The text of a manual · part 24 of 36
DL305 User Manual, pages 227 to 236
Pages 227 to 236 of 356
The original document is the PDF (3.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the GE DL330 / D3-330, Fanuc DL330 / D3-330 and GE Fanuc DL330 / D3-330
Page 227
RLL PLUS Programming Basics
10–27
Designing a Program Using RLL PLUS Instructions As with most any application problem, a thorough understanding of the tasks combined with a good plan of execution often results in success. The RLL PLUS instructions provide an easy way to load the plan of execution directly into the CPU. The easiest way to make sure you understand the tasks is to make a flowchart. This is often the most critical part of creating a program that uses RLL PLUS instructions. There are a few simple steps you can follow to create a detailed flowchart. 1. Create a top-level flowchart. 2. Expand the flowchart by adding things that cause the transitions from step to step. 3. Add any actions that must occur in each step. 4. Add any conditions that control the actions. 5. Add any special monitoring or alarm steps that must be performed. 6. Assign numbers to the stages (steps). 7. Add the I/O instructions and addresses (input contacts, output coils, jump instructions, etc.) 8. Enter the program. Use DirectSOFT to The DirectSOFT programming package allows you to quickly and easily create programs with RLL PLUS instructions. The software has special features that allow Save Time you to create the flowcharts, add the transitions, actions, etc. Even if your programs are fairly small, DirectSOFT can make the job much easier.
RLLPLUS Programming Basics
Page 228
10–28
RLL PLUS Programming Basics
Step 1: Design a Top-level Flowchart
There are many different ways to design a flowchart of the application problem, but there are a few guidelines that will make the job easier. 1. Start with a “top-level” flowchart that breaks the operation sequence into simple pieces. 2. Each piece of the top-level flowchart should only represent one action. Resist the temptation to group several operations into one part of the flowchart. 3. Don’t try to add input or output addresses to the flowchart. Only use words to describe the things that are taking place. 4. Don’t worry about special conditions, such as stop conditions, alarms, etc at this point. These will be added later when you fully understand how the main part of the operations sequence is organized. You can draw the flowchart horizontally or vertically at any point in the design process, the choice is yours. Here’s an example top level flowchart for our simple one-station press. The flowchart breaks the program into logical steps
Wait for Start
RLLPLUS Programming Basics
One Cycle
Check for Part
Continuous Check Mode
Lock Clamp
Press Part
Unlock Clamp
Move Conveyor
Page 229
RLL PLUS Programming Basics
Step 2: Add Flowchart Transitions
10–29
Once you have designed the basic operating sequence you should determine the events that cause a transition from step to step. During this phase you may find things need to be added to the flowchart. All you’re really doing is adding more detail to the top-level flowchart. Once again, don’t try to use addresses yet. Concentrate on using words to describe the events taking place. The following flowchart adds the transition conditions for our one-station press. Wait for Start
Transition Symbol Press Start Switch
Check for Part
Part in place
No Part
Lock the Clamp
Jump to Move Conveyor
Clamp Limit Switch
Press the Part
Press Lower Limit Switch
Unlock the Clamp
Unclamp Limit Switch
Move Conveyor
Conveyor Index Limit Switch
Check 1-cycle Switch ON Jump to Wait for Start
Check 1-cycle Switch OFF Jump to Check for Part
RLLPLUS Programming Basics
Check Mode
Page 230
10–30
RLL PLUS Programming Basics
Step 3: Add Actions
After you determine the events that cause a transition from step to step you should add any actions that need to take place during the sequence. Again, don’t try to use addresses yet. Concentrate on using words to describe the actions taking place. The following flowchart adds the actions that take place during each part of the program. Wait for Start
Press Start Switch
Check for Part
Part in place
No Part Jump to Move Conveyor
Lock the Clamp Clamp On Clamp Limit Switch
Action Symbol
Press the Part Press Press Lower Limit Switch
Unlock the Clamp Clamp Off Unclamp Limit Switch
Move Conveyor Conveyor On Conveyor Index Limit Switch
RLLPLUS Programming Basics
Check Mode
Check 1-cycle Switch ON Jump to Wait for Start
Check 1-cycle Switch OFF Jump to Check for Part
Page 231
RLL PLUS Programming Basics
10–31
Step 4: Some actions may only take place if certain conditions are met. Examine the Add Conditions for program carefully to determine any conditions that should be added. The following flowchart adds any conditions for the actions that take place during each part of the Actions program. Wait for Start
Press Start Switch
Check for Part
Part in place
No Part Jump to Move Conveyor
Lock the Clamp Clamp On Clamp Limit Switch
Press the Part Press Press Lower Limit Switch
Unlock the Clamp Press Up
Clamp Off
Unclamp Limit Switch
Move Conveyor
Condition Symbol Conveyor On
Conveyor Index Limit Switch Check Mode
Jump to Wait for Start
Check 1-cycle Switch OFF Jump to Check for Part
RLLPLUS Programming Basics
Check 1-cycle Switch ON
Page 232
10–32
RLL PLUS Programming Basics
Step 5: Add Alarm or Monitoring Operations
Many people are tempted to add alarm or monitoring operations earlier in the flowchart design process. It is almost always easier to add them last because then you know how they should affect the main part of the program. The following flowchart adds an operation that monitors for the conditions that will stop the press. Wait for Start
Press Start Switch
Check for Part
Monitor for Stop
Stop Switch
Part in place
Reset all Operations
No Part Jump to Move Conveyor
Lock the Clamp Clamp On
Jump to Wait for Start
Clamp Limit Switch
Press the Part Press On Press Lower Limit Switch
Unlock the Clamp Press Up
Clamp Off
Unclamp Limit Switch
Move Conveyor Conveyor On Conveyor Index Limit Switch
RLLPLUS Programming Basics
Check Mode
Check 1-cycle Switch ON Jump to Wait for Start
Check 1-cycle Switch OFF Jump to Check for Part
Page 233
RLL PLUS Programming Basics
Step 6: Determine Stage Numbering
10–33
You can number the stages any way you would like, but it’s usually best to follow some type of sequence that matches the flow of the program. This makes it much easier to understand. There are a few guidelines we have used to determine the best numbering sequence. You don’t have to follow these guidelines, but they may help. You can typically find these types of operations in any program. S Sequential Operations, a certain sequence of events, one after the other. This is usually the main part of the program. It’s usually best to number these first. For example, you may want to always number these stages from 0 – 127 (octal). S Independent Operations, these operations usually only perform one task, such as activating a motor or turning on a horn. For example, you may want to number all independent operations starting from 130 – 147 (octal). S Alarm and Monitoring Operations, These operations usually monitor the main parts of the program. Since you may want to reset parts of the program during an alarm condition, it is usually best to number these last. This way you can use one Reset (RST) instruction to reset almost the entire program. Use stages 150 – 177 for alarming and monitoring stages. These guidelines are especially helpful if you have many different programs. By using a standard numbering scheme, you always know where to look for the various types of operations. The example shows how we assigned numbers for the example press. Notice we’ve also made a separate stage for the clamp. This was not an absolute requirement because there are several ways you could have done this. We just did it to show you an example of an independent operation.
RLLPLUS Programming Basics
Page 234
10–34
RLL PLUS Programming Basics
Initial Stage 0 Wait for Start
Press Start Switch
Stage 1 Check for Part
Stage 150 Monitor for Stop
Stop Switch
Part in place
Reset all Operations
No Part Jump to Move Conveyor
Stage 2 Lock the Clamp Clamp On
Jump to Wait for Start
Clamp Limit Switch
Stage 140 Clamp
Stage 3 Press the Part Clamp
Press On Press Lower Limit Switch Stage 4 Unlock the Clamp Press Up
Clamp Off
Unclamp Limit Switch Stage 5 Move the Conveyor Conveyor On Conveyor Index Limit Switch Stage 6 Check Mode
RLLPLUS Programming Basics
Check 1-cycle Switch ON Jump to Wait for Start
Check 1-cycle Switch OFF Jump to Check for Part
Page 235
RLL PLUS Programming Basics
Step 7: Assign I/O Addresses
10–35
The final step before you enter the program is to assign the I/O addresses and the destinations for any Jump, Set, or Reset instructions. Initial Stage 0 Wait for Start
Press Start Switch
Stage 1 Check for Part
Stage 150 Monitor for Stop
Stop Switch
000
010
Part in place Reset All Operations RST S0 – S140
Jump to Wait for Start
001
No Part Jump to Move Conveyor
Stage 2 Lock the Clamp
Clamp Limit Switch
Stage 140 Clamp
002
Clamp SET S140
Stage 3 Press the Part Clamp OUT 020
Press Lower Limit Switch
004
Press On OUT 021
Stage 4 Unlock the Clamp Press Up
Unclamp Limit Switch
005 003
Clamp RST S140
Stage 5 Move the Conveyor
006
Conveyor Index Limit Switch
Conveyor OUT 022
Stage 6 Check Mode
Check 1-cycle Switch OFF
007 Closed Jump to Wait for Start
007 Open Jump to Check for Part
RLLPLUS Programming Basics
Check 1-cycle Switch ON
Page 236
10–36
RLL PLUS Programming Basics
Step 8: Enter the Program
The following diagram shows how the program would look when viewed as a ladder program. ISG
A
Wait forStart
S000 Start
S1 JMP
SG
Clamp
S140
000 S150 JMP SG
Clamp OUT
Check for a Part
S001
Part Present
020 S2 JMP SG
001 Part Present
Check for Stop
S150 S6 JMP
Stop
001 SG
S000 JMP
Clamp the part
S002
Part Locked
Clamp SET S140 S3 JMP
002 SG
Press the part
S003
Press Down 021 Lower Limit
S4 JMP
004 SG
Unclamp the part
S004 Top Limit
Clamp RST S140
005 Part Unlocked
S5 JMP
003 SG
Index the conveyor
S005
Move Conveyor 022 Conveyor Moved
S6 JMP
006 SG
One cycle or automatic?
S006
RLLPLUS Programming Basics
A
S0 – S140 RST
010
One Cycle
S0 JMP
007 One Cycle 007
S1 JMP