Page 1
TM-1020 Series Progressive Scan Shutter Cameras Operation Manual
69-0076 Rev. B
Imaging Products
Page 2
Page 3
Notice The material contained in this manual consists of information that is proprietary to PULNiX America, Inc., and may only be used by the purchasers of the product. PULNiX America, Inc. makes no warranty for the use of its product and assumes no responsibility for any errors which may appear or for damages resulting from the use of the information contained herein. PULNiX America, Inc. reserves the right to make changes without notice. Microsoft, Windows 98, Windows 95, Windows NT, and Windows Explorer are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
Warranty All of our solid-state cameras have a full three-year warranty. If any such product proves defective during this warranty period, PULNiX America, Inc. will repair the defective product without charge for parts and labor or will provide a replacement in exchange for the defective product. This warranty shall not apply to any damage, defect or failure caused by improper use or inadequate maintenance and use.
Certifications CE Compliance The TM-1020 series cameras have been certified to conform to the requirements of Council Directive 89/336/EC for electromagnetic compatibility and to comply with the following European Standards: Immunity: Emissions:
EN50082-2/1995 EN55011/EN61326-1, Class A
All PULNiX products bearing the CE mark have been declared to be in conformance with the applicable EEC Council Directives. However, certain factory-installed options or customer-requested modifications may compromise electromagnetic compatibility and prohibit use of the CE mark. Please note that the use of interconnect cables that are not properly grounded and shielded may affect CE compliance. Contact PULNiX Applications Engineering Department for further information regarding CE compliance. FCC This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
WARNING
I
S
UL ®
FI
REG
TM-1020 Series Operation Manual Printing:June 10, 2003 PULNiX America, Inc. 1330 Orleans Drive Sunnyvale, CA 94089 Tel:(408) 747-0300 Tel:(800) 445-5444 Fax:(408) 747-0880 E-mail: imaging@pulnix.com www.pulnix.com
RM
Changes or modifications to this unit not expressly approved by the party responsible for FCC compliance could void the user’s authority to operate the equipment.
TE ED R
PULNiX AMERICA, INC. REGISTERED TO ISO-9001 FILE #A3942
TM-1020 Series progressive Scan Shutter Cameras
Page 4
Page 5
i Table of Contents
1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 1.2 1.3 1.4
Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Functional Options . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 System Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.1
Getting Started. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.1.1 2.1.2 2.1.3
2.2
Unpacking Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Components List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Accessories and Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Camera Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.2.1 2.2.2 2.2.3 2.2.4 2.2.5 2.2.6 2.2.7 2.2.8 2.2.9
Heat Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Connector Pin Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Shutter Speed Control Dial (LVDS/RS-422 version) . . . . . . . . . . . . 10 RS-232 Communication Cable (LVDS/RS-422 version) . . . . . . . . . . 10 Digital Output Cable (LVDS/RS-422 version) . . . . . . . . . . . . . . . . . 11 Camera Link Cable (CL Versions Only) . . . . . . . . . . . . . . . . . . . . . . 11 Power Supplies and Power Cable Setup. . . . . . . . . . . . . . . . . . . . . . 13 Attaching the Analog Video Output . . . . . . . . . . . . . . . . . . . . . . . . . 15 Attaching the Camera Lens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.1
Camera Rear Panel (LVDS/RS-422 Version). . . . . . . . . . . 16 3.1.1 3.1.2 3.1.3 3.1.4 3.1.5 3.1.6
3.2
Camera Rear Panel (CL Versions) . . . . . . . . . . . . . . . . . 18 3.2.1 3.2.2 3.2.3
3.3 3.4 3.5 3.6
Up/Down Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Digital Output Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Analog Output Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Power, RS-232, and External Sync Connector . . . . . . . . . . . . . . . . . 16 Shutter Speed Control Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Mode Selection Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Digital Output Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Analog Output Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Power and External Sync Connector . . . . . . . . . . . . . . . . . . . . . . . . 18
Progressive Scanning . . . . . . . . . . . . . . . . . . . . . . . . . 18 Electronic Shutter . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Integration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Asynchronous Reset . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.6.1 3.6.2
Internal Shutter Speed Control (TM-1020 Series) . . . . . . . . . . . . . 21 External VINIT With Pulse Width No-Delay Shutter and ROI (Read-out Inhibit) (TM-1020 Series) . . . . . . . . . . . . 21 3.6.3 Internal Shutter Speed with Fast Mode (TM-1020-15 only) . . . . . . 23 3.6.4 Internal Shutter Speed with Slow Mode (TM-1020-15 Only) . . . . . 24 3.6.5 External VINIT with Pulse Width (TM-1020-15 Only). . . . . . . . . . . 25
3.7
Dynamic Range Control . . . . . . . . . . . . . . . . . . . . . . . 26 3.7.1
3.8
3.8.1 3.8.2
3.9
Programmable Look-Up Table (LUT) and Knee Control. . . . . . . . . 26
Scan Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Full Progressive Scan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Two-Row Binning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
External Sync and Pixel Locking . . . . . . . . . . . . . . . . . 28 TM-1020 Series Progressive Scan Shutter Cameras
Page 6
ii Table of Contents 3.10 Camera Timing Charts . . . . . . . . . . . . . . . . . . . . . . . . 29 3.10.1
Pixel Clock Locking (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.11 Serial Communication Kit. . . . . . . . . . . . . . . . . . . . . . 33
4 LVDS-Version Camera RS-232 Commands . . . . . . . . . 34 5 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . 36 5.1
Problems and Solutions . . . . . . . . . . . . . . . . . . . . . . . 36 5.1.1 5.1.2 5.1.3
5.2
Symptom: No Video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Symptom: Dark Video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Symptom: Non-synchronized Video . . . . . . . . . . . . . . . . . . . . . . . . . 36
Information and Support Resources . . . . . . . . . . . . . . 37
6 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 6.1
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 6.1.1 6.1.2
TM-1020 Series Physical Dimensions. . . . . . . . . . . . . . . . . . . . . . . . 40 Spectral Response. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
TM-1020 Series Progressive Scan Shutter Cameras
Page 7
iii List of Tables TABLE 1.
12-Pin Connector (TM-1020-15) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
TABLE 2.
12-Pin Connector (CL Version) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
TABLE 3.
31-Pin Connector (MP211-031-113-4300). . . . . . . . . . . . . . . . . . . . . . . . . . 8
TABLE 4.
Connector and Pinout Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
TABLE 5.
Shutter Speed Control Dial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
TABLE 6.
Mode Selection Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
TABLE 7.
RS-232 Command List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
TABLE 8.
TM-1020 Series Camera Specifications Table . . . . . . . . . . . . . . . . . . . . . . . 35
TM-1020 Series Progressive Scan Shutter Cameras
Page 8
iv List of Figures FIGURE 1.
TM-1020 Series System Configuration. . . . . . . . . . . . . . . . . . . . . . 4
FIGURE 2.
CL (Camera Link) System Configuration . . . . . . . . . . . . . . . . . . . . 4
FIGURE 3.
Rear Panel View of Digital Connector . . . . . . . . . . . . . . . . . . . . . . 8
FIGURE 4.
Serial Communication Cable RS-232B-12 . . . . . . . . . . . . . . . . . . 10
FIGURE 5.
Digital Output Cable 30DG-02 . . . . . . . . . . . . . . . . . . . . . . . . . . 11
FIGURE 6.
Pin-out Configuration for Digital Output Cable . . . . . . . . . . . . . 11
FIGURE 7.
3M Camera Link Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
FIGURE 8.
12P-02S Interface Cable (optional). . . . . . . . . . . . . . . . . . . . . . . . 14
FIGURE 9.
Internal Shutter Speed Control (TM-1020 Series). . . . . . . . . . . . 21
FIGURE 10.
No-Delay Shutter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
FIGURE 11.
No-Delay Shutter and Read-Out Inhibit . . . . . . . . . . . . . . . . . . . 22
FIGURE 12.
Internal Shutter Speed with Fast Mode (TM-1020-15 only) . . . . 23
FIGURE 13.
Internal Shutter Speed with Slow Mode (TM-1020-15 Only) . . . 24
FIGURE 14.
External VINIT with Pulse Width (TM-1020-15 Only). . . . . . . . . 25
FIGURE 15.
Look-Up Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
FIGURE 16.
Scan Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
FIGURE 17.
Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
FIGURE 18.
Spectral Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
TM-1020 Series Progressive Scan Shutter Cameras
Page 9
June 10, 2003
TM-1020 Series Progressive Scan Shutter Cameras Operation Manual
1
Introduction 1.1 Product Description The PULNiX TM-1020 series1 consists of high-resolution, high-speed monochrome progressive scan CCD cameras. The interline-type CCD permits full vertical and horizontal resolution of very high speed shutter images and applications. The electronic shutter, which has speeds to 1/16,000 sec., can be reset asynchronously by external pulse control. The base model’s frame rate is 15 fps. A square imager format with uniform square pixels provides superior image definition in any orientation. On-chip micro lenses provide increased sensitivity. The TM-1020 series has a full dynamic range control function, which can be set at externally selectable look-up table (LUT) knee slopes to convert 10-bit input to 8-bit output, thereby optimizing the CCD’s full dynamic range in the normal output signal range. The camera has an 8-bit, RS-422 or RS-644 digital signal output for interfacing with external image-processing systems. All the key functions are externally controlled via RS-232C. The CL models have a Camera Link output. Multi-camera operation requires synchronized data and clock phases from each camera. The TM-1020 series has a pixel clock locking phase lock loop (PLL) for multi-camera operation that is offered as an option. 2 Applications for the TM-1020 series include machine vision, medical imaging, intelligent transportation systems, high-definition graphics, on-line inspection, gauging, character reading, archiving, and high-security surveillance. 1. Unless specifically mentioned, all information in this manual is relevant to all released cameras in the TM-1020 series, including TM-1020-15, TM-1020A and all variations, Camera Link versions (CL), FW version, and the TM-1020-30 and CL. 2. Pixel clock locking option not available at time of publishing. Please check with PULNiX for option availability.
TM-1020 Series Progressive Scan Shutter Cameras