Manual · SICK AG
SICK AG WT 24 Manual
Manual2 pagesPDF 214 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
Two SENSICK catalogue pages for the SICK WT 24 Exi photoelectric proximity switches with background suppression and infrared light. They cover the types WT 24-X 2101, WT 24-X 4101 and WT 24-X 4601, with a dimensional drawing, technical data and order information. They let a reader check scanning distance, supply, output, connections and housing data.
- Device
- Photoelectric proximity switch with adjustable background suppression, infrared light, DC p. 1
- Scanning distance
- 300 . . . 2000 mm or 150 . . . 600 mm depending on type, adjustable p. 2
- Supply voltage
- 8.2 V DC (5 . . .13.5 V) p. 2
- Switching output
- Control current dependent on switching state, to NAMUR EN 50227 p. 2
- Output current
- ≥ 2.2 mA with light beam unbroken, ≤ 1 mA with light beam broken p. 2
- Connections
- PG 9 cable gland with terminals, or rotatable 4-pin M 12 plug p. 1
- Light source
- LED, infrared light p. 2
- Response time
- ≤ 10 ms; max. switching frequency 50/s p. 2
- Switching mode
- Light-switching p. 2
- Enclosure rating
- IP 65 p. 2
- Ambient temperature
- Operation – 20 °C . . . + 50 °C; storage – 25 °C . . . + 70 °C p. 2
- Weight and housing
- Approx. 330 g; zinc die-cast housing p. 2
- Light source life
- Average service life 100,000 h p. 2
What this manual walks you through
- Dimensions, mounting holes and adjustment elements p. 1
- Technical data p. 2
- Scanning distance on black, grey and white objects p. 2
Good to know
- The sheet states explosion protection EEx ia IIC T6 and approval PTB No. Ex97 D2034. p. 1, 2
- Supply is to be through a disconnector device to EN 2 Ex. p. 2
- Ripple may not exceed or fall short of the supply voltage tolerances. p. 2
Questions this manual answers
What is the scanning range of the SICK WT 24?
The WT 24 Exi types scan 300 . . . 2000 mm or 150 . . . 600 mm depending on type, both adjustable. p. 2
What supply voltage does the WT 24 Exi use?
8.2 V DC, within limits of 5 to 13.5 V. p. 2
What kind of output does the WT 24 Exi have?
A control current that depends on the switching state, to NAMUR EN 50227. p. 2
How is the WT 24 Exi connected?
Through a PG 9 cable gland to terminals, or a rotatable 4-pin M 12 plug. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
WT 24 Exi Photoelectric proximity switches, background suppression, infrared light -- DC Dimensional drawing
Scanning distance 300 . . . 2000 mm
106 14 17.51
Photoelectric reflex switches 2
487.53 25
- Adjustable background
suppression
- Explosion protection EEx ia IIC T6
- Plug rotatable by 90°
- Terminal chamber
5max. 1525M578 3027Adjustments possible1 2 3 4 526 7 8 9 1 0 9 1 0Connection types
Accessories Cable receptacles Mounting brackets Power supply units
220SENSICK CATALOGUEpage 496 510 56411.865
WT 24-X 2101 WT 24-X 4101 WT 24-X 4601
0.84.7■ Infrared lightC6.514
Scanning distance 150 . . . 600 mm
WT 24-X 2101
WT 24-X 4101 WT 24-X 4601
PG 9, terminals4-pin, M 121L+12M21 3L+ M
Alignment sight LED signal strength indicator Standard direction of the material being scanned Centre of transmitter’s optical axis Centre of receiver’s optical axis M 5 threaded mounting hole – 8 mm deep M 5 threaded mounting hole PG 9 cable gland or M 12 plug, rotatable Scanning distance adjustment Scanning distance indicator
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
WT 24 Exi Technical data
WT 24-
Scanning distance
300 . . . 2000 mm, adjustable 150 . . . 600 mm, adjustable
Light source 1), light type
LED, infrared light
Supply voltage VS2) Ripple 4)
8.2 V DC (5 . . .13.5 V) 3) 0.4 VSS
Terminal capacitance Terminal inductance Current consumption 5) Light beam unbroken Light beam broken
≤ 15 nF ≤ 75 µHX 2101 X 4101 X 4601≥ 2.2 mA ≤ 1 mASwitching output
Control current dependent on switching state (to NAMUR EN 50227)
Switching mode Response time 6) Max. switching frequency 7)
Light-switching ≤ 10 ms 50/s
Connection types
Plug Terminal connection
Approval VDE protection class 8) Circuit protection 9) Enclosure rating
PTB No. Ex97 D2034
Ambient temperature TA
Operation – 20 °C . . . + 50 °C Storage – 25 °C . . . + 70 °C Approx. 330 g Zinc die-cast housing
V A, C IP 65
Weight Housing material
1) Average service life 100,000 h 3) Limit values at TA = + 25 °C 4) May not exceed or fall short of 2) Supply with disconnector device EN 2 Ex VS tolerances
5) Without load 6) Signal transit time with resistive load 7) With light/dark ratio 1:1 8) Reference voltage 50 V DC
9) A = VS connections reverse-polarity protected C = Interference pulse suppression
Order information Type Part No. 1 011 974 WT 24-X 2101
Scanning distance 251 A2001 B1502 A2002 B150 4503 A2003 B1506000 (mm)5003 A B
WT 24-X 4101 WT 24-X 4601
30020150020001 011 973 1 013 1206%/90%151 10001500
Scanning distance on black, 6 % remission Scanning distance on grey, 18 % remission Scanning distance on white, 90 % remission WT 24-X 2101/X 4101 WT 24-X 4601
2000% of scanning distance1 2800102 18%/90% 3590%/90% 0(mm)500100015002000SENSICK CATALOGUE221