The text of a manual · part 12 of 15
Programmable controller Twido Catalog, pages 57 to 61
Pages 57 to 61 of 76: Curves (continued); References (continued), dimensions
The original document is the PDF (3.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Schneider ABE 7E16EPN20, Schneider ABE 7E16SPN20, Schneider TWDALM3LT, Telemecanique ABE 7E16SPN22 and Telemecanique ABE 7E16SRM20
Page 57
Connection interfaces
Curves (continued)
0
Advantys, Telefast® pre-wired system for Twido Connection sub-bases
Electrical durability (in millions of operating cycles, conforming to IEC 60947-5-1) ABE 7B20MRM20 and ABE 7E16SRM20 d.c. loads DC 12 curves (1)
DC 13 curves (2)
Millions of operating cycles 0,50 0,45 0,40 0,35 0,30 0,25 0,20 0,15 0,10 0,05 0,00 0,25 0,50
Millions of operating cycles 2,0 1,8 1,6 1,4 230V 1,2 110V 1,0 48V 0,8 0,6 0,4 0,2 0,0 0 0,2 0,4
230V 110V 48V
0,75
1
1,25
1,50
1,75
2
24V
0,6
0,8
Current A a.c. loads AC 12 curves (3)
AC 14 curves (4)
Millions of operating cycles
Millions of operating cycles 1,0 0,9 L/R = 10ms 48V 0,8 0,7 L/R = 10ms 24V 0,6 0,5 L/R = 60ms 48V 0,4 L/R = 60ms 24V 0,3 0,2 0,1 0,0 0 0,2 0,4 0,6 0,8
1,50 24V
1,25
48V
1,00
110V
0,75
230V
0,50 0,25 0,00 0
1 Current A
0,5
1
1,5
2
Current A
1 Current A
AC 15 curves (5) Millions of operating cycles 1,0 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0,1 0,0 0
24V 48V
0,5
1
1,5
2 Current A
(1) DC 12: control of resistive loads and of solid state loads isolated by optocoupler, L/R ≤ 1 ms. (2) DC 13: control of electromagnets, L/R ≤ 2 x (Ue x Ie) in ms, Ue: Rated operational voltage, Ie: rated operational current (with a protective diode on the load, DC12 curves must be used with a coefficient of 0.9 applied to the number in millions of operating cycles) (3) AC 12: control of resistive loads and of solid state loads isolated by optocoupler, cos ϕ ≥ 0.9. (4) AC 14: control of small electromagnetic loads ≤ 72 VA, make: cos ϕ = 0.3, break: cos ϕ = 0.3. (5) AC 15: control of electromagnetic loads > 72 VA, make: cos ϕ = 0.7, break: cos ϕ = 0.4.
Presentation: page 52
Characteristics: pages 54 and 55
Compatibility: page 53
References, dimensions: pages 58 and 59
Schemes: pages 60 to 63
57
Page 58
Connection interfaces
References
0
Advantys, Telefast® pre-wired system for Twido Connection sub-bases
For Twido modular base controllers Number of I/O
Number, type of input
Number, type of output
Compatibility
20
12, sink c 24 V
8, source c 24 V
TWD LMDA20DTK/ LMDA40DTK Yes
12, sink c 24 V ABE 7B20MPN20
LED Fuse per channel No No
ABE7B20MPN20 kg 0.430
Yes
ABE7B20MPN22
0.430
No
ABE7B20MRM20
0.430
2, source TWD No c 24 V, LMDA20DTK/ 2A LMDA40DTK and 6, relay c 24/ a 250 V, 3A
Reference
Weight
For Twido extension modules
ABE 7E16EPN20
Number of inputs
Type of input
Compatibility
16
Sink c 24 V
TWD DDI16DK/ DDI32DK
Number of outputs
Type of output
Compatibility
16
Source c 24 V
TWD DDO16TK/ DDO32TK
Relay c 24/a 250 V, 3 A
TWD DDO16TK/ DDO32TK
LED Fuse per channel No No
Reference
ABE7E16EPN20
Reference
Weight kg 0.430
LED Fuse per channel No No
Weight
ABE7E16SPN20 kg 0.450
Yes
Yes
ABE7E16SPN22
0.450
No
No
ABE7E16SRM20
0.430
Connection cables for Twido modular base controllers ABE 7E16SRM20
Type of Compatibility Type of connection Gauge/ Length Reference signal C.s.a. Twido Telefast side side AWG/ m mm2 HE 10 HE 10 28/ 0.5 ABFT26B050 Discrete TWD 0.08 LMDA20DTK/ 26-way 26-way inputs/ outputs LMDA40DTK 1.0 ABFT26B100
TWD DDI16DK/ DDI32DK/ DDO16TK/ DDO32TK
HE 10 20-way
HE 10 20-way
28/ 0.08
Weight kg 0.080
0.110
2.0
ABFT26B200
0.180
0.5
ABFT20E050
0.060
1.0
ABFT20E100
0.080
2.0
ABFT20E200
0.140
Accessories Description
Optional snap-on terminal blocks
Quick-blow fuses 5 x 20, 250 V, UL
Presentation, description: pages 50 and 51
58
Presentation, compatibility: pages 52 and 53
Characteristics: pages 54 and 55
Number Characteristics of shunted terminals 20 –
Sold in lots of
Unit reference
5
ABE7BV20 kg 0.060
12 + 8
–
5
ABE7BV20TB
0.060
–
0.125 A 0.315 A 1A 2A
10 10 10 10
ABE7FU012 ABE7FU030 ABE7FU100 ABE7FU200
0.010 0.010 0.010 0.010
Dimensions: page 59
Schemes: pages 60 to 63
Weight
Page 59
Connection interfaces
References (continued), dimensions
0
Advantys, Telefast® pre-wired system for Twido Cables for connection sub-bases and accessories
References (continued) Separate components Description
Type
Compatibility
Reference
Connectors (sold in lots of 5)
HE 10 female 26-way
TWD LMDA20DTK/ LMDA40DTK TWD DDI16DK/ DDI32DK/ DDO16TK/ DDO32TK TWD DDIpDT/DAI8DT/ DDO8pT/DRApRT TWD DMM8DRT/ AMIppT/ARI8HT
TWDFCN2K26
Weight kg –
TWDFCN2K20
–
TWDFBT2T10
–
TWDFTB2T11
–
HE 10 female 20-way
Screw terminal blocks (sold in lots of 2)
10-way
11-way
Description
Compatibility
Type of connection Twido Other side end
Cables for discrete I/O
TWD LMDA20DTK/ LMDA40DTK TWD DDI16DK/ DDI32DK/ DDO16TK/ DDO32TK 20 conductors
HE 10 26-way
Bare wires
HE 10 20-way
–
Pre-formed cable, rolled
Gauge/ C.s.a.
Length
Reference
Weight
AWG/mm2 22/ 0.035 m 3.0 5.0
TWDFCW30M TWDFCW50M kg 0.405 0.670
Bare wires
22/ 0.035
3.0 5.0
TWDFCW30K TWDFCW50K
0.405 0.670
–
28/ 0.08
20.0
ABFC20R200
1.310
Dimensions ABE 7B20MPN20, ABE 7B20MPN22, ABE 7B20MRM20, ABE 7E16SPN22, ABE 7E16SRM20 Mounting on 35 mm 5 rail
Screw mounting (retractable lugs)
4.44 (113)
0.53 (13.5)
(1) 2.46 (62.5)
3.66 (93)
3.26 (83)
1.63 (41.5)
5.11 (130)
2xØ4
2.65 (67.5)
(1) ABE 7BV20, ABE 7BV20TB.
ABE 7E16EPN20, ABE 7E16SPN20 Mounting on 35 mm 5 rail
(1)
1.92 (49) 0.53 (13.5)
0.94 (24)
4.17 (106)
2.36 (60) 2.51 (64)
Dual Dimensions inches (mm)
(1) ABE 7BV20, ABE 7BV20TB.
59
Page 60
Connection interfaces
Schemes
0
Advantys, Telefast® pre-wired system for Twido
ABE 7B20MPN20
HE10
BJ1 26
I0 I1 I2 I3 I4 I5 I6 I7 I8 I9 I10 I11 0V
26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 + 24 V + 24 V + 24 V 0V 0V
24
23
BJ1-11
BJ2-5
BJ2-15
25
0V
+24V
BJ1
9
10
22
BJ2-5
BJ2-16
BJ1-13 21 8
BJ1-15 20
BJ2-6
BJ2-17
BJ1-17 19
7
BJ1-19 6
BJ1-21
4
5
BJ1-23 16
Q5 Q6 Q7
3
Q1 Q2 Q3 Q4
2
18
24
I10 I11 Q0
BJ4
17
23
BJ1-25
BJ2-7
BJ2-18
21 22
15
BJ2-8
BJ2-19
20
BJ1-4
BJ2-9
BJ2-20
19
14
BJ2-21
18
BJ1-6
BJ1-10 11
17
13
BJ1-12 10
16
I9
I8
10
9
15
1
BJ1-14 9
I7
14
BJ1-8
BJ1-16 8
I6
8
BJ1-18 7
I5
6
I4
13
BJ2-10
11 12
BJ2-22
10
BJ1-20
BJ1-22
9
6
5
8
I2 I3
5
BJ1-24 4
4
BJ1-26 3
I1
2
BJ3
1
0V
3
+24V I0
2
1
BJ2
7
12
6
BJ2-11
5
BJ2-12
4
BJ2-13
3
7
2
BJ2-14
1
BJ2-3
0 V-4
0 V-3
24 V-2
24 V-1
HE10, 26-way
CI10 CI11 CQ0 CQ1 CQ2 CQ3CQ4 CQ5 CQ6 CQ7
CI0 CI1 CI2 CI3 CI4 CI5 CI6 CI7 CI8 CI9
(1)
(1)
ABE 7B20MPN22
18
19
20 21
22
23
24
25 26
I0 I1 I2 I3 I4 I5 I6 I7 I8 I9 I10 I11 0V
BJ1-4
15 16 17
BJ1-6
14
BJ1-8
13
BJ1-10
12
BJ1-11
11
BJ1-12
10
BJ1-13
9
BJ1-14
8
BJ1-15
7
BJ1-16
6
BJ1-17
5
BJ1-18
4
BJ1-19
3
BJ1-20
BJ1-22
BJ1-23
BJ1 2
BJ1-21
0 V-3
0 V-4 BJ1-24
24 V-2
HE10 1
BJ1-25
BJ1-26
24 V-1
HE10, 26-way
26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
24
22 23
BJ2-14 21
9
8
10
BJ2-13 20 7
19
BJ2-12
BJ2-11 18
17
0V +24V
6
2
Q5 Q6 Q7
5
14 1
Q1 Q2 Q3 Q4
4
13
BJ2-22
12
10
9
8
7
CI0 CI1 CI2 CI3 CI4 CI5 CI6 CI7 CI8 CI9
16
11
I10 I11 Q0
BJ4
3
BJ2-10
10
I9
15
BJ2-21
9
I8
BJ2-9
8
BJ2-20
7
I6 I7
BJ2-8
BJ2-19
6
I5
6
BJ2-7 5
I4
5
BJ2-18
I2 I3
4
4 I1
3
BJ2-6 3 I0
2
BJ2-17 2
0V +24V BJ3
1
BJ2-5
BJ2
1
BJ2-16
BJ2-4
BJ2-15
BJ2-3
BJ1
CI10 CI11 CQ0 CQ1 CQ2 CQ3 CQ4 CQ5 CQ6 CQ7
(1)
(1)
(1) Example of output connections. When connecting an inductive load, include a diode or a varistor.
Presentation: page 52
60
Compatibility: page 53
Characteristics: pages 54 and 55
References, dimensions: pages 58 and 59
Curves: pages 56 and 57
Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 + 24 V + 24 V + 24 V 0V 0V
Page 61
Connection interfaces
Schemes (continued)
0
Advantys, Telefast® pre-wired system for Twido
ABE 7B20MRM20
HE10
BJ1 19
20 21
22
J1-21
23
24
25 26
J1-11
18
BJ2-1
15 16 17
BJ2-2
14
J1-15
13
BJ2-3
12
J1-17
11
BJ2-4
10
J1-19
9
BJ2-5
8
BJ2-6
7
BJ2-7
6
BJ2-8
5
BJ2-9
4
BJ2-10
3
BJ2-11
2
BJ2-12
1
J1-13
0 V-4
24 V-1
24 V-2
0 V-3
HE10, 26-way
I0 I1 I2 I3 I4 I5 I6 I7 I8 I9 I10 I11 0V
26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 + 24 V + 24 V + 24 V 0V 0V
S1
BJ1
21
22
23
I10 I11 +24V Q0 Q1 0V
Q2
Q3
Q4
1 CQ
Q5
Q6 Q7
9
10
8
7
6
4
5
BJ2-20
24
15
14 3
2
1
10
BJ4
CI0 CI1 CI2 CI3 CI4 CI5 CI6 CI7 CI8 CI9
BJ2-20
BJ2-24
20
BJ2-23
19
BJ2-20
18
BJ2-19
17
BJ2-20
16
BJ2-18
24 V 13
BJ2-20
BJ1-4 12
BJ2-17
BJ1-6
I9
0V
BJ1-8
11
I8
8
10
– R7
BJ1-10
– R6
I7
9
BJ1-14 7 7
6
– R5
BJ1-12
BJ1-16 6
I6
– R4
9
BJ1-18 5
I5
– R3
8
BJ1-20 4
I4
5
BJ1-22 3
I3
4
BJ1-24 2
I2
3
BJ1-26
I1
2
BJ3
I0
1
BJ2
1
BJ2-20
– R2
BJ2-22
S0
CI10 CI11 CQ0 CQ1 CQ2 CQ3 CQ4 CQ5 CQ6 CQ7
(1)
(1)
(1) Example of output connections. When connecting an inductive load, include a diode or a varistor.
ABE 7E16EPN20
HE10
BJ1
Presentation: page 52
20
BJ1-15
BJ1-13
BJ1-11
BJ1-9
BJ1-7
BJ1-5
13
14
15
16
17
18
Compatibility: page 53
9
8
7
6
5
3
C8 C9 C10 C11 C12 C13 C14 C15 C
C
Characteristics: pages 54 and 55
16 15 14 13 12 11 10
9
8
7
6
5
4 2
3 1
I8 I9 I10 I11 I12 I13 I14 I15 0V NC
BJ1 10
C3 C4 C5 C6 C7
20 19 18 17
20
BJ1-17 12
C0 C1 C2
4
BJ1-19 11
C
6
C
BJ4
I12 I13 I14 I15 0V +24V
2
BJ1-6 10
I10 I11
1
BJ1-8 9
I9
10
BJ1-10 8
I8
9
BJ1-12 7
I7
8
BJ1-14 6
I6
7
BJ1-16 5
I5
5
BJ1-18 4
I4
4
BJ1-20 3
I2
3
I1
I3
I0 I1 I2 I3 I4 I5 I6 I7 0V NC
19
19
BJ2-3
18
BJ2-11
17
BJ2-4
16
BJ2-12
15
1 2
BJ2-6
14
BJ2-5
13
BJ2-13
11 12
BJ2-14
10
BJ2-7
9
BJ2-15
8
I0
2
BJ3
7
NC C
1
BJ2
6
BJ2-8
5
BJ2-16
4
BJ2-9
3
BJ2-17
2
BJ2-18
1
BJ2-10
0 V-4
0 V-3
24 V-2
24 V-1
HE10, 20-way
References, dimensions: pages 58 and 59
Curves: pages 56 and 57
61