The text of a spec sheet · part 1 of 5
Precision Regulator Series IR1000/2000/3000: Series IR1000/2000/3000 Precision Regulator
Pages 1 to 13 of 53, from Precision Regulator Series IR1000/2000/3000
The original document is the PDF (9.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the SMC IR3000-N04
Page 1
Precision Regulator Series IR1000/2000/3000
ARJ Series
Series IR1000
Model
Regulating pressure range
IR1000
0.005 to 0.2 MPa
IR1010
0.01 to 0.4 MPa
IR1020
0.01 to 0.8 MPa
IR2000
0.005 to 0.2 MPa
IR2010
0.01 to 0.4 MPa
IR2020
0.01 to 0.8 MPa
IR3000
0.01 to 0.2 MPa
IR3010
0.01 to 0.4 MPa
IR3020
0.01 to 0.8 MPa
Port size
Page
AR425 to 935
ARX AMR 1/8
ARM
717
ARP
Basic Type
Series IR2000
IR IRV VEX 1/4
SRH
717
SRP
Series IR3000
SRF VCHR ITV 1/4, 3/8, 1/2
IC
717
ITVX PVQ VEF VEP
VER
Air Operated Type
Series IR2000
VEA IR2120
0.01 to 0.8 MPa
1/4
VY1
717
VBA VBAT
AP100 Series IR3000
IR3120
0.01 to 0.8 MPa
1/4, 3/8, 1/2
717
713
Page 2
Precision Regulator
Series IR1000/2000/3000
Bracket and pressure gauge can be mounted from 2 directions Mounting is possible on either the front or the back.
Expanded regulating pressure range The maximum set pressure has been expanded from the conventional 0.7 MPa to 0.8 MPa.
Compact and lightweight IR1000 width 35 mm weight 140 g IR2000 width 50 mm weight 300 g IR3000 width 66 mm weight 640 g
Manifolding is possible 8 stations at the maximum Made to order specifications (Except Series IR2120, IR3000) OUT
714
OUT
OUT
OUT
OUT
Page 3
Compatible with new modular connection brackets (-X170) Can be combined with AF (Air filter) and AFM (Mist separator).
ARJ AR425 to 935
ARX AMR Attachments such as a pressure switch can be mounted as accessories
ARM ARP
Applicable modular size IR1000: 20 type IR2000: 30 type IR3000: 40 type
IR IRV VEX SRH
∗ Mount the standard type with a conventional connection bracket.
SRP
Relief flow characteristics
SRF
Possible to relieve (exhaust) air ranged 50 to 4000 L/min (ANR)
VCHR
Back pressure: 0.7 MPa
0.6 0.5 0.4 0.3 0.2
0.7
IR3010
0.6
IR401
0.5 0.4 0.3 0.2
0.1 600
500
400
300
200
100
0
Set pressure (MPa)
0.7
IR201
Set pressure (MPa)
IR2010
Back pressure: 0.7 MPa
0.1 5000
4000
3000
2000
1000
IC ITVX PVQ VEF VEP
VER VEA
0
Relief flow (L/min (ANR))
Relief flow (L/min (ANR))
ITV
VY1
Maximum set pressure
Port size
Air operated type
Basic type
Model
Specifications
IR100 IR200 IR300 IR2120 IR3120
Rc 1/8
Rc 1/4, Rc 3/8, - Rc 1/2, - 0.2 MPa 0.4 MPa 0.8 MPa
VBA VBAT
Made to Order Specifications
Series Variations, - Symbol
Specifications/Content
10-
Clean Series Copper-free and fluorine-free
AP100, - 20-, - 80-
Ozone resistant
-T
For high temperature, - -L
For low temperature (Except IR1000 type)
-X1
Non-grease specifications
-X170
Compatible with modular connection brackets (With modular adapter), - -X465
With digital pressure switch (ISE30A)
IRM
Manifold (Except Series IR2120, IR3000)
Note 1) For details, refer to page 724. Note 2) For part number combinations, consult SMC or its sales representative.
715
Page 4
Series IR1000/2000/3000 Application Example
Constant fluid pressure Balance and drive Accurate balance pressure setting TANK
• Since there is a large effective area for supply and exhaust pressure, setting can be done quickly. • Limits pressure fluctuation when driving a cylinder, maintaining excellent static and dynamic balance.
Accurate pressure setting, Sensitivity within 0.2% F.S. (Full Span) Tension control Contact pressure control Winding roller
Drive roller
Low friction cylinder
• Adapts to the cylinder's piston displacement, maintaining a constant pressure.
Multistage control of pressing force for workpiece (Wrapping machine) Leak test circuit
Measured object
Low friction cylinder
716
Page 5
Precision Regulator
RoHS
Series IR1000/2000/3000 Symbol
Basic type
Air operated type
ARJ AR425 to 935
Standard Specifications
ARX IR100
Max. supply pressure Min. supply pressure (1) Regulating pressure range
Air operated type
Basic type
Model
IR200
Set pressure + 0.05 MPa IR2000: 0.005 to 0.2 MPa IR2010: 0.01 to 0.4 MPa IR2020: 0.01 to 0.8 MPa
IR1000: 0.005 to 0.2 MPa IR1010: 0.01 to 0.4 MPa IR1020: 0.01 to 0.8 MPa
IR2120
IR3120
AMR
Set pressure + 0.05 MPa
Set pressure + 0.1 MPa
ARM
0.01 to 0.8 MPa
0.01 to 0.8 MPa
IR300 Max. 1.0 MPa Set pressure + 0.1 MPa IR3000: 0.01 to 0.2 MPa IR3010: 0.01 to 0.4 MPa IR3020: 0.01 to 0.8 MPa
ARP IR
Input signal (2) 0.01 to 0.8 MPa 0.01 to 0.8 MPa pressure Sensitivity (3) Within 0.2% of full span Repeatability (3) Within ±0.5% of full span Within ±1% of full span Linearity (4) Air consumption (5) 4.4 L/min (ANR) or less 4.4 L/min (ANR) or less 11.5 L/min (ANR) or less 4.4 L/min (ANR) or less 11.5 L/min (ANR) or less (At supply pressure of 1.0 MPa) Rc 1/4, 3/8, 1/2 Rc 1/4 Rc 1/4, 3/8, 1/2 Rc 1/4 Rc 1/8 Port size Rc 1/8 (2 locations) Pressure gauge port Ambient and fluid temperature –5 to 60°C (No freezing) 0.64 0.35 0.71 0.30 0.14 Weight (kg) Note 1) With the condition of no flow on the output side. Together with the set pressure, be sure to maintain a minimum differntial pressure of 0.05 MPa for models IR1000 and IR2000, and 0.1 MPa for model IR3000. Note 2) Applicable only to air operated types IR2120 and IR3120. The basic type is excepted. Note 3) Characteristic values do not contain any secular change and temperature change. Note 4) Indicates the linearity of the output pressure with respect to the input signal pressure. Note 5) Air is normally being discharged to the atmosphere from a bleed hole or an exhaust port.
How to Order
IR 2 0 0 0 2 3
IR2000 IR3000
0 1
Nil N F ∗ Option
0 0.005 to 0.2 MPa 1 0.01 to 0.4 MPa 0.01 to 0.8 MPa 2 Note) Air operated type is model IR2120 only.
For series IR3000 0 0.01 to 0.2 MPa 1 0.01 to 0.4 MPa 0.01 to 0.8 MPa 2 Note) Air operated type is model IR3120 only.
01 02 03 04
Rc NPT∗ G∗
Application
IR1000 IR2000 IR3000
1/8 1/4 3/8 1/2
Accessory ∗ Pressure gauge is included, (but not assembled).
Nil B
None With bracket With pressure gauge∗ Note) For the low temperature environment, no combinations with the pressure gauge “G” are available. Note) G
SRF VCHR ITV IC
VER VEA VY1
Suffix 2 Nil Note)
R
Port size
Symbol size, For high temp. enviroments (–5 to 100˚C) (Max. 80˚C with pressure gauge.) Note) L For low temp. enviroments (–30 to 60˚C) Note) Except IR1000 type. For IR3000 type, the combination of “L” and “X1” is not available. T
Thread type
SRP
VEF VEP
Nil
Regulating pressure range For series IR1000/2000
SRH
PVQ Suffix 1
Basic type (Handle) Air operated type (Series IR2000/3000 only)
VEX
ITVX
02
Precision regulator Body size Type of setting 1 IR1000
IRV
VBA VBAT, Pressure gauge, Bracket, Name plate, Mounting on the opposite side
AP100
Note) The standard mounting position of the pressure gauge is on the front, when viewing the regulator with the SUP side to the left and OUT side to the right.
Made to Order Specifications (Refer to page 724) Symbol Specifications/Content X1 Non-grease specifications X170 Compatible with modular connection brackets (Refer to page 718) X465 With digital pressure switch (ISE30A) ∗ 1 Add prefix (10-) for the clean room specification. ∗ 2 Add prefix (20-) for the copper-free and fluorine-free specification. ∗ 3 Add prefix (80-) for the ozone-resistant specification. ∗ 4 Manifold specification is available for IR1000 and IR2000. (Except IR2120 and IR3000)
717
Page 6
Series IR1000/2000/3000 Specification Combinations : Standard specifications : Combination possible
: Combination not possible
Series IR3000
Accessory
Option
Series IR2000
Series IR1000
Specifications
Symbol
Standard specifications
Applicable model
Set pressure Max. 0.2 MPa
0
Set pressure Max. 0.4 MPa
1
Set pressure Max. 0.8 MPa
2
Connection Rc 1/8
01
Connection Rc 1/4
02
Connection Rc 3/8
03
Connection Rc 1/2
04
Bracket
B
Pressure gauge
G
IR1000 IR1010 IR1020
IR2000 IR2010 IR2020
IR2120
IR3000 IR3010 IR3020
IR3120
Pressure gauge reverse mounted
R
Connection NPT 1/8
N01
Connection NPT 1/4
N02
Connection NPT 3/8
N03
Connection NPT 1/2
N04
Connection G 1/8
F01
Connection G 1/4
F02
Connection G 3/8
F03
Connection G 1/2
F04
-X170
IR20 0-
Modular and Accessory Combinations Applicable model
Description
IR10 0-
-X170
IR30 0-
-X170
1. Air filter
AF20
AF30
AF40
2. Mist separator
AFM20
AFM30
AFM40
3. Interface
Y200
Y300
Y400
4. Interface with bracket
Y200T
Y300T
Y400T
Note 1) Use the Made-to-Order product (IR -X170) for modular connections. The interface and interface with bracket listed above cannot be connected to the standard type. Use a conventional connection interface when connecting the standard type with modular connections. Note 2) The Made-to-Order product (IR-X170) is the product number with the modular adaptor attached to the standard product. The modular adaptor that has not been assembled to the product is shipped together. For the recommended tightening torque necessary to connect the modular adaptor, refer to page 591. When connecting the modular adaptor, please order applicable products or accessories separately.
Note 3) Product numbers with the bracket are not available for IR-X170. As the interface with the bracket is used, it is not necessary to attach the bracket to the IR.
<Combination example> ≅225
≅173
2
≅169
OUT
G
EXH
≅133
3
≅97
OUT eInterface rInterface with bracket
2
≅130
G
30.2 wAFM20
40.7 wAFM30 qAF20 qAF30
IR10 0- -X170
IR20 0- -X170 qAF40
IR30 0- -X170
Accessory (Option)/Part No. Description Bracket Pressure gauge ∗2 ∗3
50 wAFM40
Part no.
IR1000
IR1010
IR1020
IR2000
P36201023 G33-2-01
G33-4-01
IR2010
IR2020/2120
IR3000
G43-10-01
G43-2-01
P36202028 G33-10-01
G43-2-01
G43-4-01
IR3010
IR3020/3120
G43-4-01
G43-10-01
P362030-20∗1
∗1 A bracket and two mounting screws (M5 x 35) To mount the bracket, remove two body screws (M5 x 30) on the name plate on the opposite side and replace the attached two bracket mounting screws (M5 x 35). ∗2 Accuracy ±3% (Full span), Accuracy guarantee temperature range: 23±5°C ∗3 When ordering this pressure gauge individually, the sealant is not applied to the connection male thread. So, apply the sealing tape or sealant to the screw thread before use.
718
Page 7
Precision Regulator Series
IR1000/2000/3000
Construction IR1000
IR2000 i i
IR3000 q o q o i i
!5Fixed throttle
!5 SUP side passage
OUT side passage o
SUP side passage e w r
Exhaust
Valve guide w
AMR y
ARM
OUT(2)
ARP
Bleed
Diaphragm (C) OUT(2)
SUP(1)
Exhaust Valve
!2 !0
Main valve
!0
IR t
IRV
Valve guide
Valve guide
IR2120
IR3120
Working principle (For IR2000) When the setting knob is turned, the nozzle is closed by the flapper allowing the supply air that flows in from the upstream side to pass through the fixed throttle. It then acts on diaphragm B as nozzle back pressure, the main valve is pushed down by the generated force, and the supply pressure flows out to the downstream side. The air pressure that flows in acts on diaphragm C. While opposing the force generated by diaphragm B it also acts on diaphragm A, opposing the compression force of the setting spring and becomes the set pressure. If the set pressure rises too high, diaphragm A is pushed up, the interval between the flapper and the nozzle widens, the nozzle back pressure drops, the balance of diaphragms B and C is broken, the main valve closes, the exhaust valve opens and the excess pressure from the downstream side is discharged to the atmosphere. In this way fine pressure variations are detected by the nozzle/flapper type pilot mechanism, and precise pressure adjustment is performed.
ARX
!1 !3 !2
Diaphragm (B) Exhaust u r !0 q
Nozzle
SUP(1)
OUT(2)
ARJ AR425 to 935
Steel ball w
OUT side passage
Diaphragm (A)
Bleed u
SUP side passage
Setting knob q
SUP(1)
!5
OUT side passage q
Bleed
!4
VEX q o o i
!5
!5 SUP side passage
SUP side passage
ITV
IN Bleed q w
!1 !3 !2 y
ITVX
SUP(1)
OUT(2)
PVQ
Bleed
OUT(2)
u !0
!2 !0 Valve guide
Replacement Parts
SRF VCHR
IN
SUP(1)
IC
VEF VEP t
Valve guide
IR2120
VER
No.
Description
Material
IR100 Part no.
Qty.
IR200 Part no.
Qty.
IR300 Part no.
Qty.
Part no.
Qty.
Part no.
Qty.
1
Diaphragm assembly
NBR, other
P362010-1
1
P362020-2
1
P362020-2
1
P362020-13
1
P362020-13
1
2
Diaphragm assembly
NBR, other
P362010-2
1
P362020-5
1
P362030-1
1
P362020-5
1
P362030-1
1
3
Diaphragm
NBR, other, - - - P36202019
1, - Valve
Stainless steel, NBR
P36201058
1
P36202019 P36202068#1
1
4
1, - P36202068#1
1, - 5
Valve
Brass, NBR, - - - P36203009#1
1, - P36203009#1
1
6
Valve
Brass, NBR, - - - P36203010#1
1, - P36203010#1
1
7
Damper
NBR, other
P36201021
1
P36202026
1, - P36202026
1, - 8
O-ring
H-NBR
ø2.5 x 1.05
3
ø1.42 x 1.52
2, - ø1.42 x 1.52
2, - IR3120
9
O-ring
NBR, - ø4.5 x 1
3
ø4.5 x 1
1
ø4.5 x 1
3
ø4.5 x 1
1
10
O-ring
NBR
ø10 x 1.3
1
JISB2401P11
1
ø27.8 x 1.5
1
JISB2401P11
1
ø27.8 x 1.5
1
11
O-ring
NBR, - - 12
O-ring
NBR, - - 13
Seal (A)
NBR, - 14
Seal (B)
NBR, 15
Fixed throttle
Stainless steel
P36202018
Repair kit no. (A set of above nos. q to !5.)
KT-IR1000, - JISB2401P5 Note 2) 1, - JISB2401P16 Note 2) 2, - JISB2401P5 Note 2) 1, JISB2401P16 Note 2) 2 P36203015, 1, - P36203015
1, - - P36203016
3, - P36203016
3
1
P36202018
1
P36203017
1
P36202018
1
P36203017
1
KT-IR2000
SRH SRP
OUT side passage
OUT side passage q e w q o
!4
KT-IR3000
KT-IR2120
KT-IR3120
Note 1) The replacement parts are shipped with the repair kit number. Note 2) Use mini-flick type.
719
VEA VY1 VBA VBAT
AP100
Page 8
Series IR1000/2000/3000 Dimensions IR100-01
IR200-02 0.5
ø1
Mounting hole
50 36
Mounting hole Bracket (Option)
Panel mounting hole
Pressure gauge (Option) Panel ∗ When mounting on a panel, refer to page 725 in Specific Product Precautions.
Panel ∗ When mounting on a panel, refer to page 725 in Specific Product Precautions. 4.5
2.5
ø1
Max.4
Pressure gauge (Option)
2
Panel mounting hole
30
25
Bracket (Option)
Max.4
2
42 28
M5 x P0.5
M6 x P0.5
ø43
2 x Rc 1/8 Port size
50
2 x Rc 1/8 Pressure gauge port
2 x Rc 1/8 Pressure gauge port
50 2
IR2120-02
Bracket (Option) Pressure gauge (Option)
2.5
ø1
5.5 .5
Panel mounting hole
76
2.3
82 60
50 ≅60
2 x Rc 1/4 Port size
Mounting hole Bracket (Option) Pressure gauge (Option)
EXH(3)
OUT(2)
M5 depth 7
IN
Bleed
EXH(3)
OUT(2)
22
SUP(1)
≅144
5.
9
76
2 x Rc 1/8 Pressure gauge port
Rc 1/2 Exhaust port 2 x Rc 1/4 to 1/2 Port size
ø43
≅68
ø1
66 66
5
22
SUP(1)
2 x Rc 1/8 Pressure gauge port
48
ø43
IR3120-0 ≅148
ø1 5.5
Bleed
Exhaust OUT(2) 50
M6 x P0.5
75 83 ≅119
Bleed SUP(1)
∗ When mounting on a panel, refer to page 725 in Specific Product Precautions.
9
M5 depth 7
IN
ø43
Pressure gauge (Option) Panel
ø9
Max.4
Bracket (Option)
48
2.3
Mounting hole
2 x Rc 1/4 Port size
Mounting hole
36
30
IR300-0 82 60
50
≅60
(17.7)
≅43
35
(17.7)
35
EXH
63 71
Exhaust OUT(2)
SUP(1)
≅124
ø9 Bleed
9.5
OUT(2)
ø30
Bleed SUP(1)
≅92
46 52.5
.5
ø8 .5
5.5
66
≅68 2 x Rc 1/8 Pressure gauge port
720
66
Rc 1/2 Exhaust port 2 x Rc 1/4 to 1/2 Port size
Page 9
Precision Regulator Series
IR1000/2000/3000
Series IR1000 ∗ The operating conditions or external disturbance may affect each of the characteristics. So, the characteristic values shown below are not guaranteed.
Flow Characteristics
Relief Characteristics
Pressure Characteristics
IR1000-01
IR1000-01
IR1000-01
Supply pressure: 0.5 MPa
Back pressure: 0.5 MPa
Set pressure (MPa)
0.4
0.15
0.3 0.1 0.2 0.05
Set pressure (MPa)
0.5
0.2
Set pressure P2 (MPa)
∗ Testing methods conform to JIS B 8372.
Supply pressure: 0.7 MPa Set pressure: 0.2 MPa Flow rate: 0 L/min (ANR)
0.204
ARJ
0.202
AR425 to 935 Set point
ARX
0.200
AMR
0.198
ARM
0.1 0.196 50
100
150
200
250
140
Flow rate (L/min (ANR))
IR1010-01
120
100
80
60
40
20
Supply pressure: 0.7 MPa
IR1010-01
0
0.3
0.5 0.4
0.2
0.3
Set pressure (MPa)
0.7 0.6
0.204
VEX
150
200
250
300
350
200
IR1020-01
160
120
80
40
Set point
IR1020-01
0.198
SRF
0.196
VCHR 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Supply pressure P1 (MPa)
1.0
0.7
0.8 0.6
0.7
0.5
0.6
0.4
0.5 0.4
0.3
0.3
0.2
ITVX PVQ
0.202
VEF VEP
Set point
0.200
VER
0.198
VEA
0.2
0.1
0.1 100
200
300
400
Flow rate (L/min (ANR))
500
300
200
100
Relief flow rate (L/min (ANR))
0
ITV IC
IR1020-01 0.204
0.9
Set pressure (MPa)
Set pressure (MPa)
SRP
0
Back pressure: 1.0 MPa
0.8
0
0.200
Relief flow rate (L/min (ANR))
Supply pressure: 1.0 MPa
SRH
0.202
Set pressure P2 (MPa)
100
Flow rate (L/min (ANR))
IR IRV
0.1
50
ARP
IR1010-01
0.2
0.1
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Supply pressure P1 (MPa)
Back pressure: 0.7 MPa
0.4
Set pressure (MPa)
0
Relief flow rate (L/min (ANR))
Set pressure P2 (MPa)
0
VY1
0.196 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Supply pressure P1 (MPa)
VBA VBAT
AP100
721
Page 10
Series IR1000/2000/3000
Series IR2000 ∗ The operating conditions or external disturbance may affect each of the characteristics. So, the characteristic values shown below are not guaranteed.
Flow Characteristics
Relief Characteristics
Pressure Characteristics
IR2000-02
IR2000-02
∗ Testing methods conform to JIS B 8372.
IR2000-02
Supply pressure: 0.5 MPa
Back pressure: 0.5 MPa
0.204
0.3 0.1
0.2
0.05
0.1
Set pressure P2 (MPa)
0.4 0.15
Set pressure (MPa)
Set pressure (MPa)
0.5 0.2
Supply pressure: 0.7 MPa Set pressure: 0.2 MPa Flow rate: 0 L/min (ANR)
0.202
Set point
0.200
0.198
0.196 0
100
200
300
400
500
600
400
700
Flow rate (L/min (ANR))
IR2010-02
Supply pressure: 0.7 MPa
300
200
100
0
0
IR2010-02
Supply pressure P1 (MPa)
Back pressure: 0.7 MPa
IR2010-02
0.7
0.5
0.3
0.4 0.2
0.3
0.204
0.2
0.1
Set pressure P2 (MPa)
0.6
Set pressure (MPa)
Set pressure (MPa)
0.4
0.1 100 200 300 400 500 600 700 800 900
500
Flow rate (L/min (ANR))
IR2020-02
Supply pressure: 1.0 MPa
400
300
200
100
IR2020-02
IR2020-02 0.204
0.7
0.5
0.6
0.4
0.5 0.4
0.3
0.3
Set pressure P2 (MPa)
0.8
0.202
Set point
0.200
0.198
0.2
0.1
0.1 200
400
600
800
1000 1200 1400
1000
Flow rate (L/min (ANR))
IR2120-02
Supply pressure: 1.0 MPa
800
600
400
200
0.196
0
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Relief flow rate (L/min (ANR))
IR2120-02
Supply pressure P1 (MPa)
Back pressure: 1.0 MPa
IR2120-02
1.0 0.204
0.9 0.7
0.8
0.6
0.7
0.5
0.6
0.4
0.5 0.4
0.3
0.3
0.2
Set pressure P2 (MPa)
0.8
Set pressure (MPa)
Set pressure (MPa)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Supply pressure P1 (MPa)
0.9
0.2
Set pressure (MPa)
0.198
1.0
0.6
0.202
Set point
0.200
0.198
0.2
0.1
0.1 200
400
600
800
1000
1200 1400
Flow rate (L/min (ANR))
722
0.200
0
Back pressure: 1.0 MPa
0.7
0
Set point
Relief flow rate (L/min (ANR))
0.8
0
0.202
0.196
0
Set pressure (MPa)
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Relief flow rate (L/min (ANR))
1000
800
600
400
200
Relief flow rate (L/min (ANR))
0
0.196 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Supply pressure P1 (MPa)
Page 11
Precision Regulator Series
IR1000/2000/3000
Series IR3000 ∗ The operating conditions or external disturbance may affect each of the characteristics. So, the characteristic values shown below are not guaranteed.
Flow Characteristics
Relief Characteristics
Pressure Characteristics
IR3000-03
IR3000-03
IR3000-03
Supply pressure: 0.5 MPa
Back pressure: 0.5 MPa
Set pressure (MPa)
0.4 0.15 0.3 0.1 0.2 0.05
Set pressure (MPa)
0.5
0.2
Set pressure P2 (MPa)
∗ Testing methods conform to JIS B 8372.
Supply pressure: 0.7 MPa Set pressure: 0.2 MPa Flow rate: 0 L/min (ANR)
0.204
ARJ
0.202
AR425 to 935
Set point
0.200
ARX
0.198
AMR
0.196
ARM
0.1 0.194 1000
0
2000
3000
4000
3500 3000 2500 2000 1500 1000
Flow rate (L/min (ANR))
IR3010-03
500
Supply pressure: 0.7 MPa
IR3010-03
0.4 0.2
0.3
Set pressure P2 (MPa)
0.5
Set pressure (MPa)
0.6 0.3
0.2
0.1
0.1 2000
3000
4000
5000
6000
4000
Flow rate (L/min (ANR))
IR3020-03
3000
2000
1000
IRV
0.202
VEX
0.200
Set point
SRP
0.196
SRF
0
0
IR3020-03
VCHR 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Supply pressure P1 (MPa)
Back pressure: 1.0 MPa
0.7
0.9
0.6
0.8 0.7
0.5
0.6
0.4
0.5
0.3
0.4 0.3
0.2
Set pressure (MPa)
1.0
IR3020-03
ITVX
0.202
PVQ
0.200
Set point 0.198
VEF VEP
0.196
VER
3000
4000
5000
6000
6000
Flow rate (L/min (ANR))
IR3120-03
5000
4000
3000
2000
1000
Set pressure (MPa)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Relief flow rate (L/min (ANR))
Supply pressure: 1.0 MPa
IR3120-03
Supply pressure P1 (MPa)
Back pressure: 1.0 MPa
0.8
1.0
0.7
0.9
0.6
0.8 0.7
0.5
0.6
0.4
0.5
0.3
0.4 0.3
0.2
0.1 1000
2000
3000
4000
5000
Flow rate (L/min (ANR))
6000
6000
5000
4000
3000
2000
1000
Relief flow rate (L/min (ANR))
0
0.204
AP100
0.202 0.200
Set point 0.198 0.196 0.194 0
VY1 VBA VBAT
IR3120-03
0.2
0.1 0
0
0
Set pressure P2 (MPa)
2000
VEA
0.194
0.1 1000
Set pressure (MPa)
0
ITV IC
0.204
0.2 0.1
SRH
0.198
Relief flow rate (L/min (ANR))
Supply pressure: 1.0 MPa
0.8
Set pressure (MPa)
0.204
0.194
Set pressure P2 (MPa)
1000
ARP IR
IR3010-03
0.7
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Supply pressure P1 (MPa)
Back pressure: 0.7 MPa
0.4
Set pressure (MPa)
0
0
Relief flow rate (L/min (ANR))
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Supply pressure P1 (MPa)
723
Page 12
Series IR1000/2000/3000
Made to Order Specifications:
Please contact SMC for detailed dimensions, specifications, each part number and lead times.
1 Clean Series
6 With Digital Pressure Switch
10
With digital pressure switch (model no: ISE30A-01--ML). Mount a digital pressure switch into the connection port for pressure gauge, as it is not mounted at the time of shipment.
Standard model no. Note) Please contact SMC if a product with pressure gauge is desired.
Clean Series Specifications Cleanliness Bleed hole EXH port Grease
Class 10000 With M5 fitting (Applicable tubing O.D. ø6) IR1000/2000: With M5 fitting (Applicable tubing O.D. ø6) IR3000: Rc 1/2 female thread Fluorine grease
2 Copper-free and Fluorine-free External and internal copper parts are changed to stainless steel or aluminum.
20
Standard model no. Note) Please contact SMC if a product with pressure gauge is desired.
Copper-free and Fluorine-free
Specifications Made to order part no. Set pressure range (MPa) Pressure Desolution of setting and display (MPa) switch
Power supply voltage Current consumption
–X465 –0.1 to 1 0.001 12 to 24 VDC ±10%, Ripple (p-p) 10% or less (With reverse connection protection) 40 mA or less
How to Order
Standard model no. Note)
X465 A
Note) Except for symbol “G”
With digital pressure switch Switch specifications
Note 1) Please contact SMC separately for details about the external dimensions, etc. Note 2) For details on handling digital pressure switch and specifications, refer to page 767 of Best Pneumatics No.6. Note 3) Digital pressure switch is packed togther.
Symbol
A B C D
Output specifications NPN open collector 1 output PNP open collector 1 output NPN open collector 1 output + Analog voltage output NPN open collector 1 output + Analog current output
7 Manifold Specifications (Except type IR2120 and series IR3000) 3 Ozone Resistant
2 to 8 station manifold type regulators. (Please contact SMC regarding 9 or more stations.)
Fluoro rubber is used for rubber seal materials.
80
IRM 10
Standard model no.
3 G Set pressure and quantity 0 1 2
Ozone resistant
4 For High/Low Temperature Environments T Stations
For high/low temperature environments LNote)
Specifications
For high temperature For low temperature
10 20
Assembly is performed in an ordinary environment without using grease. However, since parts are not washed, they are not completely oil-free.
Standard model no.
X1 Non-grease specifications
724
8 stations
IR1000 IR2000
Manifold type regulator Specifications Stations Port
5 Non-grease Specifications
8
Body size
Note) Except IR1000 type. For IR3000 type, the combination of “L” and “X1” is not available.
T L Symbol Environment For high temp. environments For low temp. environments –5 to 100°C Ambient –30 to 60°C temperature (Max. 80°C with pressure gauge) Rubber material Fluororubber Special NBR
2 stations
...
T
2 ...
Standard model no.
Set pressure
0.2 MPa setting 1 to n pcs. 0.4 MPa setting 1 to n pcs. 0.8 MPa setting 1 to n pcs.
Example 1) 0.4 MPa setting with 6 stations IRM10-6G-16 Example 2) 0.2 MPa setting 2 pcs., 0.4 MPa setting 2 pcs., 0.8 MPa setting 1 pc. with 5 stations IRM20-5G-021221
Accessory (Pressure gauge)∗ Nil
None IR1000: G33--01 IR2000: G43--01 ∗ Accessory (pressure gauge) is included, (but not assembled). G
Thread type (Thread on the manifold base) Nil N F
Rc NPT G
2 to 8 stations Common SUP IR1000: 1/4, IR2000: 1/2 Individual OUT IR1000: 1/8, IR2000: 1/4 Individual EXH (From IR body) 0.2 MPa, 0.4 MPa and 0.8 MPa settings can be combined.
Accessory G33--01 (IR1000), G43--01 (IR2000) (Pressure gauge) Note 1) Regulators to be manifolded are counted starting from stations 1 on the left side with the OUT ports in front. Note 2) When regulators with a different set pressure are manifolded, viewing OUT ports from front, the low pressure range is installed on the left side and high pressure range is on the right side. In case of the “Example 2)” above mentioned, stations 1 and 2 are of 0.2 MPa setting, stations 3 and 4 are of 0.4 MPa setting, and station 5 is of 0.8 MPa setting. Note 3) Please consult with SMC when a blanking plate is needed.
Page 13
Series IR1000/2000/3000
Specific Product Precautions
Be sure to read before handling. Refer to front matter 43 for Safety Instructions and pages 365 to 369 for Precautions on every series.
Air Supply
Operation
Caution
Warning 1. If the drain removal from air filter and mist separator is missed, drain will be flown out to the outlet side and may result in a malfunction of the pneumatic equipment. When removing drain is difficult, use of a filter with an autodrain is recommended.
Caution 1. If the supply pressure line contains drain or particlate, etc., the fixed throttle can become clogged leading to malfunction, and therefore, in addition to an air filter (SMC Series AF) be sure to use a mist separator (SMC Series AM, AFM). Refer to pages 2 and 3 regarding air quality. 2. Never use a lubricator on the supply side of the regulator, as this will positively cause the fixed throttle to become clogged and result in a malfunction. If lubrication is required for terminal devices, connect a lubricator on the output side of the regulator.
Maintenance
Warning 1. When the valve guide (refer to construction drawing on page 719) is to be removed during maintenance, first reduce the set pressure to “0” and completely shut off the supply pressure. 2. When a pressure gauge is to be mounted, remove the plug after reducing the set pressure to “0”.
Precautions for IR100 only
Warning
ARJ
1. Do not use a precision regulator outside the range of its AR425 specifications as this can cause failure. (Refer to to 935 specifications.) 2. When mounting is performed, make connections while ARX confirming port indications. 3. Screw a panel nut with the recommended proper torque AMR when mounting onto a panel. Looseness or faulty sealing will occur if tightening torque is ARM insufficient, while thread damage will result if the torque is excessive.
Recommended Proper Torque IR1000 IR2000 12.5 21
(N·m)
IR3000 21
4. If a directional switching valve (solenoid valve, mechanical valve, etc.) is mounted on the supply side of the regulator and repeatedly switched ON and OFF, wear of the nozzle/flapper section will be accelerated and a discrepancy in the setting value may occur. Therefore, avoid using a directional switching valve on the supply side. In the event a directional switching valve will be used, install it on the output side of the regulator. 5. The accessory pressure gauge is supplied with the regulator in the unassembled status. Before using the regulator, be sure to install the pressure gauge at the gauge port of the regulator. At this time, the recommended tightening torque of the pressure gauge is 7 to 9 N·m. 6. Air is normally released from the bleed hole (the hole on the side of the body’s mid-section). This is a necessary consumption of air based on the construction of the precision regulator, and is not an abnormality. 7. Make sure to tighten the lock nut after pressure adjustment.
Precautions for IR300, IR3120 only
1. When remounting the valve guide after removing it for maintenance, use a tightening torque of no more than 0.6 N·m. Since the valve guide on this product is made of resin, there is a danger of damage if tightened with a torque exceeding the prescribed value.
Handling
Caution 1. Do not apply force when transferring, mounting and dropping the regulator with a pressure gauge. This may cause misalignment of the pressure gauge pointer.
ARP IR IRV VEX
SRH SRP SRF VCHR ITV IC ITVX PVQ
Caution 1. The supply pressure is relatively high (approx. 0.5 MPa or more), the set pressure is low (approx. 0.1 MPa or less), and when operated with the output side released to the atmosphere, there may be pulsations in the setting pressure. In this kind of situation, operate with the supply pressure reduced as much as possible, or increase the set pressure somewhat and restrict the output line (add and adjust a stop valve, etc.). 2. The capacity of the output side is large, and when used for the purpose of a relief function, the exhaust sound will be loud when being relieved. Therefore, operate with a silencer (SMC Series AN) mounted on the exhaust port (EXH port). The connection is Rc 1/2.
Precautions for IR2120, IR3120 (air operated type) only
Caution 1. Since the output types of IR2120 and IR3120 are the same pressure as the input signal pressure, select a type of regulator (general purpose or precision type) for input signal pressure adjustment according to the application. 2. The screw on the topmost section is a zero point adjustment screw which is locked at the factory and requires no adjustment for operation.
725
VEF VEP
VER VEA VY1 VBA VBAT
AP100