Spec sheet · Reliance Electric
Reliance Electric 57C409 Spec Sheet
Spec sheet2 pagesPDF 109 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Much of this sheet is scanned with little readable text, so this says only what its text supports. Each line names its page in the PDF.
Two-page Reliance Electric spec sheet (J-3709, 1988) for the 57C409 2 Channel Analog Input Module. It lists ambient limits, power, dimensions and isolation, and shows the external terminal connections. The text comes from a scan read by OCR.
- What it is
- 2 channel analog input module p. 1
- Isolation
- 600 volt isolation; two inputs per isolated common p. 1
- System power
- +5 volts: 3050 ma p. 1
- Power dissipation
- 25 Watts maximum p. 1
- Operating temperature
- 0C to 60C p. 1
- Storage temperature
- -40C to 85C p. 1
- Humidity
- 5-90% non-condensing p. 1
- Dimensions
- 11.75 in high, 1.25 in wide, 7.375 in deep p. 1
- Channel 0 inputs
- +10V and +1V terminals plus common p. 2
What this sheet walks you through
- External terminal connections p. 2
Good to know
- More detail is in the 2 Channel Analog Input Module Instruction Manual, J-3637. p. 2
Questions this sheet answers
How many inputs does the Reliance 57C409 have?
Two analog input channels, with two inputs per isolated common. p. 1
How much +5 V power does the 57C409 need?
The spec sheet lists +5 volts at 3050 ma. p. 1
What is the isolation rating of the 57C409?
600 volt isolation, with two inputs per isolated common. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, read from a scan by OCR; it may hold reading errors
2 Channel Analog Input Module (M/N 57C409)
Module Specifications
Ambient Conditions
Storage temperature: -40C - 85C Operating temperature: OC - 60C Humidity: 5-90% non-condensing
Maximum Module Power Dissipation
25 Watts
Dimensions
System Power Requirements
Height: 11.75 inches Width: 1.25 inches Depth: 7.375 inches
+5 volts: 3050 ma
Isolated Power Supply
+15 volts: 25 ma -15 volts: 25 ma Accuracy: + 1%
Thermal Drift: +.01% per degree C Analog/Digital Converter
Number of input channels: Repeatability:
Linearity:
Thermal drift:
Offset:
- Update period
- 2
1 LSB = .025%+ 025%+.015% per degree C+79 mv to -55mv max
500 micro-seconds to 32.767 seconds
Two inputs per isolated common
600 volt isolation
Copyright Reliance Electric 1988
IndustrialCONTROLSJ-3709RELIANCE ELECTRICC]
Page2of 2
Open in the PDF
The text of page 2, read from a scan by OCR; it may hold reading errors
ANALOG
= AC}
RELIANCE ELECTRIC., OWMWOAN OO AWN =
EXTERNAL CONNECTIONS© M/N e 570371 =) =] ein LengthApprox. 60”Terminal StriplOcOfle}mic!TeleTaIS|flei) fea)eis|i)=) i)OWOMOND OA PWNflel iISeO]User walConnectionsCh 0 +10VCh 0 +1V CommonCh 1410VCh 14+ 1V Common
No connection Isolated +15V Common Isolated, -15V
(For additional information, please refer to the 2 Channel Analog Input Module
Instruction Manual, J-3637)
Reliance Electric / 24703 Euclid Avenue / Cleveland, Ohio 44117 / (216) 266-7000
Printed in U.S.A.J-3709RELIANCE ELECTRIC#LJanuary 1988