for the FHG-SX-U series of 600W switching power supplies with power factor correction. It covers the models FHG 3.3SX-U through FHG 48SX-U, including the FHG 24SX-U. It lets a reader check input, output, protection, environmental and size data.

Device
600W switching power supply with power factor correction p. 1
AC input
115VAC~230VAC nominal, 85~264VAC range, 50/60Hz, single phase p. 2
Input current
7.5 / 4A at full load (115V / 230VAC input) p. 2
Inrush current
17A max. at 115VAC, 33A max. at 230VAC p. 2
Power factor
0.99 at 115VAC, 0.97 at 230VAC p. 1
Output adjustment
± 10%, typical p. 2
Ripple and noise
(Output V x 1%) + 100mVp-p max. p. 2
Hold-up time
20mS min. at 25°C, rated input and output p. 2
Protection
Over-current by constant current limiting; over-voltage by output shutdown p. 2
Remote functions
Remote control and remote sensing possible p. 2
Dimensions
130X200X93 (mm) p. 1
Weight
2.6Kg p. 2
Temperature
Operating -5 ~ +50° C (see derating curve); storage -20~+85°C p. 2
Switching frequency
130KHz fixed p. 2

What this sheet walks you through

  • Choosing a model by output voltage p. 1
  • Input, output and general specifications p. 2
  • Block diagram and terminal connection drawings p. 2

Good to know

  • Operating temperature is subject to the output derating curve. p. 2
  • All specifications and data are subject to change without notice. p. 1

Questions this sheet answers

What input voltage does the FHG 24SX-U accept?

The FHG-SX-U series takes 85~264VAC at 50/60Hz, single phase, with 115VAC~230VAC nominal. p. 2

How much power does the FHG-SX-U series supply?

The sheet describes them as 600W switching power supplies with power factor correction. p. 1

How big and heavy is the FHG-SX-U power supply?

The sheet gives 130X200X93 (mm) and a weight of 2.6Kg. p. 1, 2

Can the FHG-SX-U output voltage be adjusted?

Yes, the output is adjustable by ± 10%, typical. p. 2

The file

Size and text

Pages2
PDF741 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Power Source FHG24SXU Spec Sheet

The text of page 1, from the PDF itself

ETA-USA

600W

High Quality Switching Power Supplies

85-264VAC

Power - Factor Correction

FHG-SX-U1SERIESOutput TableFHG-SX-U (85~264V)MODEL(CSA)Load & Output V.O utput Derating130X200X93 (mm )OUTPUT VOLTAGE CURRENT

FHG 3.3SX-U FHG 05SX-U FHG 06SX-U FHG 12SX-U FHG 15SX-U FHG 24SX-U FHG 30SX-U FHG 36SX-U FHG 48SX-U

3.3V 5V 6V 12V 15V 24V 30V 36V 48V

120A 120A 100A 53A 42A 27A 21.6A 18A 13.5A

EFFICIENCY 70% 75% 81% 81% 81% 83% 84% 83% 84%

FHG-Series is a new generation of powersupplies. Its the latest design following the international standard and market demands. This type of powersupply has all in one : Power factor correction, low line distortion according to EN 60555-2, electro magnetic interference (EMI) complies with EN 55022/B, FCC level B. Safety complies with EN 60950-1 , UL 1950, CSA 234. High efficiency and power fac tor correction is an optimal combination of good costparformance for both, end-users and power production companies.

Special Features 1. Power factor 115VAC=0.99 230VAC=0.97 2. Harmonics : EN 60555-2 IEC1000-3-2 3. EMI: complies to EN 55022/13, FCC/B 4. Safety: UL1950, C-UL(CSA950), EN60950-1, VDE0805, IEC950 approved CE marked to the low voltage directive

Applications All specifications and data subject to change without notice

Process control, Office-Equipment, Computer Peripherals, Telecommunication, Industrial Electronics and Machines, Household Equipment.

Page 2 of Power Source FHG24SXU Spec Sheet

The text of page 2, from the PDF itself

FHG-SX-U SPECIFICATION I N PUT

G EN ERAL S PECIFICATIO N Power factor correction Over-current protection Over-voltage protection Remote control Remote sensing Switching frequency Withstand voltage Insulation resistance Leakage current Weight

:Active filter circuit with boost converter :Constant current limiting :Output shutdown :Possible :Possible :130KHz Fixed :(Input-Output) :AC3000V(1Minute) :(Input-Chassis) :AC2500V (1Minute) :(Output-Chassis) :AC 500V (1Minute) :(Input-Output-Chassis):50M MIN. :AC 115VAC, 50Hz, 25°C 0.28mA AC 230VAC, 50Hz, 25°C 0.58mA :2.6Kg

E N VIRO N M EN T Operating temperature Storage temperature Humidity Vibration

Shock

:-5 ~+50° C (See output derating curve) :-20~+85°C :85% :(5~10Hz) Amplitude (peak to peak) 10mm(constant) :(10~55Hz) Acceleraton 2G (constant) X, Y, Z :30G

Dimension (mm)

Voltage nominal Voltage range Power factor & harmonic correction range Frequency Current on full road Inrush current Phase

:115VAC~230VAC :85~264VAC :85~255VAC :50/60Hz :7.5 / 4A(Input 115V/AC230VAC) :17A MAX.(Input 115VAC), 33A MAX. (Input 230VAC) :Single

O UTPUT Adjustable voltage Ripple & noise Input regulation Load regulation Temperature coefficient Drift / Time effect Rise up time Hold-up time

:± 10%, typical :(Output V x 1%) + 100mVp-p MAX. :0.5%MAX :1.0%MAX :0.03% / °C :(Output V X 0.5%)+15mV/8H (After 1 H) :500mS typ. @ 115 VAC in / 200mS typ. @230 VAC in :20mS MIN (at 25°C, Rated-InputOutput)

B lock DiagramTerminal ConnectionETA-USA

16315 Vineyard Blvd. Morgan Hill, CA 95037 Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753

Visit Us On The Web at: Or Email at:

http://www.eta-usa.com/ sales@eta-usa.com