Page 19

Page 11 Installation 2.2.5 Digital Output Cable (LVDS/RS-422 version) FIGURE 5.

Digital Output Cable 30DG-02 Male

Female 17

1

31

16 25.0mm 1.00 in

20

1

37

19

78.74 in (2 meters)

The TM-1020 series camera uses the cable 30DG-02 from PULNiX as a digital output cable. This cable has a 31-pin AirBorn connector on the camera end and a 37-pin D-sub male connector on the other end. Contact your PULNiX representative regarding availability of interface cables for specific frame grabber models. Pin-out configuration for the digital cable is shown below. FIGURE 6.

Pin-out Configuration for Digital Output Cable

FROM 31 PIN CONN

TO 37 PIN CONN

WIRE COLOR

FROM 31 PIN CONN)

PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 PIN 9 PIN 10 PIN 11 PIN 12 PIN 13 PIN 14 PIN 15 PIN 16 PIN 17 PIN 18 PIN 19 PIN 20

PIN 1 PIN 2 PIN 3 PIN 16 GND

PIN 8 PIN 9 PIN 10 PIN 11 PIN 12 PIN 13 PIN 14 PIN 15

OR GRY WHT YLW PINK OR GRY WHT YLW PINK OR GRY WHT YEL PINK

1RED 1RED 1RED 1RED 1RED 2RED 2RED 2RED 2RED 2RED 3RED 3RED 3RED 3RED 3RED

PIN 21 VD PIN 22 EN/INTEG PIN 23 GND PIN 24 PIN 25 PIN 26 PIN 27 PIN 28 PIN 29 PIN 30 PIN 31

PIN 20 PIN 21 PIN 22 PIN 17

OR GRY WHT YEL

1BLU 1BLU 1BLU 1BLU

GND HD INTEG PULSE

TO 37 PIN CONN

WIRE COLOR

PIN 23 GND PIN 27 PIN 28 PIN 29 PIN 30 PIN 31 PIN 32 PIN 33 PIN 34

PIN OR GRY WHT YLW PINK OR GRY WHT YLW PINK

PIN 35 GND

SHIELD

1BLU 2BLU 2BLU 2BLU 2BLU 2BLU 3BLU 3BLU 3BLU 3BLU 3BLU

NC N/C PINS 4, 5, 6, 7 18,19, 24, 25,26, 36, AND 37

2.2.6 Camera Link Cable (CL Versions Only) The 26CL-02-26 cable assembly has been standardized as the Camera Link cable. This cable has a 26pin connector on both ends. This is a straight-through cable and the pin-out configuration is shown in Table 4 on page 9. Contact PULNiX for cable lengths other than 2 meters.

TM-1020 Series Progressive Scan Shutter Cameras

Page 20

Page 12 Installation 3M Camera Link Cable

18

5

19

6

20

7

21

8

22

9

23

10

24

11

25

12

26

13

13 4

26

17

25

3 10 9 8 6

19

5 3

16

2

15

1

14

4

18

7

24

16

11

2 23

15

Note:

22

1

2X Thumbscrews

21

14

12

26 Position High Density Mini D Ribbon (MDR) Male Plug

Cable

20

26 Position High Density Mini D Ribbon (MDR) Male Plug

17

FIGURE 7.

2X Thumbscrews

For CL versions, serial communication for camera control is done via the Camera Link connector on the rear panel of the camera.

TM-1020 Series Progressive Scan Shutter Cameras

Page 21

Page 13 Installation 2.2.7 Power Supplies and Power Cable Setup 2.2.7 (a)

Power Supplies

The TM-1020 series camera requires 12V DC power that is obtained through the 12-pin connector located on the rear panel of the camera. PULNiX recommends the following power supplies: K25-12

110V AC/12V DC

2.1A power supply (OEM type)

K50-12

110V AC/12V DC

4.2A power supply (OEM type)

PD-12UU

100-240V AC/12V DC

1.2A universal voltage power supply, US Plug

PD-12UUP

PD-12UU with12-pin connector

US plug

PD-12UE

PD-12UU

European plug

PD-12UEP

PD-12UU with 12-pin connector

European plug

For users providing power through the 12-pin connector, the PD-12P, PD-12UEP and PD-12UUP power supplies are available with the 12-pin mating connector already attached to the leads from the power supply. The PD-12UU and PD-12UE power supplies can be connected to the PULNiX power cable via a terminal strip or directly. When wiring the PD-12UU and PD-12UE power supplies directly, please note the following:

•

The lead ends must be twisted together and tin-soldered for strength and electrical continuity.

•

Shrink tubing or a similar insulator should be used to prevent exposed leads from touching and shorting.

•

The +12V lead is marked with a red stripe or white lettering; be sure not to reverse the leads.

•

All connections must be properly insulated to prevent shorting.

2.2.7 (b)

PULNiX Power Cables

If you are using PULNiX power cables such as the 12P-02S, please refer to the 12-pin connector pinout diagram in “12-Pin Connector (LVDS/RS-422 version)” on page 6. The cable pin-out diagram is shown in Figure 8 below. The color-coded leads use Gray for Ground and Yellow for +12V.

TM-1020 Series Progressive Scan Shutter Cameras

Page 22

Page 14 Installation FIGURE 8.

12P-02S Interface Cable (optional) +12 V GND (Gray) Power (Yellow) Video Out (Red Coax) HD In (White Coax) VD In (Black Coax)

Male

}

Monitor

Analog Frame Grabber

12P-02S Interface Cable Pin#

Lead Color

Function

Pin#

Lead Color

Function

1

Gray

GND

7

Black coax

VD Input

2

Yellow

+12V DC

8

White coax shield

Strobe out

3

Red coax shield

GND

9

White coax

HD Input

4

Red coax

Video Out

10

Brown

RXD (RS-232)

5

Orange coax shield

GND

11

Blue

Integration

6

Orange coax

VINIT IN

12

Black coax shield

TXD (RS-232)

Note:

Make sure that the unused leads are not touching and that there is no possibility that exposed wires could cause the leads to short.

2.2.7 (c)

“K” Series Power Supplies

The “K” series power supplies are designed primarily for OEM users who will be mounting the power supply inside a protective enclosure. For use in exposed situations, the PD-12 series power supplies are recommended. 1. 2. 3.

Attach the 110V line cord to the two terminals marked “AC.” Do not plug the cord into a 110V AC socket until later in the procedure. Attach the Gray and Yellow leads of the power cable to the Ground and 12V DC terminals, respectively. Replace the plastic terminal guard on the power supply.

2.2.7 (d)

Building Your Own Power Cable

Refer to the 12-pin connector pin-out in Section 2.2.2 (a on page 6. Connect the Ground lead to pin #1, and the +12V DC lead to pin #2 of the 12-pin connector. Power must be DC-regulated, and of sufficient current to properly power the camera. 2.2.7 (e)

Attaching the Power Cable to the Connector

The 12-pin connector is keyed and will only fit in one orientation. Follow these directions to properly attach the power cable to the camera connector: 1. 2.

Rotate the connector while applying slight pressure until the keyways line up. Press the connector into place until firmly seated.

TM-1020 Series Progressive Scan Shutter Cameras

Page 23

Page 15 Installation 3.

Plug the power cord into the 100V AC socket. This will power the camera up.

2.2.8 Attaching the Analog Video Output When connecting the TM-1020 series to an analog frame grabber or a monitor, use the BNC connector on the rear panel of the camera. The input of the monitor should be balanced for 75Ω termination. Standard RG-59 type coaxial cable should carry a full video signal for up to 500 feet. The TM-1020 series has a two-row binning mode that can be used to display real-time images on PULNiX’s PVM942 or PVM-1242 monitors. These monitors are specially modified to accept a 30Hz progressive scan image. The multi-conductor cable 12P-02S from PULNiX can be used to transmit analog video, power, sync. signals, and serial communication. The mini coaxial leads in PULNiX multi-conductor cables are designed for short runs of no longer than 100 feet. Note: Make sure that no extraneous wires are visible which could cause a short.

2.2.9 Attaching the Camera Lens The TM-1020 series camera accepts 1" or larger format size C-mount lenses. To attach the C-mount lens to the camera, carefully engage the threads and rotate the lens clockwise until it firmly seats on the mounting ring. Do not force the lens if it does not seat properly. Please note that some lenses with extremely long flangebacks may exceed the mounting depth of the camera.

TM-1020 Series Progressive Scan Shutter Cameras

Page 24

Page 16 Operation

Operation 3.1 Camera Rear Panel (LVDS/RS-422 Version) Mode Selection switch Shutter Speed Control switch

Up/Down switch UP

3 45 6

CDE AB

2

F0 1

23

8 67 9

01

45

78 9

3

SHUTTER MODE

DOWN

Digital Output connector DIGITAL 1

Power, RS-232, and External Sync Connector

2 3

9

10 11

4

8

Analog Output connector

7

12 5

6

POWER

VIDEO

3.1.1 Up/Down Switch The Mode Selection switch works in conjunction with the Up/Down switch. Refer to Table 6 above for information on the Up/Down switch.

3.1.2 Digital Output Connector Refer to Section 2.2.5 on page 11 for information on the digital output connector.

3.1.3 Analog Output Connector The LVDS-version cameras has a BNC connector on the rear panel to output analog video data.

3.1.4 Power, RS-232, and External Sync Connector Refer to Section 2.2.2 (a on page 6 for information on the power, RS-232, and external sync connector.

3.1.5 Shutter Speed Control Switch Please refer to Section 2.2.3 on page 10 for information on the Shutter Speed Control dial. The factory default settings correspond to the shutter speeds as shown in Table 5 on page 10.

TM-1020 Series Progressive Scan Shutter Cameras

Page 25

Page 17 Operation 3.1.6 Mode Selection Switch Various modes can be implemented with the rear panel Mode Selection switch. The Mode Selection switch works in conjunction with the Up/Down switch and RS-232 external control. Commands from the RS-232 interface will over-write the rear panel switch settings of the camera. The table below shows details on various modes. Mode Selection Switch

TABLE 6.

Mode Selection Switch Position

Mode Information

Up/Down Switch

Functions

0

Normal Mode

Display Mode (D)

1

Set Gain

Up/Down

Change gain

2

Set Vtop (A/D)

Up/Down

Change A/D ref. top

3

Set Vbottom(A/D)

Up/Down

Change A/D ref. bottom

4

Gain Selection #1

Up: 9dB, Down: 12dB

Lower gain selection

5

Gain Selection #2

Up: 18dB, Down: 22dB

Higher gain selection

6

Linear LUT

Up: Linear, Down: LUT

Linear/LUT selection

7

Knee Selection

Up/Down (Scroll)

Scroll 10 different LUTs

8

Async Reset Mode

Up: Normal, Down: Async

Async and normal shutter

9

Factory default Recall

Up/Down: Recall

Factory setting

A

Power up Setting

Up: Recall, Down: Save

Power up page setting

B

User Page Storage #1

Up: Recall, Down: Save

User page storage setting

C

User Page Storage #2

Up: Recall, Down: Save

User page storage setting

D

Direct Shutter Control

Up/Down

Shutter speed increment by 1H

E

Scan Format2

Up: Optional, Down: Binning

Two-row binning selection

F

Scan Format1

Up: Normal, Down: Normal

Custom option scanning

TM-1020 Series Progressive Scan Shutter Cameras

Page 26

Page 18 Operation 3.2 Camera Rear Panel (CL Versions)

CAMERA LINK 1 2 3

9

4

8

10 11

7

12 5

6

POWER

VIDEO

3.2.1 Digital Output Connector Refer to Section 2.2.6 on page 11 for information on digital output connectors.

3.2.2 Analog Output Connector The CL-version camera has a BNC connector on the rear panel to output analog video data.

3.2.3 Power and External Sync Connector Refer to Section 2.2.2 (b on page 7 for information on the power and external sync. connectors.

3.3 Progressive Scanning Standard TV-system scanning is 525 lines interlace scanning as specified in the RS-170 protocol. Every other horizontal line (odd lines and even lines) is scanned at a 60Hz rate per field, and the scanning is completed with two fields (one frame) at 30Hz rate. Because of the interlace scanning, the vertical resolution of CCD cameras is limited at 350 TV lines, regardless of the horizontal resolution. When electronic shutter is applied, the CCD can hold only one field of charge at each exposure. Therefore, the vertical resolution of the electronic-shutter camera is only 244 TV lines. The situation is the same for an HDTV-format camera, since it has interlaced scanning and the vertical resolution of the shuttered image is 500 lines. The TM-1020 series uses a state-of-the-art progressive scanning interline transfer CCD which scans all lines sequentially from top to bottom at one frame rate. Like a non-interlace computer screen, it generates a stable, crisp image without alternating lines and provides full vertical TV resolution of 1000 lines (a normal TV monitor display may not be able to show 1000 lines due to monitor resolution of 30Hz scanning). The interline transfer architecture is also important to generate simultaneous shuttering. This is different from full frame transfer architecture which requires a mechanical shutter or strobe light in order to freeze the object motion.

TM-1020 Series Progressive Scan Shutter Cameras

Page 27

Page 19 Operation The TM-1020 series outputs the progressive-scanned image with an electronic shutter in two different formats: 1.

2.

Progressive-scanning digital and analog output The CCD signal goes through A/D and D/A converters and through 10-bit in, 8-bit out look-up table (LUT). The analog output is the same as 75Ω, 1Vp-p format available from BNC and 12-pin connector. The digital output is available from 31-pin connector (RS-422 or RS-644) or Camera Link connector. Double-speed scanning output (display output) By selection, the two-row binning mode puts double-speed video for monitor display. It repeats twice from one frame of input video. Refer to Section 3.8 on page 27 for information on scan modes.

3.4 Electronic Shutter The TM-1020 series has a substrate drain-type shutter mechanism which provides a superb picture at various speeds without smearing. A built-in manual shutter speed control selects the electronic shutter rate of 1/60 (non-async mode only), 1/125, 1/250, 1/500, 1/1,000, 1/2,000, 1/4,000, 1/8,000, or 1/ 16,000 second. With VINIT high (5V), the CCD keeps discharging. With a negative pulse to VINIT, the camera resets and purges the charge momentarily. Then it starts integrating for the period of shutter control set by either an external pulse width or internal shutter control. Progressive scanning permits a full 1000 lines of vertical resolution, as compared to a conventional CCD camera which captures only half the vertical lines per shutter.

3.5 Integration The CCD imager of the TM-1020 series can be exposed for longer than the normal scan timing of 1/15 sec. This integration feature provides extra sensitivity for dark-environment applications. The progressive-scan imager permits a full frame of resolution in non-interlace format. Integration is achieved by controlling the #11 pin of the 12-pin connector to low (GND) or providing pulse-width control up to 1/15 frames. Please refer to Figure 2.2.2 on page 6 for pin-out information on the 12-pin connector.

TM-1020 Series Progressive Scan Shutter Cameras