Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of SIMATIC 505

Manual · Siemens

SIMATIC 505

Manual7 pagesPDF 104 KB

Siemens ST 50 catalog chapter for SIMATIC 505 programmable controllers, with ordering data for CPUs, I/O modules such as the 505-4332.

What this file really is

The old site listed this file as a manual for the Siemens 505-4332. This is a short SIMATIC 505 chapter from the Siemens ST 50 product catalog, not a user manual for the 505-4332 module, which appears only as an order number.

Download the PDF104 KB

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

A chapter from the Siemens ST 50 catalog on the SIMATIC 505 programmable controllers. It describes the application and design of the system (compact design, intelligent I/O modules, distributed control, hot backup redundancy), programming tools, general technical specifications, and ordering data for TI525 to TI565 CPUs, power supplies, mounting racks, controllers, communications modules, manuals and digital and analog I/O modules, including order number PPX:505-4332.

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

A section of a 1998 Siemens catalog (ST 50) on the SIMATIC 505 programmable controllers, not a manual for one module. It gives a system overview, general technical specifications and ordering data for the TI525, TI535, TI545, TI555, TI560T, TI565T and 575 CPUs, racks, power supplies, I/O, communications and special modules, manuals and spares. The 505-4332 appears only as an order number in the list of digital input modules.

Document
SIMATIC 505 overview and ordering data, Siemens ST 50, 1998 p. 1
Digital I/O versions
Digital modules with 8, 16 or 32 inputs/outputs; relay modules with 8, 16 or 32 outputs p. 1
Digital input voltages
4 to 15 V DC, 24 V DC, 48/24 V DC, 24 V AC, 110 V AC and 220 V AC versions p. 5
Remote I/O distance
I/O modules and subracks up to 1000 m/3280 ft from the controller p. 1
CPUs
TI525: 10 KB, 512 digital/128 analog I/O; TI535: 40 KB, 1024 digital/1024 analog I/O p. 3
TI545 and TI555
TI545: 192 KB or 96 KB; TI555: 8192 digital/8192 analog I/O, 384 KB or 1920 KB p. 3
Power supply units
110/220 V AC or 24 V DC; 1 per mounting rack, 2 per redundant rack p. 3
TI505 racks
4, 8, 11 (redundant) or 16 slots p. 3
Operating temperature
0 to 60 °C p. 3
Humidity
Up to 95% humidity at 60 °C p. 3
Static discharge
Protected to 15 kV p. 3
Basic module
PPX:505-7101: 2 (RS232C/423) interfaces, 28 KB memory, 110 to 19200 bps; backup battery PPX:2587678-8010 p. 6
High-speed counters
2 counters, 4 inputs, 4 outputs, 50 kHz; or 6 counters, 8 inputs, 8 outputs, 100 kHz; 5 to 24 V DC p. 6
Programming software
SIMATIC TISOFT; SIMATIC APT p. 3

What this manual walks you through

  • Overview of the SIMATIC 505 design, I/O modules and distributed control p. 1
  • Hot backup redundancy with single-channel or two-channel I/O p. 2
  • Choosing programming software p. 3
  • General technical specifications p. 3
  • Ordering CPUs, power supplies and mounting racks for TI525 to TI565 p. 3
  • Ordering manuals, controllers for expansion units and communications modules p. 4, 5
  • Ordering digital, analog and special I/O modules p. 5, 6
  • Ordering spares and the 575 system p. 7

Good to know

  • The TI535 needs an additional IOCC in the basic mounting rack. p. 4
  • Some listed manuals are available in Europe only. p. 4

Questions this manual answers

How far can SIMATIC 505 remote I/O be from the controller?

The catalog states I/O modules and subracks can be placed as far as 1000 m/3280 ft from the controller. p. 1

How much memory does the TI545 have?

Two TI545 versions are listed: 192 KB with 2048 digital/1024 analog I/O and 64 controllers, or 96 KB with 1024 digital/1024 analog I/O and 16 controllers. p. 3

What software programs a SIMATIC 505 PLC?

The SIMATIC TISOFT package; SIMATIC APT is offered for those with previous knowledge of process automation. p. 3

Can the SIMATIC 505 run in a redundant hot backup setup?

Yes. TI560T/TI565T systems can be combined with TI505 I/O modules, with a hot backup card in the active and standby PLC. p. 2

The whole text · 1 part

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 71-7

The file

Revision and size

RevisionSiemens ST 50, 1998
PublisherSiemens
Pages7
PDF104 KB
TextText from the PDF itself.

The first pages · 3 of 7

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 7
Page 2
Page 2of 7
Page 3
Page 3of 7