The text of a manual · part 8 of 8
TM-1020 Series Progressive Scan Shutter Cameras Operation Manual, pages 64 to 72
Pages 64 to 72 of 72
The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PULNiX TM-1020 and SAIC TM-1020
Page 64
Page 6 Graphical User Interface 2.3.5 “Erase EEPROM” Menu 2.3.5 (a)
Load Setting From the EEPROM
The EEPROM section consists of three memory locations that allow you to Load (open), Write (save) and Report the current configuration. “Page Memory” has seven pages available to write current configurations. Page “0” is the factory default configuration and cannot be edited without a password. Page memory “1” is power up default. This page will allow you to save your default configuration to load at power up. Page memory will allow you to save the current Exposure Control, Knee, Gain, Vtop, and Vbtm settings. “User Memory” will allow you to load, write, and report the current configuration for Gain, Vtop, and Vbtm only. “System Memory” is the same as “User Memory” except that it requires a password for access. “Current Memory” is the camera’s current configuration. Select “Current” and click the “Report” button to display the cameras settings. The “Load” option in the menu bar allows you to restore the Gain Table setting from EEPROM. Click on “Load” and select “From Gain Table” in the menu to restore the setting from four user memory pages and four preset setting memory pages.
AccuPiXEL Series Camera-Control Software
Page 65
Page 7 AccuPiXEL Series Camera Serial Commands
3
AccuPiXEL Series Camera Serial Commands The AccuPiXEL series cameras can be controlled by serial command either via RS-232 or Camera Link. The Start character is always “:” and the End character is always <CR> (return). For example, to set Asynchronous Pulse Width Mode, send the command :SA9<CR> to the camera. The following table contains serial commands that can be used to control the camera.
TABLE 1.
1
Serial Command List
First Character
Second Character
Third Character
“S” (Shutter)
“M” (Manual)
“0” - “9” Mode
ACK
Manual Shutter Mode
“A” (ASYNC)
“0” - “8” Mode
ACK
Async Shutter Mode
“9” (Pulse Width Mode)
ACK
Async Pulse Width Mode
“X”
“000” - “419”
ACK
Direct Shutter Mode
Response
Functions
2
“G” (Gain)
“M”
“00” - “FF”
ACK
Gain Control
3
“V” (A/D Vref)
“T” (Top)
“00” - “FF”
ACK
Vtop reference setting
“B” (Bottom)
“00” - “FF”
ACK
Vbtm reference setting
“P” (Page)
“0” - “6”
ACK
Write current setting to Page EEPROM
“U” (User)
“A” - “D”
ACK
Write current setting to User EEPROM
“S” (System)
“A” - “D”
ACK
Write current setting to System EEPROM
“P” (Page)
“0” - “6”
ACK
Restore setting from Page EEPROM
“U” (User)
“A” - “D”
ACK
Restore setting from User EEPROM
“S” (System)
“A” - “D”
ACK
Restore setting from System EEPROM
“N” (kNee)
“0” - “9”
ACK
Load Preset Knee Table
“P” (Page)
“0” - “6”
ACK
ACK + “P” + (“9” - “F”) + 16 bytes
“U” (User)
“A” - “D”
ACK
ACK + “U” + (“A” - “D”) + 6 bytes
“S” (System)
“A” - “D”
ACK
ACK + “S” + (“A” - “D”) + (6 bytes)
“R” (Current)
ACK
ACK + “RR” + 16 bytes
“X” (Execute)
ACK
Set Camera with loaded data
“D” (Date)
info
Report CPU program version
4
5
6
“W” (Write)
“L”
“R” (Report)
AccuPiXEL Series Camera-Control Software
Page 66
Page 8 AccuPiXEL Series Camera Serial Commands TABLE 1.
7
Serial Command List (Continued)
First Character
Second Character
Third Character
“T” (Table)
“N” (kNee)
X1 + Y1 + X2 + Y2
Response ACK
Functions (X1, Y1) coordinate for knee 1 X1, Y1, X2, Y2: “00 - FF” (X2, Y2) coordinate for knee 2
“M” (Gamma)
ACK
“L” (Linear)
ACK
“C” (Switch A, B Table) 8
“N”
ACK
“0” (Normal)
ACK
Normal Scan Formal
“3” (Binning)
ACK
Double Speed Binning
Note:
One byte of data consists of two ASCII codes. For example, 0x3A is “3” (0 x 33) and “A” (0 x 41). <ACK> is 0 x 06. <NAK> is 0 x 15. <CR> is 0 x 0D.
Note:
1-byte data is represented in 2 ASCII characters, e.g. 0x3A is “3A” or 0x3341.
<CR> = 0x0D <ACK> = 0x06 <NAK> = 0x15 RS Command: RS Return:
TABLE 2.
“0” or “1”
Command or response terminator Command accepted Command not accepted RR<CR> RR + “16 bytes” + <CR>
16 Bytes Status Report Byte 1
MGCL (1 byte)
--
CDS Gain
Byte 2
Vtop(1 byte)
--
A/D reference voltage Top
Byte 3
Vbtm(1 byte)
--
A/D reference voltage Bottom
Byte 4
XA1 (1 byte)
--
X-Coordinate of right knee for table A
Byte 5
YA1 (1 byte)
--
Y-Coordinate of right knee for table A
Byte 6
XA2 (1 byte)
--
X-Coordinate of right knee for table A
Byte 7
YA2 (1 byte)
--
Y-Coordinate of right knee for table A
Byte 8
XB1
--
X-Coordinate of left knee for table B
Byte 9
YB1
--
Y-Coordinate of left knee for table B
Byte 10
XB2
--
X-Coordinate of left knee for table B
Byte 11
YB2
--
Y-Coordinate of left knee for table B
AccuPiXEL Series Camera-Control Software
Page 67
Page 9 AccuPiXEL Series Camera Serial Commands TABLE 2.
TABLE 3.
16 Bytes Status Report (Continued) Byte 12
FUNCFLAG1 (1 byte)
-- function flag #1
Byte 13
FUNCFLAG2 (1 byte)
-- function flag #2
Byte 14
SHTRNUM (1 byte)
-- current shutter number
Byte 15, 16
SHTRVAL (2 byte)
-- manual/direct shutter value
Function Flag Description 1 BIT
7
6
5
4
3
2
1
0
FUNCFLAG #1
Resv
Resv
Resv
Resv
SHTR2FLG
SHTR1FLG
MSEL2FLG
MSEL1FLG
SHTR2FLG (Bit3) -- 00 - (0) no shutter, 01 - (1) normal shutter SHTR1FLG (Bit2) -- 10 - (2) direct shutter, 11- (3) async shutter MSEL2FLG (Bit1) -- 00 - (0) normal scan, 01 - (1) partial scan #1 (optional) MSEL1FLG (Bit0) -- 10 - (0) normal scan, #2 (optional), 11-(3) two-row scan
TABLE 4.
Function Flag Description 2 BIT FUNCFLAG #2
7
6
5
4
3
2
1
0
TSELFLG
LUTB2FLG
LUTB1FLG
LUTA2FLG
LUTA1FLG
TSELFLG (Bit4) -- 0 - Select table A, 1 - Select table B LUTB2FLG (Bit3) -- 00 - Linear mode; 01 - Knee mode (for table B) LUTB1FLG (Bit2) --10 - Gamma mode; 11 - Direct input mode (reserved) LUTA2FLG (Bit1) -- 00 - Linear mode; 01 - Knee mode (for table A) LUTA1FLG (Bit0) -- 10 - Gamma mode; 11 - Direct input mode (reserved)
AccuPiXEL Series Camera-Control Software
Page 68
Page 69
Page 70
Page 71
Page 72
Imaging Products PULNiX America, Inc. 1330 Orleans Drive Sunnyvale, CA 94089
Tel: 408-747-0300 Tel: 800-445-5444 Fax: 408-747-0660
Email: imaging@pulnix.com w w w .p ulnix.c om
Japan PULNiX America, Inc. 1-11-14 Hongo, Bunkyo-ku Tokyo 113-0033 Tel: 81-3-5805-2455 Fax: 81-3-5805-8082 www.pulnix.co.jp
Australia PULNiX America, Inc. 16 / 35 Garden Road Clayton,VIC 3168 Tel: 61-(0)3-9546-0222 Fax: 61-(0)3-9562-4892 email: pulnix@ozemail.com.au
United Kingdom PULNiX Europe, Ltd. Aviary Court, Wade Road Basingstoke, Hampshire RG24 8PE Tel: 44(0)1256-475555 Fax: 44(0)1256-466268 www.pulnix.eu.com
Germany PULNiX Deutschland, GmbH. Siemensstrasse 12 D-63755 Alzenau Tel: 49(0)6023-9625-0 Fax: 49(0)6023-9625-11 www.pulnix.de
69-0109 Rev. A