Page 127
6–15 Discrete Input Modules
D3–08SIM, Input Simulator 8 10mA @ 9VDC 112mA max @ 24VDC
OFF to ON response
4–15 ms
ON to OFF response
4–15 ms
Terminal type
None
Status indicators
Switch side
Weight
3.0 oz. (85 g)
Discrete Input Modules
Inputs per module Base Power required
INPUT SIMULATOR D3–08SIM
4
1
5
2
6
3
7
0 1 2 3 4 5 6 7
Discrete Input Modules
0
Page 128
Page 129
Discrete Output Modules In This Chapter. . . .
17
Ċ Discrete Output Module Identification and Terminology Ċ Relay Arc Suppression - DC and AC Applications Ċ D3-08TD1, 24 VDC Output Module Ċ D3-08TD2, 24 VDC Output Module Ċ D3-16TD1-1, 24 VDC Output Module Ċ D3-16TD1-2, 24 VDC Output Module Ċ D3-16TD2, 24 VDC Output Module Ċ D3-04TAS, 110-220 VAC Output Module Ċ F3-08TAS, 250 VAC Isolated Output Module Ċ D3-08TA-1, 110-220 VAC Output Module Ċ D3-08TA-2, 110-220 VAC Output Module Ċ F3-16TA-2, 20-125 VAC Output Module Ċ D3-16TA-2, 110-220 VAC Output Module Ċ D3-08TR, Relay Output Module Ċ F3-08TRS-1, Relay Output Module Ċ F3-08TRS-2, Relay Output Module Ċ D3-16TR, Relay Output Module
Page 130
7–2 Discrete Output Modules
Discrete Output Module Identification and Terminology Discrete Output Module Status Indicators
This chapter contains I/O specification sheets for the DL305/FL305 discrete output modules. The following diagram shows the status indicator location for some of the most common discrete output modules.
Discrete Output Modules
Squeeze Tab
Squeeze Tab Removable Cover
Color Coding of I/O The DL305 family of I/O modules has a color coding scheme to help you identify whether the module is an input module, an output module or a special module. This Modules is done through a color bar indicator located on the front of each module below the part number. The following color scheme is used. Color Bar
➥
110VAC INPUT D3–16NA
I
Discrete Output Modules
I
0 1 2 3 C
0 1 2 3 4 5 6 7 C 0
4 5 6 7
0 1 2 3
4 5 6 7
II
Color Code Module Type Discrete/Analog Output Red Discrete/Analog Input Blue White Other
1 2 3 4 5 6 7
Output Modules Selection
II
Your output module selection depends on the field devices used and system performance requirements. The output module specifications in this chapter list the information which is needed for choosing the correct module for a field device and to assure it meets the system requirements. The following list defines the specifications listed in this chapter.
Page 131
7–3 Discrete Output Modules
Outputs Per Module
Indicates number of output points per module and designates current sinking, current sourcing, or either.
Commons Per Module Operating Voltage
Number of commons per module and their electrical characteristics.
Output Type
The output circuit can be a transistor, a triac, or a relay. The NPN or PNP transistor outputs are normally used in low voltage or high speed DC applications. Triac outputs are used in AC voltage applications. The Form A or C relay outputs are normally used where a wide voltage range is needed. Relay output modules are capable of carrying more current than a transistor or a triac output and can pass AC or DC voltages. The disadvantage of a relay module is the internal power consumption and the relay life expectancy.
Peak Voltage
Maximum voltage the output circuit can control.
AC Frequency
AC modules are designed to operating within a specific frequency range. 60 Hz is the standard AC frequency in the U.S., 50 Hz is common in other countries.
ON Voltage Drop
The voltage between the output point and common during an active ON with a load.
Maximum Current (Resistive) Maximum Leakage Current Maximum Inrush Current
The maximum current for an output with a resistive load.
Minimum Load
The minimum load across the output’s circuit for the circuit to operate properly.
Base Power Required
Power from the base power supply is used by the DL305 output modules and varies between different modules. The guidelines for using module power is explained in the power budget configuration section in chapter 4.
OFF to ON Response Time ON to OFF Response Time Terminal Type
The processing time the module requires to transition from an OFF to ON state.
Status Indicators
LEDs indicate the ON/OFF status of an input point. These LEDs are electrically located on either the logic side or the field device side of the output circuit.
Fuses
Indicates the current rating of the replaceable or non-replaceable fuse(s).
Relay Life
Amount of closures typical for a relay point before failure.
Weight
Indicates the weight of the module.
The operating voltage range of the output circuit.
Discrete Output Modules
The maximum current of the output circuit during an OFF state. The maximum current over a short period of time during the OFF to ON transition of a output point. It is greater than the normal ON state current and depends on the field device electrical characteristics.
Indicates whether the terminal type is a removable or non-removable connector or terminal.
Discrete Output Modules
The processing time the module requires to transition from an ON to OFF state.
Page 132
7–4 Discrete Output Modules
Discrete Output Modules
Relay Arc Suppression – DC and AC Applications FL305 High Current This application note describes the addition of external contact protection to high current isolated relay output modules. It supplements the wiring information for the Relay Output F3–08TRS–1 and F3–08TRS–2 relay output modules. Module Arc Suppression Adding external contact protection may extend a relays life beyond the number of operations listed. High current inductive loads such as clutches, brakes, motors, direct acting solenoid valves, and motor starters will benefit the most from external contact protection. Resistor and C (mF) = I2 / 10 Capacitor where x = (1 + 50 / E) R (W) = V / 10 Ix Selection Use peak AC values for I and V, see ”Peak Voltage and Current” below. Where I = Amperes of load current immediately prior to opening of contacts. Where E = Source voltage immediately prior to closing of contacts. R minimum = 0.5 W, 1/2 W C minimum = 0.001 mF, the voltage rating of C must be w E Resistor Tolerance For E < 70V, R may be 3 times indicated value. For 70V < E < 100V, R may be " 50% indicated value. For 100V < E < 150V,R may be " 10% indicated value. For E > 150V, R may be " 5% indicated value.
Discrete Output Modules
Peak Voltage and Current
Adding Contact Protection
The following equations can be used to determine Ipeak and V peak: Ipeak = Irms / .707 Vpeak = Vrms / .707
Alternating Current
Ipeak = Iave / .636
DC Rectified Alternating Current
If the contact is switching a DC inductive load, add a diode across the load as near to load coil as possible. Add the RC network across the relay contacts as close to the relay as possible.
Page 133
7–5 Discrete Output Modules
Resistor and Capacitor Nomogram
The nomogram shown below affords a convenient method of selecting the proper contact protection for P & B relays used in F3-08TRS-1 and F3-08TRS-2 modules. Example: Use a current (1) of 1.0 ampere and a voltage (E) of 50 volts. Capacitance (C ) in microfarads is found directly on the left side scale, opposite 1.0 amperes as 0.1. Resistance (R) in ohms is obtained using a straight edge. Locate 1.0 amperes (I) on the left side scale and 50 volts (E) on the center scale. Place the straightedge on these points. The junction of the straight edge and the right side determines R. In this example R is equal to 5.0 ohms.
R I
10,000 10
8,000
8 6,000 4,000 3,000 4
C
CURRENT AMPERES
3
.8 .6 .4
2
.3 .2
.1
1
.08
800 600 400 300
.6
200 5
E
6 8
.02 .4 .01 .008
.3
LOAD VOLTAGE
10
.004
300 200
20 30
.006
500 400
50
100
.2
.003 .002
100 80 60
40 30
20 .001
.1 .08 10 .06 8 6 .04 4 .03 3 2
.02
1 .01
(1) C = 12 / 10 microfarads (2) R = E / 10 Ix ohms
For DC. For AC, use peak values Where x = (1 + 50/E)
Discrete Output Modules
CAPACITOR MICROFARADS
.03
1,000
.8
.06 .04
2,000
RESISTANCE OHMS
1.0
Discrete Output Modules
6
Page 134
7–6 Discrete Output Modules
D3–08TD1, 24 VDC Output Module
Discrete Output Modules
Outputs per module Commons per module Operating voltage Output type
8 (current sinking) 2(internally connected) 5–24VDC NPN (open collector)
Peak voltage AC frequency ON voltage drop Max current
45VDC N/A 0.8V @ 0.5A 0.5A / point 1.8 / common
Max leakage current Max inrush current
0.1 mA @ 40VDC 3A / 20ms 1A / 100ms
Minimum load Base power required
1 mA 9V 20 mA Max 24V 3mA/pt. (24mA Max)
OFF to ON response ON to OFF response Terminal type Status indicators Weight Fuses
0.1 ms 0.1 ms Non-removable Logic Side 4.2 oz. (120 g) (2) One 3A per common Non–replaceable
Derating Chart for D3–08TD1 Points 8
24VDC OUTPUT D3–08TD1
6 0
4
1
5
2
6
C1
3
7
Internally Connected 5–24VDC + –
4 2
L L
0
1
C 1
L
2
3
0 1
4
5
2 3
6
7
4 5
0 0 32
Discrete Output Modules
L
L
L
10 20 30 40 50 60°C 50 68 86 104 122 140°F Ambient Temperature (°C/°F)
Output
L L
Optical Coupler
L
6 7
C2 C 2
3A Common + – 5–24VDC
24VDC – + Internal Power Supply
9V
Page 135
7–7 Discrete Output Modules
D3–08TD2, 24 VDC Output Module 8 (current sourcing) 2 (internally connected) 5–24VDC NPN Transistor (emitter follower)
Peak voltage AC frequency ON voltage drop Max current
40VDC N/A 1V @ 0.5A 0.5A / point 1.8A/ common
Max leakage current Max inrush current
0.1 mA @ 24VDC 3A / 20ms 1A / 100ms
Minimum load Base power required
1 mA 9V 30 mA Max 24V N/A
OFF to ON response ON to OFF response Terminal type Status indicators Weight Fuses
0.1 ms 0.1 ms Non-removable Logic Side 4.2 oz. (120 g) (2) One 3A per common Non–replaceable
Derating Chart for D3–08TD2
24VDC OUTPUT D3–08TD2
5–24VDC – +
0
4
1
5
2
6
Internally Connected
3
7
C1
C 1 0 1
Points 8 6 4 2 0
0
1
L
2
3
L
L
4
5
6
7
2 3
5–24VDC – + 4 5
3A Common
L L L
6 7 C 2
C2
Output L
Optical Coupler
9V
Discrete Output Modules
0 10 20 30 40 50 60°C 32 50 68 86 104 122 140°F Ambient Temperature (°C/°F)
L L
Discrete Output Modules
Outputs per module Commons per module Operating voltage Output type
Page 136
7–8 Discrete Output Modules
D3–16TD1–1, 24 VDC Output Module
Discrete Output Modules
Outputs per module Commons per module Operating voltage Output type
16 (current sinking) 2 (internally connected) 5–24VDC NPN transistor (open collector) 45VDC N/A 2V @ 0.5A 0.5A/ point 2A/ common
Peak voltage AC frequency ON voltage drop Max current Max leakage current Max inrush current
0.1mA @ 40VDC 3A / 20 ms 1A / 100 ms
Minimum load Base power required
1 mA 9V (40 mA Max) 3mA+2.3mA/ON pt. 24V 6 mA/ON pt. (96 mA Max)
OFF to ON response ON to OFF response Terminal type Status indicators Weight Fuses
0.1 ms 0.1 ms Removable Logic Side 5.6 oz. (160 g) (2) One 3A per common Non-replaceable
Derating Chart for D3–16TD1–1 Points 16
24VDC OUTPUT D3–16TD1–1
Internally Connected 5–24VDC + –
I
CI I 0
L
2
L
Discrete Output Modules
5–24VDC + –
L
L
5
L
7
2 3
Output L
4 5
3A
6
6
L
24VDC 9V
0
4
L
0 10 20 30 40 50 60°C 32 50 68 86 104 122 140°F Ambient Temperature (°C/°F)
7
2 3
0
1
1
L
0.5A
4
C
C 0
L
8
5
7
L
0.25A 0.35A
6
CII L
12
4
6 L
II
3
5
L
4 5 6 7
2
4
L
0 1 2 3
1
3
L
4 5 6 7
0 1
L
0 1 2 3
7
II
+ – 5–24VDC
Common