Two SENSICK catalogue pages for the SICK WT 24 Exi photoelectric proximity switches with background suppression and infrared light. They cover the types WT 24-X 2101, WT 24-X 4101 and WT 24-X 4601, with a dimensional drawing, technical data and order information. They let a reader check scanning distance, supply, output, connections and housing data.

Device
Photoelectric proximity switch with adjustable background suppression, infrared light, DC p. 1
Scanning distance
300 . . . 2000 mm or 150 . . . 600 mm depending on type, adjustable p. 2
Supply voltage
8.2 V DC (5 . . .13.5 V) p. 2
Switching output
Control current dependent on switching state, to NAMUR EN 50227 p. 2
Output current
≥ 2.2 mA with light beam unbroken, ≤ 1 mA with light beam broken p. 2
Connections
PG 9 cable gland with terminals, or rotatable 4-pin M 12 plug p. 1
Light source
LED, infrared light p. 2
Response time
≤ 10 ms; max. switching frequency 50/s p. 2
Switching mode
Light-switching p. 2
Enclosure rating
IP 65 p. 2
Ambient temperature
Operation – 20 °C . . . + 50 °C; storage – 25 °C . . . + 70 °C p. 2
Weight and housing
Approx. 330 g; zinc die-cast housing p. 2
Light source life
Average service life 100,000 h p. 2

What this manual walks you through

  • Dimensions, mounting holes and adjustment elements p. 1
  • Technical data p. 2
  • Scanning distance on black, grey and white objects p. 2

Good to know

  • The sheet states explosion protection EEx ia IIC T6 and approval PTB No. Ex97 D2034. p. 1, 2
  • Supply is to be through a disconnector device to EN 2 Ex. p. 2
  • Ripple may not exceed or fall short of the supply voltage tolerances. p. 2

Questions this manual answers

What is the scanning range of the SICK WT 24?

The WT 24 Exi types scan 300 . . . 2000 mm or 150 . . . 600 mm depending on type, both adjustable. p. 2

What supply voltage does the WT 24 Exi use?

8.2 V DC, within limits of 5 to 13.5 V. p. 2

What kind of output does the WT 24 Exi have?

A control current that depends on the switching state, to NAMUR EN 50227. p. 2

How is the WT 24 Exi connected?

Through a PG 9 cable gland to terminals, or a rotatable 4-pin M 12 plug. p. 1

The file

Size and text

Pages2
PDF214 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of SICK AG WT 24 Manual

The text of page 1, from the PDF itself

WT 24 Exi Photoelectric proximity switches, background suppression, infrared light -- DC Dimensional drawing

Scanning distance 300 . . . 2000 mm

106 14 17.51

Photoelectric reflex switches 2

487.53 25

  • Adjustable background

suppression

  • Explosion protection EEx ia IIC T6
  • Plug rotatable by 90°
  • Terminal chamber

5max. 1525M578 3027Adjustments possible1 2 3 4 526 7 8 9 1 0 9 1 0Connection types

Accessories Cable receptacles Mounting brackets Power supply units

220SENSICK CATALOGUEpage 496 510 56411.865

WT 24-X 2101 WT 24-X 4101 WT 24-X 4601

0.84.7■ Infrared lightC6.514

Scanning distance 150 . . . 600 mm

WT 24-X 2101

WT 24-X 4101 WT 24-X 4601

PG 9, terminals4-pin, M 121L+12M21 3L+ M

Alignment sight LED signal strength indicator Standard direction of the material being scanned Centre of transmitter’s optical axis Centre of receiver’s optical axis M 5 threaded mounting hole – 8 mm deep M 5 threaded mounting hole PG 9 cable gland or M 12 plug, rotatable Scanning distance adjustment Scanning distance indicator

Page 2 of SICK AG WT 24 Manual

The text of page 2, from the PDF itself

WT 24 Exi Technical data

WT 24-

Scanning distance

300 . . . 2000 mm, adjustable 150 . . . 600 mm, adjustable

Light source 1), light type

LED, infrared light

Supply voltage VS2) Ripple 4)

8.2 V DC (5 . . .13.5 V) 3) 0.4 VSS

Terminal capacitance Terminal inductance Current consumption 5) Light beam unbroken Light beam broken

≤ 15 nF ≤ 75 µHX 2101 X 4101 X 4601≥ 2.2 mA ≤ 1 mASwitching output

Control current dependent on switching state (to NAMUR EN 50227)

Switching mode Response time 6) Max. switching frequency 7)

Light-switching ≤ 10 ms 50/s

Connection types

Plug Terminal connection

Approval VDE protection class 8) Circuit protection 9) Enclosure rating

PTB No. Ex97 D2034

Ambient temperature TA

Operation – 20 °C . . . + 50 °C Storage – 25 °C . . . + 70 °C Approx. 330 g Zinc die-cast housing

V A, C IP 65

Weight Housing material

1) Average service life 100,000 h 3) Limit values at TA = + 25 °C 4) May not exceed or fall short of 2) Supply with disconnector device EN 2 Ex VS tolerances

5) Without load 6) Signal transit time with resistive load 7) With light/dark ratio 1:1 8) Reference voltage 50 V DC

9) A = VS connections reverse-polarity protected C = Interference pulse suppression

Order information Type Part No. 1 011 974 WT 24-X 2101

Scanning distance 251 A2001 B1502 A2002 B150 4503 A2003 B1506000 (mm)5003 A B

WT 24-X 4101 WT 24-X 4601

30020150020001 011 973 1 013 1206%/90%151 10001500

Scanning distance on black, 6 % remission Scanning distance on grey, 18 % remission Scanning distance on white, 90 % remission WT 24-X 2101/X 4101 WT 24-X 4601

2000% of scanning distance1 2800102 18%/90% 3590%/90% 0(mm)500100015002000SENSICK CATALOGUE221