The text of a spec sheet · part 1 of 5

Precision Regulator Series IR1000/2000/3000: Series IR1000/2000/3000 Precision Regulator

Pages 1 to 13 of 53, from Precision Regulator Series IR1000/2000/3000

The original document is the PDF (9.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the SMC IR3000-N04

Page 1

Precision Regulator Series IR1000/2000/3000

ARJ Series

Series IR1000

Model

Regulating pressure range

IR1000

0.005 to 0.2 MPa

IR1010

0.01 to 0.4 MPa

IR1020

0.01 to 0.8 MPa

IR2000

0.005 to 0.2 MPa

IR2010

0.01 to 0.4 MPa

IR2020

0.01 to 0.8 MPa

IR3000

0.01 to 0.2 MPa

IR3010

0.01 to 0.4 MPa

IR3020

0.01 to 0.8 MPa

Port size

Page

AR425 to 935

ARX AMR 1/8

ARM

717

ARP

Basic Type

Series IR2000

IR IRV VEX 1/4

SRH

717

SRP

Series IR3000

SRF VCHR ITV 1/4, 3/8, 1/2

IC

717

ITVX PVQ VEF VEP

VER

Air Operated Type

Series IR2000

VEA IR2120

0.01 to 0.8 MPa

1/4

VY1

717

VBA VBAT

AP100 Series IR3000

IR3120

0.01 to 0.8 MPa

1/4, 3/8, 1/2

717

713

Page 2

Precision Regulator

Series IR1000/2000/3000

Bracket and pressure gauge can be mounted from 2 directions Mounting is possible on either the front or the back.

Expanded regulating pressure range The maximum set pressure has been expanded from the conventional 0.7 MPa to 0.8 MPa.

Compact and lightweight IR1000 width 35 mm weight 140 g IR2000 width 50 mm weight 300 g IR3000 width 66 mm weight 640 g

Manifolding is possible 8 stations at the maximum Made to order specifications (Except Series IR2120, IR3000) OUT

714

OUT

OUT

OUT

OUT

Page 3

Compatible with new modular connection brackets (-X170) Can be combined with AF (Air filter) and AFM (Mist separator).

ARJ AR425 to 935

ARX AMR Attachments such as a pressure switch can be mounted as accessories

ARM ARP

Applicable modular size IR1000: 20 type IR2000: 30 type IR3000: 40 type

IR IRV VEX SRH

∗ Mount the standard type with a conventional connection bracket.

SRP

Relief flow characteristics

SRF

Possible to relieve (exhaust) air ranged 50 to 4000 L/min (ANR)

VCHR

Back pressure: 0.7 MPa

0.6 0.5 0.4 0.3 0.2

0.7

IR3010

0.6

IR401

0.5 0.4 0.3 0.2

0.1 600

500

400

300

200

100

0

Set pressure (MPa)

0.7

IR201

Set pressure (MPa)

IR2010

Back pressure: 0.7 MPa

0.1 5000

4000

3000

2000

1000

IC ITVX PVQ VEF VEP

VER VEA

0

Relief flow (L/min (ANR))

Relief flow (L/min (ANR))

ITV

VY1

Maximum set pressure

Port size

Air operated type

Basic type

Model

Specifications

IR100 IR200 IR300 IR2120 IR3120

Rc 1/8

Rc 1/4, Rc 3/8, - Rc 1/2, - 0.2 MPa 0.4 MPa 0.8 MPa

VBA VBAT

Made to Order Specifications

Series Variations, - Symbol

Specifications/Content

10-

Clean Series Copper-free and fluorine-free

AP100, - 20-, - 80-

Ozone resistant

-T

For high temperature, - -L

For low temperature (Except IR1000 type)

-X1

Non-grease specifications

-X170

Compatible with modular connection brackets (With modular adapter), - -X465

With digital pressure switch (ISE30A)

IRM

Manifold (Except Series IR2120, IR3000)

Note 1) For details, refer to page 724. Note 2) For part number combinations, consult SMC or its sales representative.

715

Page 4

Series IR1000/2000/3000 Application Example

Constant fluid pressure Balance and drive Accurate balance pressure setting TANK

• Since there is a large effective area for supply and exhaust pressure, setting can be done quickly. • Limits pressure fluctuation when driving a cylinder, maintaining excellent static and dynamic balance.

Accurate pressure setting, Sensitivity within 0.2% F.S. (Full Span) Tension control Contact pressure control Winding roller

Drive roller

Low friction cylinder

• Adapts to the cylinder's piston displacement, maintaining a constant pressure.

Multistage control of pressing force for workpiece (Wrapping machine) Leak test circuit

Measured object

Low friction cylinder

716

Page 5

Precision Regulator

RoHS

Series IR1000/2000/3000 Symbol

Basic type

Air operated type

ARJ AR425 to 935

Standard Specifications

ARX IR100

Max. supply pressure Min. supply pressure (1) Regulating pressure range

Air operated type

Basic type

Model

IR200

Set pressure + 0.05 MPa IR2000: 0.005 to 0.2 MPa IR2010: 0.01 to 0.4 MPa IR2020: 0.01 to 0.8 MPa

IR1000: 0.005 to 0.2 MPa IR1010: 0.01 to 0.4 MPa IR1020: 0.01 to 0.8 MPa

IR2120

IR3120

AMR

Set pressure + 0.05 MPa

Set pressure + 0.1 MPa

ARM

0.01 to 0.8 MPa

0.01 to 0.8 MPa

IR300 Max. 1.0 MPa Set pressure + 0.1 MPa IR3000: 0.01 to 0.2 MPa IR3010: 0.01 to 0.4 MPa IR3020: 0.01 to 0.8 MPa

ARP IR

Input signal (2) 0.01 to 0.8 MPa 0.01 to 0.8 MPa pressure Sensitivity (3) Within 0.2% of full span Repeatability (3) Within ±0.5% of full span Within ±1% of full span Linearity (4) Air consumption (5) 4.4 L/min (ANR) or less 4.4 L/min (ANR) or less 11.5 L/min (ANR) or less 4.4 L/min (ANR) or less 11.5 L/min (ANR) or less (At supply pressure of 1.0 MPa) Rc 1/4, 3/8, 1/2 Rc 1/4 Rc 1/4, 3/8, 1/2 Rc 1/4 Rc 1/8 Port size Rc 1/8 (2 locations) Pressure gauge port Ambient and fluid temperature –5 to 60°C (No freezing) 0.64 0.35 0.71 0.30 0.14 Weight (kg) Note 1) With the condition of no flow on the output side. Together with the set pressure, be sure to maintain a minimum differntial pressure of 0.05 MPa for models IR1000 and IR2000, and 0.1 MPa for model IR3000. Note 2) Applicable only to air operated types IR2120 and IR3120. The basic type is excepted. Note 3) Characteristic values do not contain any secular change and temperature change. Note 4) Indicates the linearity of the output pressure with respect to the input signal pressure. Note 5) Air is normally being discharged to the atmosphere from a bleed hole or an exhaust port.

How to Order

IR 2 0 0 0 2 3

IR2000 IR3000

0 1

Nil N F ∗ Option

0 0.005 to 0.2 MPa 1 0.01 to 0.4 MPa 0.01 to 0.8 MPa 2 Note) Air operated type is model IR2120 only.

For series IR3000 0 0.01 to 0.2 MPa 1 0.01 to 0.4 MPa 0.01 to 0.8 MPa 2 Note) Air operated type is model IR3120 only.

01 02 03 04

Rc NPT∗ G∗

Application

IR1000 IR2000 IR3000

1/8 1/4 3/8 1/2

Accessory ∗ Pressure gauge is included, (but not assembled).

Nil B

None With bracket With pressure gauge∗ Note) For the low temperature environment, no combinations with the pressure gauge “G” are available. Note) G

SRF VCHR ITV IC

VER VEA VY1

Suffix 2 Nil Note)

R

Port size

Symbol size, For high temp. enviroments (–5 to 100˚C) (Max. 80˚C with pressure gauge.) Note) L For low temp. enviroments (–30 to 60˚C) Note) Except IR1000 type. For IR3000 type, the combination of “L” and “X1” is not available. T

Thread type

SRP

VEF VEP

Nil

Regulating pressure range For series IR1000/2000

SRH

PVQ Suffix 1

Basic type (Handle) Air operated type (Series IR2000/3000 only)

VEX

ITVX

02

Precision regulator Body size Type of setting 1 IR1000

IRV

VBA VBAT, Pressure gauge, Bracket, Name plate, Mounting on the opposite side

AP100

Note) The standard mounting position of the pressure gauge is on the front, when viewing the regulator with the SUP side to the left and OUT side to the right.

Made to Order Specifications (Refer to page 724) Symbol Specifications/Content X1 Non-grease specifications X170 Compatible with modular connection brackets (Refer to page 718) X465 With digital pressure switch (ISE30A) ∗ 1 Add prefix (10-) for the clean room specification. ∗ 2 Add prefix (20-) for the copper-free and fluorine-free specification. ∗ 3 Add prefix (80-) for the ozone-resistant specification. ∗ 4 Manifold specification is available for IR1000 and IR2000. (Except IR2120 and IR3000)

717

Page 6

Series IR1000/2000/3000 Specification Combinations : Standard specifications : Combination possible

: Combination not possible

Series IR3000

Accessory

Option

Series IR2000

Series IR1000

Specifications

Symbol

Standard specifications

Applicable model

Set pressure Max. 0.2 MPa

0

Set pressure Max. 0.4 MPa

1

Set pressure Max. 0.8 MPa

2

Connection Rc 1/8

01

Connection Rc 1/4

02

Connection Rc 3/8

03

Connection Rc 1/2

04

Bracket

B

Pressure gauge

G

IR1000 IR1010 IR1020

IR2000 IR2010 IR2020

IR2120

IR3000 IR3010 IR3020

IR3120

Pressure gauge reverse mounted

R

Connection NPT 1/8

N01

Connection NPT 1/4

N02

Connection NPT 3/8

N03

Connection NPT 1/2

N04

Connection G 1/8

F01

Connection G 1/4

F02

Connection G 3/8

F03

Connection G 1/2

F04

-X170

IR20 0-

Modular and Accessory Combinations Applicable model

Description

IR10 0-

-X170

IR30 0-

-X170

1. Air filter

AF20

AF30

AF40

2. Mist separator

AFM20

AFM30

AFM40

3. Interface

Y200

Y300

Y400

4. Interface with bracket

Y200T

Y300T

Y400T

Note 1) Use the Made-to-Order product (IR -X170) for modular connections. The interface and interface with bracket listed above cannot be connected to the standard type. Use a conventional connection interface when connecting the standard type with modular connections. Note 2) The Made-to-Order product (IR-X170) is the product number with the modular adaptor attached to the standard product. The modular adaptor that has not been assembled to the product is shipped together. For the recommended tightening torque necessary to connect the modular adaptor, refer to page 591. When connecting the modular adaptor, please order applicable products or accessories separately.

Note 3) Product numbers with the bracket are not available for IR-X170. As the interface with the bracket is used, it is not necessary to attach the bracket to the IR.

<Combination example> ≅225

≅173

2

≅169

OUT

G

EXH

≅133

3

≅97

OUT eInterface rInterface with bracket

2

≅130

G

30.2 wAFM20

40.7 wAFM30 qAF20 qAF30

IR10 0- -X170

IR20 0- -X170 qAF40

IR30 0- -X170

Accessory (Option)/Part No. Description Bracket Pressure gauge ∗2 ∗3

50 wAFM40

Part no.

IR1000

IR1010

IR1020

IR2000

P36201023 G33-2-01

G33-4-01

IR2010

IR2020/2120

IR3000

G43-10-01

G43-2-01

P36202028 G33-10-01

G43-2-01

G43-4-01

IR3010

IR3020/3120

G43-4-01

G43-10-01

P362030-20∗1

∗1 A bracket and two mounting screws (M5 x 35) To mount the bracket, remove two body screws (M5 x 30) on the name plate on the opposite side and replace the attached two bracket mounting screws (M5 x 35). ∗2 Accuracy ±3% (Full span), Accuracy guarantee temperature range: 23±5°C ∗3 When ordering this pressure gauge individually, the sealant is not applied to the connection male thread. So, apply the sealing tape or sealant to the screw thread before use.

718

Page 7

Precision Regulator Series

IR1000/2000/3000

Construction IR1000

IR2000 i i

IR3000 q o q o i i

!5Fixed throttle

!5 SUP side passage

OUT side passage o

SUP side passage e w r

Exhaust

Valve guide w

AMR y

ARM

OUT(2)

ARP

Bleed

Diaphragm (C) OUT(2)

SUP(1)

Exhaust Valve

!2 !0

Main valve

!0

IR t

IRV

Valve guide

Valve guide

IR2120

IR3120

Working principle (For IR2000) When the setting knob is turned, the nozzle is closed by the flapper allowing the supply air that flows in from the upstream side to pass through the fixed throttle. It then acts on diaphragm B as nozzle back pressure, the main valve is pushed down by the generated force, and the supply pressure flows out to the downstream side. The air pressure that flows in acts on diaphragm C. While opposing the force generated by diaphragm B it also acts on diaphragm A, opposing the compression force of the setting spring and becomes the set pressure. If the set pressure rises too high, diaphragm A is pushed up, the interval between the flapper and the nozzle widens, the nozzle back pressure drops, the balance of diaphragms B and C is broken, the main valve closes, the exhaust valve opens and the excess pressure from the downstream side is discharged to the atmosphere. In this way fine pressure variations are detected by the nozzle/flapper type pilot mechanism, and precise pressure adjustment is performed.

ARX

!1 !3 !2

Diaphragm (B) Exhaust u r !0 q

Nozzle

SUP(1)

OUT(2)

ARJ AR425 to 935

Steel ball w

OUT side passage

Diaphragm (A)

Bleed u

SUP side passage

Setting knob q

SUP(1)

!5

OUT side passage q

Bleed

!4

VEX q o o i

!5

!5 SUP side passage

SUP side passage

ITV

IN Bleed q w

!1 !3 !2 y

ITVX

SUP(1)

OUT(2)

PVQ

Bleed

OUT(2)

u !0

!2 !0 Valve guide

Replacement Parts

SRF VCHR

IN

SUP(1)

IC

VEF VEP t

Valve guide

IR2120

VER

No.

Description

Material

IR100 Part no.

Qty.

IR200 Part no.

Qty.

IR300 Part no.

Qty.

Part no.

Qty.

Part no.

Qty.

1

Diaphragm assembly

NBR, other

P362010-1

1

P362020-2

1

P362020-2

1

P362020-13

1

P362020-13

1

2

Diaphragm assembly

NBR, other

P362010-2

1

P362020-5

1

P362030-1

1

P362020-5

1

P362030-1

1

3

Diaphragm

NBR, other, - - - P36202019

1, - Valve

Stainless steel, NBR

P36201058

1

P36202019 P36202068#1

1

4

1, - P36202068#1

1, - 5

Valve

Brass, NBR, - - - P36203009#1

1, - P36203009#1

1

6

Valve

Brass, NBR, - - - P36203010#1

1, - P36203010#1

1

7

Damper

NBR, other

P36201021

1

P36202026

1, - P36202026

1, - 8

O-ring

H-NBR

ø2.5 x 1.05

3

ø1.42 x 1.52

2, - ø1.42 x 1.52

2, - IR3120

9

O-ring

NBR, - ø4.5 x 1

3

ø4.5 x 1

1

ø4.5 x 1

3

ø4.5 x 1

1

10

O-ring

NBR

ø10 x 1.3

1

JISB2401P11

1

ø27.8 x 1.5

1

JISB2401P11

1

ø27.8 x 1.5

1

11

O-ring

NBR, - - 12

O-ring

NBR, - - 13

Seal (A)

NBR, - 14

Seal (B)

NBR, 15

Fixed throttle

Stainless steel

P36202018

Repair kit no. (A set of above nos. q to !5.)

KT-IR1000, - JISB2401P5 Note 2) 1, - JISB2401P16 Note 2) 2, - JISB2401P5 Note 2) 1, JISB2401P16 Note 2) 2 P36203015, 1, - P36203015

1, - - P36203016

3, - P36203016

3

1

P36202018

1

P36203017

1

P36202018

1

P36203017

1

KT-IR2000

SRH SRP

OUT side passage

OUT side passage q e w q o

!4

KT-IR3000

KT-IR2120

KT-IR3120

Note 1) The replacement parts are shipped with the repair kit number. Note 2) Use mini-flick type.

719

VEA VY1 VBA VBAT

AP100

Page 8

Series IR1000/2000/3000 Dimensions IR100-01

IR200-02 0.5

ø1

Mounting hole

50 36

Mounting hole Bracket (Option)

Panel mounting hole

Pressure gauge (Option) Panel ∗ When mounting on a panel, refer to page 725 in Specific Product Precautions.

Panel ∗ When mounting on a panel, refer to page 725 in Specific Product Precautions. 4.5

2.5

ø1

Max.4

Pressure gauge (Option)

2

Panel mounting hole

30

25

Bracket (Option)

Max.4

2

42 28

M5 x P0.5

M6 x P0.5

ø43

2 x Rc 1/8 Port size

50

2 x Rc 1/8 Pressure gauge port

2 x Rc 1/8 Pressure gauge port

50 2

IR2120-02

Bracket (Option) Pressure gauge (Option)

2.5

ø1

5.5 .5

Panel mounting hole

76

2.3

82 60

50 ≅60

2 x Rc 1/4 Port size

Mounting hole Bracket (Option) Pressure gauge (Option)

EXH(3)

OUT(2)

M5 depth 7

IN

Bleed

EXH(3)

OUT(2)

22

SUP(1)

≅144

5.

9

76

2 x Rc 1/8 Pressure gauge port

Rc 1/2 Exhaust port 2 x Rc 1/4 to 1/2 Port size

ø43

≅68

ø1

66 66

5

22

SUP(1)

2 x Rc 1/8 Pressure gauge port

48

ø43

IR3120-0 ≅148

ø1 5.5

Bleed

Exhaust OUT(2) 50

M6 x P0.5

75 83 ≅119

Bleed SUP(1)

∗ When mounting on a panel, refer to page 725 in Specific Product Precautions.

9

M5 depth 7

IN

ø43

Pressure gauge (Option) Panel

ø9

Max.4

Bracket (Option)

48

2.3

Mounting hole

2 x Rc 1/4 Port size

Mounting hole

36

30

IR300-0 82 60

50

≅60

(17.7)

≅43

35

(17.7)

35

EXH

63 71

Exhaust OUT(2)

SUP(1)

≅124

ø9 Bleed

9.5

OUT(2)

ø30

Bleed SUP(1)

≅92

46 52.5

.5

ø8 .5

5.5

66

≅68 2 x Rc 1/8 Pressure gauge port

720

66

Rc 1/2 Exhaust port 2 x Rc 1/4 to 1/2 Port size

Page 9

Precision Regulator Series

IR1000/2000/3000

Series IR1000 ∗ The operating conditions or external disturbance may affect each of the characteristics. So, the characteristic values shown below are not guaranteed.

Flow Characteristics

Relief Characteristics

Pressure Characteristics

IR1000-01

IR1000-01

IR1000-01

Supply pressure: 0.5 MPa

Back pressure: 0.5 MPa

Set pressure (MPa)

0.4

0.15

0.3 0.1 0.2 0.05

Set pressure (MPa)

0.5

0.2

Set pressure P2 (MPa)

∗ Testing methods conform to JIS B 8372.

Supply pressure: 0.7 MPa Set pressure: 0.2 MPa Flow rate: 0 L/min (ANR)

0.204

ARJ

0.202

AR425 to 935 Set point

ARX

0.200

AMR

0.198

ARM

0.1 0.196 50

100

150

200

250

140

Flow rate (L/min (ANR))

IR1010-01

120

100

80

60

40

20

Supply pressure: 0.7 MPa

IR1010-01

0

0.3

0.5 0.4

0.2

0.3

Set pressure (MPa)

0.7 0.6

0.204

VEX

150

200

250

300

350

200

IR1020-01

160

120

80

40

Set point

IR1020-01

0.198

SRF

0.196

VCHR 0

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Supply pressure P1 (MPa)

1.0

0.7

0.8 0.6

0.7

0.5

0.6

0.4

0.5 0.4

0.3

0.3

0.2

ITVX PVQ

0.202

VEF VEP

Set point

0.200

VER

0.198

VEA

0.2

0.1

0.1 100

200

300

400

Flow rate (L/min (ANR))

500

300

200

100

Relief flow rate (L/min (ANR))

0

ITV IC

IR1020-01 0.204

0.9

Set pressure (MPa)

Set pressure (MPa)

SRP

0

Back pressure: 1.0 MPa

0.8

0

0.200

Relief flow rate (L/min (ANR))

Supply pressure: 1.0 MPa

SRH

0.202

Set pressure P2 (MPa)

100

Flow rate (L/min (ANR))

IR IRV

0.1

50

ARP

IR1010-01

0.2

0.1

0

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Supply pressure P1 (MPa)

Back pressure: 0.7 MPa

0.4

Set pressure (MPa)

0

Relief flow rate (L/min (ANR))

Set pressure P2 (MPa)

0

VY1

0.196 0

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Supply pressure P1 (MPa)

VBA VBAT

AP100

721

Page 10

Series IR1000/2000/3000

Series IR2000 ∗ The operating conditions or external disturbance may affect each of the characteristics. So, the characteristic values shown below are not guaranteed.

Flow Characteristics

Relief Characteristics

Pressure Characteristics

IR2000-02

IR2000-02

∗ Testing methods conform to JIS B 8372.

IR2000-02

Supply pressure: 0.5 MPa

Back pressure: 0.5 MPa

0.204

0.3 0.1

0.2

0.05

0.1

Set pressure P2 (MPa)

0.4 0.15

Set pressure (MPa)

Set pressure (MPa)

0.5 0.2

Supply pressure: 0.7 MPa Set pressure: 0.2 MPa Flow rate: 0 L/min (ANR)

0.202

Set point

0.200

0.198

0.196 0

100

200

300

400

500

600

400

700

Flow rate (L/min (ANR))

IR2010-02

Supply pressure: 0.7 MPa

300

200

100

0

0

IR2010-02

Supply pressure P1 (MPa)

Back pressure: 0.7 MPa

IR2010-02

0.7

0.5

0.3

0.4 0.2

0.3

0.204

0.2

0.1

Set pressure P2 (MPa)

0.6

Set pressure (MPa)

Set pressure (MPa)

0.4

0.1 100 200 300 400 500 600 700 800 900

500

Flow rate (L/min (ANR))

IR2020-02

Supply pressure: 1.0 MPa

400

300

200

100

IR2020-02

IR2020-02 0.204

0.7

0.5

0.6

0.4

0.5 0.4

0.3

0.3

Set pressure P2 (MPa)

0.8

0.202

Set point

0.200

0.198

0.2

0.1

0.1 200

400

600

800

1000 1200 1400

1000

Flow rate (L/min (ANR))

IR2120-02

Supply pressure: 1.0 MPa

800

600

400

200

0.196

0

0

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Relief flow rate (L/min (ANR))

IR2120-02

Supply pressure P1 (MPa)

Back pressure: 1.0 MPa

IR2120-02

1.0 0.204

0.9 0.7

0.8

0.6

0.7

0.5

0.6

0.4

0.5 0.4

0.3

0.3

0.2

Set pressure P2 (MPa)

0.8

Set pressure (MPa)

Set pressure (MPa)

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Supply pressure P1 (MPa)

0.9

0.2

Set pressure (MPa)

0.198

1.0

0.6

0.202

Set point

0.200

0.198

0.2

0.1

0.1 200

400

600

800

1000

1200 1400

Flow rate (L/min (ANR))

722

0.200

0

Back pressure: 1.0 MPa

0.7

0

Set point

Relief flow rate (L/min (ANR))

0.8

0

0.202

0.196

0

Set pressure (MPa)

0

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Relief flow rate (L/min (ANR))

1000

800

600

400

200

Relief flow rate (L/min (ANR))

0

0.196 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Supply pressure P1 (MPa)

Page 11

Precision Regulator Series

IR1000/2000/3000

Series IR3000 ∗ The operating conditions or external disturbance may affect each of the characteristics. So, the characteristic values shown below are not guaranteed.

Flow Characteristics

Relief Characteristics

Pressure Characteristics

IR3000-03

IR3000-03

IR3000-03

Supply pressure: 0.5 MPa

Back pressure: 0.5 MPa

Set pressure (MPa)

0.4 0.15 0.3 0.1 0.2 0.05

Set pressure (MPa)

0.5

0.2

Set pressure P2 (MPa)

∗ Testing methods conform to JIS B 8372.

Supply pressure: 0.7 MPa Set pressure: 0.2 MPa Flow rate: 0 L/min (ANR)

0.204

ARJ

0.202

AR425 to 935

Set point

0.200

ARX

0.198

AMR

0.196

ARM

0.1 0.194 1000

0

2000

3000

4000

3500 3000 2500 2000 1500 1000

Flow rate (L/min (ANR))

IR3010-03

500

Supply pressure: 0.7 MPa

IR3010-03

0.4 0.2

0.3

Set pressure P2 (MPa)

0.5

Set pressure (MPa)

0.6 0.3

0.2

0.1

0.1 2000

3000

4000

5000

6000

4000

Flow rate (L/min (ANR))

IR3020-03

3000

2000

1000

IRV

0.202

VEX

0.200

Set point

SRP

0.196

SRF

0

0

IR3020-03

VCHR 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Supply pressure P1 (MPa)

Back pressure: 1.0 MPa

0.7

0.9

0.6

0.8 0.7

0.5

0.6

0.4

0.5

0.3

0.4 0.3

0.2

Set pressure (MPa)

1.0

IR3020-03

ITVX

0.202

PVQ

0.200

Set point 0.198

VEF VEP

0.196

VER

3000

4000

5000

6000

6000

Flow rate (L/min (ANR))

IR3120-03

5000

4000

3000

2000

1000

Set pressure (MPa)

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Relief flow rate (L/min (ANR))

Supply pressure: 1.0 MPa

IR3120-03

Supply pressure P1 (MPa)

Back pressure: 1.0 MPa

0.8

1.0

0.7

0.9

0.6

0.8 0.7

0.5

0.6

0.4

0.5

0.3

0.4 0.3

0.2

0.1 1000

2000

3000

4000

5000

Flow rate (L/min (ANR))

6000

6000

5000

4000

3000

2000

1000

Relief flow rate (L/min (ANR))

0

0.204

AP100

0.202 0.200

Set point 0.198 0.196 0.194 0

VY1 VBA VBAT

IR3120-03

0.2

0.1 0

0

0

Set pressure P2 (MPa)

2000

VEA

0.194

0.1 1000

Set pressure (MPa)

0

ITV IC

0.204

0.2 0.1

SRH

0.198

Relief flow rate (L/min (ANR))

Supply pressure: 1.0 MPa

0.8

Set pressure (MPa)

0.204

0.194

Set pressure P2 (MPa)

1000

ARP IR

IR3010-03

0.7

0

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Supply pressure P1 (MPa)

Back pressure: 0.7 MPa

0.4

Set pressure (MPa)

0

0

Relief flow rate (L/min (ANR))

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Supply pressure P1 (MPa)

723

Page 12

Series IR1000/2000/3000

Made to Order Specifications:

Please contact SMC for detailed dimensions, specifications, each part number and lead times.

1 Clean Series

6 With Digital Pressure Switch

10

With digital pressure switch (model no: ISE30A-01--ML). Mount a digital pressure switch into the connection port for pressure gauge, as it is not mounted at the time of shipment.

Standard model no. Note) Please contact SMC if a product with pressure gauge is desired.

Clean Series Specifications Cleanliness Bleed hole EXH port Grease

Class 10000 With M5 fitting (Applicable tubing O.D. ø6) IR1000/2000: With M5 fitting (Applicable tubing O.D. ø6) IR3000: Rc 1/2 female thread Fluorine grease

2 Copper-free and Fluorine-free External and internal copper parts are changed to stainless steel or aluminum.

20

Standard model no. Note) Please contact SMC if a product with pressure gauge is desired.

Copper-free and Fluorine-free

Specifications Made to order part no. Set pressure range (MPa) Pressure Desolution of setting and display (MPa) switch

Power supply voltage Current consumption

–X465 –0.1 to 1 0.001 12 to 24 VDC ±10%, Ripple (p-p) 10% or less (With reverse connection protection) 40 mA or less

How to Order

Standard model no. Note)

X465 A

Note) Except for symbol “G”

With digital pressure switch Switch specifications

Note 1) Please contact SMC separately for details about the external dimensions, etc. Note 2) For details on handling digital pressure switch and specifications, refer to page 767 of Best Pneumatics No.6. Note 3) Digital pressure switch is packed togther.

Symbol

A B C D

Output specifications NPN open collector 1 output PNP open collector 1 output NPN open collector 1 output + Analog voltage output NPN open collector 1 output + Analog current output

7 Manifold Specifications (Except type IR2120 and series IR3000) 3 Ozone Resistant

2 to 8 station manifold type regulators. (Please contact SMC regarding 9 or more stations.)

Fluoro rubber is used for rubber seal materials.

80

IRM 10

Standard model no.

3 G Set pressure and quantity 0 1 2

Ozone resistant

4 For High/Low Temperature Environments T Stations

For high/low temperature environments LNote)

Specifications

For high temperature For low temperature

10 20

Assembly is performed in an ordinary environment without using grease. However, since parts are not washed, they are not completely oil-free.

Standard model no.

X1 Non-grease specifications

724

8 stations

IR1000 IR2000

Manifold type regulator Specifications Stations Port

5 Non-grease Specifications

8

Body size

Note) Except IR1000 type. For IR3000 type, the combination of “L” and “X1” is not available.

T L Symbol Environment For high temp. environments For low temp. environments –5 to 100°C Ambient –30 to 60°C temperature (Max. 80°C with pressure gauge) Rubber material Fluororubber Special NBR

2 stations

...

T

2 ...

Standard model no.

Set pressure

0.2 MPa setting 1 to n pcs. 0.4 MPa setting 1 to n pcs. 0.8 MPa setting 1 to n pcs.

Example 1) 0.4 MPa setting with 6 stations IRM10-6G-16 Example 2) 0.2 MPa setting 2 pcs., 0.4 MPa setting 2 pcs., 0.8 MPa setting 1 pc. with 5 stations IRM20-5G-021221

Accessory (Pressure gauge)∗ Nil

None IR1000: G33--01 IR2000: G43--01 ∗ Accessory (pressure gauge) is included, (but not assembled). G

Thread type (Thread on the manifold base) Nil N F

Rc NPT G

2 to 8 stations Common SUP IR1000: 1/4, IR2000: 1/2 Individual OUT IR1000: 1/8, IR2000: 1/4 Individual EXH (From IR body) 0.2 MPa, 0.4 MPa and 0.8 MPa settings can be combined.

Accessory G33--01 (IR1000), G43--01 (IR2000) (Pressure gauge) Note 1) Regulators to be manifolded are counted starting from stations 1 on the left side with the OUT ports in front. Note 2) When regulators with a different set pressure are manifolded, viewing OUT ports from front, the low pressure range is installed on the left side and high pressure range is on the right side. In case of the “Example 2)” above mentioned, stations 1 and 2 are of 0.2 MPa setting, stations 3 and 4 are of 0.4 MPa setting, and station 5 is of 0.8 MPa setting. Note 3) Please consult with SMC when a blanking plate is needed.

Page 13

Series IR1000/2000/3000

Specific Product Precautions

Be sure to read before handling. Refer to front matter 43 for Safety Instructions and pages 365 to 369 for Precautions on every series.

Air Supply

Operation

Caution

Warning 1. If the drain removal from air filter and mist separator is missed, drain will be flown out to the outlet side and may result in a malfunction of the pneumatic equipment. When removing drain is difficult, use of a filter with an autodrain is recommended.

Caution 1. If the supply pressure line contains drain or particlate, etc., the fixed throttle can become clogged leading to malfunction, and therefore, in addition to an air filter (SMC Series AF) be sure to use a mist separator (SMC Series AM, AFM). Refer to pages 2 and 3 regarding air quality. 2. Never use a lubricator on the supply side of the regulator, as this will positively cause the fixed throttle to become clogged and result in a malfunction. If lubrication is required for terminal devices, connect a lubricator on the output side of the regulator.

Maintenance

Warning 1. When the valve guide (refer to construction drawing on page 719) is to be removed during maintenance, first reduce the set pressure to “0” and completely shut off the supply pressure. 2. When a pressure gauge is to be mounted, remove the plug after reducing the set pressure to “0”.

Precautions for IR100 only

Warning

ARJ

1. Do not use a precision regulator outside the range of its AR425 specifications as this can cause failure. (Refer to to 935 specifications.) 2. When mounting is performed, make connections while ARX confirming port indications. 3. Screw a panel nut with the recommended proper torque AMR when mounting onto a panel. Looseness or faulty sealing will occur if tightening torque is ARM insufficient, while thread damage will result if the torque is excessive.

Recommended Proper Torque IR1000 IR2000 12.5 21

(N·m)

IR3000 21

4. If a directional switching valve (solenoid valve, mechanical valve, etc.) is mounted on the supply side of the regulator and repeatedly switched ON and OFF, wear of the nozzle/flapper section will be accelerated and a discrepancy in the setting value may occur. Therefore, avoid using a directional switching valve on the supply side. In the event a directional switching valve will be used, install it on the output side of the regulator. 5. The accessory pressure gauge is supplied with the regulator in the unassembled status. Before using the regulator, be sure to install the pressure gauge at the gauge port of the regulator. At this time, the recommended tightening torque of the pressure gauge is 7 to 9 N·m. 6. Air is normally released from the bleed hole (the hole on the side of the body’s mid-section). This is a necessary consumption of air based on the construction of the precision regulator, and is not an abnormality. 7. Make sure to tighten the lock nut after pressure adjustment.

Precautions for IR300, IR3120 only

1. When remounting the valve guide after removing it for maintenance, use a tightening torque of no more than 0.6 N·m. Since the valve guide on this product is made of resin, there is a danger of damage if tightened with a torque exceeding the prescribed value.

Handling

Caution 1. Do not apply force when transferring, mounting and dropping the regulator with a pressure gauge. This may cause misalignment of the pressure gauge pointer.

ARP IR IRV VEX

SRH SRP SRF VCHR ITV IC ITVX PVQ

Caution 1. The supply pressure is relatively high (approx. 0.5 MPa or more), the set pressure is low (approx. 0.1 MPa or less), and when operated with the output side released to the atmosphere, there may be pulsations in the setting pressure. In this kind of situation, operate with the supply pressure reduced as much as possible, or increase the set pressure somewhat and restrict the output line (add and adjust a stop valve, etc.). 2. The capacity of the output side is large, and when used for the purpose of a relief function, the exhaust sound will be loud when being relieved. Therefore, operate with a silencer (SMC Series AN) mounted on the exhaust port (EXH port). The connection is Rc 1/2.

Precautions for IR2120, IR3120 (air operated type) only

Caution 1. Since the output types of IR2120 and IR3120 are the same pressure as the input signal pressure, select a type of regulator (general purpose or precision type) for input signal pressure adjustment according to the application. 2. The screw on the topmost section is a zero point adjustment screw which is locked at the factory and requires no adjustment for operation.

725

VEF VEP

VER VEA VY1 VBA VBAT

AP100