Manual · SICK AG
CMC600-101 Parameter Memory Operating Instructions
Manual6 pagesPDF 931 KB
Operating instructions (German and English) for the SICK CMC600-101 plug-in parameter memory module for CDB620 and CDM connection modules.
Covers · 1 model
The models it covers
Summary
What is in it
SICK's bilingual (German and English) operating instructions for the CMC600-101, a plug-in parameter memory module for the CDB620, CDM420, CDM425 and CDM490 connection modules. It stores a SICK sensor's parameter set and copies it into a replacement sensor. The sheet lists supported bar code scanners, code readers, RFID interrogators and laser measurement sensors, installation requirements, installation and start-up steps, configuration switches and LEDs, how the module operates, the additional switching inputs and outputs, and technical data.
Its parts
- Features
- Installation and Commissioning Requirements
- Installation in the Connection Module, Initial Start-up
- Configuration Switches and Indicators
- CMC600: Method of Operation
- Additional switching inputs and outputs
- Technical data
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
SICK operating instructions (8015190/2012-07, in German and English) for the CMC600-101 parameter memory, a plug-in module for the CDB620, CDM420, CDM425 and CDM490 connection modules that stores the parameter set of a SICK sensor. They show how to install it, set its network address, operating mode and write-protect switches, read its LEDs and clear its memory.
- Device type
- Plug-in parameter memory module for the CDB620, CDM420, CDM425 or CDM490 connection modules p. 1
- Function
- Stores the parameter set of one SICK sensor and loads it into a replacement sensor automatically p. 1
- Supported sensors
- CLV6xx (not CLV69x), Lector®620, RFH6xx, RFU63x, CLV42x to 45x, CLV480, CLV/X490, ICR84x-2, ICR85x-2, JEF300, JEF500 p. 1
- Power
- 10 to 30 V DC via CDB/CDM; 500 mW (20 mA at 24 V DC) p. 5
- Extra I/O
- 2 opto-decoupled inputs (max. 32 V); 2 PNP outputs (max. 100 mA, short-circuit-proof); sensor-dependent p. 5
- Temperature
- Operation –35 to +40 °C; storage –35 to +70 °C p. 5
- Part number
- CMC600-101, no. 1042259 p. 5
- Size and weight
- 70 x 23 x 17 mm; approx. 12 g p. 5
- Operating modes
- Mode switch: 0 transparent; 1 to 4 CAN scanner network; 5 to 8 CANopen; 9 CLX200 host interface; D PROFINET (IDpro only); E PROFIBUS via CMF400; F parameters only (delivery) p. 3
- Network address
- Two decimal rotary switches (tens and units); 00 uses the address stored in the parameter set (delivery status) p. 2
- Write protect
- Lower switch position protects the memory against clearing or overwriting p. 2
- Indicators
- 2 LEDs: yellow for CMC600 state, green for sensor access p. 3, 5
- Sensor firmware
- From V. 1.00 for CLV62x, Lector®620, RFH6xx, RFU63x, JEF300/500; CLV63x V. 2.00; CLV64x V. 2.51; CLV65x V. 3.00; CLV42x V. 1.30; CLV43x to 45x V. 3.40; CLV480/CLV/X490 V. 3.30; ICR84x-2/85x-2 V. 3.00 p. 5
- Interface
- Communicates over the sensor's serial AUX interface, then runs transparently p. 4
What this manual walks you through
- Installing the module in the connection module and first start-up p. 2
- Setting the network address switches p. 2
- Choosing the operating mode and data rate p. 3
- Reading the yellow and green LEDs p. 3
- How the sensor stores and loads parameters p. 4
- Clearing the module memory p. 4, 5
- Restart behavior with a missing or mismatched module p. 5
- Extra switching inputs and outputs per sensor p. 5
Good to know
- Mounting, wiring and configuration only between 0 and +40 °C; below 0 °C the module may only be at rest. p. 2
- Switch settings must not be changed below 0 °C. p. 2
- Modes 9, A and B are not for IDpro sensors or JEF300/500. p. 3
- With write protection off, each permanent save in the sensor overwrites the stored parameter values. p. 4
- The connection module should carry the label "CLV6xx compatible", or use of the extra inputs and outputs is restricted. p. 1
Questions this manual answers
What does the SICK CMC600 parameter memory do?
It keeps a copy of a sensor's parameter set, and when the sensor is replaced it loads those values into the new sensor automatically. p. 1
How do I clear the CMC600 memory?
Set write protect OFF, connect a PC to the AUX interface, open a terminal or the SOPAS ET/CLV-Setup terminal emulator and send STX:3CMC_CLEARETX; CLV4xx and ICR sensors can also use CLEAR CMC in CLV-Setup. p. 4
What does a fast blinking yellow LED on the CMC600 mean?
The module is in transparent mode (mode 0) and the sensor cannot access it. p. 3
Which connection modules take the CMC600-101?
The CDB620, CDM420, CDM425 and CDM490. p. 1
Does the CMC600 add inputs and outputs to a CLV42x scanner?
It adds 2 inputs and no outputs for CLV42x to 45x scanners; CLV6xx scanners get 2 inputs and 2 outputs. p. 5
The whole text · 1 part
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file